Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Propagation of Secondary Antiprotons and Cosmic Rays in the Galaxy

Recent more accurate antiproton data obtained by the BESS team during the last solar minimum pose a challenge to conventional propagation models of cosmic rays. In particular, the diffusive reacceleration model, which matches well key secondary/primary isotope ratios in cosmic rays, fails to reproduce the secondary antiproton spectrum. Tuning both secondary/primary isotope ratios and antiprotons is possible, but requires artificial breaks in the diffusion coefficient and the injection spectrum of primaries. We will discuss some possibilities to overcome these difficulties in the propagation models. We will present new results of our calculation of CR propagation in the Galaxy using the GALPROP code.

Moskalenko, I. V.↗

In Situ Measurement of Atmospheric Krypton and Xenon on Mars with Mars Science Laboratory

Mars Science Laboratorys Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking missions krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.

Conrad, P. G.↗

Isotopic compositions of rare gases in the carbonaceous chondrites Mokoia and Allende.

The isotopic compositions have been measured mass spectrometrically for neon, argon, krypton and xenon released from the carbonaceous chondrites Mokoia and Allende in stepwise heating experiments. The isotopic compositions of rare gases released from the meteorites at different temperatures varied quite considerably. A marked enrichment of Xe129 due to the decay of extinct nuclide I129 was observed in both meteorites. The variations of the isotopic ratios are partly caused by the presence of cosmic-ray spallation and neutron-capture products. In addition, however, a marked trend of mass-dependent variation of the isotopic ratios was observed in this work. The rare gas isotopes released from the meteorites appear to be systematically mass-fractionated relative to the relative abundances of the average carbonaceous chondrite. It seems that this phenomenon can be best explained as due to the fact that there exist reservoirs of two isotopically distinct gases in the meteorites and mixtures of these gases are being released at each temperature fraction.

Manuel, O. K.↗

The shocking development of lithium (and boron) in supernovae

It is shown that significant amounts of Li-7 and B-11 are produced in Type 2 supernovae. The synthesis of these rare elements occurs as the supernova shock traverses the base of the hydrogen envelope burning He-3 to masses 7 and 11 via alpha capture. The yields in this process are sufficient to account for the difference in lithium abundance observed between Pop 2 and Pop 1 stars. Since lithium (and boron) would, in this manner, be created in the same stars that produce the bulk of the heavy elements, the lithium abundance even in old Pop 1 stars would be high (as observed). The B-11 production may remedy the long-standing problem of the traditional spallation scenario to account for the observed isotopic ratio of boron. Observational consequences of this mechanism are discussed, including the evolution of lithium and boron isotope ratios in the Galaxy and the possible use of the boron yields to constrain the number of blue progenitor Type 2 supernovae.

Dearborn, David S. P.↗

The shocking development of lithium (and boron) in supernovae

It is shown that significant amounts of Li-7 and B-11 are produced in Type 2 supernovae. The synthesis of these rare elements occurs as the supernova shock traverses the base of the hydrogen envelope burning He-3 to masses 7 and 11 via alpha capture. The yields in this process are sufficient to account for the difference in lithium abundance observed between Pop 2 and Pop 1 stars. Since lithium (and boron) would, in this manner, be created in the same stars that produce the bulk of the heavy elements, the lithium abundance even in old Pop 1 stars would be high (as observed). The B-11 production may remedy the long-standing problem of the traditional spallation scenario to account for the observed isotopic ratio of boron. Observational consequences of this mechanism are discussed, including the evolution of lithium and boron isotope ratios in the Galaxy and the possible use of the boron yields to constrain the number of blue progenitor Type 2 supernovae.

Dearborn, David S. P.↗

On the origin and evolution of isotopes of carbon, nitrogen, and oxygen

Calculations of CNO processing in stellar envelopes, based on theoretical nucleosynthesis rather than empirical abundances in evolving stars, are presented and used in two models for the chemical evolution of the solar neighborhood. Seven stable isotopes are considered: C-12, C-13, N-14, N-15, O-16, O-17, and O-18. The two models ('infall' and 'initial-burst') represent extremes of types consistent with general constraints and include theoretical estimates of other nucleosynthesis sites and yields for CNO isotopes. The results obtained are found to predict that all CNO isotopes are produced mainly by stars with lifetimes much less than the age of the Galaxy (even at the present time when low-mass stars have the greatest death rate), so that isotopic ratios evolve very slowly after the first few billion years. Consequences of these slow changes are that the isotopic ratios cannot be employed to test between alternative hypotheses and that galactic evolution does not seem to be able to account for the apparent difference between the C-13/C-12 ratio in the solar system and in molecular clouds. The predicted envelope processing is shown to lead to approximately the solar-system values for the C-13/C-12 and O-17/O-16 abundance ratios but to a N-14/C-12 ratio that is too small by at least a factor of 2.

