Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

A semi-automatic measuring machine

A machine designed to locate automatically a star image on a photographic plate from approximate coordinates on a punched card and to measure and record its position to a micron is described. The main frame of the machine is of granite, as are the x and y coordinate carriages which move on air bearings against granite ways. The system is capable of making measurements continuously over a 10 x 10 inch range by means of a Ferranti moire fringe system, with a least count of one micron.

Strand, K. A.↗

Surface colour photometry of galaxies with Schmidt telescopes.

A method is described which owes its practicality to the capability of Schmidt telescopes to record a number of galaxy images on a single plate and to the existence of high speed computer controlled area-scanning precision microdensitometers such as the Photometric Data Systems model 1010. The method of analysis results in quantitative color-index information which is displayed in a manner that allows any user to effectively study the morphological properties of the distribution of color-index in galaxies.

Wray, J. D.↗

Curved-channel microchannel array plates

The microchannel array plate (MCP) is a photoelectric detector with an imaging capability comparable to that of a photographic plate. Recently MCPs in which the channels are curved to inhibit ion feedback have become available. These devices represent a major advance in MCP technology, since a single curved-channel MCP can be operated stably at high gain in the pulse-counting mode without any of the problems of stability of response or short lifetime reported for 'chevron' MCP detectors. Attention is given to the mode of operation of channel electron multipliers (CEM) and MCP, curved-channel MCP, test procedures, and performance characteristics. The accumulated test data show that the fundamental operating characteristics of the curved-channel MCP are directly related to those for the CEM.

Timothy, J. G.↗

Multiple object fiber optic spectroscopy

The Steward Observatory of the University of Arizona employs short optical fiber lengths to bring light from galaxy images at the 2.3 m telescope's focus to a line along a spectrograph slit, thereby obtaining simultaneous spectra of many objects of the field of view. After describing this instrument, attention is given to the development of an improved version through which efficiency gains will be obtained by remotely positioning the fibers under computer control and by correctly matching fiber outputs to the spectrograph optics. A CCD will replace the presently employed image tube and photographic plate detector system, in order to permit sky subtraction, yield increased dynamic range, and provide more accurate wavelength calibration due to the detector's fixed format.

Hill, J. M.↗

Measuring: The quantifying art

The photograph of a comet or asteroid against background stars contains information in analog form regarding the relative positions of comet and star images. Measuring is the procedure for covnerting this information to digital form for computation of the object's accurate equatorial coordinates at the time of observation. The use of one- and two-coordinate measuring engines to measure the positions of images which may be elongated, comatic, or both, as well as round images is discussed along with the training of novice measurers to cope with such images. The grading of plates for potential accuracy of positions, preparation of plates for measuring, the accuracy of measurement, effects of telescope focal length and reduction technique upon the accuracy of positions, and the procedures and checks which may prevent erroneous positions also are discussed.

Gibson, J.↗

4U1722 + 11 - The discovery of an X-ray selected BL Lac object

The Uhuru X-ray source 4U1722 + 11 was observed using the microchannel-plate detector (High Resolution Imager) on the Einstein Observatory, and its coordinates measured to a precision of about 5 arcsec. A 16th-magnitude stellar object within the error circle was observed spectroscopically at CTIO, and at the AAT, and found to have a featureless continuum. Subsequent radio observations at the VLA have established that the object is a radio source at the level of 60 mJy, and optical polarization measurements have determined that the source exhibits variable polarization at the level of 10 percent. On the basis of these observations, it is concluded that 4U1722 + 11 is a member of the class of objects known as X-ray selected blazars of BL Lac objects.

Griffiths, R. E.↗

Report of the panel on plate motion and deformation, section 2

Given here is a panel report on the goals and objectives, requirements and recommendations for the investigation of plate motion and deformation. The goals are to refine our knowledge of plate motions, study regional and local deformation, and contribute to the solution of important societal problems. The requirements include basic space-positioning measurements, the use of global and regional data sets obtained with space-based techniques, topographic and geoid data to help characterize the internal processes that shape the planet, gravity data to study the density structure at depth and help determine the driving mechanisms for plate tectonics, and satellite images to map lithology, structure and morphology. The most important recommendation of the panel is for the implementation of a world-wide space-geodetic fiducial network to provide a systematic and uniform measure of global strain.

Bock, Yehuda↗

Laboratory calibration and characterization of video cameras

Some techniques for laboratory calibration and characterization of video cameras used with frame grabber boards are presented. A laser-illuminated displaced reticle technique (with camera lens removed) is used to determine the camera/grabber effective horizontal and vertical pixel spacing as well as the angle of nonperpendicularity of the axes. The principal point of autocollimation and point of symmetry are found by illuminating the camera with an unexpanded laser beam, either aligned with the sensor or lens. Lens distortion and the principal distance are determined from images of a calibration plate suitably aligned with the camera. Calibration and characterization results for several video cameras are presented. Differences between these laboratory techniques and test range and plumb line calibration are noted.

Burner, A. W.↗

Structural properties of compact groups

We report the results of a systematic study of galaxies in the regions of Hickson compact groups. Our sample is composed of the 22 Hickson groups which are located in the southern hemisphere and have cz less than 9000 km/s. Making use of digitized images of IIIa-J plates that cover an area of 0.5 x 0.5 deg around each group, we were able to detect and classify images down to a magnitude limit of 19.5 in the B band. This limit is typically three magnitudes fainter than previous studies. Most groups show a statistically significant excess of fainter galaxies compared to the background. These fainter galaxies typically have a somewhat more extended spatial distribution than the brighter galaxies originally classified by Hickson. Our data suggest that Hickson groups have a wide range in density and radius, ranging from very compact structures with overdensities of the order of 10(exp 2) and crossing times of roughly 0.01 H(sub 0 sup -1), to much more diffuse structures, similar to loose groups, with overdensities of about 3 and crossing times of roughly 0.5 H(sub 0 sup -1).

