Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopes and Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Light-Weight Radioisotope Heater Unit (LWRHU) Historical Testing to Special Form Testing Requirements

This paper compares the Light-Weight Radioisotope Heater Unit (LWRHU) historical testing to Department of Transportation (DOT) Special Form criteria per 49 CFR Part 173, Shippers-General Requirements for Shipments and Packages, Section 469, Tests for special form Class 7 (radioactive) materials as specified in DOE-STD-1027, Hazard Categorization of DOE Nuclear Facilities. Compliance with the aforementioned criteria allows for the exclusion of radioactive sources from the facility’s nuclear material inventory. As part of a new program at Los Alamos National Laboratory (LANL), LWRHUs are planned to be moved into TA-55, PF-5 Power Source Assembly Area (PSAA) for assembly and testing activities. The PSAA Facility is categorized as a low hazard, non-nuclear facility per DOE STD-1027 and is described in TA55-PF-5-FHC-11-001, Facility Hazard Categorization of the PSAA at PF-5, TA-55. The Facility Hazard Categorization document states, there must be documentation that radioactive sources are engineered to pass the special form testing specified by DOT in 49 CFR 173.469, Tests for special form Class 7 (radioactive) materials or ANSI N43.6, Sealed Radioactive Sources - Classification. This paper documents the extensive historical environmental safety testing of the LWRHU and demonstrates its ability to survive potential launch safety accident scenarios. The testing results are used herein to demonstrate through a comparative analysis that the robust design of the LWRHU meets or exceeds the special form testing specifications in 49 CFR 173.469, enabling the LWRHU to be transported and handled in PF-5 in support of testing and assembly program.

07 ISOTOPE AND RADIATION SOURCES↗

Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation

The updated Hanford Site Composite Analysis (CA) (DOE/RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020)) provides an all-pathways dose projection to a hypothetical future member of the public from all planned low-level radioactive waste disposal facilities and potential contributions from all other projected end-state sources of radioactive material left at the Hanford Site following site closure. Its primary purpose is to support the decision-making process of the U.S. Department of Energy (DOE) under DOE O 435.1-1, Radioactive Waste Management, related to managing low-level waste disposal facilities at the Hanford Site. A key aspect of conducting a CA is selecting the radionuclides to be analyzed. This document describes the selection process for radionuclides to be included in the quantitative analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Iodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program

In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.

07 ISOTOPE AND RADIATION SOURCES↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Radon Survey of Los Alamos National Laboratory Buildings and Los Alamos County Residential Buildings

A radon survey of office spaces was of interest to LANL for several reasons. First, exposure to natural radon in LANL office spaces has been considered to be outside the regulatory reach of the federal regulations and the U.S. Department of Energy (U.S. DOE) orders, and thus has not been studied as extensively as occupational exposure to other radionuclides and is not subject to the same rigorous radiological controls. Second, a general survey of radon concentrations in LANL workspaces was of interest to management to ensure safe environments for workers and is in keeping with the intent of OSHA requirements. Though radon in LANL offices would not be derived from enhanced radioactive sources, radon exposure in general office spaces has the potential to significantly impact worker risk. The purpose of the 2009 radon survey was to measure and document indoor radon levels across a broad spectrum of office-type workspaces and neighboring homes. The measured concentrations were compared against those measured across the United States and across the world. The results were also compared against a wide variety of radiation protection thresholds such as (1) the action levels of 148 Bq m -3 (the U.S. EPA action level for public housing), (2) ≈1,200 Bq m -3 OSHA threshold for office spaces, (3) effective dose threshold of 1 mSv threshold for defining a radiological worker, (4) 50 mSv occupational effective dose limit, and (5) 0.1 mSv and 1 mSv limits for public exposures from the air pathway and all pathways, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

CRADA Number NFE-19-07859 with Purist, Inc. (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07859 between Oak Ridge National Laboratory (ORNL) and Purist Inc. (Purist) focused on developing a technology for production of high purity radioisotopes using small-scale underutilized research nuclear reactors. Purist is developing a novel production mechanism that will produce, and efficiently isolate radioisotopes with high specific activity at small-scale research reactors. The goal of this technology is to enable underutilized smaller scale reactors, typically not capable of producing medical grade radioisotopes, to be utilized as a production supply source. Such radioisotope production facilities will complement production efforts of the few larger production facilities to reduce and prevent risk in the medical isotope supply chain. The work done under this CRADA explored target development, to maximize isotope production and separation using Purist’s technology to ultimately obtain a radioisotope product with high specific activity for use in medical applications. Furthermore, under this CRADA post production, capture, concentration and encapsulation of the radioisotope product was studied by developing post irradiation midi to microscale processes to capture, store and release the separated radioisotopes from large volumes of the capture matrix after production, via automated High-Pressure Ion Chromatography (HPIC) and microfluidic purification/separation systems. This will enable concentration of the radioisotope product obtained into small volumes, which will aid in packaging and transporting the final radioisotope product to users.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the Radiological Characterization for Off-Site Source Recovery Program Waste Streams LA-OS-00-01.001, LA-OS-00-03, and LA-OS-00-04

