Side extraction duoPIGatron-type ion source

We have designed and constructed a compact duoPIGatron-type ion source, for possible use in ion implanters, in which ions are extracted from a side aperture in contrast to conventional duoPIGatron sources with axial ion extraction. The size of the side extraction aperture is 1x40 mm{sup 2}. The ion source was developed to study physical and technological aspects relevant to an industrial ion source. The side extraction duoPIGatron has a stable arc, uniformly bright illumination, and dense plasma. The present work describes some operating parameters of the ion source using argon and BF{sub 3}. Total unanalyzed beam currents were 40 mA with Ar at an arc current of 7 A and 13 mA with BF{sub 3} gas at an arc current of 9 A.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time Profiles of Ions Produced in a Hot-Cavity Resonant Ionization Laser Ion Source

The time profiles of Cu, Sn and Ni ions extracted from a hot-cavity resonant ionization laser ion source are investigated. The ions are produced in the ion source by three-photon resonant ionization with pulsed Ti:Sapphire lasers. Measurements show that the time spread of these ions generated within laser pulses of about 30 ns could be larger than 100 s when the ions are extracted from the ion source. A one-dimensional ion-transport model using the Monte Carlo method is developed to simulate the time dependence of the ion pulses. The observed ion temporal profiles agree reasonably well with the predictions of the model, which indicates that a substantial fraction of the extracted ions are generated in the vapor-transfer tube rather than the hot cavity and that ion-wall collisions are suppressed inside the ion source by an undetermined ion confinement mechanism. Three-dimensional modeling will be necessary to understand the strong reduction in losses expected from ion-wall collisions which we interpret as evidence for confinement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion pair extractant selective for LiCl and LiBr

Improved methods for achieving the selective extraction of lithium salts from lithium sources, including rocky ores, salt-lake brines, and end-of-life lithium-ion batteries, could help address projected increases in the demand for lithium. Here, we report an ion pair receptor (2) capable of extracting LiCl and LiBr into an organic receiving phase both from the solid state and from aqueous solutions. Ion pair receptor 2 consists of a calix[4]pyrrole framework, which acts as an anion binding site, linked to a phenanthroline cation binding motif via ether linkages. Receptor 2 binds MgBr 2 and CaCl 2 with high selectivity over the corresponding lithium salts in a nonpolar aprotic solvent. The preference for Mg 2+ and Ca 2+ salts is reversed in polar protic media, allowing receptor 2 to complex LiCl and LiBr with high selectivity and affinity in organic media containing methanol or water. The effectiveness of receptor 2 as an extractant for LiCl and LiBr under liquid–liquid extraction (LLE) conditions was found to be enhanced by the presence of other potentially competitive salts in the aqueous source phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synergism by co-assembly at the origin of ion selectivity in liquid-liquid extraction

In liquid-liquid extraction, synergism emerges when for a defined formulation of the solvent phase, there is an increase of distribution coefficients for some cations in a mixture. To characterize the synergistic mechanisms, we determine the free energy of mixed co-assembly in aggregates. Aggregation in any point of a phase diagram can be followed not only structurally by SANS, SAXS, and SLS, but also thermodynamically by determining the concentration of monomers coexisting with reverse aggregates. Using the industrially used couple HDEHP/TOPO forming mixed reverse aggregates, and the representative couple U/Fe, we show that there is no peculiarity in the aggregates microstructure at the maximum of synergism. Nevertheless, the free energy of aggregation necessary to form mixed aggregates containing extracted ions in their polar core is comparable to the transfer free energy difference between target and nontarget ions, as deduced from the synergistic selectivity peak. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discharge Hollow Cathode and Extraction Grid Analysis for the MiXI Ion Thruster

Miniature ion thrusters are well-suited future space missions such as Terrestrial Planet Finder - Interferometer (TPF-I), where high efficiency thrusters using non-contaminating noble gas propellant are desirable. Transient dynamic and orbital analyses have shown that the low-noise, continuous thrust of the Miniature Xenon Ion (MiXI) thruster is desirable for TPF-I formation rotation maneuvers when compared with other thruster options [1], [2]. The 3cm diameter MiXI thruster, Figure 1, was originally designed using experimental methods and is capable of high Isp (> 3,000 sec), propellant efficiency > 80%, and thrust from <0.1 mN to >1.5 mN [3]. The MiXI thruster must demonstrate high levels of thrust resolution and a low minimum impulse bit to ensure it meets the precision formation flying needs of missions such as TPF-I. A novel concept for controlling the ion extraction voltages yields the necessary thrust characteristics for the MiXI thruster. Experiments verify these techniques and two dimensional computational models show that such techniques should have minimal effect on the lifetime of the thruster. During this effort, the MiXI thruster incorporates, for the first time, flight like hollow cathodes for both the discharge chamber and beam neutralization.

