Design and experimental study of a secondary hohlraum radiation source with laser focal spots blocked

A design of secondary hohlraum radiation source with laser focal spots blocked is introduced. The hard x-ray radiation such as the gold M-band emission and hot electrons from the coronal plasma were designed to be shielded using a cylindrical shield. Three-dimensional view factor analysis was carried out to optimize the shield structure to achieve higher radiation temperature. An experiment was performed at Shenguang III prototype laser facility to verify the design. Velocity Interferometer System for Any Reflector was used to measure the shock wave speed in a three-stepped Al sample driven by this radiation source and the peak radiation temperature of the radiation source was estimated to be about 90 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Far-forward collective scattering measurements by FIR polarimeter-interferometer on J-TEXT tokamak

The multi-channel three-wave polarimeter-interferometer system on J-TEXT tokamak has been exploited to measure far-forward collective scattering from electron density fluctuations. The diagnostic utilizes far infrared lasers operated at 432 μm with 17-channel vertical chords (3 cm chord spacing), covering the entire cross section of plasma. Scattering laser power is measured using a high-sensitivity Schottky planar diode mixer which can also detect polarimetric and interferometric phase simultaneously. The system provides a line-integrated measurement of density fluctuations with maximum measurable wave number: k{sub ⊥max} ≤ 2 cm{sup −1} and time response up to 350 kHz. Feasibility of the diagnostic has been tested, showing higher sensitivity to detect fluctuation than interferometric measurement. Capability of providing spatial-resolved information of fluctuation has also been demonstrated in preliminary experimental applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic and time-resolving ability of pulse-pair two-dimensional velocity interferometry

Previous velocity interferometers used at research laboratories for shock physics experiments measured target motion at a point or many points on a line on the target. Recently, a two-dimensional (2d) version (2d-velocity interferometer system for any reflector) has been demonstrated using a pair of ultrashort (3 ps) pulses for illumination, separated by 268 ps. We have discovered new abilities for this instrument, by treating the complex output image as a hologram. For data taken in an out of focus configuration, we can Fourier process to bring narrow features such as cracks into sharp focus, which are otherwise completely blurred. This solves a practical problem when using high numerical aperture optics having narrow depth of field to observe moving surface features such as cracks. Furthermore, theory predicts that the target appearance (position and reflectivity) at two separate moments in time are recorded by the main and conjugate images of the same hologram, and are partially separable during analysis for narrow features. Hence, for the cracks we bring into refocus, we can make a two-frame movie with a subnanosecond frame period. Longer and shorter frame periods are possible with different interferometer delays. Since the megapixel optical detectors we use have superior spatial resolution over electronic beam based framing cameras, this technology could be of great use in studying microscopic three-dimensional-behavior of targets at ultrafast times scales. Demonstrations on shocked silicon are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium reconstruction based on core magnetic measurement and its applications on equilibrium transition in Joint-TEXT tokamak

Evaluation and reconstruction of plasma equilibrium, especially to resolve the safety factor profile, is imperative for advanced tokamak operation and physics study. Based on core magnetic measurement by the high resolution laser polarimeter-interferometer system (POLARIS), the equilibrium of Joint-TEXT (J-TEXT) plasma is reconstructed and profiles of safety factor, current density, and electron density are, therefore, obtained with high accuracy and temporal resolution. The equilibrium reconstruction procedure determines the equilibrium flux surfaces essentially from the data of POLARIS. Refraction of laser probe beam, a major error source of the reconstruction, has been considered and corrected, which leads to improvement of accuracy more than 10%. The error of reconstruction has been systematically assessed with consideration of realistic diagnostic performance and scrape-off layer region of plasma, and its accuracy has been verified. Fast equilibrium transitions both within a single sawtooth cycle and during the penetration of resonant magnetic perturbation have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗

Core density gradient fluctuation measurement by differential interferometry in the helically symmetric experiment stellarator

The interferometer system on the Helically Symmetric eXperiment (HSX) stellarator uses an expanded beam and linear detector array to realize a multichord measurement. Unlike conventional interferometry which determines the plasma phase shift with respect to a reference, directly evaluating the phase between two adjacent chords can be employed to measure the change in plasma phase with impact parameter. This approach provides a measure of the equilibrium density gradient or the density gradient fluctuations and is referred to as differential interferometry. For central chords, measurements are spatially localized due to a geometrical weighting factor and can provide information on core density gradient fluctuations. The measurement requires finite coherence between fluctuations in the two spatially offset chords. This technique is applied on the HSX stellarator to measure both broadband turbulence and coherent modes. Spatial localization is exploited to isolate core turbulence changes associated with change in magnetic configuration or heating location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with {approx}8 cm spacing. The source is a 432 {mu}m (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub Up-Tack} < 1.3 cm{sup -1}, corresponding k{sub Up-Tack }{rho}{sub s} < 1.3 ({rho}{sub s} is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity Interferometer blanking due to preheating in a double pulse planar experiment

