Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The International Solar Polar Mission - United States and Europe plan for a new look at the sun

A three-dimensional polar orbit exploration of the sun and solar-related phenomena in the heliosphere through the International Solar Polar Mission (ISPM) is discussed. The characteristics of the out-of-the-ecliptic mission are mentioned and a detailed list of the scientific objectives is given: properties of the solar corona, the solar wind, the structure of the sun-wind interface, the heliospheric magnetic field, solar and non-solar cosmic rays, solar radio bursts and plasma waves, and the interstellar/interplanetary neutral gas and dust. Measurements of the Jovian magnetosphere during the Jupiter flyby phase and interplanetary physics investigations during the initial earth-Jupiter phase are pointed out as secondary objectives. The Nasa spacecraft with a sun-pointing despun platform on which the White Light Coronagraph/X-Ray and Extreme Ultraviolet Telescope (CXX), and the Mass Separating Ion Instrument are mounted, is detailed. The operational configuration of EASA, a spin stabilized spacecraft, is given and characteristics of special features such as the large paraboloidal high gain antenna, the radio-isotope thermoelectric generator, the radial boom and the central equipment compartment are described and shown in a diagram. The mission design and launch parameters block diagrams are given.

Purdy, W. I., Jr.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.

Shelley, Jacob T.↗

Alkaline anion exchange membranes derived from diphenylethylene and co-monomer feedstock

The anion exchange membranes exhibit enhanced chemical stability and ion conductivity when compared with traditional styrene-based alkaline anion exchange membranes. A copolymer backbone is polymerized from a reaction medium that includes a diphenylalkylene and an alkadiene. The copolymer includes a plurality of pendant phenyl groups. The diphenyl groups on the polymer backbone are functionalized with one or more haloalkylated precursor substrates. The terminal halide from the precursor substrate can then be substituted with a desired ionic group. The diphenylethylene-based alkaline anion exchange membranes lack the .alpha.-hydrogens sharing tertiary carbons with phenyl groups from polystyrene or styrene-based precursor polymers, resulting in higher chemical stability. The ionic groups are also apart from each other by about 3 to 6 carbons in the polymer backbone, enhancing ion conductivity. These membrane are advantageous for use in fuel cells, electrolyzers employing hydrogen, ion separations, etc.

Lee, Sangwoo↗

Thermally stable hydrocarbon-based anion exchange membrane and ionomers

An anion exchange membrane is composed of a copolymer of 1,1-diphenylethylene and one or more styrene monomers, such as 4-tert-butylstyrene. The copolymer includes a backbone substituted with a plurality of ionic groups coupled to phenyl groups on the backbone via hydrocarbyl tethers between about 1 and about 7 carbons in length. High-temperature conditions enabled by these copolymers enhance conductivity performance, making them particularly suitable for use in anion exchange membranes in fuel cells, electrolyzers employing hydrogen, ion separations, etc. The properties of the membranes can be tuned via the degree of functionalization of the phenyl groups and selection of the functional groups, such as quaternary ammonium groups. Several processes can be used to incorporate the desired ionic functional groups into the polymers, such as chloromethylation, radical bromination, Friedel-Crafts acylation and alkylation, sulfonation followed by amination, or combinations thereof.

Lee, Sangwoo↗

Alkaline anion exchange membranes derived from diphenylethylene and co-monomer feedstock

The anion exchange membranes exhibit enhanced chemical stability and ion conductivity when compared with traditional styrene-based alkaline anion exchange membranes. A copolymer backbone is polymerized from a reaction medium that includes a diphenylalkylene and an alkadiene. The copolymer includes a plurality of pendant phenyl groups. The diphenyl groups on the polymer backbone are functionalized with one or more haloalkylated precursor substrates. The terminal halide from the precursor substrate can then be substituted with a desired ionic group. The diphenylethylene-based alkaline anion exchange membranes lack the α-hydrogens sharing tertiary carbons with phenyl groups from polystyrene or styrene-based precursor polymers, resulting in higher chemical stability. The ionic groups are also apart from each other by about 3 to 6 carbons in the polymer backbone, enhancing ion conductivity. These membrane are advantageous for use in fuel cells, electrolyzers employing hydrogen, ion separations, etc.

Lee, Sangwoo↗

Thermally stable hydrocarbon-based anion exchange membrane and ionomers

An anion exchange membrane is composed of a copolymer of 1,1-diphenylethylene and one or more styrene monomers, such as 4-tert-butylstyrene. The copolymer includes a backbone substituted with a plurality of ionic groups coupled to phenyl groups on the backbone via hydrocarbyl tethers between about 1 and about 7 carbons in length. High-temperature conditions enabled by these copolymers enhance conductivity performance, making them particularly suitable for use in anion exchange membranes in fuel cells, electrolyzers employing hydrogen, ion separations, etc. The properties of the membranes can be tuned via the degree of functionalization of the phenyl groups and selection of the functional groups, such as quaternary ammonium groups. Several processes can be used to incorporate the desired ionic functional groups into the polymers, such as chloromethylation, radical bromination, Friedel-Crafts acylation and alkylation, sulfonation followed by amination, or combinations thereof.

