Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC-Link Capacitor Design for a Neutral-Point-Less Three-Level Dual-Phase Inverter for Traction Application

Conventional multilevel inverters, such as neutral￾point-clamped and T-type inverters, have gained popularity in electric vehicle applications due to their advantages, including high voltage range, high power capability, low switching losses, low total harmonic distortion, and low electromagnetic interference. However, these traditional multilevel inverters require a neutral point connection to generate a zero-voltage vector. The neutral point current oscillates at three times the fundamental frequency, leading to voltage imbalance and overvoltage stress on the power modules. Additionally, the use of two stacked DC-link capacitors increases the volume required for the same overall capacitance and complicates packaging due to ripple current and heat dissipation from separate components. This is a significant concern for traction drive units, where space is limited. In this paper, a neutral-point-less multilevel dual three￾phase inverter topology is investigated for traction inverter applications. Simulation results demonstrate that the proposed topology effectively retains the benefits of multilevel operation while utilizing a single DC-link capacitor. The inverter model was simulated in conjunction with an industry-standard battery model to evaluate the potential for capacitor size reduction compared to a conventional three-level inverter.

33 ADVANCED PROPULSION SYSTEMS↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Lyapunov stability of smart inverters using linearized distflow approximation

Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt–Var and Volt–Watt control curves are used to analytically derive a stability criterion using Lyapunov analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be represented as Lipschitz functions. The derived Lipschitz constants account for smart inverter hardware limitations for reactive power generation. A local policy is derived from the stability criterion that allows inverters to adapt their control curves by monitoring only local voltage, thus avoiding centralized control or information sharing with other inverters. The criterion is independent of the internal time-delays of smart inverters. Simulation results for inverters with and without the proposed stabilization technique demonstrate how smart inverters can mitigate voltage oscillations locally and mitigate real and reactive power flow disturbances at the substation under multiple scenarios. The study concludes with illustrations of how the control policy can dampen oscillations caused by solar intermittency and cyberattacks.

42 ENGINEERING↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Cooperative Inverters to Overcome PLL Malfunctions

This paper presents a cooperative strategy between smart inverters to overcome instability and undesired trips of inverters caused by Phase-Locked Loop (PLL) malfunctions. For the grid-interactive inverter, PLL is typically required to measure the phase angle of the AC voltage at the Point of Common Coupling (PCC) of the inverter. Accurate phase-angle measurement is critical for grid-interactive inverters to stay synchronized with the power grid. If the inverters are interconnected through a communication link, they can support each other by sharing their grid information, such as phase-angles at their PCCs. The cooperative strategy utilizes the phase-angles and voltages at PCCs in a neighborhood to identify any possible PLL malfunctions or measurement inaccuracies and then enable the inverters to make corrective decisions. The efficacy of the cooperative strategy has been verified through simulation results in MATLAB/Simulink environment in this paper.

Sadeque, Fahmid↗

Deep Learning-Based Failure Prognostic Model for PV Inverter Using Field Measurements

Here, this study presents a novel approach for the precise monitoring and prognosis of photovoltaic (PV) inverter status, which is crucial for the proactive maintenance of PV systems. It addresses the gaps in traditional model-based methods, which tend to neglect the overall reliability of inverters, and the limitations of data-driven approaches that largely depend on simulated data. This research presents a robust solution applicable to real-world scenarios. The proposed data-driven model for PV inverter failure prognosis employs actual inverter measurements, integrating various operational and weather-related factors based on domain knowledge. This approach effectively represents inverter stressors and operational status. Utilizing an Enhanced Siamese Convolutional Neural Network (ESCNN), the model merges operational data with domain knowledge features, redefining the prognosis challenge as a classification task. Furthermore, the paper discusses an ESCNN-based real-time inverter failure monitoring method developed on the well-trained model. The proposed models are rigorously trained and tested with real inverter data and a novel filtering method is included to address accidental failures in practical scenarios. The results validate the model's efficacy, and the directions for future research are also outlined.