Optical diagnostics, such as VISAR (Velocity Interferometer System for Any Reflector) or SOP (Streaked Optical Pyrometry), have become essential in shock timing experiments. Their high precision allows for accurate measurements of shock velocities, chronometry, and brightness temperature. However, in some instances, these measurements can be compromised. In planar shock coalescence experiments recently performed at the LULI facility [Baton et al., Phys. Rev. Lett. 108, 195002 (2012)], VISAR signal loss was observed. In these experiments, a strong shock launched by a high-intensity spike catches up with a previously shock launched by an earlier, low-intensity beam. The disappearance of the VISAR signal is attributed to a preheating of the coronal plasma by x-rays generated by the high intensity spike. The signal does not disappear if the high-intensity spike starts after VISAR probe beam begins to reflect off of the first shock. The VISAR diagnostic, modeled using an assessment of the optical index in quartz, compares favorably to experimental results. This provides evidence that x-ray preheating can cause blanking of the VISAR signal in quartz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Strength of Copper at High Pressures Using Pressure Shear Plate Experiments

Measurement of strength at high pressures is critical to understanding the behavior of materials subjected to extreme loading conditions. Recent developments have extended the pressure shear plate impact (PSPI) technique to the high-pressure regime. Such experiments provide a unique opportunity to extract the complete stress-strain behavior of materials at relatively high pressures. The modified technique includes a new fiber-optic heterodyne transverse velocity interferometer system and new analysis methods to account for the inelastic response of the anvil plates. In this study, PSPI experiments are conducted on oxygen-free high conductivity (OFHC) copper at pressures ranging from 10 to 43 GPa and at strain rates of ~10 5 s -1 . Complete stress-strain curves of copper are obtained using a hybrid methodology that relies on numerical simulations and particle velocity records gathered in these experiments. Experiments are conducted at similar pressures and strain rates using two types of anvils that undergo different levels of plastic strains: tool steel and tungsten carbide, to check the robustness of the hybrid method. The behavior of copper at these high pressures and strain rates is compared with previous literature data, and the effect of pressure and strain rate on the strength behavior of copper are discussed. Here, it was observed that the rate of change in yield strength change in pressure was 2.5 times the rate of change of shear modulus with pressure. The strength models that predict the response of copper at these extreme conditions are also examined and validated.

36 MATERIALS SCIENCE↗

An efficient method for unfolding kinetic pressure driven VISAR data

Velocity Interferometer System for Any Reflector (VISAR) [Barker and Hollenbach, J. Appl. Phys. 43, 4669 (1972)] is a well-known diagnostic that is employed on many shock physics and pulsed-power experiments. With the VISAR diagnostic, the velocity on the surface of any metal flyer can be found. For most experiments employing VISAR, either a kinetic pressure [Grady, Mech. Mater. 29, 181 (1998)] or a magnetic pressure [Lemke et al., Intl J. Impact Eng. 38, 480 (2011)] drives the motion of the flyer. Moreover, reliable prediction of the time-dependent pressure is often a critical component to understanding the physics of these experiments. Although VISAR can provide a precise measurement of a flyer’s surface velocity, the real challenge of this diagnostic implementation is using this velocity to unfold the time-dependent pressure. The purpose of this study is to elucidate a new method for quickly and reliably unfolding VISAR data.

42 ENGINEERING↗

Shock compression of FeOOH and implications for iron-water interactions in super-earth magma oceans

Iron(Fe)-water reactions in a magma ocean can influence water storage and density of planets. These reactions can form Fe-O-H phases, whose density, melting, and electronic properties at planetary interior conditions are important for informing planetary models. Here, we study natural goethite (α-FeOOH) that is shock-compressed along its principal Hugoniot. Analysis of our velocity interferometer system for any reflector (VISAR) results extends the equation of state to over 800 GPa. X-ray diffraction and VISAR reflectivity results indicate the onset of melting occurs at ~95 GPa with complete melting by 166 GPa, which may be relevant to low seismic velocity anomalies observed above the core-mantle boundary. Analysis of X-ray emission spectroscopy results up to 285 GPa shows the spin crossover of Fe, with dominantly low spin Fe above ~265 GPa in the melt, supporting formation of dense basal magma oceans in terrestrial planets. Using our measured FeOOH densities, we model planetary interiors up to 10 Earth masses. Assuming FeOOH forms via iron-water reactions, the radius decreases by up to 28%, while the density increases by up to 165% compared to the unreacted cases, providing an avenue to investigate water storage and evolution in super-Earths and sub-Neptunes.

