Engineering PapersSearch

SEARCH · Engineering Papers

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The James Webb Space Telescope: Capabilities for Exoplanet Science

The James Webb Space Telescope (JWST) is a large aperture (6.5 meter), cryogenic space telescope with a suite of near and mid-infrared instruments covering the wavelength range of 0.6 micron to 28 micron. JWST's primary science goal is to detect and characterize the first galaxies. It will also study the assembly of galaxies, stellar and planetary system formation, and the formation and evolution of planetary systems. We will review the design of JWST, and discuss the current status of the project, with emphasis on recent progress in the construction of the observatory. We also review the capabilities of the observatory for observations of exosolar planets and debris disks by means of coronagraphic imaging, and high contrast imaging and spectroscopy. This discussion will focus on the optical and thermal performance of the observatory, and will include the current predictions for the performance of the observatory, with special reference to the demands of exoplanet science observations.

Clampin, Mark

LANDSAT-4 Thematic Mapper Modulation Transfer Function (MTF) evaluation

Results of MTF analysis of imagery of the San Mateo Bridge are consistent on two TM image dates for bands 4,5, and 7. There are indications that bands 1, 2, and 3 suffer from low image contrast, and consequently low signal to noise in the derived MTFs. The two image analysis produced reasonable results along +45 deg and -45 deg azimuths in the 2-D MTF, but poor results along the 0 deg and 90 deg azimuths. The effective instantaneous field of view is given for each band, and the image contrast for water and the bridge are compared. Graphs show overall TM system MTFs.

Schowengerdt, R.

Advanced UVOIR Mirror Technology Development (AMTD) for Very Large Space Telescopes

ASTRO2010 Decadal Survey stated that an advanced large-aperture ultraviolet, optical, near-infrared (UVOIR) telescope is required to enable the next generation of compelling astrophysics and exoplanet science; and, that present technology is not mature enough to affordably build and launch any potential UVOIR mission concept. AMTD is the start of a multiyear effort to develop, demonstrate and mature critical technologies to TRL-6 by 2018 so that a viable flight mission can be proposed to the 2020 Decadal Review. AMTD builds on the state of art (SOA) defined by over 30 years of monolithic & segmented ground & space-telescope mirror technology to mature six key technologies: (1) Large-Aperture, Low Areal Density, High Stiffness Mirror Substrates: Both (4 to 8 m) monolithic and (8 to 16 m) segmented primary mirrors require larger, thicker, and stiffer substrates. (2) Support System: Large-aperture mirrors require large support systems to ensure that they survive launch and deploy on orbit in a stress-free and undistorted shape. (3) Mid/High Spatial Frequency Figure Error: Very smooth mirror is critical for producing high-quality point spread function (PSF) for high contrast imaging. (4) Segment Edges: The quality of segment edges impacts PSF for high-contrast imaging applications, contributes to stray light noise, and affects total collecting aperture. (5) Segment to Segment Gap Phasing: Segment phasing is critical for producing high-quality temporally-stable PSF. (6) Integrated Model Validation: On-orbit performance is driven by mechanical & thermal stability. Compliance cannot be 100% tested, but relies on modeling. AMTD is pursuing multiple design paths to provide the science community with options to enable either large aperture monolithic or segmented mirrors with clear engineering metrics traceable to science requirements.

Postman, Marc

Overview and Summary of Advanced UVOIR Mirror Technology Development (AMTD) Project

ASTRO2010 Decadal Survey stated that an advanced large-aperture ultraviolet, optical, near-infrared (UVOIR) telescope is required to enable the next generation of compelling astrophysics and exoplanet science; and, that present technology is not mature enough to affordably build and launch any potential UVOIR mission concept. AMTD is a multiyear effort to develop, demonstrate and mature critical technologies to TRL-6 by 2018 so that a viable flight mission can be proposed to the 2020 Decadal Review. AMTD builds on the state of art (SOA) defined by over 30 years of monolithic & segmented ground & space-telescope mirror technology to mature six key technologies: center dotLarge-Aperture, Low Areal Density, High Stiffness Mirror Substrates: Both (4 to 8 m) monolithic and (8 to 16 m) segmented telescopes require larger and stiffer mirrors. center dotSupport System: Large-aperture mirrors require large support systems to ensure that they survive launch, deploy on orbit, and maintain a stable, undistorted shape. center dotMid/High Spatial Frequency Figure Error: Very smooth mirror is critical for producing high-quality point spread function (PSF) for high contrast imaging. center dotSegment Edges: The quality of segment edges impacts PSF for high-contrast imaging applications, contributes to stray light noise, and affects total collecting aperture. center dotSegment to Segment Gap Phasing: Segment phasing is critical for producing high-quality temporally-stable PSF. center dotIntegrated Model Validation: On-orbit performance is driven by mechanical & thermal stability. Compliance cannot be 100% tested, but relies on modeling. Because we cannot predict the future, AMTD is pursuing multiple design paths to provide the science community with options to enable either large aperture monolithic or segmented mirrors with clear engineering metrics traceable to science requirements

