Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead

Ion mobility spectrometry (IMS) is a rapid separation technique that has experienced exponential growth as a field of study. Interfacing IMS with mass spectrometry (IMS-MS) provides additional analytical power as complementary separations from each technique enable multidimensional characterization of detected analytes. IMS separations occur on a millisecond timescale, and therefore can be readily nested into traditional GC and LC/MS workflows. However, the continual development of novel IMS methods has generated some level of confusion regarding the advantages and disadvantages of each. In this critical insight, we aim to clarify some common misconceptions for new users in the community pertaining to the fundamental concepts of the various IMS instrumental platforms (i.e., DTIMS, TWIMS, TIMS, FAIMS, and DMA), while addressing the strengths and shortcomings associated with each. Common IMS-MS applications are also discussed in this review, such as separating isomeric species, performing signal filtering for MS, and incorporating collision cross-section (CCS) values into both targeted and untargeted omics-based workflows as additional ion descriptors for chemical annotation. Although many challenges must be addressed by the IMS community before mobility information is collected in a routine fashion, the future is bright with possibilities. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cytoprotective effect of imatinib mesylate in non-BCR-ABL-expressing cells along with autophagosome formation

Treatment with imatinib mesylate (IM) results in an increased viable cell number of non-BCR-ABL-expressing cell lines by inhibiting spontaneous apoptosis. Electron microscopy revealed an increase of autophagosomes in response to IM. IM attenuated the cytotoxic effect of cytosine arabinoside, as well as inhibiting cell death with serum-deprived culture. Cytoprotection with autophagosome formation by IM was observed in various leukemia and cancer cell lines as well as normal murine embryonic fibroblasts (MEFs). Complete inhibition of autophagy by knockdown of atg5 in the Tet-off atg5{sup -/-} MEF system attenuated the cytoprotective effect of IM, indicating that the effect is partially dependent on autophagy. However, cytoprotection by IM was not mediated through suppression of ROS production via mitophagy, ER stress via ribophagy, or proapoptotic function of ABL kinase. Although the target tyrosine kinase(s) of IM remains unclear, our data provide novel therapeutic possibilities of using IM for cytoprotection.

60 APPLIED LIFE SCIENCES↗

Dynamically Multiplexed Ion Mobility Time-of-Flight Mass Spectrometry

Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity high-throughput platform for e.g. proteomics applications. In this work, we have developed and integrated three advanced technologies, enabling (1) efficient ion accumulation in the ion funnel trap prior to IMS separation, (2) multiplexing (MP) of ion packet introduction into the IMS drift tube and (3) signal detection with an analog-to-digital converter (ADC), into the IMS-TOFMS system for the high-throughput analysis of highly complex proteolytic digests of e.g. blood plasma. To better address variable sample complexity, we have additionally developed and rigorously evaluated a new dynamic MP approach that ensures correlation of the analyzer performance with an ion source function, and provides the improved dynamic range and sensitivity. The MP IMS-TOF MS instrument has been shown to reliably detect peptides at a concentration of 1 nM in a highly complex matrix, as well as to provide a four orders of magnitude dynamic range and a mass measurement accuracy of better than 5 ppm. When matched against human blood plasma database, the detected IMS-TOF features yielded ~ 700 unique peptide identifications at a false discovery rate (FDR) of ~ 7.5 %. Accounting for IMS information gave rise to a projected FDR of ~ 4 %. Signal reproducibility was found to be greater than 80 %, while the variations in the number of unique peptide identifications were < 15 %. A single sample analysis was completed in 15 min, corresponding to approximately an order of magnitude improvement compared to a more conventional LC-MS approach.

Belov, Mikhail E.↗

Development of an E. coli strain for one-pot biofuel production from ionic liquid pretreated cellulose and switchgrass