The purpose of this memorandum is to satisfy the requirements of Section 4.4 of the CCP Acceptable Knowledge Documentation procedure CCP-TP-005 (Ref. 1). This evaluation is updating the previously issued memo NEN3:24-045 issued in August 2024. CCP-TP-005 requires an AK Expert and the OSRP group to evaluate the radionuclide characterization of a waste stream and prepare the NDA Memorandum (letter to CCP Records). This NDA memorandum was written with input from the OSRP group, as required by CCP-TP-005. This memo includes a discussion of the limitations for the radiological characterization and a description of the characterization method.

07 ISOTOPE AND RADIATION SOURCES↗

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

07 ISOTOPE AND RADIATION SOURCES↗

First on-line detection of radioactive fission isotopes produced by laser-accelerated protons

Abstract The on-going developments in laser acceleration of protons and light ions, as well as the production of strong bursts of neutrons and multi- $$\hbox {MeV}$$ MeV photons by secondary processes now provide a basis for novel high-flux nuclear physics experiments. While the maximum energy of protons resulting from Target Normal Sheath Acceleration is presently still limited to around $$100 \, \hbox {MeV}$$ 100 MeV , the generated proton peak flux within the short laser-accelerated bunches can already today exceed the values achievable at the most advanced conventional accelerators by orders of magnitude. This paper consists of two parts covering the scientific motivation and relevance of such experiments and a first proof-of-principle demonstration. In the presented experiment pulses of $$200 \, \hbox {J}$$ 200 J at $$\approx \, 500 \, \hbox {fs}$$ ≈ 500 fs duration from the PHELIX laser produced more than $$10^{12}$$ 10 12 protons with energies above $$15 \, \hbox {MeV}$$ 15 MeV in a bunch of sub-nanosecond duration. They were used to induce fission in foil targets made of natural uranium. To make use of the nonpareil flux, these targets have to be very close to the laser acceleration source, since the particle density within the bunch is strongly affected by Coulomb explosion and the velocity differences between ions of different energy. The main challenge for nuclear detection with high-purity germanium detectors is given by the strong electromagnetic pulse caused by the laser-matter interaction close to the laser acceleration source. This was mitigated by utilizing fast transport of the fission products by a gas flow to a carbon filter, where the $$\upgamma$$ γ -rays were registered. The identified nuclides include those that have half-lives down to $$39 \, \hbox {s}$$ 39 s . These results demonstrate the capability to produce, extract, and detect short-lived reaction products under the demanding experimental condition imposed by the high-power laser interaction. The approach promotes research towards relevant nuclear astrophysical studies at conditions currently only accessible at nuclear high energy density laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Pu-238 Production Progress at Idaho National Laboratory From December 2022 to December 2023

Idaho National Laboratory (INL) has an ongoing effort to produce Pu-238 for NASA deep space missions. Recent work at INL has consisted of irradiation of Pu 238 production targets in the Advanced Test Reactor (ATR), generating more than an estimated 400 grams of Pu-238 heat source material between March and October 2023. Additionally, INL began qualifying Pu-238 production targets with a higher loading of Np-237 to further increase the production of Pu-238 production in later years. INL has also updated the analysis as a result of operational changes at ATR. One instance was updating the analysis to enable a single Pu-238 production target to be run in ATR’s South Flux Trap (SFT), rather than the previous seven production targets, to make use of a spare target from a discontinued design. Higher lobe powers in ATR were also analyzed due to potential changes in planned lobe powers.

07 ISOTOPE AND RADIATION SOURCES↗

Pu-238 Production Progress at INL From December 2022 to December 2023

Idaho National Laboratory (INL) has an ongoing effort to produce Pu-238 for NASA deep space missions. Recent work at INL has consisted of irradiation of Pu 238 production targets in the Advanced Test Reactor (ATR), generating more than an estimated 400 grams of Pu-238 heat source material between March and October 2023. Additionally, INL began qualifying Pu-238 production targets with a higher loading of Np-237 to further increase the production of Pu-238 production in later years. INL has also updated the analysis as a result of operational changes at ATR. One instance was updating the analysis to enable a single Pu-238 production target to be run in ATR’s South Flux Trap (SFT), rather than the previous seven production targets, to make use of a spare target from a discontinued design. Higher lobe powers in ATR were also analyzed due to potential changes in planned lobe powers.

