Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Survival, healing, and swim performance of juvenile migratory sea lamprey ( Petromyzon marinus ) implanted with a new acoustic microtransmitter designed for small eel-like fishes

Background: Little is known about the transformer stage of the parasitic lampreys, a brief but critical period that encompasses juvenile out-migration from rivers to lakes or oceans to begin parasitic feeding. Information about this life stage could have significant conservation implications for both imperiled and invasive lampreys. We investigated tag retention, survival, wound healing, and swim performance of newly transformed sea lamprey (Petromyzon marinus) implanted with a new micro-acoustic transmitter, the eel–lamprey acoustic transmitter (ELAT), in a controlled laboratory environment. Results: The 61-day survival of our tagged subjects was 71%, within the range reported in similar studies of juvenile lampreys. However, survival was significantly lower in the tagged animals (vs control), with no effect statistically attributable to measures of animal length, mass, condition, or population of origin (Great Lakes vs. Atlantic drainage). Mortality in tagged fish was concentrated in the first four days post-surgery, suggesting injury from the surgical process. An unusually long recovery time from anesthesia may have contributed to the increased mortality. In a simple burst swim assay, tagged animals swam significantly slower (– 22.5%) than untagged animals, but were not significantly different in endurance swim tests. A composite wound healing score at day four was a significant predictor of maximum burst swim speed at day 20, and wound condition was related to animal mass, but not length, at the time of tagging. Conclusions: Impairments to survival and swim performance of juvenile sea lamprey implanted with the ELAT transmitter were within currently reported ranges for telemetry studies with small, difficult to observe fishes. Our results could be improved with more refined anesthesia and surgical techniques. The ability to track migratory movements of imperiled and pest populations of parasitic lampreys will improve our ability to estimate vital rates that underlie recruitment to the adult population (growth, survival) and to investigate the environmental factors that regulate the timing and rates of movement, in wild populations.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Source Development for Focused Ion Beam Implantation and Irradiation [Slides]

We have demonstrated focused ion implantation for fabrication of single atom devices and nanofabrication. This is a viable solution for prototyping - fast and easy! There is on-going work in diamond, SiN, SiC, hBN, GaN, AlGan, etc. A new liquid metal alloy ion source development is on-going. There is a pathway towards deterministic defect centers in wide bandgap materials using FIB implantation.

43 PARTICLE ACCELERATORS↗

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.↗

Modulating Oxide‐Based Quantum Materials by Ion Implantation

Ion implantation has emerged as a powerful tool for manipulating and investigating oxide quantum materials, where strong electron correlations give rise to exotic phases and functionalities. This Review examines how controlled ion bombardment enables targeted modulation of structural, electronic, and magnetic properties in complex oxides. Recent advances in ion beam techniques is analyzed that provide unprecedented control over defect profiles, from point defects to extended damage cascades. In application, ion irradiation has demonstrated the ability to tune quantum phenomena including metal‐insulator transitions, magnetism, and superconductivity through selective doping, defect creation, and lattice strain. The ability to write quantum states with nanoscale precision using focused ion beams is opening new paths for quantum device fabrication. Challenges in understanding radiation damage mechanisms in strongly correlated systems is discussed, and identify opportunities for designing quantum functionality through defect‐engineering approaches. The technique's demonstrated capability to write quantum states with nanoscale precision, combined with its compatibility with existing semiconductor processing infrastructure, suggests a clear pathway for translating fundamental discoveries in quantum materials into practical technological applications.

defect engineering↗

Implanting Transition Metal into Li 2 O-Based Cathode Prelithiation Agent for High-Energy-Density and Long-Life Li-Ion Batteries