42 ENGINEERING↗

Anomalies of non-invertible symmetries in (3+1)d

Anomalies of global symmetries are important tools for understanding the dynamics of quantum systems. We investigate anomalies of non-invertible symmetries in 3+1d using 4+1d bulk topological quantum field theories given by Abelian two-form gauge theories, with a 0-form permutation symmetry. Gauging the 0-form symmetry gives the 4+1d “inflow” symmetry topological field theory for the non-invertible symmetry. We find a two levels of anomalies: (1) the bulk may fail to have an appropriate set of loop excitations which can condense to trivialize the boundary dynamics, and (2) the “Frobenius-Schur indicator” of the non-invertible symmetry (generalizing the Frobenius-Schur indicator of 1+1d fusion categories) may be incompatible with trivial boundary dynamics. As a consequence we derive conditions for non-invertible symmetries in 3+1d to be compatible with symmetric gapped phases, and invertible gapped phases. Along the way, we see that the defects characterizing \mathbb{Z}_{4} ℤ 4 ordinary symmetry host worldvolume theories with time-reversal symmetry \mathsf{T} 𝖳 obeying the algebra \mathsf{T}^{2}=C 𝖳 2 = C or \mathsf{T}^{2}=(-1)^{F}C, 𝖳 2 = ( − 1 ) F C , with C C a unitary charge conjugation symmetry. We classify the anomalies of this symmetry algebra in 2+1d and further use these ideas to construct 2+1d topological orders with non-invertible time-reversal symmetry that permutes anyons. As a concrete realization of our general discussion, we construct new lattice Hamiltonian models in 3+1d with non-invertible symmetry, and constrain their dynamics.

Córdova, Clay↗

(SPT-)LSM theorems from projective non-invertible symmetries

Projective symmetries are ubiquitous in quantum lattice models and can be leveraged to constrain their phase diagram and entanglement structure. In this paper, we investigate the consequences of projective algebras formed by non-invertible symmetries and lattice translations in a generalized 1+1 1 + 1 D quantum XY model based on group-valued qudits. This model is specified by a finite group G G and enjoys a projective \mathsf{Rep}(G)× Z(G) 𝖱 𝖾 𝗉 ( G ) × Z ( G ) and translation symmetry, where symmetry operators obey a projective algebra in the presence of symmetry defects. For invertible symmetries, such projective algebras imply Lieb-Schultz-Mattis (LSM) anomalies. However, this is not generally true for non-invertible symmetries, and we derive a condition on G G for the existence of an LSM anomaly. When this condition is not met, we prove an SPT-LSM theorem: any unique and gapped ground state is necessarily a non-invertible weak symmetry protected topological (SPT) state with non-trivial entanglement, for which we construct an example fixed-point Hamiltonian. The projectivity also affects the dual symmetries after gauging \mathsf{Rep}(G)× Z(G) 𝖱 𝖾 𝗉 ( G ) × Z ( G ) sub-symmetries, giving rise to non-Abelian and non-invertible dipole symmetries, as well as non-invertible translations. We complement our analysis with the SymTFT, where the projectivity causes it to be a topological order non-trivially enriched by translations. Throughout the paper, we develop techniques for gauging \mathsf{Rep}(G) 𝖱 𝖾 𝗉 ( G ) symmetry and inserting its symmetry defects on the lattice, which are applicable to other non-invertible symmetries.

Pace, Salvatore D. (ORCID:0000000306093335)↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments: Preprint

Existing state-of-the-art of single-phase grid-forming (GFM) inverter are primarily focused on electromagnetic transient simulation, and there are very few works performing hardware test, and there is no clear understanding how the single-phase GFM inverter should behave from a hardware perspective. Therefore, this paper addresses the gap by performing hardware experiment to evaluate the performance of a single-phase GFM hardware inverter. We enrich the existing GFM testing protocols by investigating transient performance of GFM inverters under different grid dynamic events, and quantifiable performance metrics are made to have a common understanding of expected performance of single-phase GFM inverters. A commercial single-phase GFM inverter is used to verify the test protocols and understand the inverter's performance and functionalities.

dynamic events↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Enhanced Performance of Dual Inverter with a Floating Capacitor for Motor Drive Applications

This paper studies a dual inverter supplied by a DC-link and a floating capacitor (FC), emerged as a promising inverter topology for motor drive applications. For this type of inverter, the voltage ratio between the DC-link and the FC can be actively controlled. This ratio design is crucial as it essentially defines both the DC-link voltage utilization and the inverter output quality. Several voltage ratios have previously been discussed to enhance the dual inverter performance, but only one aspect, either the voltage utilization or the output quality, is investigated. As a result, although one performance aspect can be improved, the other aspect has been adversely affected. In this work, a comparative study considering both aspects is carried out for all the possible voltage ratios. Based on this analysis, the optimal ratios for different inverter modulation indices are identified. This is followed by proposing a ratio selection strategy to double the voltage utilization without degrading the output quality. Furthermore, this strategy enables an electric drive to work at a higher maximum speed without flux weakening for a given DC-link voltage. The claimed advantages have been proved by experimental tests on an open-end windings induction motor drive.

42 ENGINEERING↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