Acquisition of a High-resolution Inductively Coupled Plasma Mass Spectrometer for Cosmochemical and Geochemical Research

The primary goal of our research in this program is to develop new techniques for the analysis of volatile trace elements in very small samples using inductively coupled plasma mass spectrometry (ICP-MS) in preparation for samples returned by the Stardust mission. The instrument that will serve as the basis of our experiments is the ELEMENT2 high-resolution ICP-MS. We have spent the past year designing the laboratory to house this instrument as well as space to store and prepare samples returned by the Stardust mission. Unfortunately, the location that we had initially selected for the instrument turned out to be insufficient for our needs. This was determined almost eight months into the first year of our funding cycle, after extensive work including the production of engineering drawings. However, during this time the Lunar and Planetary Laboratory was selected to lead Phoenix, the first Mars Scout mission. As a result of this award LPL purchased a new, 50,000 square foot building. We have acquired 1400 square feet of laboratory space in this new facility. Four-hundred square feet will be used for a class-100 clean room. This area is designated for storage and preparation of extraterrestrial materials. The additional 1000 square feet will house the ELEMENT2 ICP-MS and peripheral devices. This is an enormous amount of space for this instrument, but it provides plenty of room for expansion in the future. The ICP-MS and the clean room facilities have been purchased. The instrument has been delivered. The startup time for this instrument is relatively short and we expect to be collecting our first data by mid-summer.

Lauretta, D. S.↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗

Fast Determination of Lithium Content in Spent Cathodes for Direct Battery Recycling

Determination of the lithium ion content in cathode materials, which is currently performed by inductively coupled plasma mass spectrometry (ICP-MS), involves tedious procedures and error-prone preparation. This work introduces a new methodology to quickly determine the lithium content in spent cathode materials (LiNix Mny Coz O2, x + y + z = 1, NMC) using a thermalgravimetric analysis, which bypasses the use of ICP-MS and significantly reduces the cost and time required for determining the lithium content. Based on this new method, a new approach is developed to identify spent cathode materials suitable for direct relithiation recycling. Finally, these new methods have been applied to investigate the effectiveness of direct electrochemical-relithiation on recycling the spent cathodes, and provide insights for future development of direct battery materials recycling.

cathode recycling↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Insights into Electrochemical Pre‐Treatments of Supported Nanoparticle Electrocatalysts by Combining a Design of Experiments Strategy with In Situ Characterization

Activation, break-in, and/or pre-treatment protocols are generally applied to energy conversion devices before regular operation to reach stable performance. There remains much to understand about the relationships among physical properties, performance, and electrochemical pre-treatments. Here, a design-of-experiments (DoE) strategy is employed to address this gap by demonstrating the influence of five pre-treatment parameters for carbon-supported Pt-nanoparticle catalysts on the electrocatalytic oxygen reduction reaction (ORR). A subset of pre-treatments, developed using a central composite design, are tested in a flow cell combined with an inductively-coupled plasma mass spectrometer (on-line ICP-MS). The DoE-based approach facilitates comprehensive insights from two orders of magnitude fewer experiments than a conventional grid search. The coupled on-line ICP-MS setup enables effective catalysis and real-time catalyst dissolution data. Leveraging insights from DoE for on-line ICP-MS and additional characterization, a model is built between the degradation of a multi-dimensional supported Pt surface, its performance, and applied electrochemical parameters. These investigations identify surface modifications, such as oxidation, and subsequent restructuring of Pt during pre-treatment as a primary cause of performance deterioration during ORR. By combining DoE with advanced characterization techniques, a powerful approach is demonstrated to gain a mechanistic understanding of pre-treatment protocols that can be broadly adapted to various reaction chemistries.

