Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High-Speed Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Controlling reversible phase transitions in rare-earth nickelates for novel memory devices

Resistive switching in correlated complex oxides is lucrative for emerging applications in neuromorphic computing, and densely scaled non-volatile memory. Electrical conductance of such complex oxides can be controllable switched across multiple orders of magnitude by either (a) electroforming a conduction channel (e.g., in tungsten oxide), or (b) inducing Mott-Hubbard transition (e.g., in rare-earth nickelates)– both via controlled migration of defects (such as oxygen vacancies) under applied bias. Nevertheless, the promise of such defect-driven electronic transitions are far from realized due to a lack of fundamental understanding of the atomic-scale processes that underlie migration and spatiotemporal evolution of oxygen vacancies over nano-to-mesoscopic length/timescales under applied electric field. In this project, we employ a synergistic integration of density functional theory (DFT) calculations, ab initio/classical molecular dynamics (AIMD/CMD) simulations, machine learning (ML), precision synthesis, and multi-modal X-ray imaging experiments to address this knowledge gap. Such an integrated approach offers to elucidate the correlations between subtle structural distortion and oxidation states; treat localized charge carriers; describe defect/ion transport in the presence of electric field; and, in turn, greatly advance the current understanding of microstructural evolution in complex oxides under applied bias. The fundamental knowledge gained from this work will enable precise control over hierarchical defect structures and unravel new routes to manipulate resistance states in complex oxides. This, in turn, will accelerate design of novel devices with desired set of neural functionalities, and high-speed densely-scaled resistive random access memory technologies.

36 MATERIALS SCIENCE↗

A Data Science and Machine Learning Platform Supporting Large Particle Accelerator Control and Diagnostics Applications Final Report: SBIR Initial Phase II DE-SC0022583

The Machine Learning Data Platform (MLDP) is a product providing full-stack support for data science, Machine Learning, and Artificial Intelligence (ML/AI) applications at particle accelerator and large experimental physics facilities. It supports ML/AI applications from front-end, high-speed acquisition of heterogeneous, time-series data, through data archiving and management, to back-end analysis. The MLDP embodies a “data-science ready” platform for data analysis and ML/AI applications in diagnosis, modelling, control, and optimization of these facilities. It provides data scientists and applications a consistent, datacentric interface to archive data standardizing implementation and deployment of ML/AI algorithms to different operations configurations within the same facility, or between facilities. Being an open-source, public-domain project, the MLDP is intended for broadest possible impact by increasing accessibility and minimizing the required expertise for installation and operation. The MLDP can also be deployed at user facilities for experimental data collection, archiving, and analysis. It is capable of acquisition and archiving of heterogeneous data from experimental equipment (e.g., images, arrays, structures, etc.) along with system hardware configurations (e.g., scalars, tables), control system process variables, and any metadata required for provenance. Thus, the MLDP can manage experimental data through its entire lifecycle, from acquisition and archiving, through analysis and investigation, to release and final publication.

43 PARTICLE ACCELERATORS↗

Impact of Backing Plate and Thermal Boundary Conditions for High-Speed Friction Stir Welding of 25-mm Thick Aluminum Alloy 7175-T79

Here this study demonstrates high-speed (150 mm/min) single pass friction stir butt joining of 25 mm thick aluminum alloy 7175-T79. To understand the impact of quenching and cooling rate on process responses, joint strength, and grain size distributions across the weld thickness, we performed a series of friction stir welding (FSW) trials in air and with a trailing water spray using steel and composite backing plates (BP). Welds made in air and trailing water spray exhibit significantly different hardness distributions across the nugget, heat affected zone (HAZ), and HAZ minimum hardness as evidenced by detailed microhardness mapping. The effect of trailing water spray (TWS) on joint efficiency overshadows the influence of BP composition due to the vastly different contribution to quenching. TWS also resulted in a multifaceted effect on FSW such as lowering processing temperature, increasing X and Z forces while lowering Y force, and narrow heat affecting zone. Finally, digital image correlation (DIC)-based fracture mode analysis and grain size measurements correlate with the hardness distribution.

42 ENGINEERING↗

L-PBF High-Throughput Data Pipeline Approach for Multi-modal Integration

Abstract Metal-based additive manufacturing requires active monitoring solutions for assessing part quality. Multiple sensors and data streams, however, generate large heterogeneous data sets that are impractical for manual assessment and characterization. In this work, an automated pipeline is developed that enables feature extraction from high-speed camera video and multi-modal data analysis. The framework removes the need for manual assessment through the utilization of deep learning techniques and training models in a weakly supervised paradigm. We demonstrate this pipeline’s capability over 700,000 high-speed camera frames. The pipeline successfully extracts melt pool and spatter geometries and links them to corresponding pyrometry, radiography, and processparameter information. 715 individual prints are examined to reveal melt pool areas that exceeds 0.07 mm 2 and pyrometry signal over a threshold (375 pyrometry units) were more likely to have defects. These automated processes enable massive throughput of characterization techniques.

