Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Kansas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Contingency interim measure for the public water supply at Barnes, Kansas.

This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply wells. Carbon tetrachloride was used in the treatment of grain. Another potential source identified in an investigation conducted for the KDHE (PRC 1996) is the site of a former agriculture building owned by the local school district (USD 223). This building is located immediately east of well PWS3. The potential contingency IM options evaluated in this report include the treatment of groundwater at the public water supply wellheads and the provision of an alternate water supply via Washington County Rural Water District No.2 (RWD 2). This document was developed in accordance with KDHE Bureau of Environmental Remediation (BER) Policy No.BER-RS-029 (Revised) (KDHE 2006a), supplemented by guidance from the KDHE project manager. Upon the approval of this contingency IM conceptual design by the KDHE, the CCC/USDA will prepare a treatment system design document that will contain the following elements: (1) Description of the approved contingency IM treatment method; (2) Drawings and/or schematics provided by the contractor and/or manufacturer of the approved technology; (3) A detailed work schedule with a generic timetable; (4) A detailed operations and maintenance plan; (5) A proposed performance monitoring plan; and (6) A fact sheet associated with a community relations plan.

54 ENVIRONMENTAL SCIENCES↗

Results of groundwater monitoring and vegetation sampling at Everest, Kansas, in 2009 .

In April 2008, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) conducted groundwater sampling for the analysis of volatile organic compounds (VOCs) in the existing network of monitoring points at Everest, Kansas (Argonne 2008). The objective of the 2008 investigation was to monitor the distribution of carbon tetrachloride contamination in groundwater previously identified in CCC/USDA site characterization and groundwater sampling studies at Everest in 2000-2006 (Argonne 2001, 2003, 2006a,b). The work at Everest is being undertaken on behalf of the CCC/USDA by Argonne National Laboratory, under the oversight of the Kansas Department of Health and Environment (KDHE). The findings of the 2008 investigation were as follows: (1) Measurements of groundwater levels obtained manually and through the use of automatic recorders demonstrated a consistent pattern of groundwater flow - and inferred contaminant migration - to the north-northwest from the former CCC/USDA facility toward the Nigh property, and then west-southwest from the Nigh property toward the intermittent creek that lies west of the former CCC/USDA facility and the Nigh property. (2) The range of concentrations and the areal distribution of carbon tetrachloride identified in the groundwater at Everest in April 2008 were generally consistent with previous results. The results of the 2008 sampling (reflecting the period from 2006 to 2008) and the earlier investigations at Everest (representing the period from 2000 to 2006) show that no significant downgradient extension of the carbon tetrachloride plume occurred from 2000 to 2008. (3) The slow contaminant migration indicated by the monitoring data is qualitatively consistent with the low groundwater flow rates in the Everest aquifer unit estimated previously on the basis of site-specific hydraulic testing (Argonne 2006a,b). (4) The April 2008 and earlier sampling results demonstrate that the limits of the plume have been effectively, identified by the existing network of monitoring points and have not changed significantly during the CCC/USDA investigation program. The carbon tetrachloride distribution within the plume has continued to evolve, however, with relatively constant or apparently decreasing contaminant levels at most sampling locations. In response to these findings, the KDHE requested that the CCC/USDA develop a plan for annual monitoring of the groundwater and surface water at Everest, to facilitate continued tracking of the carbon tetrachloride plume at this site (KDHE 2009a). A recommendation for annual sampling (for analyses of VOCs) of 16 existing groundwater monitoring points within and near the identified contaminant migration pathway and surface water sampling at 5 locations along the intermittent creek west (downgradient) of the identified plume was presented by the CCC/USDA (Appendix A) and approved by the KDHE (2009b) for implementation. The monitoring wells will be sampled according to the low-flow procedure, and sample preservation, shipping, and analysis activities will be consistent with previous work at Everest. The annual sampling will continue until identified conditions at the site indicate a technical justification for a change. This report summarizes the results of sampling and monitoring activities conducted at the Everest site since completion of the April 2008 groundwater sampling event (Argonne 2008). The investigations performed during the current review period (May 2008 to October 2009) were as follows: (1) With one exception, the KDHE-approved groundwater and surface water monitoring points were sampled on April 24-27, 2009. In this event, well PT1 was inadvertently sampled instead of the adjacent well MW04. This investigation represents the first groundwater and surface water sampling event performed under the current plan for annual monitoring approved by the KDHE. (2) Ongoing monitoring of the groundwater levels at Everest is performed with KDHE approval. The levels in selected monitoring wells are recorded continuously, by using downhole pressure sensors equipped with automatic data loggers, and periodically are also measured manually. Groundwater level data were recovered during the current review period on September 19, 2008, and on March 25, April 25-27, and October 20, 2009. (3) Argonne experience has demonstrated that the sampling and analysis (for VOCs) of native vegetation, and particularly tree tissues, often provides a sensitive indicator of possible carbon tetrachloride contamination in the surface water or shallow groundwater within the plant rooting zone. With the approval of the CCC/USDA, on August 28, 2009, samples of tree branch tissues were therefore collected for analyses at 18 locations along the intermittent creek west (downgradient) of the former CCC/USDA facility and the Nigh property.

