Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Incident response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Central-Monitor Software Module

One of the software modules of the emergency-vehicle traffic-light-preemption system of the two preceding articles performs numerous functions for the central monitoring subsystem. This module monitors the states of all units (vehicle transponders and intersection controllers): It provides real-time access to the phases of traffic and pedestrian lights, and maps the positions and states of all emergency vehicles. Most of this module is used for installation and configuration of units as they are added to the system. The module logs all activity in the system, thereby providing information that can be analyzed to minimize response times and optimize response strategies. The module can be used from any location within communication range of the system; with proper configuration, it can also be used via the Internet. It can be integrated into call-response centers, where it can be used for alerting emergency vehicles and managing their responses to specific incidents. A variety of utility subprograms provide access to any or all units for purposes of monitoring, testing, and modification. Included are "sniffer" utility subprograms that monitor incoming and outgoing data for accuracy and timeliness, and that quickly and autonomously shut off malfunctioning vehicle or intersection units.

Bachelder, Aaron↗

Fabrication and Test of an Optical Magnetic Mirror

Traditional mirrors at optical wavelengths use thin metalized or dielectric layers of uniform thickness to approximate a perfect electric field boundary condition. The electron gas in such a mirror configuration oscillates in response to the incident photons and subsequently re-emits fields where the propagation and electric field vectors have been inverted and the phase of the incident magnetic field is preserved. We proposed fabrication of sub-wavelength-scale conductive structures that could be used to interact with light at a nano-scale and enable synthesis of the desired perfect magnetic-field boundary condition. In a magnetic mirror, the interaction of light with the nanowires, dielectric layer and ground plate, inverts the magnetic field vector resulting in a zero degree phase shift upon reflection. Geometries such as split ring resonators and sinusoidal conductive strips were shown to demonstrate magnetic mirror behavior in the microwave and then in the visible. Work to design, fabricate and test a magnetic mirror began in 2007 at the NASA Goddard Space Flight Center (GSFC) under an Internal Research and Development (IRAD) award Our initial nanowire geometry was sinusoidal but orthogonally asymmetric in spatial frequency, which allowed clear indications of its behavior by polarization. We report on the fabrication steps and testing of magnetic mirrors using a phase shifting interferometer and the first far-field imaging of an optical magnetic mirror.

Hagopian, John G.↗

Ongoing Work: A Prototype Dataset for Low-flying Autonomous Medical UAS Operations

This paper presents ongoing work to create a dataset for low-flying autonomous medical UAS operations, focused on human stance recognition. This is an exploration of the viability of airborne classification for the Drone as a First Responder (DFR) concept in which a UAS arrives at the scene of an incident before emergency response personnel can get there and provides some level of situational awareness for the personnel arriving to the scene. Future incarnations could also see the UAS administer some level of care to injured parties at the scene. The data set, focused on detecting human stance, being developed here is the result of 30 test flights at NASA Langley Research Center in early 2024. In addition to flights where the participant (an anthropomorphic testing device or human) is alone in the viewing area holding a particular stance, two emergency scenes have been fabricated and collected through video - ``bike crash'' and ``difficult camping''. These test flights include four human participants. The contribution of this work upon completion will be a publicly available data set for the development of classification engines focused on human stance, and in the future, even triage.

Uncrewed Aerial Systems↗

Motion of the heliospheric termination shock 3: Incident interplanetary shocks

In this paper the response of the heliospheric termination shock to an incident interplanetary shock is examined. This paper is an extension of a recent study by Barnes (1993), which treated the analogous problem for an incident contact discontinuity. The termination shock is treated as a strong gas-dynamic shock. The post-interaction configuration consists of a moving termination shock, a postshock contact discontinuity, and either a shock or rarefaction wave propagating the disturbance signal into the downstream medium. For a decrease in dynamic pressure a rarefaction wave propagates downstream, and the new termination shock propagates inward, while, for an enhancement of dynamic pressure, the termination shock moves outwards and a weak outer shock propagates into the downstream medium; speeds of motion of the termination shock are typically of the order of approximately 100 km/s. The results are similar to those presented by Barnes (1993) indicating that the results of that paper are robust within the gas-dynamic model, in the sense of being independent of the details of the initial disturbance.

