Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Institution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Pro-Qura-generated Plans on Postimplant Dosimetric Quality: A Review of a Multi-Institutional Database

The influence of Pro-Qura-generated plans vs. community-generated plans on postprostate brachytherapy dosimetric quality was compared. In the Pro-Qura database, 2933 postplans were evaluated from 57 institutions. A total of 1803 plans were generated by Pro-Qura and 1130 by community institutions. Iodine-125 ({sup 125}I) plans outnumbered Palladium 103 ({sup 103}Pd) plans by a ratio of 3:1. Postimplant dosimetry was performed in a standardized fashion by overlapping the preimplant ultrasound and the postimplant computed tomography (CT). In this analysis, adequacy was defined as a V{sub 100} > 80% and a D{sub 90} of 90% to 140% for both isotopes along with a V{sub 150} < 60% for {sup 125}I and < 75% for {sup 103}Pd. The mean postimplant V{sub 100} and D{sub 90} were 88.6% and 101.6% vs. 89.3% and 102.3% for Pro-Qura and community plans, respectively. When analyzed in terms of the first 8 sequence groups (10 patients/sequence group) for each institution, Pro-Qura planning resulted in less postimplant variability for V{sub 100} (86.2-89.5%) and for D{sub 90} (97.4-103.2%) while community-generated plans had greater V{sub 100} (85.3-91.2%) and D{sub 90} (95.9-105.2%) ranges. In terms of sequence groups, postimplant dosimetry was deemed 'too cool' in 11% to 30% of cases and 'too hot' in 12% to 27%. On average, no clinically significant postimplant dosimetric differences were discerned between Pro-Qura and community-based planning. However, substantially greater variability was identified in the community-based plan cohort. It is possible that the Pro-Qura plan and/or the routine postimplant dosimetric evaluation may have influenced dosimetric outcomes at community-based centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greening academia: Developing sustainable waste management at Higher Education Institutions

Higher Education Institutions (HEIs) are often the size of small municipalities. Worldwide, the higher education (HE) sector has expanded phenomenally; for example, since the 1960s, the United Kingdom (UK) HE system has expanded sixfold to >2.4 million students. As a consequence, the overall production of waste at HEIs throughout the world is very large and presents significant challenges as the associated legislative, economic and environmental pressures can be difficult to control and manage. This paper critically reviews why sustainable waste management has become a key issue for the worldwide HE sector to address and describes some of the benefits, barriers, practical and logistical problems. As a practical illustration of some of the issues and problems, the four-phase waste management strategy developed over 15 years by one of the largest universities in Southern England - the University of Southampton (UoS) - is outlined as a case study. The UoS is committed to protecting the environment by developing practices that are safe, sustainable and environmentally friendly and has developed a practical, staged approach to manage waste in an increasingly sustainable fashion. At each stage, the approach taken to the development of infrastructure (I), service provision (S) and behavior change (B) is explained, taking into account the Political, Economic, Social, Technological, Legal and Environmental (PESTLE) factors. Signposts to lessons learned, good practice and useful resources that other institutions - both nationally and internationally - can access are provided. As a result of the strategy developed at the UoS, from 2004 to 2008 waste costs fell by around Pounds 125k and a recycling rate of 72% was achieved. The holistic approach taken - recognizing the PESTLE factors and the importance of a concerted ISB approach - provides a realistic, successful and practical example for other institutions wishing to effectively and sustainably manage their waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Insiders Views of the Valley of Death Behavioral and Institutional Perspectives

Valley of death describes the metaphorical depths to which promising science and technology too often plunge, never to emerge and reach their full potential. Behavioral and institutional perspectives help in understanding the implications of choices that inadvertently lead into rather than over the valley of death. A workshop conducted among a diverse set of scientists, managers, and technology transfer staff at a U.S. national laboratory is a point of departure for discussing behavioral and institutional elements that promote or impede the pathway from research toward use, and for suggesting actionable measures that can facilitate the flow of information and products from research toward use. In the complex systems that comprise research institutions, where competing pressures can create barriers to information or technology transfer, one recommendation is to re-frame the process as a more active ushering toward use.