54 ENVIRONMENTAL SCIENCES↗

The application of remote sensing to resource management and environmental quality programs in Kansas

Activities of the Kansas Applied Remote Sensing Program (KARS) designed to establish interactions on cooperative projects with decision makers in Kansas agencies in the development and application of remote sensing procedures are reported. Cooperative demonstration projects undertaken with several different agencies involved three principal areas of effort: Wildlife Habitat and Environmental Analysis; Urban and Regional Analysis; Agricultural and Rural Analysis. These projects were designed to concentrate remote sensing concepts and methodologies on existing agency problems to insure the continued relevancy of the program and maximize the possibility for immediate operational use. Completed projects are briefly discussed.

Barr, B. G.↗

A comparative statistical study of long-term agroclimatic conditions affecting the growth of US winter wheat: Distributions of regional monthly average precipitation on the Great Plains and the state of Maryland and the effect of agroclimatic conditions on yield in the state of Kansas

A histogram analysis of average monthly precipitation over 30 and 84 year periods for both Maryland and Kansas was made and the results compared. A second analysis, a statistical assessment of the effect of average monthly precipitation on Kansas winter wheat yield was made. The data sets covered the three periods of 1941-1970, 1887-1970, and 1887-1921. Analyses of the limited data sets used (only the average monthly precipitation and temperature were correlated against yield) indicated that fall precipitation values, especially those of September and October, were more important to winter wheat yield than were spring values, particularly for the period 1941-1970.

Welker, J.↗

East Kansas Agri-Energy, LLC

This is a combined heat and power (CHP) project profile on a 1.6 MW CHP application at East Kansas Agri-Energy, LLC in Garnett, Kansas.

AMO↗

Rebuilding It Better: Greensburg, Kansas. Kiowa County Courthouse (Brochure)

This document is one in a series of five that showcases the green, sustainable buildings in Greensburg, Kansas. The Kiowa County Courthouse was one of only two buildings left standing after the tornado, which allowed the building to be renovated and refurbished rather than torn down.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Tragedy to Triumph: Rebuilding Greensburg, Kansas To Be a 100% Renewable Energy City; Preprint

On May 4, 2007, Greensburg, Kansas, was hit by a 1.7-mile wide tornado with 200 mph-plus wind speeds. This tornado destroyed or severely damaged 90% of Greensburg?s structures. We discuss the progress made in rebuilding Greensburg, with a focus on the built environment and on meeting Greensburg?s goal of 100% renewable energy, 100% of the time. We also discuss key disaster recovery efforts thatenabled Greensburg to reach this goal. Key strategies included a Sustainable Comprehensive Master Plan, an ordinance resolving that city-owned buildings achieve LEED Platinum and 42% energy savings, a strong focus on rebuilding 'right' with an integrated design process, attracting significant and sustained technical experts and national media attention, and linking renewable and energyefficiency technologies to business development. After three years, more than half the homes that have been rebuilt are rated at an average of 40% energy savings. All significant commercial buildings, including the school, hospital, banks, courthouse, and retail buildings, have been rebuilt to LEED Gold and Platinum standards and exceed 40% savings, with many exceeding 50% savings. Greensburgrecently constructed a 12.5-MW community wind farm to provide all the remaining energy needed for its energy-efficient buildings and homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Island Mitigation Assessment and Policy Development for the Kansas City Region

