Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High frequency analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The matrix exponential in transient structural analysis

The primary usefulness of the presented theory is in the ability to represent the effects of high frequency linear response with accuracy, without requiring very small time steps in the analysis of dynamic response. The matrix exponential contains a series approximation to the dynamic model. However, unlike the usual analysis procedure which truncates the high frequency response, the approximation in the exponential matrix solution is in the time domain. By truncating the series solution to the matrix exponential short, the solution is made inaccurate after a certain time. Yet, up to that time the solution is extremely accurate, including all high frequency effects. By taking finite time increments, the exponential matrix solution can compute the response very accurately. Use of the exponential matrix in structural dynamics is demonstrated by simulating the free vibration response of multi degree of freedom models of cantilever beams.

Minnetyan, Levon↗

Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

Wilson, P. M.↗

New Evidence for Third Harmonic Electromagnetic Radiation in Interplanetary Type III Solar Radio Bursts

This article provides new evidence for a third harmonic component in the electromagnetic radiation generated by interplanetary type III solar radio bursts observed locally near 1 AU. This evidence comes mainly from the analysis of the low-frequency radio emissions observed by the Wind spacecraft. The analysis examines, at high-time and high-frequency resolution, the local type III radiation that is occasionally observed at Wind. The associated Langmuir waves and energetic electron beams, as well as simultaneous observations from the Solar Terrestrial Relations Observatory (STEREO) and Ulysses spacecraft where possible, are used to confirm the local nature of the observed radiation and to help identify the solar origin. We find that the detection of a third harmonic component in the local type III radiation near 1 AU is exceedingly rare. However, our analyses indicate that, in addition to the more commonly observed second harmonic component, a third harmonic component is sometimes conspicuously evident in the local type III radiation. We find that the third harmonic component, when observed, is less intense than the second harmonic component, with the intensity ratio varying between 0.3 and 0.7. Sometimes the third harmonic component is expected to be detected, but it is not observed.

Interplanetary↗

Integrated Physics-based Modeling and Experiments for Improved Prediction of Combustion Dynamics in Low-Emission Systems

Concurrent simulation and experiment was undertaken to assess the ability of a hybrid RANS-LES model to predict combustion dynamics in a single-element lean direct-inject (LDI) combustor showing self-excited instabilities. High frequency pressure modes produced by Fourier and modal decomposition analysis were compared quantitatively, and trends with equivalence ratio and inlet temperature were compared qualitatively. High frequency OH PLIF and PIV measurements were also taken. Submodels for chemical kinetics and primary and secondary atomization were also tested against the measured behavior. For a point-wise comparison, the amplitudes matched within a factor of two. The dependence on equivalence ratio was matched. Preliminary results from simulation using an 18-reaction kinetics model indicated instability amplitudes closer to measurement. Analysis of the simulations suggested a band of modes around 1400 Hz were due to a vortex bubble breakdown and a band of modes around 6 kHz were due to a precessing vortex core hydrodynamic instability. The primary needs are directly coupled and validated ab initio models of the atomizer free surface flow and the primary atomization processes, and more detailed study of the coupling between the 3D swirling flow and the local thermoacoustics in the diverging venturi section.

combustion↗

Effects of whole body heating on dynamic baroreflex regulation of heart rate in humans

The purpose of this project was to identify whether dynamic baroreflex regulation of heart rate (HR) is altered during whole body heating. In 14 subjects, dynamic baroreflex regulation of HR was assessed using transfer function analysis. In normothermic and heat-stressed conditions, each subject breathed at a fixed rate (0. 25 Hz) while beat-by-beat HR and systolic blood pressure (SBP) were obtained. Whole body heating significantly increased sublingual temperature, HR, and forearm skin blood flow. Spectral analysis of HR and SBP revealed that the heat stress significantly reduced HR and SBP variability within the high-frequency range (0.2-0.3 Hz), reduced SBP variability within the low-frequency range (0.03-0.15 Hz), and increased the ratio of low- to high-frequency HR variability (all P < 0.01). Transfer function gain analysis showed that the heat stress reduced dynamic baroreflex regulation of HR within the high-frequency range (from 1.04 +/- 0.06 to 0.54 +/- 0.6 beats. min(-1). mmHg(-1); P < 0.001) without significantly affecting the gain in the low-frequency range (P = 0.63). These data suggest that whole body heating reduced high-frequency dynamic baroreflex regulation of HR associated with spontaneous changes in blood pressure. Reduced vagal baroreflex regulation of HR may contribute to reduced orthostatic tolerance known to occur in humans during heat stress.

Non-NASA Center↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗

Thermal Analysis of a Polypropylene Capacitor for Resonant Tuning Networks in WPT Applications

This study presents the thermal analysis of polypropylene capacitors operating at high frequencies and high currents used in the resonant tuning networks for electric vehicle (EV) wireless charging systems. The thermal analysis and performance results of the CELEM polypropylene capacitors are presented at different currents for a polyphase wireless power transfer (WPT) system while the study can be expanded to other capacitors by different manufacturers. Thermal equivalent circuit of the capacitor is derived and required cold plate size and design calculations are conducted by modeling the polypropene capacitor in MATLAB. The polypropene capacitor's finite element analysis (FEA) model is developed using COMSOL Multiphysics simulation software, and the thermal characteristics and analysis of the capacitor are presented in this paper.