Stahl, H. Philip

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey Telescope/Astrophysics Focused Telescope Assets (WFIRST/AFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC) cofigurations. We discuss why the lenslet array based IFS is selected for PISCES. We present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the specific function of our pinhole mask on the back surface of the lenslet array to further suppress star light introduced speckles. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Integral field spectrometer

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST-AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey Telescope/Astrophysics Focused Telescope Assets (WFIRST-AFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory (JPL) and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC) configurations. We discuss why the lenslet array based IFS was selected for PISCES. We present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the specific function of our pinhole mask on the back surface of the lenslet array to reduce the diffraction from the edge of the lenslets. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Wide-Field InfraRed Survey Telescope Astrophysics

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a prototype lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey TelescopeAstrophysics Focused Telescope Assets (WFIRSTAFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC). We will present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the compatibility to upgrade from the current 1k x 1k detector array to 4k x 4k detector array. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Integral Field Spectrometer

Laboratory Testing of a Phased Induced Amplitude Apodization (PIAA) Coronagraph

We present high-contrast images from laboratory testing of a Phase Induced Amplitude Apodization (PIAA) coronagraph at NASA's High Contrast Imaging Testbed (HCIT). Using a deformable mirror and wavefront estimation and control algorithms, we create a 'dark hole' in the monochromatic point-spread function with an inner working angle of (2.05 f lambda/D), with a mean intensity 3.5x10(exp -8). We discuss the contributions to this floor, and the techniques being developed to improve it. We also present simulations that investigate the effect of Lyot stops of various sizes, and conclude that a Lyot stop is necessary for 10(exp -9) performance but that an annular postapodizer is not necessary.

deformable mirror

SIM PlanetQuest Key Project Precursor Observations to Detect Gas Giant Planets Around Young Stars

We present a review of precursor observing programs for the SIM PlanetQuest Key project devoted to detecting Jupiter mass planets around young stars. In order to ensure that the stars in the sample are free of various sources of astrometric noise that might impede the detection of planets, we have initiated programs to collect photometry, high contrast images, interferometric data and radial velocities for stars in both the Northern and Southern hemispheres. We have completed a high contrast imaging survey of target stars in Taurus and the Pleiades and found no definitive common proper motion companions within one arcsecond (140 AU) of the SIM targets. Our radial velocity surveys have shown that many of the target stars in Sco-Cen are fast rotators and a few stars in Taurus and the Pleiades may have sub-stellar companions. Interferometric data of a few stars in Taurus show no signs of stellar or sub-stellar companions with separations of <5 mas. The photometric survey suggests that approximately half of the stars initially selected for this program are variable to a degree (1(sigma) >0.1 mag) that would degrade the astrometric accuracy achievable for that star. While the precursor programs are still a work in progress, we provide a comprehensive list of all targets ranked according to their viability as a result of the observations taken to date. By far, the observable that removes the most targets from the SIM-YSO program is photometric variability.

astrophysics

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik

The Sensitivity of Shaped Pupil Coronagraphs to Optical Aberrations

Unlike focal-plane coronagraphs that use occulting spots and Lyot stops to eliminate diffraction, pupil-plane coronagraphs operate by shaping the pupil to redirect the diffracted stellar light into a tight core. As in focal-plane coronagraphs, the optical aberrations in the telescope must be sufficiently corrected to enable high contrast imaging. However, in shaped-pupil coronagraphs, the low-order aberrations resulting from misalignment and optical figure drift have a much smaller influence upon the contrast at at the inner working angle. These weaker sensitivities greatly relax the strict low-order wavefront stability required for high-contrast imaging the cost of some throughput. In this paper, we present the simulated performance of the concentric ring shaped pupil concepts comparing them to focal-plane coronagraphs that are optimized for the same inner working angles.

extrasolar planets

The use of photographic methods in contrast enhancement of ERTS-1 images

The contrast of ERTS 70mm positive images can be enhanced to varying degrees by rephotographing the images with different types of negative films, and by overdeveloping the films with different developers. A combination of high contrast copy film (Kodak 5069) and a high energy developer (Kodak D-11) yields high contrast. Still greater contrast may be otbained by using a film of higher contrast capability and a developer of higher energy capability. Contrast can also be enhanced in the printing process with the use of highcontrast photographic papers, or with the use of polycontrast photographic paper and filters. Contrast enhancement by photocopying delineates topographic boundaries and may aid in the objective measurement of topographic parameters.