Lawrence Berkeley National Laboratory partnered with Mid-America Regional Council (MARC) to quantify the costs and benefits from the adoption of urban heat island (UHI) countermeasures in the Kansas City region (population 1.5 million), and identify the best regional implementation pathway for MARC. The team selected cool (high-albedo) roofs and increased vegetation as the two countermeasures to evaluate. For vegetation, there were two strategies: (1) planting new trees to shade building surfaces, and (2) increasing urban irrigation (a surrogate for the use of vegetation to manage stormwater) to increase evapotranspiration. Using the Weather Research and Forecasting (WRF) model we simulated selected weeks during summer time, across five years (2011 2015) representing a range of normal summer conditions. We also simulated six of the most intense heatwaves that occurred between 2004 and 2016. We found under typical summer conditions (non-heatwave) average daytime (07:00 19:00 local standard time) regional near-ground air temperature reductions of 0.08 and 0.28 C for cool roofs and urban irrigation, respectively. We calculated the building electricity, electricity cost, and emission savings that result from the reduction in outdoor air temperature (indirect savings) and found maximum regional annual indirect electricity savings of 42.8 GWh for cool roofs and 85.6 GWh for urban irrigation-yielding maximum regional annual indirect electricity cost savings of $\$ $5.6M ($\$ $0.05/m 2 roof) and $\$ $11.1M ($0.01/m 2 irrigated land), respectively, and maximum regional annual CO 2 savings of 43.4 kt and 80 kt, respectively. We next evaluated the building energy, energy cost, and emission savings from reducing direct absorbed radiation on the building surfaces using cool roofs and shade trees (direct savings). For cool roofs, we found regional annual direct energy cost savings of $\$ $10.9M ($\$ $0.15/m 2 roof) with regional annual CO 2 savings of 66.4 kt. For shade trees, the regional annual direct energy cost savings were $\$ $21M ($\$ $21/tree) with regional annual CO 2 savings of 126 kt. We investigated cool roof cost premiums (the additional cost for selecting a cool roof product in lieu of a conventional roof product, estimated to be zero to $\$ $2.15/m 2 ) and shade tree first costs (assumed to be $\$ $100 per tree). The regional cool roof cost premium was calculated using the regional roof area per roofing material type and the range of cool roof product premiums for each material type. The extra cost of selecting cool roofs across the region ranged from $\$ $4.33M to $\$ $87.1M, while the additional shade trees planted across the region were assumed to cost $\$ $102M. When we compared the regional annual direct cost savings to the regional cool-roof cost premium and the regional shade-tree first cost, we found regional simple payback times up to 8.0 years for cool roofs and 4.9 years for trees, respectively. Since this comprehensive assessment of UHI countermeasures is a valuable methodology for other local governments to apply, we developed a step-by-step guide for others to follow. Based on the benefits and costs of the UHI countermeasures, MARC will pursue the inclusion of these countermeasures in existing regional plans where they can complement other regional priorities for transportation, climate resiliency, clean air, and hazard mitigation. They hosted a local workshop in 2016 for stakeholders to introduce the topic and will continue to share these resources to further appropriate adoption of UHI countermeasures.

urban climate↗

Feasibility Study of Economics and Performance of Biomass Power Generation at the Former Farmland Industries Site in Lawrence, Kansas - A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

Under the RE-Powering America's Land initiative, the U.S. Environmental Protection Agency (EPA) provided funding to the National Renewable Energy Laboratory (NREL) to support a feasibility study of biomass renewable energy generation at the former Farmland Industries site in Lawrence, Kansas. Feasibility assessment team members conducted a site assessment to gather information integral to this feasibility study. Information such as biomass resources, transmission availability, on-site uses for heat and power, community acceptance, and ground conditions were considered.