Dearborn, D.↗

Rapidly Assessing Changes in Bone Mineral Balance Using Natural Stable Calcium Isotopes

We demonstrate that variations in the Ca isotope ratios in urine rapidly and quantitatively reflect changes in bone mineral balance. This variation occurs because bone formation depletes soft tissue of light Ca isotopes, while bone resorption releases that isotopically light Ca back into soft tissue. In a study of 12 individuals confined to bed rest, a condition known to induce bone resorption, we show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker, while bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged. Ca isotopes can in principle be used to quantify net changes in bone mass. Ca isotopes indicate an average loss of 0.62 +/- 0.16 % in bone mass over the course of this 30-day study. The Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

Morgan, J. L. L.↗

Recognizing the Effects of Terrestrial Contamination on D/H Ratios in Shergottite Phosphates

Hydrogen isotope ratios in shergottite phosphate minerals have been investigated by SIMS in the meteorites Queen Alexandra Range (QUE) 94201 and Los Angeles. We have also collected electron probe data on these phosphates in order to characterize the phosphate minerals and attempt to document any potential hydrogen isotopic differences between chlor-apatite and whitlockite. In the section of Los Angeles we studied (748), we found both chlor-apatite and whitlockite, but in the section of QUE 94201,38 studied, we found only whitlockite. In both meteorites, D/H ratios (expressed in units of delta D (sub SMOW) vary, from terrestrial values up to approximately 5400%o in QUE 94201, and to approximately 3800%o in Los Angeles. We have carefully examined the ion probed pits with high-resolution FE-SEM. In most cases where the D/H ratios are low, we have iden-tified cracks that instersect the ion probe pit. These cracks are not visible in the optical microscope attached to the SIMS instument, making them impossible to avoid during SIMS data collection. We contend that the low ratios are a function of substantial terrestrial contamination, and that similar contamination is a likely factor in previously published studies on D/H ratios in martian phosphates. Here we highlight the difficulty of attempts to constrain the martian mantle D/H ratio using phosphate data, given that both terrestrial contamination and martian mantle hydrogen will move phosphate D/H ratios in the same direction, toward lower values. We note that our data include some of the most deuterium-rich values ever reported for martian phosphates. It is clear that some of our measurements are only minimally or totally uncontaminated, but the question arises, are intermediate values diminished because of true martian variability, or do they reflect contamination?

Ross, D. K.↗

Noble gases in presolar diamonds I: Three distinct components and their implications for diamond origins

High-purity separates of presolar diamond were prepared from 14 primitive chondrites from 7 compositional groups. Their noble gases were measured using stepped pyrolysis. Three distinct noble gas components are present in diamonds, HL, P3, and P6, each of which is found to consist of five noble gases. P3, released between 200 C and 900 C, has a 'planetary' elemental abundance pattern and roughly 'normal' isotopic ratios. HL, consisting of isotopically anomalous Xe-HL and Kr-H, Ar with high Ar-38/Ar-36, and most of the gas making up Ne-A2 and He-A, is released between 1100 C and 1600 C. HL has 'planetary' elemental ratios, except that it has much more He and Ne than other known 'planetary' components. HL gases are carried in the bulk diamonds, not in some trace phase. P6 has a slightly higher median release temperature than HL and is not cleanly separated from HL by stepped pyrolysis. Our data suggest that P6 has roughly 'normal' isotopic compositions and 'planetary' elemental ratios. Both P3 and P6 seem to be isotopically distinct from P1, the dominant 'planetary' noble-gas component in primitive chondrites. Release characteristics suggest that HL and P6 are sited in different carriers within the diamond fractions, while P3 may be sited near the surfaces of the diamonds. We find no evidence of separability of Xe-H and Xe-L or other isotopic variations in the HL component. However, because approximately 10(exp 10) diamonds are required to measure a Xe composition, a lack of isotopic variability does not constrain diamonds to come from a single source. In fact, the high abundance of diamonds in primitive chondrites and the presence of at least three distinct noble-gas components strongly suggest that diamonds originated in many sources. Relative abundances of noble-gas components in diamonds correlate with degree of thermal processing, indicating that all meteorites sampled essentially the same mixture of diamonds. That mixture was probably inherited from the Sun's parent molecular cloud.

