Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Elemental profiling and genome-wide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

The ionome represents elemental composition in plant tissues and can be an indicator of nutrient status as well as overall plant performance. Thus, identifying genetic determinants governing elemental uptake and storage is an important goal for breeding and engineering biomass feedstocks with improved performance. In this study, we coupled high-throughput ionome characterization of leaf tissues with high-resolution genome-wide association studies (GWAS) to uncover genetic loci that modulate ionomic composition in leaves of poplar ( Populus trichocarpa ). Significant agreement was observed across the three ionomic profiling platforms tested: inductively coupled plasma-mass spectrometry (ICP-MS), neutron activation analysis (NAA) and laser-induced breakdown spectroscopy (LIBS). Relative quantification of 20 elements using ICP-MS across a population of 584 genotypes, revealed larger variation in micro-nutrients and trace elements content than for macro-nutrients across genotypes. The GWAS performed using a set of high-density (>8.2 million) single nucleotide polymorphisms, identified over 600 loci significantly associated with variations in these mineral elements, pointing to numerous uncharacterized candidate genes. A significant enrichment for genes related to ion homeostasis and transport was observed, including several members of the cation-proton antiporters (CPA) family and MATE efflux transporters, previously reported to be critical for plant growth and fitness in other species. Our results also included a polymorphic copy of the high-affinity molybdenum transporter MOT1 found directly associated to molybdenum content. For the first time in a perennial plant, our results provide evidence of genetic control of mineral content in a model tree species.

59 BASIC BIOLOGICAL SCIENCES↗

Sequential removal of cation/H + exchangers reveals their additive role in elemental distribution, calcium depletion and anoxia tolerance

Multiple Arabidopsis H + /Cation exchangers (CAXs) participate in high-capacity transport into the vacuole. Previous studies have analysed single and double mutants that marginally reduced transport; however, assessing phenotypes caused by transport loss has proven enigmatic. Here, in this study, we generated quadruple mutants (cax1-4: qKO) that exhibited growth inhibition, an 85% reduction in tonoplast-localised H + /Ca transport, and enhanced tolerance to anoxic conditions compared to CAX1 mutants. Leveraging inductively coupled plasma mass spectrometry (ICP-MS) and synchrotron X-ray fluorescence (SXRF), we demonstrate CAX transporters work together to regulate leaf elemental content: ICP-MS analysis showed that the elemental concentrations in leaves strongly correlated with the number of CAX mutations; SXRF imaging showed changes in element partitioning not present in single CAX mutants and qKO had a 40% reduction in calcium (Ca) abundance. Reduced endogenous Ca may promote anoxia tolerance; wild-type plants grown in Ca-limited conditions were anoxia tolerant. Sequential reduction of CAXs increased mRNA expression and protein abundance changes associated with reactive oxygen species and stress signalling pathways. Multiple CAXs participate in postanoxia recovery as their concerted removal heightened changes in postanoxia Ca signalling. This work showcases the integrated and diverse function of H + /Cation transporters and demonstrates the ability to improve anoxia tolerance through diminishing endogenous Ca levels.

36 MATERIALS SCIENCE↗

Trace Element Analyses of Micron-Size Particles and Statistical Determination of Minimum Detection Limits

Savannah River National Laboratory (SRNL) has developed expertise in producing homogeneous, ca. 1 m-diameter spherical particles of mixed-element components, wherein dopants can be varied from a trace constituent (ppm) to wt.% concentrations. The samples used for this work are nickel-doped cerium oxide microspheres produced by SRNL. They were initially selected as analogs for plutonium-doped uranium oxide particles and analyzed as part of a larger study to evaluate whether electron probe microanalyzers (EPMA) can be used to characterize nuclear materials as an alternative or complementary method to mass spectrometers. The five samples used in this study contained nominal compositions of 0, 0.004, 0.04, 0.4 and 4 wt.% Ni. They were analyzed by both an Agilent 7900 Q-ICP-MS at SRNL and the JEOL JXA8530F Plus EPMA at the University of Minnesota. In addition to EPMA results (calibrated with high-precision Q-ICP-MS analyses) suggesting that the EPMA could address outstanding nuclear material characterization needs, these samples 1) showcase the ability of the EPMA to quantify not just trace concentrations, but trace concentrations in microparticles (1 m diameter, Fig. 1), and 2) offer a unique opportunity to evaluate the methodology for assessing the minimum detection limits of EPMA analyses.