Biological production of chemicals and fuels using microbial transformation of sustainable carbon sources, such as pretreated and saccharified plant biomass, is a multi-step process. Typically, each segment of the workflow is optimized separately, often generating conditions that may not be suitable for integration or consolidation with the upstream or downstream steps. While significant effort has gone into developing solutions to incompatibilities at discrete steps, very few studies report the consolidation of the multi-step workflow into a single pot reactor system. Here we demonstrate a one-pot biofuel production process that uses the ionic liquid 1-ethyl-3-methylimidazolium acetate (C 2 C 1 Im][OAc] ) for pretreatment of switchgrass biomass. [C 2 C 1 Im][OAc] is highly effective in deconstructing lignocellulose, but nonetheless leaves behind residual reagents that are toxic to standard saccharification enzymes and the microbial production host. We report the discovery of an [C 2 C 1 Im]-tolerant E. coli strain, where [C 2 C 1 Im] tolerance is bestowed by a P7Q mutation in the transcriptional regulator encoded by rcdA. We establish that the causal impact of this mutation is the derepression of a hitherto uncharacterized major facilitator family transporter, YbjJ. To develop the strain for a one-pot process we engineered this [C 2 C 1 Im]-tolerant strain to express a recently reported d-limonene production pathway. We also screened previously reported [C 2 C 1 Im]-tolerant cellulases to select one that would function with the range of E. coli cultivation conditions and expressed it in the [C 2 C 1 Im]-tolerant E. coli strain so as to secrete this [C 2 C 1 Im]-tolerant cellulase. The final strain digests pretreated biomass, and uses the liberated sugars to produce the bio-jet fuel candidate precursor d-limonene in a one-pot process.

09 BIOMASS FUELS↗

Vapor pressures of 1,3-dialkylimidazolium bis(trifluoromethylsulfonyl)imide ionic liquids with long alkyl chains

This work presents the vapor pressure at several temperatures for the 1,3-dialkylimidazolium bis(trifluoromethylsulfonyl)imide series, [C{sub N/2}C{sub N/2}im][NTf{sub 2}] (N = 14, 16, 18, and 20), measured by a Knudsen effusion method combined with a quartz crystal microbalance. The thermodynamic properties of vaporization of the ionic liquids under study are analysed together with the results obtained previously for the shorter alkyl chain length [C{sub N/2}C{sub N/2}im][NTf{sub 2}] (N = 2, 4, 6, 8, 10, and 12), in order to evaluate the effect of the alkyl side chains of the cation and to get additional insights concerning the nanostructuration of ionic liquids. The symmetry effect is explored, based on the comparison with the asymmetric imidazolium based ionic liquids, [C{sub N-1}C{sub 1}im][NTf{sub 2}]. A trend shift on the thermodynamic properties of vaporization along the alkyl side chains of the extended symmetric ionic liquids, around [C{sub 6}C{sub 6}im][NTf{sub 2}], was detected. An intensification of the odd-even effect was observed starting from [C{sub 6}C{sub 6}im][NTf{sub 2}], with higher enthalpies and entropies of vaporization for the odd numbered ionic liquids, [C{sub 7}C{sub 7}im][NTf{sub 2}] and [C{sub 9}C{sub 9}im][NTf{sub 2}]. Similar, but less pronounced, odd-even effect was found for the symmetric ionic liquids with lower alkyl side chains length, [C{sub N/2}C{sub N/2}im][NTf{sub 2}] (with N = 4, 6, 8, 10, and 12). This effect is related with the predominant orientation of the terminal methyl group of the alkyl chain to the imidazolium ring and their influence in the cation-anion interaction. The same Critical Alkyl length at the hexyl, (C{sub 6}C{sub 1}and C{sub 6}C{sub 6}) was found for both asymmetric and symmetric series indicating that the nanostructuration of the ionic liquids is related with alkyl chain length.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RNA polymerase II trapped on a molecular treadmill: Structural basis of persistent transcriptional arrest by a minor groove DNA binder

Elongating RNA polymerase II (Pol II) can be paused or arrested by a variety of obstacles. These obstacles include DNA lesions, DNA-binding proteins, and small molecules. Hairpin pyrrole-imidazole (Py-Im) polyamides bind to the minor groove of DNA in a sequence-specific manner and induce strong transcriptional arrest. Remarkably, this Py-Im–induced Pol II transcriptional arrest is persistent and cannot be rescued by transcription factor TFIIS. In contrast, TFIIS can effectively rescue the transcriptional arrest induced by a nucleosome barrier. The structural basis of Py-Im–induced transcriptional arrest and why TFIIS cannot rescue this arrest remain elusive. Here we determined the X-ray crystal structures of four distinct Pol II elongation complexes (Pol II ECs) in complex with hairpin Py-Im polyamides as well as of the hairpin Py-Im polyamides–dsDNA complex. We observed that the Py-Im oligomer directly interacts with RNA Pol II residues, introduces compression of the downstream DNA duplex, prevents Pol II forward translocation, and induces Pol II backtracking. These results, together with biochemical studies, provide structural insight into the molecular mechanism by which Py-Im blocks transcription. Our structural study reveals why TFIIS fails to promote Pol II bypass of Py-Im–induced transcriptional arrest.