Platinum↗

The influence of water, diet, and temperature on 87 Sr/ 86 Sr in fin spines of juvenile Atlantic Sturgeon Acipenser oxyrinchus oxyrinchus

Analysis of microchemistry in fish fin spines offers a non-lethal approach to address key questions relating to spatial patterns and habitat use of fish. Reconstruction of life history is based on chemical changes within calcified structures with an underlying assumption of elemental incorporation relative to environmental concentration. However, information is limited on the relative influence of water and diet concentrations of elements to corresponding concentrations within fin spines. Strontium (Sr) is commonly used in trace element studies because of its predictable changes within watersheds, with recent applications showing utility of 87 Sr/ 86 Sr for greater spatial resolution. Therefore, this study evaluated the influence of water and diet 87 Sr/ 86 Sr on pectoral fin spines of Atlantic Sturgeon A. oxyrinchus oxyrinchus in controlled laboratory experiments. In the first experiment, fish were exposed to a control, water spiked with 0.10 mg/L of 87 Sr or diet spiked with 0.25 µg/g or 0.50 µg/g of 87 Sr in replicated tanks for 12 weeks. In a second experiment, to determine the time duration required to occupy a different environment for fin spine chemistry to change, fish were maintained in water- or diet-spiked treatments for 1, 2, 3, or 6 weeks. Additionally, to determine if temperature has an influence on 87 Sr/ 86 Sr in fin spines, fish were held at 15 and 25°C for 12 weeks. Fin spines were analyzed using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS), and water and diet samples were analyzed using solution based ICP-MS. Results from Experiment 1 indicate water is the primary contributor and diet a secondary contributor of 87 Sr/ 86 Sr in pectoral fin spines of Atlantic Sturgeon. Results from Experiment 2 indicate fin spine 87 Sr/ 86 Sr can be influenced by water after 1 week and diet after 12 weeks. Additionally, although sample size was limited (n=3), water temperature did not have an effect on 87 Sr/ 86 Sr fin spine chemistry. In conclusion, these results provide guidance for interpretation of 87 Sr/ 86 Sr in pectoral fin spines of sturgeon and indicate usefulness of the technique for retrospectively estimating movement and habitat use.

59 BASIC BIOLOGICAL SCIENCES↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plutonium Co-precipitation with Calcite

The mobility of plutonium (Pu) in the environment is affected by Pu–mineral interactions, such as adsorption–desorption and structural incorporation. Calcite (CaCO 3 ) is a common secondary phase in near surface environments and a major component of many rocks and soils and is expected to form as an alteration product of cement-based materials planned for use in geological repositories. The reactivity of the calcite surface and its ability to tolerate significant variations in its chemical composition through substitution of Ca for other cations make calcite a potentially important sink for environmental contaminants. Here, single crystals of calcite were synthesized from aqueous solutions in equilibrium with air containing Pu as either Pu(VI) or Pu(IV) and characterized using a combination of laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) and X-ray absorption spectroscopy (XAS). These data are used to assess the amount, structure, and oxidation state of Pu co-precipitated into calcite, providing insight into the potential for Pu sequestration in calcite precipitates. Overall, the XAS and LA–ICP–MS data support the co-precipitation of plutonyl [Pu(VI/V)] in the bulk calcite, although the exact nature of the co-precipitated Pu complex is difficult to elucidate in the synthesized material. Co-precipitated plutonyl could be incorporated in either distorted Ca lattice sites or defect sites, and we provide evidence to suggest that Pu(VI) is reduced mainly to Pu(V) in the precipitated solid. LA–ICP–MS additionally shows that the co-precipitation of Pu(VI/V) is favored over the co-precipitation of Pu(IV). Altogether, our results suggest that Pu sequestration in calcite under environmental conditions could immobilize Pu and isolate it from groundwater interactions in contaminated environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Mercury Abundances and Isotopic Compositions in the Murchison (CM) and Allende (CV)Carbonaceous Chondrites