research translation↗

MO-G-BRE-02: A Survey of IMRT QA Practices for More Than 800 Institutions

Purpose: A wide range of techniques and measurement devices are employed for IMRT QA, causing a large variation of accepted action limits and potential follow up for failing plans. Such procedures are not well established or accepted in the medical physics community. To achieve the goal of proving insight into current IMRT QA practices, we created an electronic IMRT QA survey. The survey was open to a variety of the most common QA devices and assessed the type of comparison to measurement, action limits, delivery methods, and clinical action for failing QA plans. Methods: We conducted an online survey through the Radiological Physics Center's (RPC) annual survey with the goal of ascertaining elements of routine patient-specific IMRT QA. A total of 874 institutions responded to the survey. The questions ranged from asking for action limits, dosimeter type(s) used, delivery techniques, and actions taken when a plan fails IMRT QA. Results: The most common (52%) planar gamma criteria was 3%/3 mm with a 95% of pixels passing criteria. The most common QA device were diode arrays (48%). The most common first response to a plan failing QA was to re-measure at the same point the point dose (89%), second was to re-measure at a new point (13%), and third was to analyze the plan in relative instead of absolute mode (10%) (Does not add to 100% as not all institutions placed a response for each QA follow-up option). Some institutions, however, claimed that they had never observed a plan failure. Conclusion: The survey provided insights into the way the community currently performs IMRT QA. This information will help in the push to standardize action limits among dosimeters.

60 APPLIED LIFE SCIENCES↗

SU-E-T-48: A Multi-Institutional Study of Independent Dose Verification for Conventional, SRS and SBRT

Purpose: To show the results of a multi-institutional study of the independent dose verification for conventional, Stereotactic radiosurgery and body radiotherapy (SRS and SBRT) plans based on the action level of AAPM TG-114. Methods: This study was performed at 12 institutions in Japan. To eliminate the bias of independent dose verification program (Indp), all of the institutions used the same CT-based independent dose verification software (Simple MU Analysis, Triangle Products, JP) with the Clarkson-based algorithm. Eclipse (AAA, PBC), Pinnacle{sup 3} (Adaptive Convolve) and Xio (Superposition) were used as treatment planning system (TPS). The confidence limits (CL, Mean±2SD) for 18 sites (head, breast, lung, pelvis, etc.) were evaluated in comparison in dose between the TPS and the Indp. Results: A retrospective analysis of 6352 treatment fields was conducted. The CLs for conventional, SRS and SBRT were 1.0±3.7 %, 2.0±2.5 % and 6.2±4.4 %, respectively. In conventional plans, most of the sites showed within 5 % of TG-114 action level. However, there were the systematic difference (4.0±4.0 % and 2.5±5.8 % for breast and lung, respectively). In SRS plans, our results showed good agreement compared to the action level. In SBRT plans, the discrepancy between the Indp was variable depending on dose calculation algorithms of TPS. Conclusion: The impact of dose calculation algorithms for the TPS and the Indp affects the action level. It is effective to set the site-specific tolerances, especially for the site where inhomogeneous correction can affect dose distribution strongly.

60 APPLIED LIFE SCIENCES↗

SU-E-T-49: A Multi-Institutional Study of Independent Dose Verification for IMRT

Purpose: AAPM TG114 does not cover the independent verification for IMRT. We conducted a study of independent dose verification for IMRT in seven institutes to show the feasibility. Methods: 384 IMRT plans in the sites of prostate and head and neck (HN) were collected from the institutes, where the planning was performed using Eclipse and Pinnacle3 with the two techniques of step and shoot (S&S) and sliding window (SW). All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. An ion-chamber measurement in a water-equivalent slab phantom was performed to compare the doses computed using the TPS and an independent dose verification program. Additionally, the agreement in dose computed in patient CT images between using the TPS and using the SMU was assessed. The dose of the composite beams in the plan was evaluated. Results: The agreement between the measurement and the SMU were −2.3±1.9 % and −5.6±3.6 % for prostate and HN sites, respectively. The agreement between the TPSs and the SMU were −2.1±1.9 % and −3.0±3.7 for prostate and HN sites, respectively. There was a negative systematic difference with similar standard deviation and the difference was larger in the HN site. The S&S technique showed a statistically significant difference between the SW. Because the Clarkson-based method in the independent program underestimated (cannot consider) the dose under the MLC. Conclusion: The accuracy would be improved when the Clarkson-based algorithm should be modified for IMRT and the tolerance level would be within 5%.

