Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inertia”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Neural network emulation of spontaneous fission

Large-scale computations of fission properties are an important ingredient for nuclear reaction network calculations simulating rapid neutron-capture process (the 𝑟 process) nucleosynthesis. Due to the large number of fissioning nuclei potentially contributing to the 𝑟 process, a microscopic description of fission based on nuclear density functional theory (DFT) is computationally challenging. Here, we explore the use of neural networks (NNs) to construct DFT emulators capable of predicting potential energy surfaces and collective inertia tensors across the whole nuclear chart, starting from a minimal set of DFT calculations. We use constrained Hartree-Fock-Bogoliubov (HFB) calculations to predict the potential energy and collective inertia tensor in the axial quadrupole and octupole collective coordinates, for a set of nuclei in the 𝑟-process region. We then employ NNs to emulate the HFB energy and collective inertia tensor across the considered region of the nuclear chart. Least-action pathways characterizing spontaneous fission half-lives and fragment yields are then obtained by means of the nudged elastic band method. The potential energy predicted by NNs agrees with the DFT value to within a root-mean-square error of 500 keV, and the collective inertia components agree to within an order of magnitude. These results are largely independent of the NN architecture. The exit points on the outer turning line are found to be well emulated. For the spontaneous fission half-lives the NN emulation provides values that are found to agree with the DFT predictions within a factor of 10 3 across more than 70 orders of magnitude. Neural networks are able to emulate the potential energy and collective inertia well enough to reasonably predict physical observables. Future directions of study, such as the inclusion of additional collective degrees of freedom and active learning, will improve the predictive power of microscopic theory and further enable large-scale fission studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Thermodynamic analysis of heat transfer reduction in spark ignition using thermal barrier coatings

This work uses a 0D thermodynamic engine model coupled to a 1D surface temperature solver to study the potential of low thermal inertia thermal barrier coatings (TBCs) on combustion chamber surfaces to increase the efficiency of spark ignition engines. Under ideal conditions, coating the piston crown, head, and valve faces with a TBC with a thermal inertia of 640 J/m 2 K s 1/2 resulted in less than a 1% relative improvement in efficiency. Despite using a low thermal inertia coating to avoid open cycle charge heating, the reduction in closed cycle heat transfer, which is the pathway to increasing efficiency, increased knock propensity. Therefore, any efficiency gain through closed cycle heat transfer reduction in spark ignition is offset by the need to retard spark timing to counter knock. An exergy analysis of completely blocking heat transfer for a 10 crank-angle degree window showed that on a low compression engine, like those used for stoichiometric gasoline spark ignition, the maximum efficiency gain achievable was limited compared to a higher compression ratio engine. Furthermore, the high gas temperatures of stoichiometric operation mean that even state-of-the-art TBCs cannot elevate surface temperatures enough purely through temperature swing to achieve a significant reduction in heat transfer near top dead center, where work availability is highest. Overall, these results indicate that low thermal inertia TBCs are ill-suited for achieving an efficiency benefit in spark ignition through a heat transfer reduction pathway. Instead spark ignition TBC research should explore ways to use low thermal inertia TBCs to achieve open cycle charge cooling to reduce knock propensity.

Engineering↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

Reciprocal swimming at intermediate Reynolds number

In Stokes flow, Purcell's scallop theorem forbids objects with time-reversible (reciprocal) swimming strokes from moving. In the presence of inertia, this restriction is eased and reciprocally deforming bodies can swim. A number of recent works have investigated dimer models that swim reciprocally at intermediate Reynolds numbers Re≈1–1000. These show interesting results (e.g. switches of the swim direction as a function of inertia) but the results vary and seem to be case specific. Here, in this work, we introduce a general model and investigate the behaviour of an asymmetric spherical dimer of oscillating length for small-amplitude motion at intermediate Re. In our analysis we make the important distinction between particle and fluid inertia, both of which need to be considered separately. We asymptotically expand the Navier–Stokes equations in the small-amplitude limit to obtain a system of linear partial differential equations. Using a combination of numerical (finite element) and analytical (reciprocal theorem, method of reflections) methods we solve the system to obtain the dimer's swim speed and show that there are two mechanisms that give rise to motion: boundary conditions (an effective slip velocity) and Reynolds stresses. Each mechanism is driven by two classes of sphere–sphere interactions, between one sphere's motion and (1) the oscillating background flow induced by the other's motion, and (2) a geometric asymmetry induced by the other's presence. We can thus unify and explain behaviours observed in other works. Our results show how sensitive, counterintuitive and rich motility is in the parameter space of finite inertia of particles and fluid.

42 ENGINEERING↗

Magnetic nulls in interacting dipolar fields

The prominence of nulls in reconnection theory is due to the expected singular current density and the indeterminacy of field lines at a magnetic null. Electron inertia changes the implications of both features. Magnetic field lines are distinguishable only when their distance of closest approach exceeds a distance Δ d . Electron inertia ensures Δ d ≳ c/ω pe . The lines that lie within a magnetic flux tube of radius Δ d at the place where the field strength B is strongest are fundamentally indistinguishable. If the tube, somewhere along its length, encloses a point where B = 0 vanishes, then distinguishable lines come no closer to the null than ≈ (a 2 c/ω pe ) 1/3 , where a is a characteristic spatial scale of the magnetic field. Here, the behaviour of the magnetic field lines in the presence of nulls is studied for a dipole embedded in a spatially constant magnetic field. In addition to the implications of distinguishability, a constraint on the current density at a null is obtained, and the time required for thin current sheets to arise is derived.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