Compensating the irreversible loss of limited active lithium (Li) is essentially important for improving the energy-density and cycle-life of practical Li-ion battery full-cell, especially after employing high-capacity but low initial coulombic efficiency anode candidates. Introducing prelithiation agent can provide additional Li source for such compensation. Herein, we precisely implant trace Co (extracted from transition metal oxide) into the Li site of Li 2 O, obtaining (Li 0.66 Co 0.11$\square$0.23 ) 2 O (CLO) cathode prelithiation agent. Further, the synergistic formation of Li vacancies and Co-derived catalysis efficiently enhance the inherent conductivity and weaken the Li-O interaction of Li 2 O, which facilitates its anionic oxidation to peroxo/superoxo species and gaseous O 2 , achieving 1642.7 mAh/g ~Li2O prelithiation capacity (≈980 mAh/g for prelithiation agent). Coupled 6.5 wt % CLO-based prelithiation agent with LiCoO 2 cathode, substantial additional Li source stored within CLO is efficiently released to compensate the Li consumption on the SiO/C anode, achieving 270 Wh/kg pouch-type full-cell with 92 % capacity retention after 1000 cycles.

25 ENERGY STORAGE↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Influence of metal nanocomposite morphology on Helium implantation response

This work reports on Helium (He) accumulation in novel metal nanocomposites fabricated by phase separation in three-dimensions. These nanocomposites are dense with semi-coherent interfaces that ultimately influence He implantation response. The effect of film morphology on three aspects of He response is investigated: size and distribution of He precipitates, He retention, and He-induced changes in mechanical properties. Here, transmission electron microscopy analysis showed that He bubbles agglomerated along the vertical phase boundaries in morphologies with lateral and random domains of Cu and Mo. Nuclear Reaction Analysis (NRA) and nanoindentation results show He retention and hardness is morphology dependent.

36 MATERIALS SCIENCE↗

Self-assembly of solid nanoclusters in molybdenum under gas ion implantation

The self-assembly of defects in materials could create unique physical and chemical properties. In nuclear fuels, the formation of self-assembled fission products mitigates fission-gas-release and swelling. In this work, we report the formation of a solid nanocluster superlattice in molybdenum, an important constituent in metallic fuels, under krypton gas ion implantation. X-ray absorption near edge structure measurements coupled with density functional theory calculations show that the pressure of krypton nanoclusters in molybdenum is ~2 GPa and molecular dynamic simulations reveal that the krypton atoms are solid in the nanoclusters with a krypton-to-vacancy ratio of ~0.28 at 300 K.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise Fermi level engineering in a topological Weyl semimetal via fast ion implantation

The precise controllability of the Fermi level is a critical aspect of quantum materials. For topological Weyl semimetals, there is a pressing need to fine-tune the Fermi level to the Weyl nodes and unlock exotic electronic and optoelectronic effects associated with the divergent Berry curvature. However, in contrast to two-dimensional materials, where the Fermi level can be controlled through various techniques, the situation for bulk crystals beyond laborious chemical doping poses significant challenges. Here, we report the milli-electron-volt (meV) level ultra-fine-tuning of the Fermi level of bulk topological Weyl semimetal tantalum phosphide using accelerator-based high-energy hydrogen implantation and theory-driven planning. By calculating the desired carrier density and controlling the accelerator profiles, the Fermi level can be experimentally fine-tuned from 5 meV below, to 3.8 meV below, to 3.2 meV above the Weyl nodes. High-resolution transmission electron microscopy reveals the crystalline structure is largely maintained under irradiation, while electrical transport indicates that Weyl nodes are preserved and carrier mobility is also largely retained. Our work demonstrates the viability of this generic approach to tune the Fermi level in semimetal systems and could serve to achieve property fine-tuning for other bulk quantum materials with ultrahigh precision.