Naidu, Kamcilla↗

FRMAC Assessment Manual Volume 1 - Assessment Division Operations

In the event of a major radiological incident or accident, the Federal Radiological Monitoring and Assessment Center (FRMAC) will coordinate the federal agencies that have various statutory responsibilities and/or capabilities for responding to such incidents (Ref. FRMAC10). The FRMAC is responsible for coordinating all environmental radiological monitoring, sampling, and assessment activities for the response. For less severe radiological incidents, elements of the Department of Energy (DOE) Consequence Management (CM) program, such as the CM Response Team (CMRT) or CM Home Team (CMHT) may be activated to provide similar support activities to regional or local response assets. This manual describes the roles and responsibilities of the Assessment Division of the FRMAC during a response to a radiological incident. Every effort will be made in this manual in accordance with the Implementation of the National Incident Management System (NIMS)/Incident Command System (ICS) in the Federal Radiological Monitoring and Assessment Center (FRMAC) – Emergency Phase (Ref. RSL07) to use terminology consistent with the National Incident Management System (NIMS) for Incident Command System (ICS) organizations, planning processes, and leadership positions (Ref. FEMA17). This manual also applies to smaller scale CM responses that may involve the CMRT or CMHT elements without the formation of a FRMAC. It details the concept of operations for the Assessment Division, including common tasks performed by the Division. This manual also describes the organizational structure of the Assessment Division and roles of the personnel within the Division.

61 RADIATION PROTECTION AND DOSIMETRY↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30°. The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary science results from the Shuttle Imaging Radar-B

Preliminary results of analyzing digital radar imagery data obtained by the SIR-B aboard the Space Shuttle Challenger STS 41-G are presented. The data cover 5 million square kilometers of the earth surface between 57 deg north and south latitudes. Radar imagery of the same target at different incidence angles was used to classify surfaces by their backscatter response as a function of incidence angle. The SIR-B proved to be useful for collecting multiple incidence angle data sets over a broad range of targets, providing information in the areas of geology, archeology, forestry, agriculture, oceanography, geography, and hydrology. The analysis is also used to optimize radar parameters such as look angle for future missions.

Ruzek, M.↗

A Case Study in Assessing a Potential Severity Framework for Incidents from a Decadal Sample

In this study, the primary objective of this case study is to determine the applicability and feasibility of a framework that leverages occupational incident details to prospectively identify “potential Serious Injury or Fatality” (pSIF) cases. This study comprehensively reviewed a random sample of 1,081 injury and illness cases across 21 generalized incident types spanning over a decade at Lawrence Livermore National Laboratory (LLNL), a U.S. Department of Energy research and development facility with more than 9,000 employees. The review applied a general framework that classified each case on information suitability, potential severity, and future incident mitigation. The findings from the study indicate that 86.6% of the cases had sufficient information to make a high-confidence determination on potential severity, underscoring the feasibility of applying this general framework. Additionally, cases with a higher pSIF score had, on average, a higher level of institutional response. Implementing a simplified methodology for incident classification that emphasizes incidents that pose high potential severity, regardless of incident type, can help LLNL prioritize resources and tailor responses to such incidents using a graded approach. LLNL has recognized the value of this capability and is integrating the framework into their injury and illness process in the 2024 calendar year.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Phytochrome-mediated responses: Implications for controlled environment research facilities

Light is undoubtedly the most important environmental variable for plant growth and development; plants not only use radiant energy in photosynthesis, they also respond to the quantity, quality, direction and timing of incident radiation through photomorphogenic response that can have huge effects on the rate of growth and the pattern of development. It is surprising, therefore, that the manufacturers and suppliers of controlled environment facilities have been singularly uninventive in the design of the lighting assemblies they provide. The consumer has one choice only - a lighting assembly that provides irradiance levels usually only a fraction of sunlight, and a control system that is limited to regulating the timing of the on-off switch. The reasons for these limitations are partly technological, but in the main they result from ignorance on the part of both the consumer and the manufacturer. A specific and powerful example of this ignorance relates to the importance of the so-called far-red wavelengths (FR = 700-800 nm). Because the human eye can hardly detect wavelengths above 700 nm, and photosynthesis also cuts off at about 700 nm, the majority of plant and crop physiologists are still almost completely unaware that FR radiation can have massive effects on growth rate and development. In consequence, most growth cabinets have light sources based on fluorescent tubes, and provide very little FR apart from that emitted by a token number of small incandescent bulbs. Larger growth facilities often use broader spectrum light sources, but growth facilities that provide the capability to vary the FR incident upon the plants are about as abundant as seals in the Sahara. This article sets the background of the significance of FR radiation in the natural environment and its importance for plant growth and development in the hope that it might inform intelligently those concerned with improving the design of plant growth facilities.

