Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Immersive Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

111 records · Page 7

A novel approach to mitigating the potential release of radioisotopes under fire conditions - enhancing fire resiliency of radiological contamination fixatives during deactivation & decommissioning activities

Savannah River National Laboratory (SRNL), in close collaboration with the Florida International University Applied Research Center (FIU ARC), successfully executed a technology development activity on behalf of the Department of Energy, Office of Environmental Management (DOE EM). The purpose of the activity was to improve the capability of fixative technologies in immobilizing residual contamination when exposed to thermal stressors as postulated in accident scenarios in Basis for Interim Operations (BIO) documents across the DOE EM complex. The effort resulted in the test and evaluation of a down-selected, commercial-off-the-shelf (COTS) intumescent technology in a radioactive environment at the Savannah River Site (SRS) Building 235-F Plutonium Fuel Form (PuFF) Facility and highlighted the potential use of this technology as a stand-alone, fire retardant fixative. Furthermore, this activity highlighted significant shortfalls in common fixatives currently used to support decommissioning activities and brought to the forefront the need for a methodical, uniformed approach to certifying fixative technologies for operational use in Deactivation and Decommissioning (D&D) activities. An essential component of this research was to evaluate the state of industry fixatives currently in use and set the foundation for comparison to alternative technological solutions. A baseline of five (5) commonly used fixatives and decontamination gels (hereafter collectively referred to as fixatives) was conducted, and notable shortfalls and deficiencies were revealed, particularly when exposed to thermal, water, and other environmental stressors. At temperatures as low as 300 °F - 400 °F (148.89 °C – 204.44 °C), all commonly used fixatives melted from the substrates within 3-5 minutes of exposure, resulting in contaminant transport. Significant degradation in terms of mass loss, desiccation, and off-gassing occurred, and the chemical breakdown of the polymer was so complete researchers assessed there would likely have been a release of residual contamination. Additional vulnerabilities became evident when exposed to water immersion and high humidity; existing fixatives took up water, swelling and frequently delaminating from the substrate, once again increasing the likelihood of a contaminant release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Root image collection from a genotype by environment (GxE) root architecture study of the bioenergy species, Populus trichocarpa

Here we present a curated dataset; raw images of fresh roots collected from a genotype by environment (growth matrix) greenhouse root architecture study of the bioenergy species, Populus trichocarpa. Five separate experiments were performed to generate the dataset. Biological replicates (ramets, vegetative propagants) of Populus trichocarpa genotypes BESC 24 and BESC 375 were used for all experiments. The first two experiments were an eight-week and a six-week pot experiment where plants with grown in 4" X 14" sized pots were filled with Farfard 3B potting soil (Fafard Sungro #3B), and watered twice daily. Average greenhouse humidity and growth temperature were around 50-60% and 23°C, respectively. Ramets of P. trichocarpa genotypes BESC 24 and BESC 375 were used in various experiments. The source of this material was dormant field cuttings grown in greenhouse. The second experiment was a Microcosm root architecture experiment. This was done in a microcosm built with double-decker tissue culture Magenta box. Tissue culture plants with new root initials were transferred to microcosm with pro choice rapid dry growth matrix with 1x Hoagland’s solution pH5.7 and grown for six weeks until harvest. Temperature was held at ~22°C. The closed container trapped moisture. The source material was tissue culture stock plants established from shoot tips of greenhouse stock plants (obtained from same set of dormant field cuttings as rest of the study). For the remaining two experiments, greenwood stem cuttings from greenhouse grown plants were grown in six-week rhizotron and two-week hydroponics experiments in the greenhouse. For rhizotron experiments, plants were grown in 2-D rhizotron with black panels on both sides (31cm H x 30cm L x 1.2cm W) and watered daily. For hydroponics experiment, plants were grown in a 15ml falcon tube with distilled water and covered in foil and shaken a few times a day. Greenhouse temperature was held at ~ 23°C and humidity was between 50-60%. Stems were cut off and the root system was separated, gently washed to rid of matrix, immersed in a water tray and scanned for obtaining raw root images reported here. All scans of roots floating in a water tray were performed using an Epson Perfection V850 Pro Photo Scanner. Additional meta data is embedded in the raw image files.

59 BASIC BIOLOGICAL SCIENCES↗