Huss, Gary R.↗

Hafnium isotope variations in oceanic basalts

Hafnium isotope ratios generated by the beta(-) decay of Lu-176 are investigated in volcanic rocks derived from the suboceanic mantle. Hf-176/Hf-177 and Lu/Hf ratios were determined to precisions of 0.01-0.04% and 0.5%, respectively, by routine, low-blank chemistry. The Hf-176/Hf-177 ratio is found to be positively correlated with the Nd-143/Nd-144 ratio and negatively correlated with the Sr-87/Sr-86 and Pb-206/Pb-204 ratios, and to increase southwards along the Iceland-Reykjanes ridge traverse. An approximate bulk earth Hf-176/Hf-177 ratio of 0.28295 is inferred from the bulk earth Nd-143/Nd-144 ratio, which requires a bulk earth Lu/Hf ratio of 0.25, similar to the Juvinas eucrite. Midocean ridge basalts are shown to account for 60% of the range of Hf isotope ratios, and it is suggested that Lu-Hf fractionation is decoupled from Sm-Nd and Rb-Sr fractionation in very trace-element-depleted source regions as a result of partial melting.

Patchett, P. J.↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

Niemann, Hasso B.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, methane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, H.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of mlz from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, Hasso↗

The nakhlite meteorites: Augite-rich igneous rocks from Mars

The seven nakhlite meteorites are augite-rich igneous rocks that formed in flows or shallow intrusions of basaltic magma on Mars. They consist of euhedral to subhedral crystals of augite and olivine (to 1 cm long) in fine-grained mesostases. The augite crystals have homogeneous cores of Mg' = 63% and rims that are normally zoned to iron enrichment. The core-rim zoning is cut by iron-enriched zones along fractures and is replaced locally by ferroan low-Ca pyroxene. The core compositions of the olivines vary inversely with the steepness of their rim zoning - sharp rim zoning goes with the most magnesian cores (Mg' = 42%), homogeneous olivines are the most ferroan. The olivine and augite crystals contain multiphase inclusions representing trapped magma. Among the olivine and augite crystals is mesostasis, composed principally of plagioclase and/or glass, with euhedra of titanomagnetite and many minor minerals. Olivine and mesostasis glass are partially replaced by veinlets and patches of iddingsite, a mixture of smectite clays, iron oxy-hydroxides and carbonate minerals. In the mesostasis are rare patches of a salt alteration assemblage: halite, siderite, and anhydrite/ gypsum. The nakhlites are little shocked, but have been affected chemically and biologically by their residence on Earth. Differences among the chemical compositions of the nakhlites can be ascribed mostly to different proportions of augite, olivine, and mesostasis. Compared to common basalts, they are rich in Ca, strongly depleted in Al, and enriched in magmaphile (incompatible) elements, including the LREE. Nakhlites contain little pre-terrestrial organic matter. Oxygen isotope ratios are not terrestrial, and are different in anhydrous silicates and in iddingsite. The alteration assemblages all have heavy oxygen and heavy carbon, while D/H values are extreme and scattered. Igneous sulfur had a solar-system isotopic ratio, but in most minerals was altered to higher and lower values. High precision analyses show mass-independent fractionations of S isotopes. Nitrogen and noble gases are complex and represent three components: two mantle sources (Chas-E and Chas-S), and fractionated Martian atmosphere. The nakhlites are igneous cumulate rocks, formed from basaltic magma at approx.1.3 Ga, containing excess crystals over what would form from pure magma. After accumulation of their augite and olivine crystals, they were affected (to various degrees) by crystallization of the magma, element diffusion among minerals and magma, chemical reactions among minerals and magma, magma movement among the crystals, and post-igneous chemical equilibration. The extent of these modifications varies, from least to greatest, in the order: MIL03346, NWA817, Y000593, Nakhla = Governador Valadares, Lafayette, and NWA998. Chemical, isotopic, and chronologic data confirm that the nakhlites formed on Mars, most likely in thick lava flows or shallow intrusions. Their crystallization ages, referenced to crater count chronologies for Mars, suggest that the nakhlites formed on the large volcanic constructs of Tharsis, Elysium, or Syrtis Major. The nakhlites were suffused with liquid water, probably at approx.620 ma. This water dissolved olivine and mesostasis glass, and deposited iddingsite and salt minerals in their places. The nakhlites were ejected from Mars at approx.10.75Ma by an asteroid impact and fell to Earth within the last 10,000 years. Although the nakhlites are enriched in incompatible elements, their source mantle was strongly depleted. This depletion event was ancient, as the nakhlites source mantle was fractionated while short-lived radionuclides (e.g., t(sub 1/2 = 9 my) were still active. This differentiation event may have been core formation coupled with a magma ocean, as is inferred for the moon.