De Carvalho, R. R.↗

Laboratory Calibration and Characterization of Video Cameras

Some techniques for laboratory calibration and characterization of video cameras used with frame grabber boards are presented. A laser-illuminated displaced reticle technique (with camera lens removed) is used to determine the camera/grabber effective horizontal and vertical pixel spacing as well as the angle of non-perpendicularity of the axes. The principal point of autocollimation and point of symmetry are found by illuminating the camera with an unexpanded laser beam, either aligned with the sensor or lens. Lens distortion and the principal distance are determined from images of a calibration plate suitable aligned with the camera. Calibration and characterization results for several video cameras are presented. Differences between these laboratory techniques and test range and plumb line calibration are noted.

Burner, A. W.↗

Fiber-Optic Bragg Gratings and Optical Holography Compared as Vibration Detectors

The NASA Glenn Research Center is interested in determining structural damage in engine components during flight to evaluate the health of aerospace propulsion systems. On the ground, we can use holography to detect structural damage by examining the characteristic mode shapes and frequencies of vibrating objects. We are studying the feasibility of using embedded fiber Bragg gratings (FBGs) to accomplish this goal in a flight-worthy system, by using the minimal intrusion and high sensitivity afforded by fiber optics. We have recently compared holographically imaged modes of vibrating plates with the corresponding dynamic strains detected by embedded FBGs. We constructed an experimental setup for studying the responses of FBGs to dynamic excitations. One of the plates was made of a polymer matrix composite (PMC) with an FBG embedded in it, and the other one was made of copper with surface-mounted FBGs. The instrumented plates were mounted and vibrated, and time-averaged holography was used to measure their surface displacements. Simultaneously, the signals from the FBGs were detected and sent via fiber-optic cable to a quiet location about 20 m away for interrogation. The the test configuration used for the PMC plate is shown. Experimental results are also shown. The FBG was embedded in the middle of the PMC plates, roughly within the center circular fringe in each of the interferograms shown. Two resonant excitation frequencies were used: 706 and 3062 Hz. The plot in this paper shows a larger FBG signal at the higher frequency; this is because the plate bends more at higher order resonant modes, causing higher strain. This contrasts to the smaller displacements characteristic of higher frequencies, which are measured by holographic techniques.

Adamovsky, Grigory↗

Real-time observation of X-ray diffraction patterns with the Lixiscope

The feasibility of the Lixiscope (Low Intensity X-ray Imaging Scope) is demonstrated for real-time observation of transmission Laue patterns. Making use of the high-gain capability of microchannel plate (MCP) visible-light image intensifier tubes, X-ray images are converted to visible-light images by a scintillator. Pb discs are taped to the center of the Lixiscope input face, and crystal samples are held on a goniometer stage with modeling clay. With a compact size to facilitate off axis viewing, and real-time viewing to allow instantaneous response, the Lixiscope may prove useful in dynamic studies of the effects of plastic flows, stresses, high pressures, and low temperatures.

Chung, D. Y.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Thermal response of solar receiver aperture plates during sun walk-off

The tracking mechanism for a point-focusing concentrator may be subject to failure. If this should occur, the solar image will travel across the aperture plate, and it may also impinge on the adjacent support structure. Such an event is called 'sun walk-off'. The present investigation is concerned with the transient response of different aperture plate materials to the intense heating produced in a typical walk-off situation for parabolic dish concentrators. Receivers for two solar module systems are considered, including a high-temperature receiver that utilizes a 2-milliradian (mrad) concentrator, and a lower-temperature receiver which is coupled with a 4-mrad concentrator. It is found that during a walk-off situation the solar image travels in a straight line in the radial direction. The results obtained for a copper aperture plate were disappointing. It appears that passive metallic plates without cooling or other protective support cannot withstand the intense heating.

Wen, L.↗

Coded aperture devices for viewing extended objects from space

Coded aperture sensors for photons or energetic neutral atoms (ENAs), which incorporate FOV limiters and subdivide the object field into a number of elements which is smaller than the number of detector pixels, are described. A least squares fit to the data is made in reconstructing the object field. To evaluate the optics and reconstruction algorithms, two 'breadboard' sensors have been constructed, one based on a film camera and the other upon a UV-light sensitive microchannel plate detector system. Results obtained thus far show that the concept is viable, and no special difficulties should be encountered in adapting the detector geometries to neutral particle imaging systems. Charged particle deflection plates could be incorporated into the region between the FOV limiter and the aperture, or installed ahead of the limiter.

Curtis, C. C.↗

Identification of geostructures of continental crust particularly as they relate to mineral resource evaluation

The author has identified the following significant results. Preliminary examination of ERTS-1 imagery in central and northern Alaska substantiates the existence of a conjugate set of northeast and northwest faults suggested by linears noted on Nimbus 4 images. Linears of both trends are well expressed and several have been mapped as faults, including the Shaw Creek fault. Imagery provides new data to support the interpretation that the Kobuk Trench is the northern margin of a broad west-trending fault zone bounded on the north and south by strike-slip faults. In northwestern Alaska, MSS band 5 imagery shows Mississippian limestone as white, while shale, sandstone, and chert of other ages appear dark. As the limestone is the basal formation of the numerous thrust plates stacked in the area, images of band 5 will assist significantly in depicting the distribution of the thrust plates. In south-central Alaska the newly described Totshunda fault is readily identified and extends into areas not yet mapped. Also shown is another fault parallel to the south of the Totshunda which has not yet been recognized in the field.

Gryc, G.↗