Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Power RF Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Compact RF ion source for industrial electrostatic ion accelerator

Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF Distribution System for High Power Test of the SNS Cryomodule

A four-way waveguide RF power distribution system for testing the Spallation Neutron Source (SNS) multi-cavity cryomodule to investigate the collective behavior has been developed. A single klystron operating at 805MHz for 1.3 msec at 60Hz powers the 4-way waveguide splitter to deliver up to 400 kW to individual cavities. Each cavity is fed through a combination of waveguide splitters and vector modulators (VM) to provide independent magnitude and phase controls. The waveguide vector modulator consists of two quadrature hybrids and two motorized waveguide phase shifters. The phase shifters and the assembled waveguide vector modulators were individually tested and characterized for low power and high RF power in the SNS RF test facility. Precise calibrations of magnitude and phase were performed to generate the look up tables (LUTs) to provide operational references during the cryomodule test. An I-Q demodulator module was developed and utilized to measure relative phases in pulsed high RF power operation. PLC units were developed for mechanical control of the phase shifters. Initial low/high power measurements were made using LabVIEW. An operation algorithm has been implemented into EPICS control for the cryomodule test stand.

43 PARTICLE ACCELERATORS↗

Surface plasma source with saddle antenna radio frequency plasma generator

A prototype RF H{sup -} surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA/kW. Control experiments with H{sup -} beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High power 325 MHz vector modulators for the Fermilab High Intensity Neutrino Source (HINS)

One of the goals of the low energy 60 MeV section of the HINS H{sup -} linac [1] is to demonstrate that a total of {approx}40 RF cavities can be powered by a single 2.5 MW, 325 MHz klystron. This requires individual vector modulators at the input of each RF cavity to independently adjust the amplitude and phase of the RF input signal during the 3.5 ms RF pulse. Two versions of vector modulators have been developed; a 500 kW device for the radiofrequency quadrupole (RFQ) and a 75 kW modulator for the RF cavities. High power tests showing the vector modulator phase and amplitude responses will be presented.

43 PARTICLE ACCELERATORS↗

Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam energy at ~5MeV. Simulation shows that in the 3+1/2 DC- C injector, there is a region the beam could be over focused by RF electromagnetic field and the transverse emittance in the transport line up to linac will increase instantly due to over focusing. In order to eliminate this effect on beam emittance, several solutions are investigated to avoid over focusing. This result is very important for beam loading experiment for low bunch charge operation. Meanwhile, different merger structures are compared in terms of error sensitivity and emittance increase with space charge effect. In recirculation beam line, a new symmetric 180{degree} arc structure is designed. It fulfills the achromatic condition and adjustable bunch compression. These two parameters are controlled by different Quads knob. With this novel structure, the recirculation lattice can achieve path length adjustment, bunch compression and decompression in a large range. With beamline error, the beam central orbit will deviate from the designed trajectory. An orbit correction system is optimized, which balances between cost and performance of orbit after correction at design level. Different methods are used to estimate its robustness. The BBU instability, especially multi-pass BBU imposed a potentially severe limitation to the average current that can be accelerated in an ERL. Simulation gives the harmful HOMs and predicts that the threshold average current in this machine is much higher than the possible operation current. This work is based on the existing facility in PKU, so it provides guidelines for the facility operation and upgrade in the future. The theoretical analysis of ERL requirement and FEL requirement on beam transport line and beam property paves the way for future ERL research.

43 PARTICLE ACCELERATORS↗

Phase and Frequency Locked Magnetrons for SRF Sources

Typically, high power sources for accelerator applications are multi-megawatt microwave tubes that may be combined together to form ultra-high-power localized power stations. The RF power is then distributed to multiple strings of cavities through high power waveguide systems which are problematic in terms of expense, efficiency, and reliability. Magnetrons are the lowest cost microwave source in dollars/kW, and they have the highest efficiency (typically greater than 85%). However, the frequency stability and phase stability of magnetrons are not adequate, when used as power sources for accelerators. Novel variable frequency cavity techniques have been developed which will be utilized to phase and frequency lock magnetrons, allowing their use for either individual cavities, or cavity strings. Ferrite or YIG (Yttrium Iron Garnet) materials will be attached in the regions of high magnetic field of radial-vaned, π-mode structures of a selected ordinary magnetron. A variable external magnetic field that is orthogonal to the magnetic RF field of the magnetron will surround the magnetron to vary the permeability of the ferrite or YIG material. A cold test assembly has been built, and measurements of the change in frequency as a function of magnetic field as well as mode suppression will be presented. A general feed-back loop will also be designed to control the magnetic field.