Smith, Harry↗

The scattering of electromagnetic pulses by a slit in a conducting screen

A direct method for calculating the impulse response of a slit in a conducting screen is presented which is derived specifically for the analysis of transient scattering by two-dimensional objects illuminated by a plane incident wave. The impulse response is obtained by assuming that the total response is composed of two sequences of diffracted waves. The solution is determined for the first two waves in one sequence by using Green's functions and the equivalence principle, for additional waves in the sequence by iteration, and for the other sequence by a transformation of coordinates. The cases of E-polarization and H-polarization are considered.

Ackerknecht, W. E., III↗

Experimental study of electromagnetic wave scattering from a gyrotropic gaseous plasma column

We experimentally demonstrate the controlled scattering of incident transverse-electric electromagnetic waves from a gyrotropic magnetized plasma cylindrical discharge. Scattered electromagnetic waves can bend left and right by changing the external magnetic field of a plasma rod. Measured scattered wavefronts are in good agreement with electromagnetic simulations. A gyrotropic response is observed for incident wave frequencies ranging from 3.5 to 5.6 GHz for conditions corresponding to a ratio of cyclotron frequency to plasma frequency, ω ce /ω p ≈ 0.16. In conclusion, the observation of a gyrotropic response from cylindrical plasma discharges paves the way for their use as building blocks for future devices such as magnetized plasma photonic crystals, topological insulators, plasma metamaterials, non-reciprocal waveguide structures, and other devices, which require a tunable gyrotropic response from centimeter to meter-scale materials with application-specific geometry.

42 ENGINEERING↗

Correlation between microwave scattering and emission from land and sea at 13.9 GHz

Correlations have been calculated between active and passive microwave responses received by the S-193 radiometer-scatterometer on Skylab. Over both land and sea, the correlations between polarizations are high, but the correlation between radiometer and scatterometer response at 30-deg incidence is negligible. This suggests that multipolarization instruments with this crude resolution (greater than 10 km in all cases) are redundant, but a combination of radiometer and scatterometer is useful. Correlations among the responses at different angles suggest that the five angles used in Skylab are more than would be useful between zero and 48 deg in future instruments, but that instruments with three angles of measurement would be useful. In small areas, conclusions based on these large-data-set averages may need to be modified.

Sobti, A.↗

A common fluence threshold for first positive and second positive phototropism in Arabidopsis thaliana

The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 x 10(-5) to 6.5 x 10(-3) micromoles per square meter per second. The threshold values in the fluence rate-response curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system.

NASA Discipline Number 29-20↗

Safety of Mobile Hydrogen and Fuel Cell Technology Applications: An Investigation by the Hydrogen Safety Panel

Safe practices in the production, storage, distribution, and use of hydrogen are essential for the widespread acceptance of hydrogen and fuel cell technologies. A significant safety incident could damage public perception of hydrogen and fuel cells. Recent incidents involving multi-cylinder hydrogen transport vehicles in the United States have brought attention to the potential impacts of mobile hydrogen storage and transportation. Road transportation of bulk gaseous hydrogen presents unique hazards that can be very different from those for stationary equipment, and new equipment developers may have less experience and expertise than seasoned gas providers. In response to the aforementioned incidents, and in support of hydrogen and fuel cell activities in California specifically, the Hydrogen Safety Panel (HSP) has investigated the safety of mobile hydrogen and fuel cell applications (mobile auxiliary/emergency fuel cell power units, mobile fuelers, multi-cylinder transport vehicles, unmanned aircraft power supplies, and mobile hydrogen generators). The HSP examined the applications, requirements, and performance of mobile applications that are being used extensively outside of California to understand how safety considerations are applied. This report discusses the results of the HSP’s evaluation of hydrogen and fuel cell mobile applications along with recommendations to address relevant safety issues.

08 HYDROGEN↗

The Effect of Prostate-Specific Antigen (PSA) Test on Radiation Risk Estimate for Prostate Cancer Incidence among Atomic-Bomb Survivors