The abundance and isotopic composition of Hg was determined in bulk samples of both the Murchison (CM) and Allende (CV) carbonaceous chondrites using single- and multi-collector inductively coupled plasma mass spectrometry (ICP-MS). The bulk abundances of Hg are 294 6 15 ng/g in Murchison and 30.0 6 1.5 ng/g in Allende. These values are within the range of previous measurements of bulk Hg abundances by neutron activation analysis (NAA). Prior studies suggested that both meteorites contain isotopically anomalous Hg, with d l 96/202Hg values for the anomalous, thermal-release components from bulk samples ranging from 2260 %o to 1440 9/00 in Murchison and from 2620 9/00 to 1540 9/00 in Allende (Jovanovic and Reed, 1976a; 1976b; Kumar and Goel, 1992). Our multi-collector ICP-MS measurements suggest that the relative abundances of all seven stable Hg isotopes in both meteorites are identical to terrestrial values within 0.2 to 0.5 9/00m. On-line thermal-release experiments were performed by coupling a programmable oven with the singlecollector ICP-MS. Powdered aliquots of each meteorite were linearly heated from room temperature to 900 C over twenty-five minutes under an Ar atmosphere to measure the isotopic composition of Hg released fiom the meteorites as a h c t i o n of temperature. In separate experiments, the release profiles of S and Se were determined simultaneously with Hg to constrain the Hg distribution within the meteorites and to evaluate the possibility of Se interferences in previous NAA studies. The Hg-release patterns differ between Allende and Murchison. The Hg-release profile for Allende contains two distinct peaks, at 225" and 343"C, whereas the profile for Murchison has only one peak, at 344 C. No isotopically anomalous Hg was detected in the thermal-release experiments at a precision level of 5 to 30 9/00, depending on the isotope ratio. In both meteorites the Hg peak at ;340"C correlates with a peak in the S-release profile. This correlation suggests that Hg is associated with S-bearing phases and, thus, that HgS is a major Hg-bearing phase in both meteorites. The Hg peak at 225 C for Allende is similar to release patterns of physically adsorbed Hg on silicate and metal grains.

Lauretta, D. S.↗

Fused Bead Analysis of Diogenite Meteorites

Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from ~10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