McSwiggen, Peter [JEOL USA, 11 Dearborn Road, Peab↗

Uncovering Uranium Isotopic Heterogeneity of Fuel Pellets from the Fifth Collaborative Materials Exercise of the Nuclear Forensics International Technical Working Group

In 2017, the Nuclear Forensics International Technical Working Group (ITWG) organized their fifth 37 Collaborative Materials Exercise (CMX-5). The exercise samples were two uranium dioxide fuel pellets 38 manufactured from the same starting materials by different processes to have similar bulk isotopic 39 composition, but different spatial uranium isotopic distributions. Sets of identical materials were sent to 40 all participating laboratories, who then utilized their existing nuclear forensic capabilities to 41 independently analyse fuel pellets and identify similarities and differences of the materials’ 42 characteristics. The analytical methods used to probe the fuel pellets included ex situ, such as sectioning 43 or breaking up the pellets and analyzing dissolved pieces using inductively coupled plasma mass 44 spectrometry (ICP-MS), analyzing particles collected from intact or fragmented pellets by secondary ion 45 mass spectrometry (SIMS), as well as in situ methods, such as laser ablation coupled with ICP-MS, 46 autoradiography and nanoSIMS. In this paper we present the results of these independent analyses and 47 compare the capabilities of those nuclear forensic analytical methods to uncover details of the isotopic 48 heterogeneity of uranium fuel pellets.

Nuclear Forensic Analysis of Uranium Fuel Pellets,↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Mathematical Modeling of the Potential and Time Dependence of Ir Dissolution from Hydrous Ir Oxide Oxygen Evolution Catalysts

One of the main degradation mechanisms of hydrous iridium oxide acidic oxygen evolution reaction (OER) catalysts is dissolution and loss into the acidic membrane. While degradation models have been proposed, there is a gap in understanding the potential and time dependence of the iridium dissolution reaction and its mechanistic underpinnings. In this work, Ir dissolution rates measured as a function of time and potential via time-resolved inductively-coupled plasma mass spectrometry (ICP-MS) in aqueous acidic electrolyte are used to establish a mathematical model for Ir dissolution. The mathematical model is generated using proposed formation and dissolution reactions for Ir species. Through comparison with the ICP-MS data and existing information on the potential-dependent Ir phase, we find that the potential and time-dependence of dissolution can be modeled as dissolution of an oxide phase, here represented as IrO 2 , with potential dependent kinetics and formation of a passivating species, a process with a rate-limiting step that is not potential dependent. This understanding of the potential dependence of dissolution and passivation kinetics using aqueous electrolyte half-cell measurements can be used to predict the degradation of Ir oxide in operating energy conversion devices relying on the OER, such as proton-exchange membrane water electrolyzers.

Kariuki, Nancy N. [Argonne National Laboratory (AN↗

Rare earth ion-adsorption clays in the presence of iron at basic pH: Adsorption mechanism and extraction method