Following our previous report on the radiation doseresponse for prostate cancer incidence rates in the Life Span Study (LSS) cohort of atomic bomb survivors, we reevaluated the radiation-related risk adjusting for differences in baseline cancer incidence rates among three subsets of the LSS cohort defined by the timing of their first participation in biennial health examinations offered to the Adult Health Study (AHS) sub-cohort members and prostate-specificantigen (PSA) testing status for AHS participants: 1. nonAHS participants, 2. AHS participants before receiving PSA test, and 3. AHS participants after receiving PSA test. We found a 2.9-fold increase in the baseline incidence rates among AHS participants after receiving PSA test. After adjusting for the PSA-testing-status effects on the baseline rates the estimated excess relative risk (ERR) per Gy was 0.54 (95% CI: 0.15, 1.05), which was almost identical to the previously reported unadjusted ERR estimate (0.57, 95% CI: 0.21, 1.00). The current results confirmed that, while the PSA testing among AHS participants increased the baseline incidence rates, it did not impact the radiation risk estimate, strengthening the previously reported dose-response relationship for prostate cancer incidence in the LSS. As the use of PSA tests continue in screening and medical settings, analyses of possible effects of PSA testing should be an important aspect of future epidemiological studies of the association between radiation exposure and prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of proton-induced energy deposition in integrated circuits

A time-efficient simulation technique was developed for modeling the energy deposition by incident protons in modern integrated circuits. To avoid the excessive computer time required by many proton-effects simulators, a stochastic method was chosen to model the various physical effects responsible for energy deposition by incident protons. Using probability density functions to describe the nuclear reactions responsible for most proton-induced memory upsets, the simulator determines the probability of a proton hit depositing the energy necessary for circuit destabilization. This factor is combined with various circuit parameters to determine the expected error-rate in a given proton environment. An analysis of transient or dose-rate effects is also performed. A comparison to experimental energy-disposition data proves the simulator to be quite accurate for predicting the expected number of events in certain integrated circuits.

Fernald, Kenneth W.↗

Determining Concentration of Nanoparticles from Ellipsometry

A method of using ellipsometry or polarization analysis of light in total internal reflection of a surface to determine the number density of gold nanoparticles on a smooth substrate has been developed. The method can be modified to enable determination of densities of sparse distributions of nanoparticles in general, and is expected to be especially useful for measuring gold-nanoparticle-labeled biomolecules on microarrays. The method is based on theoretical calculations of the ellipsometric responses of gold nanoparticles. Elements of the calculations include the following: For simplicity, the gold nanoparticles are assumed to be spherical and to have the same radius. The distribution of gold nanoparticles is assumed to be a sub-monolayer (that is, sparser than a monolayer). The optical response of the sub-monolayer is modeled by use of a thin-island-film theory, according to which the polarizabilities parallel and perpendicular to the substrate are functions of the wavelength of light, the dielectric functions (permittivities expressed as complex functions of frequency or wavelength) of the gold and the suspending medium (in this case, the suspending medium is air), the fraction of the substrate area covered by the nanoparticles, and the radius of the nanoparticles. For the purpose of the thin-island-film theory, the dielectric function of the gold nanoparticles is modeled as the known dielectric function of bulk gold plus a correction term that is necessitated by the fact that the mean free path length for electrons in gold decreases with decreasing radius, in such a manner as to cause the imaginary part of the dielectric function to increase with decreasing radius (see figure). The correction term is a function of the nanoparticle radius, the wavelength of light, the mean free path and the Fermi speed of electrons in bulk gold, the plasma frequency of gold, and the speed of light in a vacuum. These models are used to calculate ellipsometric responses for various concentrations of gold nanoparticles having an assumed radius. The modeled data indicates distinct spectral features for both the real and the imaginary part of the dielectric function. An ellipsometric measurement would determine this distinct feature and thus can be used to measure nanoparticle concentration. By "ellipsometric responses" is meant the intensities of light measured in various polarization states as functions of the angle of incidence and the polarization states of the incident light. These calculated ellipsometric responses are used as calibration curves: Data from subsequent ellipsometric measurements on real specimens are compared with the calibration curves. The concentration of the nanoparticles on a specimen is assumed to be that of the calibration curve that most closely matches the data pertaining to that specimen.

Venkatasubbarao, Srivatsa↗

Modeling a Civil Event Case Study for Consequence Management Using the IMPRINT Forces Module

A critical challenge in the Consequence Management (CM) domain is the appropriate allocation of necessary and skilled military and civilian personnel and materiel resources in unexpected emergencies. To aid this process we used the Forces module in the Improved Performance Research Integration Tool (IMPRINT). This module enables analysts to enter personnel and equipment capabilities, prioritized schedules and numbers available, along with unexpected emergency requirements in order to assess force response requirements. Using a suspected terrorist threat on a college campus, we developed a test case model which exercised the capabilities of the module, including the scope and scale of operations. The model incorporates data from multiple sources, including daily schedules and frequency of events such as fire calls. Our preliminary results indicate that the model can predict potential decreases in civilian emergency response coverage due to an involved unplanned incident requiring significant portions of police, fire and civil responses teams.

Gacy, Marc↗