43 PARTICLE ACCELERATORS↗

Nanosecond rf-Power Switch for Gyrotron-Driven Millimeter-Wave Accelerators

The development of alternative mm-wave high-gradient, >200 MV/m, accelerating structures offers a promising path to reduce the cost and footprint of future TeV-scale linear colliders, as well as linacs for industrial, medical, and security applications. The major factor limiting accelerating gradient is vacuum rf breakdown. The probability of such breakdowns increases with pulse length. For reliable operation, millimeter-wave structures require nanoseconds-long pulses at the megawatt level. This power is available from gyrotrons, which have a minimum pulse length on the order of microseconds. To create shorter pulses and to reliably detect rf breakdowns, we developed the following devices: a laser-based rf switch capable of selecting 10 ns long pulses out of the microseconds long gyrotron pulses, thus enabling the use of the gyrotrons as power sources for mm-wave high-gradient linacs, and a shot-to-shot sub-THz spectrometer with high-frequency resolution, capable of detecting pulse shortening due to rf breakdowns. We will describe the principle of operation of these devices and their achieved parameters. Here, we also report on the experimental demonstration of these devices with the high-power gyrotron at the Massachusetts Institute of Technology. In the experiments, we demonstrate nanosecond rf power modulation, shot-to-shot measurements of the pulse spectra, and detection of rf breakdowns.

43 PARTICLE ACCELERATORS↗

On the Phase Grouping Mechanism for a Magnetron Coherent Oscillation

CW magnetrons, developed for industrial heaters, but driven by an injection-locking signal were suggested to power Superconducting RF (SRF) cavities due to higher efficiency and lower cost of generated RF power per Watt than traditionally used RF sources (klystrons, IOTs, solid-state amplifiers). When the magnetrons are intended to feed Room Temperature (RT) cavities, the injected phase or frequency locking signal may provide required phase or frequency stability of the accelerating field. However, when the magnetron RF sources are intended to feed high Q-factor SRF cavities, the sources must be controlled in phase and power in a wide bandwidth to compensate parasitic phase and amplitude modulations caused by microphonics. In dependence on parameters of magnetron and the injection-locking signal one can choose regime most suitable for feeding SRF cavities, enabling magnetron almost coherent oscillation at the wide bandwidth of control. A novel approach considering magnetrons as quasi-coherent or coherent RF generators enables choosing the tube parameters and operation most suitable for various SRF accelerators.

43 PARTICLE ACCELERATORS↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled plasmas in argon

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this work, test particle simulations are used to describe the nature and role of the ballistic electrons, which originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased upper electrode and are then accelerated in the sheath toward the opposite non-dc biased lower electrode. This opposite electrode, on which a wafer is placed, may have rf bias power applied to it at low frequencies. 2 MHz is typical. While a hybrid dc/rf plasma source is sustained by the VHF power source, simulations reveal ballistic electrons assist in the production of a plasma characterized by a relatively high ionization rate constant, especially in the dc sheath. The dc source helps to provide a source of high energy electrons that may reach the wafer. However, when the rf bias is applied on the lower electrode, ballistic electrons are confined in the potential well formed between electrodes and easily thermalized in the bulk. The simulated electron density dependencies on the dc bias and lower electrode rf power describe a dual mode source and are consistent with measured data. When no rf power is applied on the electrode opposite to the dc power source, the bulk electron density drops with increasing dc power at constant VHF power; when rf power is applied to the electrode opposite to the dc power source, the bulk electron density increases with dc power at constant VHF power. The fraction of electrons significantly above thermal reaching the wafer is much higher when no rf power is applied at the lower electrode but the total flux lower. Depending on its level, rf power applied to the wafer may effectively suppress the number of ballistic electrons that reach the wafer. Finally, the ionization rate constant due to ballistic electrons can be fitted as a simple function of the electric field in the dc sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of high power radio frequency radial combiner for proton accelerator

A simplified design method has been proposed for systematic design of novel radio frequency (rf) power combiner and divider, incorporating radial slab-line structure, without using isolation resistor and external tuning mechanism. Due to low insertion loss, high power capability, and rigid mechanical configuration, this structure is advantageous for modern solid state rf power source used for feeding rf energy to superconducting accelerating structures. Analysis, based on equivalent circuit and radial transmission line approximation, provides simple design formula for calculating combiner parameters. Based on this method, novel 8-way and 16-way power combiners, with power handling capability of 4 kW, have been designed, as part of high power solid state rf amplifier development. Detailed experiments showed good performance in accordance with theory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

JLab CW Cryomodules for 4th Generation Light Sources

Fourth generation light sources hold the prospect of unprecedented brightness and optical beam quality for a wide range of scientific applications. Many of the proposed new facilities will rely on large superconducting radio frequency (SRF) based linacs to provide high energy, low emittance CW electron beams. For high average power applications there is a growing acceptance of energy recovery linac (ERL) technology as the way to support large recirculating currents with modest RF power requirements. CW SRF and high current ERLs are two core competencies at Jefferson Lab. JLab has designed and built a number of CW cryomodules of several different types starting with the original CEBAF design, with variations for higher current in the two generations of JLab’s free-electron laser (FEL), through two intermediate prototypes to the final high-performance module for the 12 GeV upgrade. Each of these represent fully engineered and tested configurations with a variety of specifications that could be considered for possible use in fourth generation light sources. Furthermore JLab has been actively pursuing advanced concepts for highcurrent high-efficiency cryomodules for next generation ERL based FEL’s. These existing and proposed designs span the range from about 1mA single-pass to over 100 mA energy recovered current capability. Specialized configurations also exist for high-current non-energy recovered sections such as the injector region where very high RF power is required. We discuss the performance parameters of these existing and proposed designs and their suitability to different classes of fourth generation light sources.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