In this work, the uptake mechanism and influence of iron (Fe) co-adsorption on the binding of rare-earth elements (REEs) on kaolinite have been investigated. REEs and varying concentrations of Fe were co-adsorbed onto kaolinite at pH 10.5. Inductively coupled plasma mass spectrometry (ICP-MS), powder X-ray diffraction (PXRD), and X-ray photoelectron spectroscopy (XPS) were used to characterize how Fe co-adsorption influenced the uptake mechanism of REEs on kaolinite. Elemental analysis by ICP-MS revealed that the REE concentrations on kaolinite were unaffected by the presence of Fe. Crystal structure of kaolinite, determined by PXRD, was not altered after REE and Fe co-adsorption. XPS suggests that the adsorbed Fe is in the form of FeOOH, while the greatly attenuated REE XPS signals upon Fe co-adsorption implies that REEs are encapsulated by Fe species. Based on these results, we conclude that FeOOH layers were formed on top of REEs on the surface of kaolinite. Synthesized REE-Fe-kaolinite samples respond poorly to ion-exchange leaching, indicating that Fe is detrimental to the REE ion-exchange efficiency. The inhibition of ion-exchange REE extraction appears to be due to the passivating FeOOH layers. In contrast to ion-exchange methods, reductive leaching was found to dissolve the FeOOH passivating layers and liberate REEs such that they became available for ion-exchange leaching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

R-Value Measurements Performed on Actinide Targets Irradiated using the GODIVA IV Critical Assembly in FY22

The separation and characterization of two irradiated uranium targets, a depleted uranium (DU) and a highly enriched uranium (HEU) target as well as a plutonium (Pu) target, was conducted in April of 2022. The three targets were assembled at Los Alamos National Laboratory (LANL) and irradiated using the GODIVA critical assembly at the National Criticality Experiments Research Center (NCERC). Splits of the dissolved targets were received by Pacific Northwest National Laboratory (PNNL) after which the PNNL and LANL teams chemically separated the solutions using independent separation schemes and analyzed the separated fractions for short lived actinides and fission products. Chemical separations were traced with stable or radioactive tracers to allow for the determination of chemical yields, analyzing using either inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) or gamma emission analysis (GEA) depending on the nature of the tracer. The Pu target solution was traced with stable elements at LANL to follow elemental fractionation during a Pu removal step. Many analytical techniques were used by PNNL including kinetic phosphorescence analysis (KPA), ICP-OES, ICP-MS, GEA, and thermal ionization mass spectrometry (TIMS) depending on the analyte’s need.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A study of rare earth ion-adsorption clays: The speciation of rare earth elements on kaolinite at basic pH

Synthesized rare earth ion-adsorption clays (La, Ce, Nd, Dy and Y, ~ 400 ppm each) were prepared from kaolinite at various basic pH in open-air conditions. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and inductively coupled plasma mass spectrometry (ICP-MS) were used to characterize the effect of pH on the adsorption mechanism of rare earth elements (REEs) on kaolinite. The crystal structure of kaolinite by XRD analysis is not altered after REE adsorption, suggesting that REEs are bound to the surface of kaolinite. Elemental analysis by XPS and ICP-MS show that the surface concentration of REEs on kaolinite is pH dependent, and a local maximum of the surface concentration is achieved at pH 10. Three characteristics of the La 3d 5/2 XPS photoemission feature were measured and compared to those of standard La compounds to probe the speciation of REEs, and electrostatically bound hydroxides such as REE(OH) 2 + are identified as the primary species on the surface of kaolinite. Finally, compared to the typical ion-adsorption clays with intrinsic acidic pH, clays synthesized at basic pH exhibit similarly high rare earth ion-exchange efficiency with ammonium sulfate (AS), suggesting that rare earth ion-adsorption clays can exist in both acidic and basic environments.

36 MATERIALS SCIENCE↗

Activation of CO 2 by Actinide Cations (Th + , U + , Pu + , and Am + ) as Studied by Guided Ion Beam and Triple Quadrupole Mass Spectrometry

