Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Atomic-resolution imaging as a mechanistic tool for studying single-site heterogeneous catalysis

Heterogeneous catalysts dominate the chemical industry but typically feature diverse, incompletely defined active sites. Thus, describing structure-activity relationships, unlike homogeneous catalysts, remains challenging. In contrast, molecularly defined single-site heterogeneous catalysts (SSHCs), using appropriate tools, are poised to address these challenges and provide new avenues for catalysis research and development. The present study explores eco-friendly H 2 production mediated by discrete MoO 2 sites supported on carbon nanohorns (CNHs) and active for alcohol dehydrogenation. While informative, detailed ensemble EXAFS/XANES/XPS, kinetic measurements, and DFT analysis alone cannot provide a full molecular picture of the reaction pathway. Here, using single-molecule atomic-resolution time-resolved electron microscopy (SMART-EM), we propose the identification of four key catalytic intermediates anchored to CNHs and uncover a new reaction pathway involving alkoxide/hemiacetal equilibration and acetal oligomerization. Furthermore, these intermediates are inferred through a combination of theory and SMART-EM, showcasing the potential of SMART-EM as a complementary tool for exploring mechanistic hypotheses in catalysis.

36 MATERIALS SCIENCE↗

WE-AB-202-08: Feasibility of Single-Inhalation/Single-Energy Xenon CT for High-Resolution Imaging of Regional Lung Ventilation in Humans

Purpose: To demonstrate the efficacy of a novel functional lung imaging method that utilizes single-inhalation, single-energy xenon CT (Xe-CT) lung ventilation scans, and to compare it against the current clinical standard, ventilation single-photon emission CT (V-SPECT). Methods: In an IRB-approved clinical study, 14 patients undergoing thoracic radiotherapy received two successive single inhalation, single energy (80keV) CT images of the entire lung using 100% oxygen and a 70%/30% xenon-oxygen mixture. A subset of ten patients also received concurrent SPECT ventilation scans. Anatomic reproducibility between the two scans was achieved using a custom video biofeedback apparatus. The CT images were registered to each other by deformable registration, and a calculated difference image served as surrogate xenon ventilation map. Both lungs were partitioned into twelve sectors, and a sector-wise correlation was performed between the xenon and V-SPECT scans. A linear regression model was developed with forced expiratory volume (FEV) as a predictor and the coefficient of variation (CoV) as the outcome. Results: The ventilation comparison for five of the patients had either moderate to strong Pearson correlation coefficients (0.47 to 0.69, p<0.05). Of these, four also had moderate to strong Spearman correlation coefficients (0.46 to 0.80, p<0.03). The patients with the strongest correlation had clear regional ventilation deficits. The patient comparisons with the weakest correlations had more homogeneous ventilation distributions, and those patients also had diminished lung function as assessed by spirometry. Analysis of the relationship between CoV and FEV yielded a non-significant trend toward negative correlation (Pearson coefficient −0.60, p<0.15). Conclusion: Significant correlations were found between the Xe-CT and V-SPECT ventilation imagery. The results from this small cohort of patients indicate that single inhalation, single energy Xe-CT has the potential to quantify regional lung ventilation volumetrically with high resolution using widely accessible radiologic equipment. Bill Loo and Peter Maxim are founders of TibaRay, Inc. Bill Loo is also a board member. Bill Loo and Peter Maxim have received research grants from Varian Medical Systems, Inc. and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak

Two imaging x-ray crystal spectrometers, the so-called 'poloidal' and 'tangential' spectrometers, were recently implemented on experimental advanced superconducting tokamak (EAST) to provide spatially and temporally resolved impurity ion temperature (T{sub i}), electron temperature (T{sub e}) and rotation velocity profiles. They are derived from Doppler width of W line for Ti, the intensity ratio of Li-like satellites to W line for Te, and Doppler shift of W line for rotation. Each spectrometer originally consisted of a spherically curved crystal and a two-dimensional multi-wire proportional counter (MWPC) detector. Both spectrometers have now been upgraded. The layout of the tangential spectrometer was modified, since it had to be moved to a different port, and the spectrometer was equipped with two high count rate Pilatus detectors (Model 100 K) to overcome the count rate limitation of the MWPC and to improve its time resolution. The poloidal spectrometer was equipped with two spherically bent crystals to record the spectra of He-like and H-like argon simultaneously and side by side on the original MWPC. These upgrades are described, and new results from the latest EAST experimental campaign are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Following Ostwald ripening in nanoalloys by high-resolution imaging with single-atom chemical sensitivity

Several studies have shown that substantial compositional changes can occur during the coarsening of bimetallic nanoparticles (CoPt, AuPd). To explain this phenomenon that could dramatically impacts all the technologically relevant properties of nanoalloys, we have exploited the sensitivity of the latest generation of electron microscope to prove that during the beam-induced coarsening of CoPt nanoparticles, the dynamic of atom exchanges between the particles is different for Co and Pt. By distinguishing the chemical nature of individual atoms of Co and Pt, while they are diffusing on a carbon film, we have clearly shown that Co atoms have a higher mobility than Pt atoms because of their higher evaporation rate from the particles. These atomic-scale observations bring the experimental evidence on the origin of the compositional changes in nanoalloys induced by Ostwald ripening mechanisms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measuring Curved Crystal Performance for a High Resolution, Imaging X-ray Spectrometer