59 BASIC BIOLOGICAL SCIENCES↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Laser‐ablation electrospray ionization mass spectrometry with ion mobility separation reveals metabolites in the symbiotic interactions of soybean roots and rhizobia

Summary Technologies enabling in situ metabolic profiling of living plant systems are invaluable for understanding physiological processes and could be used for rapid phenotypic screening (e.g., to produce plants with superior biological nitrogen‐fixing ability). The symbiotic interaction between legumes and nitrogen‐fixing soil bacteria results in a specialized plant organ (i.e., root nodule) where the exchange of nutrients between host and endosymbiont occurs. Laser‐ablation electrospray ionization mass spectrometry ( LAESI ‐ MS ) is a method that can be performed under ambient conditions requiring minimal sample preparation. Here, we employed LAESI ‐ MS to explore the well characterized symbiosis between soybean ( Glycine max L. Merr.) and its compatible symbiont, Bradyrhizobium japonicum . The utilization of ion mobility separation ( IMS ) improved the molecular coverage, selectivity, and identification of the detected biomolecules. Specifically, incorporation of IMS resulted in an increase of 153 differentially abundant spectral features in the nodule samples. The data presented demonstrate the advantages of using LAESI – IMS – MS for the rapid analysis of intact root nodules, uninfected root segments, and free‐living rhizobia. Untargeted pathway analysis revealed several metabolic processes within the nodule (e.g., zeatin, riboflavin, and purine synthesis). Compounds specific to the uninfected root and bacteria were also detected. Lastly, we performed depth profiling of intact nodules to reveal the location of metabolites to the cortex and inside the infected region, and lateral profiling of sectioned nodules confirmed these molecular distributions. Our results established the feasibility of LAESI – IMS – MS for the analysis and spatial mapping of plant tissues, with its specific demonstration to improve our understanding of the soybean‐rhizobial symbiosis.

Stopka, Sylwia A.↗

Non-Destructive Evaluation of Polyolefin Thermal Aging Using Infrared Spectroscopy

Fourier transform infrared (FTIR) spectroscopy is an information-rich method that reveals chemical bonding near the surface of polymer composites. FTIR can be used to verify composite composition, identify chemical contaminants and expose composite moisture content. Polymer matrix changes due to thermal exposure including loss of additives, chain scission, oxidation and changes in crystallinity may also be determined using FTIR spectra. Portable handheld instruments using non-contact reflectance or surface contact attenuated total reflectance (ATR) may be used for non-destructive evaluation (NDE) of thermal aging in polymer and composite materials of in-service components. We report the use of ATR FTIR to track oxidative thermal aging in ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE) materials used in medium voltage nuclear power plant electrical cable insulation and jacketing. Mechanical property changes of the EPR and CPE materials with thermal degradation for correlation with FTIR data are tracked using indenter modulus (IM) testing. IM is often used as a local NDE metric of cable jacket health. The FTIR-determined carbonyl index was found to increase with IM and may be a valuable NDE metric with advantages over IM for assessing cable remaining useful life.

aging↗

Associations between environmental quality and infant mortality in the United States, 2000–2005