Reactions of CO 2 with Th+ have been studied using guided ion beam tandem mass spectrometry (GIBMS) and with An + (An + = Th + , U + , Pu + , and Am + ) using triple quadrupole inductively coupled plasma mass spectrometry (QQQ-ICP-MS). Additionally, the reactions ThO + + CO and ThO + + CO 2 were examined using GIBMS. Modeling the kinetic energy dependent GIBMS data allowed determination of bond dissociation energies (BDEs) for D o (Th + -O) and D o (OTh + -O) that are in reasonable agreement with previous GIBMS measurements. The QQQ-ICP-MS reactions were studied at higher pressures where multiple collisions between An + and the neutral CO 2 occur. As a consequence, both AnO + and AnO 2 + products were observed for all An + except Am + , where only AmO + was observed. Here, the relative abundances of the observed monoxides compared to the dioxides are consistent with previous reports of the AnO n + (n = 1, 2) BDEs. Comparison of the periodic trends of the group 4 transition metal, lanthanide (Ln), and actinide atomic cations in reactions with CO 2 (a formally spin-forbidden reaction for most M + ground states), and O 2 (a spin unrestricted reaction) indicate that spin conservation plays a minor role, if any, for the heavier An + metals. Further correlation of Ln + and An + + CO 2 reaction efficiencies with the promotion energy (E p ) to the first electronic state with two valence d-electrons (E p (5d 2 ) for Ln + and E p (6d 2 ) for An + ) indicates that the primary limitation in the activation of CO 2 is the energetic cost to promote from the electronic ground state of the atomic metal ion to a reactive state.

bond activation↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

Corrosion Compatibility of Stainless Steels and Nickel in Pyrolysis Biomass-Derived Oil at Elevated Storage Temperatures

Corrosion compatibility of stainless steels and nickel (Ni200) was assessed in fast pyrolysis bio-oil produced from pyrolysis of high ash and high moisture forest residue biomass. Sample mass change, ICP-MS and post-exposure electron microscopy characterization was used to investigate the extent of corrosion. Among the tested samples, type 430F and type 316 stainless steels (SS430F and SS316) and Ni200 (~98.5% Ni) showed minimal mass changes (less than 2 mg∙cm−2) after the bio-oil exposures at 50 and 80 °C for up to 168 h. SS304 was also considered to be compatible in the bio-oil due to its relatively low mass change (1.6 mg∙cm−2 or lower). SS410 samples showed greater mass loss values even after exposures at a relatively low temperature of 35 °C. Fe/Cr values from ICP-MS data implied that Cr enrichment in stainless steels would result in a protective oxide layer associated with corrosion resistance against the bio-oil. Post exposure characterization showed continuous and uniform Cr distribution in the surface oxide layer of SS430F, which showed a minimal mass change, but no oxide layer on a SS430 sample, which exhibited a significant mass loss.

09 BIOMASS FUELS↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Selenium tolerance, accumulation, localization and speciation in a Cardamine hyperaccumulator and a non-hyperaccumulator

Cardamine violifolia (family Brassicaceae ) is the first discovered selenium hyperaccumulator from the genus Cardamine with unique properties in terms of selenium accumulation, i.e., high abundance of selenolanthionine. In our study, a fully comprehensive experiment was conducted with the comparison of a non-hyperaccumulator Cardamine species, Cardamine pratensis , covering growth characteristics, chlorophyll fluorescence, spatial selenium/sulfur distribution patterns through elemental analyses (synchrotron-based X-Ray Fluorescence and ICP-OES) and speciation data through selenium K-edge micro X-ray absorption near-edge structure analysis (μXANES) and strong cation exchange (SCX)-ICP-MS. The results revealed remarkable differences in contrast to other selenium hyperaccumulators as neither Cardamine pecies showed evidence of growth stimulation by selenium. Also, selenite uptake was not inhibited by phosphate for either of the Cardamine species. Sulfate inhibited selenate uptake, but the two Cardamine species did not show any difference in this respect. However, μXRF derived speciation maps and selenium/sulfur uptake characteristics provided results that are similar to other formerly reported hyperaccumulator and non-hyperaccumulator Brassicaceae species. μXANES showed organic selenium, “C-Se-C”, in seedlings of both species and also in mature C. violifolia plants. In contrast, selenate-supplied mature C. pratensis contained approximately half “C-Se-C” and half selenate. SCX-ICP-MS data showed evidence of the lack of selenocystine in any of the Cardamine plant extracts. Thus, C. violifolia shows clear selenium-related physiological and biochemical differences compared to C. pratensis and other selenium hyperaccumulators.

Environmental Sciences & Ecology↗