This paper describes the design, crystal selection, and crystal testing for a vertical Johann spectrometer operating in the 13 keV range to measure ion Doppler broadening in inertial confinement plasmas. The spectrometer is designed to use thin, curved, mica crystals to achieve a resolving power of E/ΔE>2000. A number of natural mica crystals were screened for flatness and X-ray diffraction width to find samples of sufficient perfection for use in the instrument. Procedures to select and mount high quality mica samples are discussed. A diode-type X-ray source coupled to a dual goniometer arrangement was used to measure the crystal reflectivity curve. A procedure was developed for evaluating the goniometer performance using a set of diffraction grade Si crystals. This goniometer system was invaluable for identifying the best original crystals for further use and developing the techniques to select satisfactory curved crystals for the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH-RESOLUTION IMAGING OF WATER MASER EMISSION IN THE ACTIVE GALAXIES NGC 6240 AND M51

We present the results of observations of 22 GHz H{sub 2}O maser emission in NGC 6240 and M51 made with the Karl G. Jansky Very Large Array. Two major H{sub 2}O maser features and several minor features are detected toward the southern nucleus of NGC 6240. These features are redshifted by about 300 km s{sup −1} from the galaxy’s systemic velocity and remain unresolved at the synthesized beam size. A combination of our two-epoch observations and published data reveals an apparent correlation between the strength of the maser and the 22 GHz radio continuum emission, implying that the maser excitation relates to the activity of an active galactic nucleus in the southern nucleus rather than star-forming activity. The star-forming galaxy M51 hosts H{sub 2}O maser emission in the center of the galaxy; however, the origin of the maser has been an open question. We report the first detection of 22 GHz nuclear radio continuum emission in M51. The continuum emission is co-located with the maser position, which indicates that the maser arises from nuclear active galactic nucleus-activity and not from star-forming activity in the galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution imaging of PHIBSS z ∼ 2 main-sequence galaxies in CO J = 1 → 0

We present Karl Jansky Very Large Array observations of the CO J=1−0 transition in a sample of four z∼2 main-sequence galaxies. These galaxies are in the blue sequence of star-forming galaxies at their redshift, and are part of the IRAM Plateau de Bure HIgh-z Blue Sequence Survey which imaged them in CO J=3−2. Two galaxies are imaged here at high signal-to-noise, allowing determinations of their disk sizes, line profiles, molecular surface densities, and excitation. Using these and published measurements, we show that the CO and optical disks have similar sizes in main-sequence galaxies, and in the galaxy where we can compare CO J=1−0 and J=3−2 sizes we find these are also very similar. Assuming a Galactic CO-to-H{sub 2} conversion, we measure surface densities of Σ{sub mol}∼1200 M{sub ⊙} pc{sup −2} in projection and estimate Σ{sub mol}∼ 500–900 M{sub ⊙} pc{sup −2} deprojected. Finally, our data yields velocity-integrated Rayleigh–Jeans brightness temperature line ratios r{sub 31} that are approximately at unity. In addition to the similar disk sizes, the very similar line profiles in J=1−0 and J=3−2 indicate that both transitions sample the same kinematics, implying that their emission is coextensive. We conclude that in these two main-sequence galaxies there is no evidence for significant excitation gradients or a large molecular reservoir that is diffuse or cold and not involved in active star formation. We suggest that r{sub 31} in very actively star-forming galaxies is likely an indicator of how well-mixed the star formation activity and the molecular reservoir are.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH SPATIAL RESOLUTION IMAGING OF THERMAL EMISSION FROM DEBRIS DISKS

We have obtained subarcsecond mid-IR images of a sample of debris disks within 100 pc. For our sample of 19 A-type debris disk candidates chosen for their IR excess, we have resolved, for the first time, five sources plus the previously resolved disk around HD 141569. Two other sources in our sample have been ruled out as debris disks since the time of sample selection. Three of the six resolved sources have inferred radii of 1-4 AU (HD 38678, HD 71155, and HD 181869), and one source has an inferred radius {approx}10-30 AU (HD 141569). Among the resolved sources with detections of excess IR emission, HD 71155 appears to be comparable in size (r {approx} 2 AU) to the solar system's asteroid belt, thus joining {zeta} Lep (HD 38678, reported previously) to comprise the only two resolved sources of that class. Two additional sources (HD 95418 and HD 139006) show spatial extents that imply disk radii of {approx}1-3 AU, although the excess IR fluxes are not formally detected with better than 2{sigma} significance. For the unresolved sources, the upper limits on the maximum radii of mid-IR disk emission are in the range {approx}1-20 AU, four of which are comparable in radius to the asteroid belt. We have compared the global color temperatures of the dust to that expected for the dust in radiative equilibrium at the distances corresponding to the observed sizes or limits on the sizes. In most cases, the temperatures estimated via these two methods are comparable, and therefore, we see a generally consistent picture of the inferred morphology and the global mid-IR emission. Finally, while our sample size is not statistically significant, we note that the older sources (>200 Myr) host much warmer dust (T {approx}> 400 K) than younger sources (in the tens of Myr).

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