09 BIOMASS FUELS↗

EPA RE-Powering America's Lands: Kansas City Municipal Farm Site ₋ Biomass Power Analysis

Through the RE-Powering America's Land initiative, the economic and technical feasibility of utilizing biomass at the Kansas City, Missouri, Municipal Farm site, a group of City-owned properties, is explored. The study that none of the technologies we reviewed--biomass heat, power and CHP--are economically viable options for the Municipal Farms site. However, if the site were to be developed around a future central biomass heating or CHP facility, biomass could be a good option for the site.

09 BIOMASS FUELS↗

Demonstration of LED Street Lighting in Kansas City, MO

This report documents a study of nine different light-emitting diode (LED) street lighting products installed in February 2011 as replacements for incumbent high-pressure sodium (HPS) luminaires in the city of Kansas City, Missouri (KCMO). The subject lighting investigation was undertaken by the city as part of a continued focus on improving street safety that had begun with an earlier extensive upgrade to the streetlighting system in the late 1990s, which substantially improved both the quantity and uniformity of its lighting. The current study was conducted in support of the U.S. Department of Energy’s Municipal Solid-State Street Lighting Consortium, via support of the GATEWAY Solid-State Lighting Technology Demonstration Program, and involved multiple staff from different organizations employing a variety of meters and procedures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of contaminant sources at Navarre, Kansas.

The results of the 2006 investigation of contaminant sources at Navarre, Kansas, clearly demonstrate the following: {sm_bullet} Sources of carbon tetrachloride contamination were found on the Navarre Co-op property. These sources are the locations of the highest concentrations of carbon tetrachloride found in soil and groundwater at Navarre. The ongoing groundwater contamination at Navarre originates from these sources. {sm_bullet} The sources on the Co-op property are in locations where the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) never conducted grain storage operations. {sm_bullet} No definitive sources of carbon tetrachloride were identified on the portion of the current Co-op property formerly used by the CCC/USDA. {sm_bullet} The source areas on the Co-op property are consistent with the locations of the most intense Co-op operations, both historically and at present. The Co-op historically stored carbon tetrachloride for retail sale and used it as a grain fumigant in these locations. {sm_bullet} The distribution patterns of other contaminants (tetrachloroethene and nitrate) originating from sources on the Co-op property mimic the carbon tetrachloride plume. These other contaminants are not associated with CCC/USDA operations. {sm_bullet} The distribution of carbon tetrachloride at the Co-op source areas, particularly the absence of contamination in soils at depths less than 20 ft below ground level, is consistent with vertical migration into the subsurface through a conduit (well Co-op 2), with subsequent lateral migration through the subsurface. {sm_bullet} The groundwater flow direction, which is toward the west-northwest, is not consistent with migration of carbon tetrachloride in groundwater from the former CCC/USDA property to the source areas on the Co-op property. {sm_bullet} The absence of soil and groundwater contamination along surface drainage pathways on the former CCC/USDA property is not consistent with migration of carbon tetrachloride in surface water runoff from the former CCC/USDA property to the source areas on the Co-op property. {sm_bullet} The contamination detected in soil and groundwater samples collected along the northern boundary of the former CCC/USDA facility can be attributed to migration from the Co-op sources or to operations of the Co-op on the property after CCC/USDA operations ended. {sm_bullet} The southern boundary of the Co-op property has expanded over time, so that the Co-op has operated for a lengthy period in all areas previously leased by the CCC/USDA (Figure S.1). The Co-op began expanding onto the former CCC/USDA property in 1969 and has operated on that property longer than the CCC/USDA did. The use of carbon tetrachloride as a grain fumigant was standard industry practice until 1985, when the compound was banned by the U.S. Environmental Protection Agency. {sm_bullet} Petroleum-related contamination was detected on the southern part of the former CCC/USDA property. This contamination is associated with aboveground storage tanks that are owned and operated by the Co-op. The major findings of the 2006 investigations are summarized in greater detail below. The 2006 investigation was implemented by the Environmental Science Division of Argonne National Laboratory on behalf of the CCC/USDA.

54 ENVIRONMENTAL SCIENCES↗