07 ISOTOPE AND RADIATION SOURCES↗

Harvesting Isotopically Pure Ac-225 from Ra-225 Produced in Thorium Target Spallation Reaction

A method for isolating Ra-225 from linear accelerator irradiated Th metal chemical processing waste streams has been established. Separating Ra-225 from the complex matrix following proton irradiation of Th metal provides a source of isotopically pure Ac-225 free of the Ac-227 impurity that is present in accelerator-produced Ac-225. Ra isotopes are first separated from the irradiated Th target via cation exchange methods. Importantly, the Ra-containing fraction is cleaned from residual citrate via dilute nitric acid washes (0.5 M) on AG50W-X8 resin. The mixed Ra isotopes are then further purified from Ba-140 impurity using a Sr resin column. Ra elutes through the resin with successive washes of 2.5 M HNO 3 while Ba-140 is retained. Ac-225 is then harvested by loading the Ra content onto an AG50W-X8 cation exchange column where the Ra-225 parent is eluted with 2.5 M HNO 3 before the Ac-225 daughter is eluted with 8 M HNO 3 .

07 ISOTOPE AND RADIATION SOURCES↗

Measuring Neptunium Concentration using Optical Spectrometry for the Pu-238 Supply Program

Targets containing 237 Np are irradiated at the High Flux Isotope Reactor at Oak Ridge National Laboratory to produce 238 Pu, as plutonium dioxide (PuO 2 ), a heat source material for use in future NASA space missions. Kilogram quantities of Np are processed yearly and developing methods to efficiently characterize and monitor the Np processing streams with optical spectroscopy and real-time monitoring software is a critical aspect of this effort. Here, we evaluate how ultraviolet/visible/near-infrared (UV-Vis-NIR) absorbance and Raman spectroscopic techniques are applicable to characterizing concentrated Np solutions and provide proof-of-principle and proof-of-concept results for each technique. Both techniques were tested in lab-scale studies and should improve the timeliness of production efforts. However, spectrophotometry is the more mature option and has been successfully demonstrated in a hot cell environment. An overview of the initial findings, a brief demonstration, and areas for future work will be highlighted in this report.

07 ISOTOPE AND RADIATION SOURCES↗

Northstar Mo100 Target Beam Spot Size Sensitivity Study

Northstar Mo100 target for production of the medical isotope Mo99 is particularly sensitive to beam over focusing because of the intended high power density. At 38 MeV and 6.32 mA (240 kW beam power, nominally 160 kW th in the target), small deviation from the nominal 12 mm FWHM beam can significantly increase the target disk temperatures and more importantly the load bearing target window temperature. A rhodotron will be the source of the electron beam to be used in the isotope production. This machine operates in a pulsed beam mode, currently expected to be at 50 Hz, which results in a 100 C temperature oscillation above and below the steady state temperature that is the focus of this study. This must be considered in the determination of minimum beam spot size that can be accepted by the target without risk of failure. In addition to the nominal beam spot size of 12 mm, the analysis of 10, 11 and 14.5 mm beam spot sizes are analyzed. The primary conclusion is that an over focused beam to just 11 mm FWHM is the minimum beam spot allowable, based on window temperature and the Ultimate Tensile Stress (UTS) of the window material Inconel 718 as a function of temperature. In contrast an under focused beam of 14.5 mm FWHM has much reduced target and window temperatures, but there is a resulting 6% drop in isotope production, all other factor staying the same. These results are presented herein.

07 ISOTOPE AND RADIATION SOURCES↗

Integration of High-Z Converter into Full-scale Production Target for Accelerator-based Production of 99 Mo

NorthStar Medical Technologies is planning to produce the 99Mo isotope via the photonuclear route. The Rhodotron accelerator designed by IBA will be used as an electron-beam source. The Rhodotron is an efficient recirculating accelerator, providing low energy dispersion and a low-emittance electron beam. The nominal beam power is assumed to be 120 kW at 40 MeV. In photonuclear production of 99 Mo, a high-power electron beam impinges on a helium-cooled Mo disk target. Electrons are converted into photons through the Bremsstrahlung process. Consequently, high-energy photons interact with the target nuclei, producing 99 Mo through the 100 Mo(γ, n) 99 Mo reaction. Traditionally, photonuclear production is realized using high-Z material as the electron-to-photon converter. NorthStar plans not to use a high-Z converter in the initial production target design, but it may be interested in the increased production capabilities a high-Z converter can provide. The purpose of this report is to evaluate the advantages and disadvantages of incorporating a high-Z converter into the target design.

07 ISOTOPE AND RADIATION SOURCES↗