Aktas, Ahmet↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

A comparison of analytical results for 20 K LOX/hydrogen instabilities

Test data from NASA Lewis' Effect of Thrust Per Element on Combustion Stability Characteristics of Hydrogen-Oxygen Rocket Engines test program are used to validate two recently released stability analysis tools. The first tool is a design methodology called ROCCID (ROCket Combustor Interactive Design). ROCCID is an interactive design and analysis methodology that uses existing performance and combustion stability analysis codes. The second tool is HICCIP (High frequency Injection Coupled Combustion Instability Program). HICCIP is a recently developed combustion stability analysis model. Using a matrix of models, results from analytic comparisons with 20 K LOX/H2 experimental data are presented.

Klem, Mark D.↗

A comparison of analytical results for 20 K LOX/hydrogen instabilities

Test data from NASA Lewis' Effect of Thrust Per Element on Combustion Stability Characteristics of Hydrogen-Oxygen Rocket Engines test program are used to validate two recently released stability analysis tools. The first tool is a design methodology called ROCCID (ROCket Combustor Interactive Design). ROCCID is an interactive design and analysis methodology that uses existing performance and combustion stability analysis codes. The second tool is HICCIP (High frequency Injection Coupled Combustion Instability Program). HICCIP is a recently developed combustion stability analysis model. Using a matrix of models, results from analytic comparisons with 20 K LOX/H2 experimental data are presented.

Klem, Mark D.↗

The high-overtone p-mode spectrum of the rapidly oscillating Ap star HR 1217 (HD 24712) - Results of a frequency analysis of 324 hr of multi-site photometric observations obtained during a 46-d time-span in 1986

The present high-speed photometry for the rapidly oscillating Ap star HR 1217 indicates that the 6-min light variations are amplitude-modulated, in phase with the magnetic variations. Amplitude and magnetic maxima coincide, while the mean light minimum occurs at a perhaps significantly different time. It is established that HR 1217 is an oblique rotator with a centered dipole magnetic field, as well as an oblique pulsator whose pulsation and magnetic axes are aligned. There are six principal frequencies of pulsation; the secondary frequencies indicate that the principal ones are amplitude-modulated on a time-scale of months.

Kurtz, D. W.↗

Performance analysis of digital FM demodulators for fading channels in the threshold region

The quasi-optimum digital FM demodulators for fading channels reported earlier (1975) reflected the system performance accurately under high signal to noise ratio conditions. In this paper, the prediction of the system performance for low SNR values is considered. A new set of error variance algorithms is developed from the filter algorithm assuming a Gaussian distribution for the state estimation errors and taking the effect of high frequency terms into consideration. Simulation analysis for an FM system with Rician fading channel shows that these algorithms predict the system performance accurately in the threshold region.

Dharamsi, M. T.↗

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of n-type Dry Thermally Oxidized 6H-SiC Metal-oxide Semiconductor Diodes by Quasistatic and High-Frequency Capacitance Versus Voltage and Capacitance Transient Techniques

Dry-oxidized n-type 6H-SiC metal-oxide-semiconductor capacitors are investigated using quasistatic capacitance versus voltage (C-V), high-frequency C-V, and pulsed high-frequency capacitance transient (C-t) analysis over the temperature range from 297 to 573 K. The quasistatic C - V characteristics presented are the first reported for 6H-SiC MOS capacitors, and exhibit startling nonidealities due to nonequilibrium conditions that arise from the fact that the recombination/generation process in 6H-SiC is extraordinarily slow even at the highest measurement temperature employed. The high-frequency dark C-V characteristics all showed deep depletion with no observable hysteresis. The recovery of the high-frequency capacitance from deep depletion to inversion was used to characterize the minority-carrier generation process as a function of temperature. Zerbst analysis conducted on the resulting C-t transients, which were longer than 1000 s at 573 K, showed a generation lifetime thermal activation energy of 0.49 eV.

Neudeck, P.↗

An analysis of project high water data

Optical and radio frequency electromagnetic observations of high water release in ionosphere and atmospheric turbulence following liquid release in space

HIGH WATER PROJECT↗

Measuring Vibrations With Nonvibration Sensors

Information about vibrations of structure and/or of nonvibration sensor attached to structure extracted from output of sensor. Sensor operated in usual way except, output fed to power-spectral-density analyzer. Vibrational components easily distinguishable in analyzer output because they have frequencies much higher than those of more-slowly-varying temperature, pressure, or other normally desired components. Spectral-analysis technique applied successfully to high-frequency resistance changes in output of platinum-wire resistance thermometer: vibrational peaks in resistance frequency spectrum confirmed by spectrum from accelerometer. Technique also showed predicted 17-kHz vibrational resonance in strain-guage-supporting beam in pressure sensor.

Hill, Arthur J.↗