ions↗

Extraction and Acceleration of Ions from an Ion-Ion Plasma

Extraction and acceleration of positive and negative ions from a strong electronegative plasma and from an ion-ion plasma is investigated in the PEGASES thruster, working with SF{sub 6}. The plasma is generated in a cylindrical quartz tube terminated by metallic endplates. The electrons are confined by a static magnetic field along the axis of the cylinder. The electron mobility along the field is high and the electrons are determining the sheaths in front of the endplates. The core plasma potential can therefore be controlled by the bias applied to the endplates. An ion-ion plasma forms at the periphery as a result of electron confinement and ions can freely diffuse along the perpendicular direction or extraction axis. Langmuir probe and RFEA measurements are carried out along this axis. The measured ion energy distributions shows a single peak centered around a potential consistent with the plasma potential and the peak position could be controlled with a positive voltage applied to the endplates. When the endplates are biased negatively, the plasma potential saturates and remained close to 15 V. A beam of negatively charged particles can be observed under certain conditions when the endplates were biased negatively.

43 PARTICLE ACCELERATORS↗

Optimization of a tandem ion exchange—extraction chromatographic scheme for the recovery of strontium from raw urine

A previously reported ion-exchange/extraction chromatographic scheme for the recovery of radiostrontium from urine for subsequent determination is systematically optimized to minimize reagent consumption, enhance system reusability, and maximize sample throughput. In addition, a preliminary assessment of the effect of mobile phase flow rate on strontium uptake is described. Overall, the results show that the tandem system can be re-used without loss of performance, and that the rate at which samples can be processed by the system is ultimately limited by the time required for regeneration of the ion-exchange column and the kinetics of metal ion uptake on the extraction chromatographic sorbent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Potential uranium supply from phosphoric acid: A U.S. analysis comparing solvent extraction and Ion exchange recovery

Phosphate rock contains significant amounts of uranium, although in low concentrations. Recovery of uranium as a by-product from phosphoric acid, an intermediate product produced during the recovery of phosphorus from phosphate rock, is not unprecedented. Phosphoric acid plants ceased to produce uranium as a by-product in the early 1990s with the fall of uranium prices. In the last decade, this topic has regained attention due to higher uranium prices and expected increase in demand for uranium. Our study revisits the topic and estimates how much uranium might be recoverable from current phosphoric acid production in the United States and what the associated costs might be considering two different recovery processes: solvent extraction and ion exchange. Based on U.S. phosphoric acid production in 2014, 5.5 million pounds of U 3 O 8 could have been recovered, more than domestic U.S. mine production of uranium in the same year. Annualized costs for a hypothetical uranium recovery plant are US$48-66 per pound U 3 O 8 for solvent extraction, the process used historically in the United States to recover uranium from phosphoric acid. For ion exchange, not yet proven at a commercial scale for uranium recovery, the estimated costs are US$33-54 per pound U 3 O 8 . Our results suggest that it is technically possible for the United States to recover significant quantities of uranium from current phosphoric acid production. And for this type of uranium production to be economically attractive on a large scale, either recovery costs must fall or uranium prices rise.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Increase of Boron Ion Beam Current Extracted from a Multi-Cusp Ion Source in an Ion Doping System with Mass Separation

A multi-cusp ion source with large area extraction area has a capacity to extract high current ion beams. However it is difficult to obtain high current boron ion beams from boron trifluoride plasma as input power density is low and BF{sub 2}{sup +} is a main ion species. It was found that fluoride ion currents were selectively decreased by applying positive potential to a plasma electrode with respect to a plasma chamber. Using this method to a multi-cusp ion source with adequate magnet configuration, high current boron ion beams of 500 {mu}A/cm were obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface-functionalized polyolefin fibers and their use in methods for extracting metal ions from liquid solutions

A fiber useful in the absorption of metal ions from aqueous solutions, the fiber comprising a polyolefin backbone having a diameter of at least 1 micron and having covalently appended on its surface halogen atoms and vinyl-addition polymeric grafts functionalized with metal-binding groups, such as at least one functional group selected from carboxylate, keto, aldo, amino, imino, nitrile, amido, oxime, amidoxime, imide dioxime, and hydroxamate groups. The vinyl-addition polymeric grafts may also be further functionalized with hydrophilic groups different from the metal-binding groups, wherein the hydrophilic groups may be selected from carboxylate, sulfone, sulfonate, phosphonate, alkylammonium, iminium, amide, pyrrolidone, and polyalkyleneglycol groups. Also described are methods for producing the functionalized fibers, and methods for using the functionalized fiber, particularly in extracting metal ions from metal-containing solutions.

