Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced Method Optimization with Categorical and Constrained Continuous Parameters

Traditional approaches to analytical method optimization (e.g., univariate and “guess-and-check”) can be time-consuming, costly, and often fail to identify true optima within the parameter space. Previous work defined and implemented a generalized technique for method optimization for continuous method parameters, but a knowledge gap remains for the incorporation of categorical variables into these advanced method optimization schemes. This work presents and validates a generalized optimization approach that incorporates both continuous and categorical variables while also utilizing a multivariate, multiobjective optimization scheme with Karush–Kuhn–Tucker conditions to bound the optimization space to solutions within the physical limitations of the parameter space. Method optimization from a case study using GC–MS for the analysis of 11 analytical standards with objectives to minimize peak width and maximize peak height resulted in a 3 orders of magnitude improvement in the average peak height and a 2 orders of magnitude improvement in the average peak width compared to the least optimal (but reasonable) instrumental parameters utilized in this study. This approach to optimization allows for a customizable method optimization in which users can include both continuous and categorical variables to achieve objectives specific to their analytical goals. This approach significantly reduces the labor and cost associated with traditional method development approaches and can be applied in a variety of scientific fields across a range of laboratory techniques (e.g., instrument method development, sample preparation, and extraction techniques).

Amorphous materials↗

Analysis of Fine-Mode Aerosol Retrieval Capabilities by Different Passive Remote Sensing Instrument Designs

Remote sensing of aerosol optical properties is difficult, but multi-angle, multi-spectral, polarimetric instruments have the potential to retrieve sufficient information about aerosols that they can be used to improve global climate models. However, the complexity of these instruments means that it is difficult to intuitively understand the relationship between instrument design and retrieval success. We apply a Bayesian statistical technique that relates instrument characteristics to the information contained in an observation. Using realistic simulations of fine size mode dominated spherical aerosols, we investigate three instrument designs. Two of these represent instruments currently in orbit: the Multiangle Imaging SpectroRadiometer (MISR) and the POLarization and Directionality of the Earths Reflectances (POLDER). The third is the Aerosol Polarimetry Sensor (APS), which failed to reach orbit during recent launch, but represents a viable design for future instruments. The results show fundamental differences between the three, and offer suggestions for future instrument design and the optimal retrieval strategy for current instruments. Generally, our results agree with previous validation efforts of POLDER and airborne prototypes of APS, but show that the MISR aerosol optical thickness uncertainty characterization is possibly underestimated.

Knobelspiesse, Kirk↗

Development and Optimization of Kinematic Mounts for NIRCam: a JWST Science Instrument

Finite element analysis was vital to the design and optimization of the kinematic mounts for the Near Infrared Camera (NIRCam) instrument The design had to meet dueling structural requirements driven by 12G launch loads, a survivability of bulk cool down from room temperature to 22 K, minimum first mode of 50 Hz and mass allocation constraints. Additionally the design has to meet stability and Integrated Science Instrument Module (ISIM) interfaces when cooled to 22K.

Young, Daniel↗

Communication-Aware Orbit Design for Small Spacecraft Swarms around Small Bodies

Exploration of small Solar System bodies has traditionally been performed by single monolithic spacecraft carrying a number of science instruments. However, science instruments typically cannot be operated simultaneously due to the instrument requirements including optimal viewing angle, surface illumination, altitude and ground resolution, power, and data constraints. This observation has motivated interest in multi-spacecraft architectures where a swarm of small spacecraft, each carrying a single science instrument, studies a small body after being deployed by a carrier spacecraft, which then collects data from the vehicles and relays it to Earth. Such architectures hold promise to yield significant improvements in mission efficiency, increases in data quality, and shorter mission duration. A key difficulty in the design of such missions is the selection of orbits for the small spacecraft, which must satisfy not only instrument requirements, but also strict inter-spacecraft communication and on-board storage constraints. To address this, in this paper, we present a novel computationally-efficient optimization algorithm for \emph{communication-aware design} of the orbits of a small spacecraft swarm orbiting a small body. The proposed approach captures constraints including instrument requirements, inter-spacecraft communication bandwidths, and on-board memory usage, and it can accommodate highly irregular gravity field models and surface geometries. We propose an efficient algorithm for optimization of instrument observations and inter-spacecraft communications; we then leverage the differentiable nature of the proposed algorithm to accelerate a gradient-based global search algorithm. Numerical simulations of a six-spacecraft swarm studying 433 Eros show that the proposed approach successfully identifies high-quality orbits, and significantly outperform communication-agnostic optimization techniques, resulting in a 10% increase in scientific returns and a 30% increase in the quality of the collected data.

Rahmani, Amir↗

Structured-groove phase gratings for control and optimization of the spectral efficiency

Phase gratings are used as dispersers in a variety of imaging spectroscopic instruments. However, conventional phase gratings provide limited spectral range and flexibility to fully optimize instrument performance for challenging applications. Presented here is a new design method that tailors and optimizes the spectral efficiency by introducing an arbitrary structure into the grating groove profile.

diffraction gratings↗

A unified approach to aircraft parameter identification

The most accurate identification results are obtained when all three elements of the identification process - the identification algorithm, the control input, and the instrumentation system - are considered in a unified approach. This type of approach for the design of optimal control inputs and for determining the effect of the instrumentation system, in each case with respect to the identification process is discussed. Design of control inputs which optimize the sensitivity of the system output to the unknown parameters is given. Results using these inputs in an extensive simulation of the identification process indicate they perform measurably better than doublet type inputs. A technique is then presented for specifying an optimal instrumentation system or for determining the effect, the instrumentation system has on the accuracy of the parameter estimates.