Harris, L. F.

Nonlinear Dynamics of Cantilever-Sample Interactions in Atomic Force Microscopy

The interaction of the cantilever tip of an atomic force microscope (AFM) with the sample surface is obtained by treating the cantilever and sample as independent systems coupled by a nonlinear force acting between the cantilever tip and a volume element of the sample surface. The volume element is subjected to a restoring force from the remainder of the sample that provides dynamical equilibrium for the combined systems. The model accounts for the positions on the cantilever of the cantilever tip, laser probe, and excitation force (if any) via a basis set of set of orthogonal functions that may be generalized to account for arbitrary cantilever shapes. The basis set is extended to include nonlinear cantilever modes. The model leads to a pair of coupled nonlinear differential equations that are solved analytically using a matrix iteration procedure. The effects of oscillatory excitation forces applied either to the cantilever or to the sample surface (or to both) are obtained from the solution set and applied to the to the assessment of phase and amplitude signals generated by various acoustic-atomic force microscope (A-AFM) modalities. The influence of bistable cantilever modes of on AFM signal generation is discussed. The effects on the cantilever-sample surface dynamics of subsurface features embedded in the sample that are perturbed by surface-generated oscillatory excitation forces and carried to the cantilever via wave propagation are accounted by the Bolef-Miller propagating wave model. Expressions pertaining to signal generation and image contrast in A-AFM are obtained and applied to amplitude modulation (intermittent contact) atomic force microscopy and resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM). The influence of phase accumulation in A-AFM on image contrast is discussed, as is the effect of hard contact and maximum nonlinearity regimes of A-AFM operation.

Cantrell, John H.

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass

Astronomical Near-neighbor Detection with a Four-quadrant Phase Mask (FQPM) Coronagraph

Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques, because of their very different respective fluxes. We thus investigated the innovative coronagraphic approach based on the use of a four-quadrant phase mask (FQPM). Simulations showed that, combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows high-contrast imaging very close to stars, with detection capability superior to that of a traditional coronagraph. A FQPM instrument was thus built to test the feasibility of near-neighbor observations with our new off-axis approach on a ground-based telescope. In June 2005, we deployed our instrument to the Palomar 200-inch telescope, using existing facilities as much as possible for rapid implementation. In these initial observations, using data processing techniques specific to FQPM coronagraphs, we reached extinction levels of the order of 200:1. Here we discuss our simulations and on-sky results obtained so far.

phase mask

Technologies to Enable the Next Great Observatory

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is one of four mission concepts being studied by NASA for the 2020 Decadal Survey in Astronomy and Astrophysics. LUVOIR will be capable of a broad range of science, including: direct imaging and characterization of a wide range of exoplanets and the search for biosignatures on Earth-like planets around sun-like stars; studying galaxy formation and evolution; investigating star and planet formation; and remote sensing of bodies within the Solar System. Enabling a mission as ambitious as LUVOIR requires an array of technologies, such as ultra-stable structures and optics, precision metrology and wavefront sensing, high-contrast imaging techniques, large-format detectors with very low noise, and high-throughput ultraviolet instrumentation. Critically, a systems-level approach must be taken to developing these technologies, guided by architecture studies to place each technology in the appropriate system context.In this poster, we describe LUVOIR's technology needs, as well as current efforts that are actively developing these technologies. We will discuss recent advancements in: measuring picometer-level displacements of optical and structural elements; sub-milli-kelvin thermal sensing and control; non-contact vibration isolation for pointing and dynamic stability; coronagraph design for achieving 10-10 contrast on a segmented system; high-speed metrology for optical system alignment; low-order and out-of-band wavefront sensing for maintaining high-contrast images; low-noise detectors across the ultraviolet, optical, and near infrared bands; broadband coatings with high-reflectivity below Ly. We will also describe a systems approach to coordinating the development of these technologies to achieve the necessary maturity for a LUVOIR mission start in the next decade.

space telescopes