Background: The United States (U.S.) suffers from high infant mortality (IM) rates and there are significant racial/ethnic differences in these rates. Prior studies on the environment and infant mortality are generally limited to singular exposures. We utilize the Environmental Quality Index (EQI), a measure of cumulative environmental exposure (across air, water, land, sociodemographic, and land domains) for U.S. counties from 2000 to 2005, to investigate associations between ambient environment and IM across maternal race/ethnicity. Methods: We linked 2000–2005 infant data from the U.S. Centers for Disease Control and Prevention to the EQI (n = 22,702,529; 144,741 deaths). We utilized multi-level regression to estimate associations between quartiles of county-level EQI and IM. We also considered associations between quartiles of county level domain specific indices with IM. We controlled for rural-urban status (RUCC1: urban, metropolitan; RUCC2: urban, non-metropolitan; RUCC3: less urbanized; RUCC4: thinly populated), maternal age, maternal education, marital status, infant sex, and stratified on race/ethnicity. Additionally, we estimated associations for linear combinations of environmental quality and rural-urban status. Results: We found a mix of positive, negative, and null associations and our findings varied across domain and race/ethnicity. Poorer overall environmental quality was associated with decreased odds among Non-Hispanic whites (OR and 95% CI: EQIQ4 (ref. EQIQ1): 0.84[0.80,0.89]). For Non-Hispanic blacks and Hispanics, some increased odds were observed. Poorer air quality was monotonically associated with increased odds among Non-Hispanic whites (airQ4 (ref. airQ1): 1.05[0.99,1.11]) and blacks (airQ4 (ref. airQ1): 1.09 [0.9,1.31]). Rural status was associated with increased IM odds among Hispanics (RUCC4-Q4:1.36[1.04,1.78]; RUCC1-Q4: 1.04[0.92,1.16], ref. for both RUCC1-Q1). Conclusions: This study is the first to report on associations between ambient environmental quality and IM across the United States. It corroborates prior research suggesting an association between air pollution and IM and identifies residence in thinly populated (rural) areas as a potential risk factor towards IM amongst Hispanics. Some of the counterintuitive findings highlight the need for additional research into potentially differential drivers of environmental quality across the rural-urban continuum, especially with regards to the sociodemographic environment.

60 APPLIED LIFE SCIENCES↗

Issues Management Process Course # 38401

The purpose of this training it to advise Issues Management Coordinators (IMCs) on the revised Contractor Assurance System (CAS) Issues Management (IM) process. Terminal Objectives: Understand the Laboratory’s IM process; Understand your role in the Laboratory’s IM process. Learning Objectives: Describe the IM process within the context of the CAS; Describe the importance of implementing an institutional IM process at LANL; Describe the process flow for the Laboratory’s IM process; Apply the definition of an issue; Use available resources to determine initial screening risk levels for issues; Describe the required major process steps for each risk level; Describe the personnel responsibilities for IM process implementation; Access available resources to support IM process implementation.

99 GENERAL AND MISCELLANEOUS↗

Image-based modeling of coupled electro-chemo-mechanical behavior of Li-ion battery cathode using an interface-modified reproducing kernel particle method

Abstract An interface-modified reproducing kernel particle method (IM-RKPM) is introduced in this work to allow for a direct model construction from image pixels of heterogeneous polycrystalline Li-ion battery microstructures. The interface-modified reproducing kernel (IM-RK) approximation is constructed through scaling of a kernel function by a regularized distance function in conjunction with strategic placement of interface node locations. This leads to RK shape functions with either weak or strong discontinuities across material interfaces, suitable for modeling various interface mechanics. With the placement of a triple junction node and distance-based scaling of kernel functions, the resulting IM-RK shape function also possesses proper discontinuities at the triple junctions. This IM-RK approximation effectively remedies the well-known Gibb’s oscillation in the smooth approximation of discontinuities. Different from the conventional meshfree approaches for interface discontinuities, this IM-RK approach is done without additional degrees of freedom associated with the enrichment functions, and it is formulated with the standard procedures in the RK shape function construction. This work focuses on identifying the accuracy and convergence properties of IM-RKPM for modeling the coupled electro-chemo-mechanical system. A linear patch test is formulated and numerically tested for the electro-chemo-mechanical coupled problem with a Butler–Volmer boundary condition representing the physical conditions in Li-ion battery microstructures. This is followed by verification of the optimal rates of convergence of IM-RKPM for solving the coupled problem with higher order solutions. The image-based modeling of Li-ion battery microstructures in the numerical examples demonstrates the applicability of the proposed method to realistic Li-ion battery materials modeling.

25 ENERGY STORAGE↗

Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave

Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing

In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Editorial overview: Omics

The great complexity of biological systems and their environment poses similarly vast challenges for accurate analytical evaluations of their identity, structure and quantity. Post genomic science, has predicted much regarding the static populations of biological systems, but a further challenge for analysis is to test the accuracy of these predictions, as well as provide a better representation of the transient nature of the molecules of life. Accurate measurements of biological systems have wide applications for biological, forensic, biotechnological and healthcare fields. Therefore, the holy grail is to find a technique which can identify and quantify biological molecules with high throughput, sensitivity and robustness, as well evaluate molecular structure(s) in order to understand how the specific molecules interact and function. While wrapping all of these characteristics into one platform may sound difficult, ion mobility spectrometry (IMS) is addressing all of these challenges. Over the last decade, the number of analytical studies utilizing IMS for the evaluation of complex biological and environmental samples has greatly increased. In most cases IMS is coupled with mass spectrometry (IM-MS), but even alone IMS provides the unique capability of rapidly assessing a molecule’s structure, which can be extremely difficult with other techniques. The robustness of the IMS measurement is bourne out by its widespread use in security, environmental and military applications. The multidimensional IM-MS measurements however have been proven to be ever more powerful, as applied to complex mixtures as they enable the evaluation of both the structure and mass of every molecular component in a sample during a single measurement, without the need for continual reference calibration.