Stepner, D. E.↗

STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study

New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.

Kunt, Cengiz↗

Simulating and benchmarking neutron total scattering instrumentation from inception of events to reduced and fitted data

In the design and realization of modern neutron scattering instrumentation, particularly when designing beamline concepts from the ground up, it is desirable to fully benchmark against realistically simulated data. This is especially true for total scattering beamlines, where the future deliverable data is to be analysed in both reciprocal- and real-space representations, and needs must be carefully balanced to ensure sufficient range, resolution and flux of the instrument. An approach to optimize the design of neutron scattering instrumentation via a workflow including ray-tracing simulations, event-based data reduction, heuristic analysis and fitting against realistically simulated spectra is demonstrated here. The case of the DISCOVER beamline concept at the Spallation Neutron Source is used as an example. The results of the calculations are benchmarked through simulation of existing instrumentation and subsequent direct comparison with measured data. Finally, on the basis of the validated models, the ability to explore design characteristics for future beamline concepts or future instrument improvements is demonstrated through the examples of detector tube size and detector layout.

47 OTHER INSTRUMENTATION↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

mystic : software for autonomous discovery and design under uncertainty

Throughout the diverse range of science and engineering applications, there is a growing desire to develop computational methods that can reliably predict the behavior of complex systems. Specifically, there is a strategic need for tools that can robustly forecast the behavior of complex physical systems, where data may be high-dimensional, noisy, or sparse, and models of the system may be time-dependent or include uncertainty. We use mystic to build tools that leverage statistical learning, physics-informed learning, and active learning in the efficient generation of reliably predictive surrogates for complex physical systems. mystic is a robust, proven, open-source optimization and uncertainty quantification toolkit with over a decade of use in the design and optimization of neutron instrumentation, solar-powered drones, and gasguns, and in iterative tuning of models for Raman spectroscopy and elastoplastic materials strength. Recent developments have focused on automated learning of statistically robust surrogates under uncertainty, with applications in materials in extreme environments, nanostructures, materials simulations and strength models, and the failure of shielding under particle radiation. In 2020, McKerns demonstrated active learning of optimally robust surrogates with respect to new simulated data for molecular dynamics simulations of materials mixing in warm dense matter, and is currently applying active learning to the automated steering of particle accelerator beams and the optimal design and control of quantum optical sensor instrumentation.

42 ENGINEERING↗

Progress in end-to-end optimization of fundamental physics experimental apparata with differentiable programming

In this article we examine recent developments in the research area concerning the creation of end-to-end models for the complete optimization of measuring instruments. The models we consider rely on differentiable programming methods and on the specification of a software pipeline including all factors impacting performance — from the data-generating processes to their reconstruction and the inference on the parameters of interest — along with the careful specification of a utility function well aligned with the end goals of the experiment. Building on previous studies originated within the MODE Collaboration, we focus specifically on applications involving instruments for particle physics experimentation, as well as industrial and medical applications that share the detection of radiation as their data-generating mechanism. This report illustrates the most recent advancements in the area, and outlines, for each of the discussed applications as well as for automatic differentiation itself, ongoing and future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on the "Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments"

An international group of researchers gathered for the “Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments” at Oak Ridge National Laboratory (ORNL) on October 29- 30, 2024. The symposium highlighted state-of-the-art advancements in neutron scattering instrument simulations and the development of digital twins for scattering instruments. This document summarizes the recurring themes from the 19 talks and discussions. A key focus was on the role of neutronics simulations in the design, analysis, and performance optimization of neutron instruments. Presentations featured the most widely used software packages, such as McStas, McVine, Vitess, and MCNP. Another major theme addressed the analysis and interpretation of experimental neutron data, where materials models and simulations play a critical role. Talks on relevant software tools, including NCrystal, OCLimax, and Paradyse, were delivered by their respective developers. During the symposium, both talks and breakout sessions explored strategies to enhance the interplay between neutronics simulations and materials models. A key question emerged: How can we develop a RealTime Explainable Digital Twin of a neutron scattering experiment? Discussions include the idea that the Digital Twin concept has implications for instrument control and testing. Through this symposium, we gained valuable insights into the challenges and requirements for developing a Real-Time Explainable Digital Twin of a neutron scattering experiment. The discussions and presentations paved the way for future innovations in this rapidly advancing field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

MSL↗

A laser velocimeter system for small radial turbomachinery

The paper describes the design and test of a laser Doppler velocimeter (LDV) to map the velocity fields in small high-speed turbomachinery. This instrument is presently being used as a diagnostic tool for the study of the basic fluid dynamics of the inducer, impeller and the diffuser regions of high-pressure-ratio small centrifugal compressors. The LDV instrumentation has been optimized to permit measurement of instantaneous velocities up to approximately 500 m/s within a rotating impeller. It is shown that LDV can make nondisturbing gas velocity measurements and surmount the difficulties found in applying other types of aerodynamic instrumentation, e.g., hot-wire anemometers, to this measurement problem.

Runstadler, P. W., Jr.↗

TES Pixel Optimization for the ATHENA X-IFU Instrument

ATHENA is a European led x-ray observatory due for launch in the early 2030s. The X-ray Integral Field Unit (X-IFU) instrument on ATHENA will have an array of 3168 TES microcalorimeters, 2.5 eV resolution (at 7 keV), 5 arc second angular resolution and a 5 arc minute field of view. As one example, will allow unprecedented views of composition and dynamics of galaxy clusters.

Wakeham, Nick↗