Lee, Sangwoo↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Important Role of Ion Flux Regulated by Separators in Lithium Metal Batteries

Abstract Polyolefin separators are the most common separators used in rechargeable lithium (Li)‐ion batteries. However, the influence of different polyolefin separators on the performance of Li metal batteries (LMBs) has not been well studied. By performing particle injection simulations on the reconstructed three‐dimensional pores of different polyethylene separators, it is revealed that the pore structure of the separator has a significant impact on the ion flux distribution, the Li deposition behavior, and consequently, the cycle life of LMBs. It is also discovered that the homogeneity factor of Li‐ion toward Li metal electrode is positively correlated to the longevity and reproducibility of LMBs. This work not only emphasizes the importance of the pore structure of polyolefin separators but also provides an economic and effective method to screen favorable separators for LMBs.

25 ENERGY STORAGE↗

Polymeric ionic liquids containing copper(I) and copper(II) ions as gas chromatographic stationary phases for olefin separations

Copper(I) ions (Cu + ) are used in olefin separations due to their olefin complexing ability and low cost, but their instability in the presence of water and gases limits their widespread use. Ionic liquids (ILs) have emerged as stabilizers of Cu + ions and prevent their degradation, providing high olefin separation efficiency. There is limited understanding into the role that polymeric ionic liquids (PILs), which possess similar structural characteristics to ILs, have on Cu + ion-olefin interactions. Moreover, copper ions with diverse oxidation states, including Cu + and Cu 2+ ions, have been rarely employed for olefin separations. In this study, gas chromatography (GC) is used to investigate the interaction strength of olefins to stationary phases composed of the 1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 6 MIM + ][NTf 2 – ]) IL and the poly(1-hexyl-3-vinylimidazolium [NTf 2 – ]) (poly([C 6 VIM + ][NTf 2 – ])) PIL containing monovalent and divalent copper salts (i.e., [Cu + ][NTf 2 – ] and [Cu 2+ ]2[NTf 2 – ]). The chromatographic retention of alkenes, alkynes, dienes, and aromatic compounds was examined. Incorporation of the [Cu 2+ ]2[NTf 2 – ] salt into a stationary phase comprised of poly(dimethylsiloxane) resulted in strong retention of olefins, while its addition to the [C 6 MIM + ][NTf 2 – ] IL and poly([C 6 VIM + ][NTf 2 – ]) PIL allowed for the interaction strength to be modulated. Olefins exhibited greater affinities toward IL and PIL stationary phases containing the [Cu 2+ ]2[NTf 2 – ] salt compared to those with the [Cu + ][NTf 2 – ] salt. Elimination of water from both copper salts was observed to be an important factor in promoting olefin interactions, as evidenced by increased olefin retention upon exposure of the stationary phases to high temperatures. Furthermore, to evaluate the long-term thermal stability of the stationary phase, chromatographic retention of probes was measured on the [Cu 2+ ]2[NTf 2 – ]/[C 6 MIM + ][NTf 2 – ] IL stationary phase after its exposure to helium at a temperature of 110°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion-exchange chromatography separates activities synthesizing and degrading fructose 2,6-bisphosphate from C3 and C4 leaves but not from rat liver

Fructose-6-phosphate,2-kinase and fructose-2,6-bisphosphatase were separated on the basis of charge from leaves of C3 (spinach, lettuce, and pea) and C4 (sorghum and amaranthus) plants but not from rat liver--a tissue known to contain a bifunctional enzyme with both activities. [2-32P]Fructose 2,6-bisphosphate binding experiments also suggest that the major forms of these activities reside on different proteins in leaves.

NASA Discipline Exobiology↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

Electrolyte Compatible Separator Materials for Sodium-Ion Battery

Sodium-ion batteries (NIBs) have emerged as an alternative electrochemical energy storage to replace lithium-ion batteries (LIBs). Separator is one of the key components that dictates the cell performance of NIB. Significant progress has been made in electrolyte research, however for most cases glass fiber has been used as separator due to its remarkable electrolyte wettability despite its many disadvantages. In this study, we evaluated commercially available porous materials as separator material for NIB. Porous polyvinylidene fluoride (PVDF) membrane stands out as a universal separator which exhibits high compatibility with a wide range of electrolytes and electrodes and demonstrates high electrochemical stability evaluated in hard carbon/Na half cells and NaNi 1/3 Fe 1/3 Mn 1/3 O 2 (NFM111)/hard carbon full cells. This research highlights the PVDF membrane as a viable separator for advancing NIB research, enabling the development of new electrolyte materials without the separator constraints of wetting limitations or excessive electrolyte consumption.

Wostoupal, Owen S. [Argonne National Laboratory (A↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