Operating Klystrons at the Spallation Neutron Source – Two Decades of Perspective

Klystron amplifiers have been operated at the Spallation Neutron Source (SNS) in support of the user program since 2006. SNS tubes have amassed over 100,000 hours of high-voltage and filament-on time providing a significant source of operational statistics for high power, high-duty klystrons. Additionally, the SNS Radiofrequency (RF) Systems Group has developed operational methods to mitigate specific reliability challenges, such as cathode arcing and output power instability. Despite much progress, many of these challenges persist, prompting the SNS to update the procedures used for klystron processing as well as develop a higher throughput test stand.

Moss, John [ORNL] (ORCID:0009000085988916)↗

A Permanent-Magnet Microwave Ion Source for a Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x1011 n/s for D-T and ~;;1x1010 n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm2) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm2 was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Magnetron Stability and Reduced Noise in Efficient Transmitters for Superconducting Accelerators

State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.

Kazakevich, G.↗

CW/Pulsed H{sup −} ion beam generation with PKU Cs-free 2.45 GHz microwave driven ion source

Circular accelerators used for positron emission tomography (PET, i.e. accelerator used for make radio isotopes) need several mA of CW H- ion beam for their routine operation. Other facilities, like Space Radio-Environment Simulate Assembly (SPRESA), require less than 10 mA pulsed mode H{sup −} beam. Caesium free negative hydrogen ion source is a good choice for those facilities because of its compact structure, easy operation and low cost. Up to now, there is no H{sup −} source able to produce very intense H{sup −} beams with important variation of the duty factor{sup [1]}. Recently, a new version of 2.45 GHz microwave H{sup −} ion source was designed at PKU, based on lessons learnt from the previous one. This non cesiated source is very compact thanks to its permanent magnet configuration. Special attention was paid on the design of the discharge chamber structure, electron dumping and extraction system. Source test to produce H{sup −} ion beams in pulsed and CW mode was carried out on PKU ion source test bench. In CW mode, a 10.8 mA/30keV H{sup −} beam with rms emittance about 0.16 π·mm·mrad has been obtained with only 500 W rf power. The power efficiency reaches 21 mA/kW. In pulsed mode with duty factor of 10% (100Hz/1ms), this compact source can easily deliver 20 mA H{sup −} ion beam at 35 keV with rms emittance about 0.2 π·mm·mrad when RF power is set at 2.2 kW (peak power). Several hour successive running operation in both modes and totaling more than 200 hours proves its high quality. The outside dimension of this new H{sup −} source body is ϕ116 mm × 124 mm, and the entire H{sup −} source infrastructure, including rf matching section, plasma chamber and extraction system, is ϕ310 × 180 mm. The high voltage region is limited with in a ϕ310 mm × 230 mm diagram. Details are given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the effects of a thin dielectric layer on low-pressure hydrogen capacitive discharges driven by combined radio frequency and pulse power sources

Negative hydrogen ion sources, for instance for fusion devices, currently attract considerable attention. To generate the precursors—highly rovibrationally excited hydrogen molecules—for negative hydrogen ions effectively by electron excitation, a thin dielectric layer is introduced to cover the surface of the electrically grounded electrode of two parallel metal plates in a low-pressure hydrogen capacitive discharge driven by combined rf and pulse power sources. To understand the characteristics of such discharges, particle-in-cell simulations are conducted to study the effects that the single dielectric layer would bring onto the discharges. The simulation results show that the dielectric layer leads to a much higher plasma density and a much larger production rate of highly vibrationally excited hydrogen molecules compared to discharges without the dielectric layer on the electrode. Further investigation indicates that the nonlinear oscillation of the electrons induced by the nanosecond-pulse continues until it is finally damped down and does not show any dependence on the pulse plateau-time, which is in stark contrast to the case without the dielectric layer present. The physical reason for this phenomenon is explored and explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High power solid state rf amplifier for proton accelerator

A 1.5 kW solid state rf amplifier at 352 MHz has been developed and tested at RRCAT. This rf source for cw operation will be used as a part of rf system of 100 MeV proton linear accelerator. A rf power of 1.5 kW has been achieved by combining output power from eight 220 W rf amplifier modules. Amplifier modules, eight-way power combiner and divider, and directional coupler were designed indigenously for this development. High efficiency, ease of fabrication, and low cost are the main features of this design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