36 MATERIALS SCIENCE↗

1.2-kV Vertical GaN PIN Rectifier With Ion-Implanted Floating Guard Rings

Here, this work reports on the fabrication and properties of a homojunction gallium nitride (GaN) p-i-n (PIN) rectifier fabricated on a free-standing GaN substrate. Uniform device performance is achieved with breakdown voltage (BV) >1.2 kV and low ON-resistance × area ( R ON A ). The statistics of the BV measurements show 58.5% of devices achieve BV >1.3 kV, and 71.1% of devices achieve BV >1.2 kV, as attributed to high quality and control in both epitaxial growth and device process. At room temperature, R ON A is 0.23 mΩ∙ cm 2 at a current density ( J ) of 6.9 kA/cm2. The corresponding Baliga’s figure of merit is >5.97 GW/cm 2 . Temperature-dependent reverse I – V measurements were performed and show a positive temperature coefficient of 0.42 V/K, indicating the avalanche capability of reverse breakdown. Further analysis with the Poole-Frenkel model on the temperature-dependent measurement suggested that a trap-assisted tunneling process contributed to the reverse leakage current. Floating guard rings (FGRs) formed by nitrogen implantation serve as an effective edge termination technique in these GaN PIN rectifiers, resulting in uniform performance in both forward and reverse bias.

42 ENGINEERING↗

Do Chemical Effects Affect the Accumulation of Structural Damage during the Implantation of Fluorine Ions into GaN?

The accumulation of structural damage in GaN under irradiation with accelerated F and Ne ions with energies of 1.3 and 3.2 keV/amu is investigated. It is shown that chemical effects during implantation of fluorine ions within the doses under consideration do not noticeably affect the formation of stable structural damage both in the bulk and on the surface of GaN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of Patient-Reported Outcomes After Breast-Conserving Surgery and Mastectomy with Implant Breast Reconstruction

Background: Many factors influence decisions regarding choice of breast-conserving surgery (BCS) versus mastectomy with reconstruction for early invasive breast cancer. The purpose of this study was to compare patient satisfaction following BCS and mastectomy with implant reconstruction (M-iR) utilizing the BREAST-Q patient-reported outcome measure. Methods: Women with stage I or II breast cancer undergoing BCS or M-iR who completed a BREAST-Q from 2010 to 2016 were identified by retrospective review of a prospective database. Baseline characteristics were compared, and linear mixed models were used to analyze associations with BREAST-Q scores over time. Results: Our study group was composed of 3233 women; 2026 (63%) had BCS, 123 (3.8%) had nipple-sparing mastectomy, and 1084 (34%) had skin-sparing or total mastectomy. Median time from surgery to BREAST-Q was 205 days for BCS and 639 days for M-iR (p < 0.001). Regardless of type of surgery, breast satisfaction scores decreased significantly over time (p < 0.001), whereas psychosocial (p = 0.001) and sexual (p = 0.004) well-being scores increased significantly over time. BCS was associated with significantly higher scores over time compared with M-iR across all subscales (all p < 0.001). Radiation was significantly associated with decreased scores over time across all subscales (all p < 0.05). Conclusions: Breast satisfaction and quality-of-life scores were higher for BCS compared with M-iR in early-stage invasive breast cancer. These findings may help in counseling women who have a choice for surgical treatment. Breast satisfaction scores decreased over time in all women, highlighting the need for further evaluation with longer follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Handling and Tagging Techniques for Implanting Juvenile American Shad with a New Acoustic Microtransmitter

In this article, the use of telemetry techniques to better understand the behavior and survival of juvenile American shad (Alosa sapidissima), as they migrate through hydropower systems, has been challenging because shad are widely known to be particularly sensitive to handling. The goal of this study was to develop a tagging protocol using a new, acoustic micro transmitter that minimizes the detrimental effects of the tagging process and maximizes post-tagging survival of juvenile American shad. Limiting out-of-water handling and the use of brackish saltwater (7.5 parts per thousand) before and after tagging improved survival for shad tagged using a simple pectoral implantation method. This protocol provides a detailed, step-by-step procedure for tagging juvenile shad with acoustic transmitters. Fish tagged using this procedure and held in the laboratory for 60 days had an 81.5% survival rate, compared to 70% for their untagged counterparts. The successful tagging and handling practices developed in this study could be applied to field telemetry studies of juvenile shad and other sensitive species.