Dai, Sheng↗

Producing multicharged fullerene ion beam extracted from the second stage of tandem-type ECRIS

We have been constructing the tandem-type electron cyclotron resonance ion source (ECRIS). Two ion sources of the tandem-type ECRIS are possible to generate plasma individually, and they also confined individual ion species by each different plasma parameter. Hence, it is considered to be suitable for new materials production. As the first step, we try to produce and extract multicharged C{sub 60} ions by supplying pure C{sub 60} vapor in the second stage plasma because our main target is producing the endohedral fullerenes. We developed a new evaporator to supply fullerene vapor, and we succeeded in observation about multicharged C{sub 60} ion beam in tandem-type ECRIS for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel facility for 3D micro-irradiation of living cells in a controlled environment by MeV ions

We present a novel facility for micro-irradiation of living targets with ions from a 1.7 MV tandem accelerator. We show results using 1 MeV protons and 2 MeV He{sup 2+}. In contrast to common micro-irradiation facilities, which use electromagnetic or electrostatic focusing and specially designed vacuum windows, we employ a tapered glass capillary with a thin end window, made from polystyrene with a thickness of 1–2 μm, for ion focusing and extraction. The capillary is connected to a beamline tilted vertically by 45°, which allows for easy immersion of the extracted ions into liquid environment within a standard cell culture dish. An inverted microscope is used for simultaneously observing the samples as well as the capillary tip, while a stage-top incubator provides an appropriate environment for the samples. Furthermore, our setup allows to target volumes in cells within a μm{sup 3} resolution, while monitoring the target in real time during and after irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. This paper describes a hydrogen ion source which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency. A 1.3-cm-diam hollow cathode using a low work function material dispenser performed satisfactorily over a discharge current range of 10-90 A. Cylindrical probe measurements taken without ion extraction indicate maximum ion number densities on the order of 10 trillion/cu cm. Discharge durations ranged from 30 sec to continuous operation. Tests with beam extraction at 2.5 keV and 30 A discharge current yield average ion beam current densities of 0.1 A/sq cm over a 5-cm extraction diameter. Results of this study can be used to supply the baseline information needed to scale hollow cathodes for operation at discharge currents of hundreds of amperes using distributed cathodes.

Sovey, J. S.↗

An RF-only ion-funnel for extraction from high-pressure gases

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into a vacuum (10 -6 mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting 136 Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to simulations. This demonstration of extraction of ions, with mass comparable to that of the gas generating the high-pressure, has applications to Ba tagging from a Xe-gas time-projection chamber for double-beta decay, as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m > 40 u) carrier gas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of Mass Interferences Considering Charge Exchange Events and Dissociation of Molecular Ions During Extraction

Contamination due to mass interferences generally leads to severe problems in ion implantation. To be able to prevent this kind of contamination, the cause of the respective mass interference has to be known. Frequently, however, the transport mechanisms of the contamination are unknown and the search for potential transport mechanisms is troublesome. Simulation of mass interferences, therefore, is an excellent means to find potential transport mechanisms. In this paper, the simulation software ENCOTION (ENergetic COntamination simulaTION) is explained. In the latest version, an enhanced model was implemented in order to calculate the apparent mass of ions. The relevance of the new model is discussed by the example of tungsten contamination in the case of BF{sub 2}{sup +} implants. A new module that allows for the simulation of mass spectra was recently added to ENCOTION as a new feature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of 3D Code IBSimu for Designing an H{sup -}/D{sup -} Extraction System for the Texas A and M Facility Upgrade

A three dimensional ion optical code IBSimu is being developed at the University of Jyvaeskylae. So far the plasma modelling of the code has been restricted to positive ion extraction systems, but now a negative ion plasma extraction model has been added. The plasma model has been successfully validated with simulations of the Spallation Neutron Source (SNS) ion source extraction both in cylindrical symmetry and in full 3D, also modelling electron beam dumping and ion beam tilt. A filament-driven multicusp ion source has been installed at the Texas A and M University Cyclotron Institute for production of H{sup -} and D{sup -} beams as a part of the facility upgrade. The light ion beams, produced by the ion source, are accelerated with the K150 cyclotron for production and reacceleration of rare isotopes. The extraction system for the ion source was designed with IBSimu. The extraction features a water-cooled puller electrode with a permanent magnet dipole field for dumping the co-extracted electrons and a decelerating Einzel lens for adjusting the beam focusing for further beam transport. The ion source and the puller electrode are tilted at 4 degree angle with respect to the beam line. The extraction system can handle H{sup -} and D{sup -} beams with final beam energies from 5 keV to 15 keV using the same geometry, only adjusting the electrode voltages. So far, 24 {mu}A of H{sup -} and 15 {mu}A of D{sup -} have been extracted from the cyclotron.

43 PARTICLE ACCELERATORS↗