36 MATERIALS SCIENCE↗

High-speed friction stir butt welding of 25.4 mm thick 7175-T79 aluminum alloy

This presents the first experimental demonstration of friction stir butt welding of 25.4 mm thick high-strength, precipitate-strengthened 7XXX aluminum alloy at a welding speed above 500 mm/min and penetration depth greater than 10 mm. Tool pin threads that terminate away from the shoulder region, helped mitigate nearby stress concentration during tool traversing, enabling a higher welding speed while avoiding pin fracture near shoulder. Two kinds of welds—one-sided with full penetration of the plate thickness and double-sided with partial penetration of the plate thickness—were conducted. Significant grain refinement (grain size 1.3 ± 0.8 µm) was evident at the junction of double-sided friction stir welding (FSW) compared to other regions of weld-nugget or base material. Cross-weld tensile testing with digital image correlation revealed high local strains at the junction of double-sided FSW before macro-yield. This strain concentration impeded the typical early necking on advancing/retreating sides of FSW joints, improving the yield strength of as-welded double-sided FSW by 20–24% over slow- to medium-speed one-sided FSW. In conclusion, the joint efficiency of as-welded, double-sided high-speed FSW was about 76% with respect to the base material’s ultimate tensile strength.

36 MATERIALS SCIENCE↗

Shock state distributions in porous tantalum and characterization with multipoint velocimetry

Heterogenous materials under shock compression can be expected to reach different shock states throughout the material according to local differences in microstructure and the history of wave propagation. Here, in this work, a compact, multiple-beam focusing optic assembly is used with high-speed velocimetry to interrogate the shock response of porous tantalum films prepared through thermal-spray deposition. The distribution of particle velocities across a shocked interface is compared to results obtained using a set of defocused interferometric beams that sampled the shock response over larger areas. The two methods produced velocity distributions along the shock plateau with the same mean, while a larger variance was measured with narrower beams. The finding was replicated using three-dimensional, mesoscopically resolved hydrodynamics simulations of solid tantalum with a pore structure mimicking statistical attributes of the material and accounting for radial divergence of the beams, with agreement across several impact velocities. Accounting for pore morphology in the simulations was found to be necessary for replicating the rise time of the shock plateau. The validated simulations were then used to show that while the average velocity along the shock plateau could be determined accurately with only a few interferometric beams, accurately determining the width of the velocity distribution, which here was approximately Gaussian, required a beam dimension much smaller than the spatial correlation lengthscale of the velocity field, here by a factor of ∼30×, with implications for the study of other porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

ClassNMSW- a real-time classification approach for non-recycled municipal solid waste using hyperspectral imaging

Real-time classification of non-recycled municipal solid waste (NMSW) is essential for efficient valorization. This study introduces ClassNMSW, a comprehensive framework for classifying 22 NMSW subclasses under industrial constraints by using hyperspectral imaging (HSI). A primary innovation of this work is the development of a variance-controlled spectral extraction algorithm. Unlike traditional methods that rely on simple averaging, this approach systematically investigates the extent of pixel extraction to minimize the loss of critical chemical information while maximizing data reduction thus ensuring high spectral fidelity with low computational cost. The approach developed in this work integrates automated, computer-vision-based background removal, eliminating the need for the manual thresholding common in current literature. To resolve ambiguities among chemically similar subclasses, a tiered classification and multi-camera fusion strategy (NIR17 and NIR22) is implemented. Results demonstrate that ClassNMSW achieves an object-wise weighted accuracy of 98.70% for single-sensor configurations and 100% under sensor fusion. A novel rolling-window strategy satisfies desired end-to-end latency of <2 s, satisfying the strict deterministic requirements of high-speed industrial sorting environments. The ClassNMSW framework provides a scalable foundation for advancing circularity and resource recovery in large-scale waste valorization operations.

