Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Establishing Isotopic Measurement Capabilities using Laser-Induced Breakdown Spectroscopy for the Molten Salt Reactor Campaign

Proof-of-principle H isotope ratios of aqueous aerosol systems and liquid droplets on filter paper have been measured using laser-induced breakdown spectroscopy (LIBS) with root mean square error of prediction values down to 1.9%. Molten salt reactors (MSRs) will consist of a complex chemical and radiological system consistently producing new fission products as the reactor operates. Some of these fission products and/or their daughter species will leave the salt in the reactor off-gas. Monitoring the composition of the off-gas, as well as the salt itself, is important for monitoring reactor performance, including burnup, corrosion, and the concentration of impurities. Tritium is of concern for MSRs because it will be produced from the irradiation of key salt constituents, including Li and Be. LIBS offers an avenue for in situ salt and off-gas monitoring by firing a laser onto or into the sample stream to generate a plasma. The plasma light can be monitored to measure an elemental fingerprint of the sample. Extending this analysis to include isotopic ratios offers a critical expansion of the in situ monitoring capabilities being developed. This study demonstrates the expansion of Oak Ridge National Laboratory’s LIBS capabilities to monitor isotopes and shows how simple calibrations may provide rapid semiquantitative models.

07 ISOTOPE AND RADIATION SOURCES↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

The Long Neglected Cycloidal Mass Analyzer

Cycloid mass spectrometers offer powerful advantages for isotope ratio measurements, including double focusing (mass and energy), linear mass dispersion over a large spatial area, and a small footprint. However, the linear cycloid has not been adopted as widely as other mass analyzer designs, in part because of challenges with utilizing common ion detectors such as electron multipliers and Faraday cups. Integration of a linear cycloid with a capacitive transimpedance amplifier detector arrays can overcome these challenges, resulting in a compact powerful mass spectrometer for precision isotope ratio measurements.

47 OTHER INSTRUMENTATION↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Complex multicomponent spectrum analysis with Deep Neural Network

Here, in this paper, we present the use of deep neural networks to estimate physical parameters from complex optical emission spectra of the D β /H β transition. Specifically, we focus on estimating the radio frequency electric field vector of the lower hybrid wave and isotope ratio within the scrape-off-layer plasma of the WEST tokamak. Fitting the spectral data using a traditional non-linear least squares analysis requires many free parameters and is computationally expensive, rendering the data unusable for real-time control. By implementing relatively small neural networks, the physical parameters can be directly extracted from the spectral data with reasonable accuracy in a few milliseconds. The deep neural network prediction can serve as input for a reduced model using least-squares fitting or for real-time control. We show that deep neural networks can be an effective tool for analyzing complex multicomponent spectra, providing a speedup of more than 10 5 times compared to least residual analysis, with an accuracy of 0.5% for the isotope ratio, and 0.09 kV/cm and 0.38 kV/cm for the RF radial and poloidal electric field respectively.

47 OTHER INSTRUMENTATION↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UO2 microstructural evolutions induced by Ni, Mo, and W dopants for intentional forensics

The concept of tagging nuclear fuel with a chemical barcode to enable forensics analysis across the nuclear fuel cycle is an area of active investigation, particularly to ensure fabrication viability without disrupting current fuel performance. This study explored the feasibility of using Ni, Mo, and W isotopic double-spikes as dopants in UO2 fuel from the perspective of fuel fabrication. Doped UO2 pellets were produced using conventional fuel fabrication processes, including powder mixing, sieving, pressing, and sintering in a reductive atmosphere. Two composition levels, 100 and 1000 ppm, were evaluated for each dopant element with isotopic double-spike configurations. For the Ni system, additional dopant concentrations of 250 and 500 ppm were produced with nonperturbed isotopic ratios. The results demonstrated that successful incorporation of Ni, Mo, and W double-spikes into UO2 pellets occurred with minimal shift in final density or dopant loss during pellet fabrication. Isotopic analysis confirmed the presence of the double-spike signature even when diluted with natural isotopic material in ratio of 1:5 in the fabrication process. Microstructural examinations revealed different impacts on grain size compared with undoped UO2. This study showed that Ni incorporation up to ∼500 ppm promoted moderate grain growth, whereas the Mo and W systems caused grain size reduction at all concentrations. Changes in the UO2 lattice parameter as a function of composition were detected exclusively for Ni up to 500 ppm, indicating that the Ni solid solution was the main factor for the observed grain growth. Insoluble (Mo and W) or supersaturated (Ni > 500 ppm) conditions produced grain size reduction. The Ni-doped pellets in the solution range resulted in a final microstructure within fuel specifications, demonstrating its potential benefits of employing complex dopant systems for potential nuclear forensic applications.

36 MATERIALS SCIENCE↗

Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials

Here, we present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post-detonation nuclear forensics. The glasses were generated by melting and then quenching SiO 2 , Al 2 O 3 and CaCO 3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235 U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g -1 . Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry-single stage accelerator mass spectrometry [SIMS-SSAMS], large geometry [LG] - SIMS, and laser ablation-inductively coupled plasma-mass spectrometry [LA-ICP-MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.

36 MATERIALS SCIENCE↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

AmeriFlux FLUXNET-1F US-ARM ARM Southern Great Plains site- Lamont

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont. This is the FLUXNET version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont produced by applying the standard ONEFlux (1F) software. Site Description - Central facility tower crop field (winter wheat, corn, soy, alfalfa). The site also has continuous measurements of precise mixing ratios of CO2, CH4, CO, N2O, and isotopic ratio of 13CO2. In addition to 4 m system, there are sonic anemometers at 25 m and 60 m.

Biraud, Sebastien↗

Chemical Compositions of Red Giant Stars from Habitable Zone Planet Finder Spectroscopy

We have used the Habitable Zone Planet Finder (HPF) to gather high-resolution, high signal-to-noise near-infrared spectra of 13 field red horizontal branch (RHB) stars, one open cluster giant, and one very metal-poor halo red giant. The HPF spectra cover the 0.81–1.28 μm wavelength range of the zyJ bands, partially filling the gap between the optical (0.4–1.0 μm) and infrared (1.5–2.4 μm) spectra already available for the program stars. We derive abundances of 17 species from LTE-based computations involving equivalent widths and spectrum syntheses, and estimate abundance corrections for the species that are most affected by departures from LTE in RHB stars. Generally good agreement is found between HPF-based metallicities and abundance ratios and those from the optical and infrared spectral regions. Light element transitions dominate the HPF spectra of these red giants, and HPF data can be used to derive abundances from species with poor or no representation in optical spectra (e.g., C i, P i, S i, K i). Attention is drawn to the HPF abundances in two field solar-metallicity RHB stars of special interest: one with an extreme carbon isotope ratio, and one with a rare, very large lithium content. The latter star is unique in our sample in exhibiting very strong He i 10830 Å absorption. The abundances of the open cluster giant concur with those derived from other wavelength regions. Detections of C i and S i in HD 122563 are reported, yielding the lowest metallicity determination of [S/Fe] from more than one multiplet.

47 OTHER INSTRUMENTATION↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