59 BASIC BIOLOGICAL SCIENCES↗

High-Performance, Long-Life, Rechargeable Li–CO 2 Batteries based on a 3D Holey Graphene Cathode Implanted with Single Iron Atoms

A highly efficient cathode catalyst for rechargeable Li-CO 2 batteries is successfully synthesized by implanting single iron atoms into 3D porous carbon architectures, consisting of interconnected N,S-codoped holey graphene (HG) sheets. The unique porous 3D hierarchical architecture of the catalyst with a large surface area and sufficient space within the interconnected HG framework can not only facilitate electron transport and CO 2 /Li+ diffusion, but also allow for a high uptake of Li 2 CO 3 to ensure a high capacity. Consequently, the resultant rechargeable Li-CO 2 batteries exhibit a low potential gap of approximate to 1.17 V at 100 mA g -1 and can be repeatedly charged and discharged for over 200 cycles with a cut-off capacity of 1000 mAh g -1 at a high current density of 1 A g -1 . Density functional theory calculations are performed and the observed appealing catalytic performance is correlated with the hierarchical structure of the carbon catalyst. This work provides an effective approach to the development of highly efficient cathode catalysts for metal-CO 2 batteries and beyond.

(2) batteries↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Risk Factors of Infection and Role of Antibiotic Prophylaxis in Totally Implantable Venous Access Port Placement: Propensity Score Matching

Background: To evaluate risk factors of infection and effectiveness of preprocedural single-dose intravenous prophylactic antibiotic (PABX) during totally implantable venous access port (TIVAP) placement in preventing procedure-related infections. Methods: This was a retrospective single-institution multicenter study evaluating short-term (30-day) infection outcomes after TIVAP placement. Correlation between infection rates and clinical factors, including hematologic versus non-hematologic malignancy, inpatient versus outpatient status, single versus double lumen and PABX, was investigated using univariate and multivariable analysis in the overall study population as well as the propensity-score-matched cohort. Results: Overall, 5967 patients underwent TIVAP placement from 2005 to 2016, of which 3978 (67%) patients received PABX. On propensity score matching, 1952 patients with PABX were matched to the same number of patients without PABX. TIVAP was removed due to infection concern in 48 patients in unmatched and 30 patients in matched population. There was no difference in the rate of infection between those who received PABX and those who did not in both unmatched and matched population (p = 0.5387 and 0.9999). Although infection rate was significantly higher in patients who had TIVAP placement in inpatient setting (p < 0.0001), who received a double-lumen TIVAP (p < 0.0001), or who had hematologic malignancy (p = 0.0004) on univariate analysis, inpatient status was the sole factor associated with higher rate of TIVAP infection on multivariable analysis of both overall (odds ratio 2.31, p < 0.0001) and matched populations (odds ratio 4.36, p = 0.0004). Conclusion: Placement of TIVAP in inpatient setting increases the risk of TIVAP infection. PABX before TIVAP placement does not prevent short-term procedure-related infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal diffusivity recovery and defect annealing kinetics of self-ion implanted tungsten probed by insitu transient grating spectroscopy

Tungsten is a promising candidate material for plasma-facing armour components in future fusion reactors. A key concern is irradiation-induced degradation of its normally excellent thermal transport properties. In this comprehensive study, thermal diffusivity degradation in ion-implanted tungsten and its evolution from room temperature (RT) to 1073 K is considered. Five samples were exposed to 20 MeV self-ions at RT to achieve damage levels ranging from 3.2 x 10 -4 to 3.2 displacements per atom (dpa). Transient grating spectroscopy with in-situ heating was then used to study thermal diffusivity evolution as a function of temperature. Using a kinetic theory model, an equivalent point defect density is estimated from the measured thermal diffusivity. The results showed a prominent recovery of thermal diffusivity between 450 K and 650 K, which coincides with the onset of mono-vacancy mobility. After 1073 K annealing samples with initial damage of 3.2 x 10 -3 dpa or less recover close to the pristine value of thermal diffusivity. For doses of 3.2 x 10 -2 dpa or higher, on the other hand, a residual reduction in thermal diffusivity remains even after 1073 K annealing. Transmission electron microscopy reveals that this is associated with extended, irradiation-induced dislocation structures that are retained after annealing. A sensitivity analysis shows that thermal diffusivity provides an efficient tool for the assessing total defect content in tungsten up to 1000 K.

36 MATERIALS SCIENCE↗