Barran, Perdita↗

Growth kinetics of Al–Fe intermetallic compounds during annealing treatment of friction stir lap welds

In this study, we explored the growth kinetics of the Al–Fe intermetallic (IM) layer at the joint interface of the St-12/Al-5083 friction stir lap welds during post-weld annealing treatment at 350, 400 and 450 °C for 30 to 180 min. Optical microscope (OM), field emission gun scanning electron microscope (FEG-SEM) and transmission electron microscope (TEM) were employed to investigate the structure of the weld zone. The thickness and composition of the IM layers were evaluated using image analysis system and electron back-scatter diffraction (EBSD), respectively. Moreover, kernel average misorientation (KAM) analysis was performed to evaluate the level of stored energy in the as-welded state. The results showed that the growth kinetics of the IM layer was not governed by a parabolic diffusion law. Presence of the IM compounds as well as high stored energy near the joint interface of the as-welded sample was recognized to be the origin of the observed deviation from the parabolic diffusion law. - Highlights: • This work provided a new insight into growth kinetics of Al–Fe IM thickness. • The growth kinetics of IM layer was not governed by a parabolic diffusion law. • IM near the joint interface was the origin of deviation from the parabolic law. • High stored energy at joint interface was origin of deviation from parabolic law.

36 MATERIALS SCIENCE↗

Ion mobility spectrometry and the omics: Distinguishing isomers, molecular classes and contaminant ions in complex samples

Ion mobility spectrometry (IMS) is a widely used analytical technique providing rapid gas phase separations. IMS alone is useful, but its coupling with mass spectrometry (IMS-MS) and various front-end separation techniques has greatly increased the molecular information achievable from omic analyses, including the sensitivity and peak capacity extracted from complex biological and environmental sample analyses. Due to these characteristics, IMS-MS is rapidly gaining attention for improving metabolomic, lipidomic, glycomic, proteomic and exposomic analyses. Numerous studies including national security-related analyses, disease screenings and environmental evaluations are illustrating that IMS-MS is able to extract information not possible with MS alone. Furthermore, IMS-MS has shown great utility in salvaging molecular information for low abundance molecules of interest when high concentration contaminant ions are present in the sample. This review highlights how IMS-MS is currently being used in omic analyses to distinguish structurally similar molecules, isomers, molecular classes and contaminant ions.

Ion mobility spectrometry,, Mass Spectometry, Omic↗

Improved Sensitivity and Separations for Phosphopeptides using Online Liquid Chromotography Coupled with Structures for Lossless Ion Manipulations Ion Mobility–Mass Spectrometry

Phosphoproteomics greatly augments proteomics and holds tremendous potential for insights into the modulation of biological systems for various disease states, etc. However, numerous challenges hinder conventional methods in terms of measurement sensitivity, throughput, and capabilities for confident phosphopeptide and phosphosite identification. In this work, we report the first example of integrating structures for lossless ion manipulations ion mobility (SLIM) IM-MS with online reversed-phase liquid chromatography (LC) to evaluate its potential for addressing the aforementioned challenges. A mixture of 51 heavy-labeled phosphopeptides was analyzed with a SLIM IM module having integrated ion accumulation and long-path separation regions. The SLIM IM-MS provided improved sensitivity over an established LC-SRM method, with limits of detection as low as 50 pM (50 amol/µl) for several peptides. Conventionally problematic phosphopeptide isomers could be resolved following an 18 m SLIM IM separation. The 2-D peak capacity was estimated as ~9000 for 90 min LC separation coupled to an 18 m SLIM IM separation, considerably higher than LC alone and providing a basis for both improved identification and quantification, with additional gains projected with the future use of longer path SLIM IM separations. Thus, LC-SLIM IM-MS offers great potential for improving the sensitivity, separation, and throughput of phosphoproteomics analyses.

Chouinard, Christopher D.↗