Zhang, Yanyao [Stanford Univ., CA (United States)]↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elastic-plastic and phase transition of zinc oxide single crystal under shock compression

The Hugoniot data for zinc oxide (ZnO) single crystals were measured up to 80 GPa along both the 〈112{sup ¯}0〉 (a-axis) and 〈0001〉 (c-axis) directions using a velocity interferometer system for any reflector and inclined-mirror method combined with a powder gun and two-stage light gas gun. The Hugoniot-elastic limits of ZnO were determined to be 10.5 and 11.5 GPa along the a- and c-axes, respectively. The wurtzite (B4) to rocksalt (B1) phase transition pressures along the a- and c-axes are 12.3 and 14.4 GPa, respectively. Shock velocity (U{sub s}) versus particle velocity (U{sub p}) relation of the final phase is given by the following relationship: U{sub s} (km/s) = 2.76 + 1.51U{sub p} (km/s). Based on the Debye-Grüneisen model and Birch-Murnaghan equation of state (EOS), we discuss the EOS of the B1 phase ZnO. The bulk modulus (K{sub 0}) and its pressure derivative (K{sub 0}′) are estimated to be K{sub 0} = 174 GPa and K{sub 0}′ = 3.9, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a broadband reflectivity diagnostic for laser driven shock compression experiments

Here, a normal-incidence visible and near-infrared shock wave optical reflectivity diagnostic was constructed to investigate changes in the optical properties of materials under dynamic laser compression. Documenting wavelength- and time-dependent changes in the optical properties of laser-shock compressed samples has been difficult, primarily due to the small sample sizes and short time scales involved, but we succeeded in doing so by broadening a series of time delayed 800-nm pulses from an ultrafast Ti:sapphire laser to generate high-intensity broadband light at nanosecond time scales. This diagnostic was demonstrated over the wavelength range 450–1150 nm with up to 16 time displaced spectra during a single shock experiment. Simultaneous off-normal incidence velocity interferometry (velocity interferometer system for any reflector) characterized the sample under laser-compression and also provided an independent reflectivity measurement at 532 nm wavelength. The shock-driven semiconductor-to-metallic transition in germanium was documented by the way of reflectivity measurements with 0.5 ns time resolution and a wavelength resolution of 10 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sound velocity of tantalum under shock compression in the 18–142 GPa range

Dynamic compression experiments of tantalum (Ta) within a shock pressure range from 18–142 GPa were conducted driven by explosive, a two-stage light gas gun, and a powder gun, respectively. The time-resolved Ta/LiF (lithium fluoride) interface velocity profiles were recorded with a displacement interferometer system for any reflector. Sound velocities of Ta were obtained from the peak state time duration measurements with the step-sample technique and the direct-reverse impact technique. The uncertainty of measured sound velocities were analyzed carefully, which suggests that the symmetrical impact method with step-samples is more accurate for sound velocity measurement, and the most important parameter in this type experiment is the accurate sample/window particle velocity profile, especially the accurate peak state time duration. From these carefully analyzed sound velocity data, no evidence of a phase transition was found up to the shock melting pressure of Ta.

36 MATERIALS SCIENCE↗

Design and testing of a magnetically driven implosion peak current diagnostic

We report that a critical component of the magnetically driven implosion experiments at Sandia National Laboratories is the delivery of high-current, 10s of MA, from the Z pulsed power facility to a target. In order to assess the performance of the experiment, it is necessary to measure the current delivered to the target. Recent Magnetized Liner Inertial Fusion (MagLIF) experiments have included velocimetry diagnostics, such as PDV (Photonic Doppler Velocimetry) or Velocity Interferometer System for Any Reflector, in the final power feed section in order to infer the load current as a function of time. However, due to the nonlinear volumetrically distributed magnetic force within a velocimetry flyer, a complete time-dependent load current unfold is typically a time-intensive process and the uncertainties in the unfold can be difficult to assess. In this paper, we discuss how a PDV diagnostic can be simplified to obtain a peak current by sufficiently increasing the thickness of the flyer. This effectively keeps the magnetic force localized to the flyer surface, resulting in fast and highly accurate measurements of the peak load current. Additionally, we show the results of experimental peak load current measurements from the PDV diagnostic in recent MagLIF experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-inductive vertical position measurements by Faraday-effect polarimetry on EAST tokamak

Vertical instability control in an elongated plasma is highly desirable for a tokamak reactor. A multi-channel 694 GHz far-infrared laser-based polarimeter-interferometer system has been used to provide a non-inductive vertical position measurement in the long-pulse EAST tokamak. A detailed comparison of vertical position measurements by polarimetry and external inductive flux loops has been used to validate Faraday-effect polarimetry as an accurate high-time response vertical position sensor.