Treiman, Allan H.↗

Carbon Isotopic Measurements of Amino Acids in Stardust-Returned Samples

NASA's Stardust spacecraft returned to Earth samples from comet 81P/Wild 2 in January 2006. Preliminary examinations revealed the presence of a suite of organic compounds including several amines and amino acids, but the origin of these compounds could not be identified. Here, we present the carbon isotopic ratios of glycine and e-aminocaproic acid (EACA), the two most abundant amino acids, in Stardust-returned foil samples measured by gas chromatography-combustion-isotope ratio mass spectrometry coupled with quadrupole mass spectrometry (GC-CAMS/IRMS).

Elsila, Jamie↗

Microstructural Changes and Pb Mobility During the Zircon to Reidite Transformation: Implications for Planetary Impact Chronology

Impact events modify and leave behind a complex history of rock metamorphism on terrestrial planets. Evidence for an impact event may be recorded in physical changes to minerals, such as mineral deformation and formation of high P-T polymorphs, but also in the form of chemical fingerprints, such as enhanced elemental diffusion and isotopic mixing. Here we explore laboratory shock-induced physical and chemical changes to zircon and feldspar, the former of which is of interest because its trace elements abundances and isotope ratios are used extensively in geochemistry and geochronology. To this end, a granular mixture of Bishop Tuff sanidine and Kuehl Lake zircon, both with well characterized Pb isotope compositions, was prepared and then shocked via a flat plate accelerator. The peak pressure of the experiment, as calculated by the impedance matching method, was ~24 GPa although a broader range of P-T conditions is anticipated due to starting sample porosity. Unshocked and shocked materials were characterized via scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and Raman spectroscopy. These methods show that the starting zircon material had abundant metamict regions, and the conversion of the feldspar to glass in the post-shock material. Analyses of the shocked product also yielded multiple occurrences of the high-pressure ZrSiO 4 polymorph reidite, with some domains up to 300 μm across. The possibility of U-Pb system disturbance was evaluated via laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and secondary ion mass spectrometry (SIMS). The isotopic data reveal that disturbance of the U-Pb geochronometer in the reidite was minimal (<2% for the main U-Pb geochronometers). To better constrain the P-T conditions during the shock experiment, we complement impedance matching pressure calculations with iSALE2D impact simulations. The simulated results yield a range of P-T conditions experienced during the experiment and show that much of the sample may have reached >30 GPa, which is consistent with formation of reidite. In the recovered shocked material, we identified lamellae of reidite, some of which interlock with zircon lamellae. Reidite {112} twins were identified, which we interpret to have formed to reduce stress between the crystal structure of the host zircon and reidite. These two findings support the interpretation that shear transformation enabled the transition of zircon to reidite. The size and presence of reidite found here indicate that this phase is probably common in impact-shocked crustal rocks that experienced ~25 to ~35 GPa, especially when the target material has porosity. Additionally, shock loading of the zircon and transformation to reidite at these pressures in porous materials is unlikely to significantly disturb the U-Pb system in zircon and that the reidite inherits the primary U and Pb elemental and isotopic ratios from the zircon.

Bishop Tuff↗

Determination of the C-12/C-13 and O-16/O-18 ratio in the Martian atmosphere by 10 micron heterodyne spectroscopy

The planetary atmosphere of Mars was studied during the opposition of May, 1984, by means of a 10-micron heterodyne receiver mounted at the Cassegrain focus of a 3-m telescope. On the basis of a model of the Martian atmosphere, the isotopic ratios derived from the fully resolved absorption spectra obtained were compared with the results of Viking probe in situ measurements and terrestrial values; agreement is obtained within statistical errors. It is shown that highly resolving spectroscopy allows for the determination of isotopic ratios in remote sensing with a precision that is comparable to that of in situ mass spectroscopy.

Schrey, U.↗