60 APPLIED LIFE SCIENCES↗

SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencil Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-03: Cross-Institutional Validation of An Ultrafast Automatic Planning Platform for Breast Irradiation

Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.

60 APPLIED LIFE SCIENCES↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-03: The Ottawa Medical Physics Institute (OMPI): A Practical Model for Academic Program Collaboration in a Multi-Centre City

Purpose: To build a world-class medical physics educational program that capitalizes on expertise distributed over several clinical, government, and academic centres. Few if any of these centres would have the critical mass to solely resource a program. Methods: In order to enable an academic program, stakeholders from five institutions made a proposal to Carleton University for a) a research network with defined membership requirements and a process for accepting new members, and b) a graduate specialization (MSc and PhD) in medical physics. Both proposals were accepted and the program has grown steadily. Our courses are taught by medical physicists from across the collaboration. Our students have access to physicists in: clinical radiotherapy (the Ottawa Cancer Centre treats 4500 new patients/y), radiology, cardiology and nuclear medicine, Canada’s primary standards dosimetry laboratory, radiobiology, and university-based medical physics research. Our graduate courses emphasize the foundational physics plus applied aspects of imaging, radiotherapy, and radiobiology. Active researchers in the city-wide volunteer-run network are appointed as adjunct professors by Physics, giving them access to national funding competitions and partial student funding through teaching assistantships while opening up facilities in their institutions for student thesis research. Results: The medical physics network has grown to ∼40 members from eight institutions and includes five full-time faculty in Physics and 17 adjunct research professors. The graduate student population is ∼20. Our graduates have proceeded to a spectrum of careers. Our alumni list includes a CCPM Past-President, the current COMP President, many clinical physicists, and the heads of at least three major clinical medical physics departments. Our PhD was Ontario’s first CAMPEP-accredited program. Conclusion: A self-governing volunteer network is the foundational element that enables an MSc/PhD medical physics program in a city with multiple physicist employers. It enriches graduate education with an unusually broad range of expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

A Study of the Residual Gas Composition in the Vacuum System of the Cyclotron of the Ioffe Physical Technical Institute

Mass spectra of residual gas molecules in vacuum system of the cyclotron of the Ioffe Physical Technical Institute (St. Petersburg) were obtained under various experimental conditions using a compact FT-200 time-of-flight mass spectrometer designed and manufactured at the institute. The measurements were performed in the vacuum chamber of cyclotron and in a terminal part of the ion guiding channel near the sample irradiation chamber. It is established that main contributions to residual gas composition in the cyclotron vacuum chamber are related to molecules of the vacuum oil (up to 82 vol %) and water molecules (up to 15–17 vol %), Water molecules also account for the main contribution (up to 63 vol %) to residual gas composition in the terminal part of the ion guiding channel near the sample irradiation chamber with a polymer film. The obtained data provide a basis for upgrade of the cyclotron complex of the Ioffe Physical Technical Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IACMI–The Composites Institute Efforts in Current and Post–COVID-19 Manufacturing Era—Innovations and Sustainability

Institute for Advanced Composites Manufacturing Innovation (IACMI)–The Composites Institute comprises 150 industry members making up the supply chain from material suppliers; Tiers 1, 2, and 3 original equipment manufacturer (OEM)s and fabricators; academia; and national laboratories. In this work, the institute is addressing the needs for medical systems support in response to the coronavirus 2019 (COVID-19) crisis and the recovery of the U.S. composites industry and connected manufacturing supply chains. The impact of the current and post-COVID response by IACMI and its partners extends across health care, automotive, transportation, construction, infrastructure, aerospace, sports, marine, and industrial sectors. Sustainability and circular economy of advanced materials and manufacturing play a key role in overall reduced embodied energy. This technical note provides a summary of IACMI efforts in response to COVID-19 and outlook for the post-COVID era with a focus on sustainable advanced materials and manufacturing.

36 MATERIALS SCIENCE↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