99 - GENERAL AND MISCELLANEOUS↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flame stabilization in DME spray flames under engine-relevant conditions characterized by OH* chemiluminescence and formaldehyde laser-induced fluorescence

The transient and quasi-steady flame structures of Dimethyl Ether (DME) fuel sprays, produced by a single-hole injector (Spray D), were investigated using Planar Laser-Induced Fluorescence (PLIF) and chemiluminescence imaging in a constant-volume chamber under Engine Combustion Network (ECN) Spray A conditions (900 K ambient temperature, 60 bar ambient pressure, 1500 bar injection pressure, and 22.8 kg/m 3 ambient density). Low-temperature chemical reaction zones were visualized using formaldehyde (CH 2 O) PLIF with 355 nm excitation, while high-temperature flame regions were captured via chemiluminescence imaging of excited-state hydroxyl radicals (OH*). Both transient and quasi-steady flame structures clearly show the transition from CH 2 O to OH*, highlighting the progression from low- to high-temperature combustion, while the position of the flame is displaced for DME compared to reference hydrocarbon n-dodecane. Homogeneous reactor calculations with detailed chemistry and using adiabatic mixing for initial temperature show that CH 2 O peaks are significantly higher for DME at the same equivalence ratio, with a higher heat-release during the cool-flame regime with respect to the fuel heating value. Thus, the cool-flame dynamic as a precursor to high-temperature combustion and flame stabilization exhibit distinct behavior for DME relative to conventional hydrocarbons, and these phenomena are effectively resolved through the soot-free nature of DME and the high-speed, time-resolved diagnostics.

CH2O laser-induced fluorescence↗

Bright and durable scintillation from colloidal quantum shells

Abstract Efficient, fast, and robust scintillators for ionizing radiation detection are crucial in various fields, including medical diagnostics, defense, and particle physics. However, traditional scintillator technologies face challenges in simultaneously achieving optimal performance and high-speed operation. Herein we introduce colloidal quantum shell heterostructures as X-ray and electron scintillators, combining efficiency, speed, and durability. Quantum shells exhibit light yields up to 70,000 photons MeV −1 at room temperature, enabled by their high multiexciton radiative efficiency thanks to long Auger-Meitner lifetimes (>10 ns). Radioluminescence is fast, with lifetimes of 2.5 ns and sub-100 ps rise times. Additionally, quantum shells do not exhibit afterglow and maintain stable scintillation even under high X-ray doses (>10 9 Gy). Furthermore, we showcase quantum shells for X-ray imaging achieving a spatial resolution as high as 28 line pairs per millimeter. Overall, efficient, fast, and durable scintillation make quantum shells appealing in applications ranging from ultrafast radiation detection to high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE↗

Molecular beam epitaxy growth and characterization of GePb alloys

Pb based group-IV alloys such as GePb have been gaining interest as a potential alternative for infrared detectors, quantum materials, and high-speed electronic devices. Challenges remain in their growth due to the extremely low solid solubility of Pb in the Ge–Pb system. This paper reports molecular beam epitaxy growth of GePb alloy thin films on Ge(100) substrates. Effusion cells of Ge and Pb are used to control the flux ratio independently. The optimal substrate temperature is found to be near the thermocouple temperature of 300 °C based on the characterization of the grown films using high-resolution x-ray diffraction. A large change in the Ge:Pb beam equivalent pressure ratio from 10:1 to 1:1 results in only a minimal increase of the Pb composition from 0.74% to 2.84% as estimated from Raman spectroscopy and Rutherford backscattering spectrometry. Furthermore, scanning electron microscopy images show a large volume of Pb islands on the surface that form into either long trapezoidal rods or uniform droplets, with increasing Pb flux and growth time the density of Pb islands increased.

36 MATERIALS SCIENCE↗

Machine learning enhanced characterization and optimization of photonic cured MAPbI 3 for efficient perovskite solar cells

Photonic curing (PC) can facilitate high-speed perovskite solar cell (PSC) manufacturing because it uses high-intensity light pulses to crystallize perovskite films in milliseconds. However, optimizing PC conditions is challenging due to its many variables, and using power conversion efficiency (PCE) as the optimization metric is both time-consuming and labor-intensive. This work presents a machine learning (ML) approach to optimize PC conditions for fabricating methylammonium lead iodide (MAPbI 3 ) films by quantitatively comparing their ultraviolet-visible (UV-vis) absorbance spectra to thermal annealed (TA) films using four similarity metrics. We perform Bayesian optimization coupled with Gaussian process regression (BO-GP) to minimize the similarity metrics. Refining PC conditions using active learning based on BO-GP models, we achieve a PC MAPbI3 film with an absorbance spectrum closely matching a TA reference film, which is further verified by its crystalline and morphological properties. Thus, we demonstrate that the UV-vis absorption spectrum can accurately proxy film quality. Additionally, we use an AI-based segmentation model for a more efficient grain size analysis. However, when we use the optimized PC condition to fabricate PSCs, we find that interaction between MAPbI 3 and the hole transport layer (HTL) during PC critically degrades the PSC performance. By adding a buffer layer between the HTL and MAPbI 3 , the optimized PC PSCs produce a champion PCE of 11.8%, comparable to the TA reference of 11.7%. Using UV-vis similarity metrics instead of device PCE as the objective in our BO-GP method accelerates the optimization of PC processing conditions for MAPbI 3 films.

14 SOLAR ENERGY↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