Mittlefehldt, D.W.↗

Thermodynamic constraints on the textural evolution of eucrite, EET 90020

Basaltic eucrites, which are possibly parts of the Vestan crust, formed as either lava flows or intrusions, and can offer insights into early crust formation. However most eucrites have experienced thermal metamorphism, which exacerbates the challenges of understanding these samples. A variety of petrogenetic models such as, partial melting of a primitive source, fractional crystallization of magmas emplaced in a primitive crust, and/or partial melting of a eucritic source coupled with melt mixing and assimilation have been proposed in order to explain observed petrologic and chemical characteristics of eucrites. EET 90020 is an unbrecciated eucrite that has experienced significant thermal metamorphism, with temperatures of metamorphic equilibration calculated to be ~840-1040°C. Its petrologic history remains contentious, in part due to differences in trace element analyses [10,17, this work], which has led to multiple metamorphic interpretations [8,10-11]. Here, we combined petrologic observations, chemical analyses, and thermodynamic modeling, to interpret micro-domain textures identified in EET 90020 and better constrain its petrologic history. Ultimately, the development of such textures is a direct result of the geologic processes operating on a young Vesta or similar asteroid. Sample description: We identified three textural domains in EET 90020 (Figure 1); (I) A coarse grain domain with granoblastic plagioclase and pyroxene, (II) a medium grain domain with curved grain boundaries between plagioclase and pyroxene, and (III) a fine grain domain dominated by tridymite that fills in interstitial space between spherical plagioclase. Major element chemistry in phases is consistent across domains. Pyroxene have distinctive high Ca lamellae (Wo40.92En28.1Fs31.0) forming from the low-Ca pigeonite host (Wo3.5En33.7Fs62.8). There are small amounts of fayalitic olivine along pyroxene/oxide grain boundaries, where pyroxenes have reacted with ilmenite/chromite clasts. Plagioclase is anorthitic (Avg ~An88), with little variation (An86-92.5). Trace element bulk rock analyses were collected via ICP-MS and individual mineral analyses with LA-ICP-MS (Figure 2). The bulk sample has an observable enrichment in light rare earth elements, with a notable depletion in Eu. Plagioclase is enriched in LREEs, depleted in HREEs, and has a positive Eu anomaly while pyroxene is enriched in HREEs with a negative Eu anomaly. Variations in trace element analyses is likely influenced by the presence of phosphates because are highly enriched in REEs and have a dramatic effect on the bulk domain compositions. Thermodynamic modeling: The software package, Perple_X, was used to calculate mineral phase equilibria over a range of conditions using a Gibbs free energy minimization approach [12]. Models used all major/minor elements except P2O5. Thermodynamic properties from [13] were used to constrain endmember phase stabilities. Activity models were used to describe mixing in phases with solid solution. Isochemical P-T phase diagrams were constructed for the bulk thin section, and the coarse, medium and fine grain domain compositions. Domain compositions were determined using microprobe analyses of phases identified in each domain and observed modal mineral abundancies. Thermodynamically stable pyroxene compositions were extracted from model results and compared to pyroxene compositions collected via EMPA, allowing us to calculate temperatures for metamorphic equilibrium. Results: Results that use the coarse domain composition (Fig. 3a) demonstrate overlap at T ~ 1020°C indicating high T equilibration. There was no overlap for the medium and fine grain domains, or the bulk composition (e.g., Fig. 3b) indicating that these are not equilibrium assemblages. These results were replicated using data from [8,20]. Discussion: The disequilibrium results from the bulk rock, fine grain and medium grain models imply that EET 90020 was modified during and/or after peak metamorphism (open system behavior). However, this is in contrast to the coarse domain where it appears as if equilibrium was maintained. We suggest that this conflict is explained by highly localized equilibrium occurring at millimeter length-scales, which has been observed in terrestrial metamorphism where aqueous fluid infiltrate [14] or melt loss occurs [15]. It is unlikely that aqueous alteration was significant in modifying the bulk composition of EET 90020, because it lacks hydrated minerals. However, the presence of melt is supported by the presence of an abundance of curved grain boundaries and spherical grains in the medium and fine grain domains This contrasts the coarse domain, where grain boundaries are angular. Given the evidence for disequilibrium in the medium and fine grain domains, it would be inappropriate to draw additional conclusions about textural evolution using thermodynamic models of those domains. However, modeling results of the coarse grain domain, where equilibrium was maintained, can provide useful insights into the geologic evolution of EET 90020. We approximate maximum metamorphic temperatures, using the Ca component in pyroxene, at ~1020°C (Fig. 4), which is consistent with previous two-pyroxene thermometry [11]. At this temperature, up to 10 vol % melt can be produced in the coarse grain domain, which is at the boundary of minimum melt needed in order to segregate and form a melt network [16]. Tridymite and plagioclase would be the first minerals to melt out during heating starting ~990°C. This is consistent with the observed melt textures formed by tridymite and plagioclase in the fine grain domain. We suggest that a partial melting model best explains the textural development of EET 90020. Upon heating, melt generated was either trapped, resulting in no net change in the localized rock composition, or migrated, resulting in disequilibrium between pyroxene and the surrounding matrix. A positive Eu anomaly in plagioclase indicates that all of the plagioclase was melted previously. This is consistent with previous studies that have suggested that EET 90020 represents a residual eucrite that experienced partial melting and subsequent melt loss [8]. We speculate that partial melting could have occurred when EET 90020 was heated in the asteroid’s lower crust or adjacent to an intrusion [7]. Future work will study other, texturally heterogeneous samples to see if EET 90020 presents a unique circumstance or whether crustal partial melting was ubiquitous on the eucrite asteroid.

Eucrites↗