Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Solar heating system

A system is disclosed for using solar energy to heat the interior of a structure. The system utilizes a low cost solar collector to heat a recirculating air mass which then flows through a series of interconnected ducts and passageways without the use of exterior fans or blowers. Heat is transferred from the air mass to the structure's interior and the air mass is then reheated.

Jensen, R. N.↗

Solar heating system at Security State Bank, Starkville, Mississippi

The 312 square feet of Solaron flat plate air collectors provide for 788 square feet of space heating, an estimated 55 percent of the heating load. Solar heated air is distributed to the 96 cubic foot steel cylinder, which contains two inch diameter rocks. An air handler unit moves the air over the collector and into the steel cylinder. Four motorized dampers and two gravity dampers are also part of the system. A Solaron controller which has sensors located at the collectors, rock storage, and at the return air, automatically controls the system. Auxiliary heating energy is provided by electric resistance duct heaters.

Source record↗

A reliable solar-heating system--Huntsville, Alabama

Final report on solar-heating demonstration project in Huntsville, Alabama, is rich in technical data, planning considerations, test and maintenance data, and other information. It can be useful reference for those planning similar systems.

Source record↗

Test and evaluation of a solar-heating system

Report documents results of evaluation tests performed on components of commerical solar heating and hot water system. Subsystems tested include flat plate solar collector, energy transport module, and control panel. Tests conducted include snow and wind loads, flame spread, and smoke classification as well as solar heating operation.

Source record↗

Solar-heating system design data brochure

Report details design and performance specifications of complete system for space and hot-water heating that is assembled from commercially available components. System can meet need of single family dwelling having approximately 1,200 sq ft of floor area and can be scaled to requirements of larger or smaller installations.

Source record↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orientation of heated premise in the design of insolation passive heating systems

The technique for calculating the start and end times and the direct sunlight illumination period is described. The cumulative solar radiation (SR) falling on the front surface of translucent enclosures (TE) of heated premise (HP) is found. The final design results are based on processing 4-year generalized data from the Parkent weather station.

14 SOLAR ENERGY↗

GeoVision Analysis Supporting Task Force Report: Thermal Applications-Quantifying Technical, Economic, and Market Potential of Geothermal District Heating Systems in the United States

This report describes research and analysis performed in support of the U.S. Department of Energy Geothermal Technologies Office for its Geothermal Vision Study. A summary of the study is captured in DOE’s report, GeoVision: Harnessing the Heat Beneath Our Feet and included ground-breaking, detailed research on geothermal technologies. The study projects and quantifies the future electric and nonelectric deployment potentials of these geothermal technologies within a range of scenarios in addition to their impacts on U.S. jobs, the economy, and environment. Coordinated by the U.S. Department of Energy Geothermal Technologies Office, the Geothermal Vision Study development relied on collecting, modeling, and analyzing robust data sets through seven national laboratory partners that were organized into eight technical task force groups. These task forces and their respective principal leading national laboratory are listed in Table F-1. The table also provides a guide to the final research documents produced by each GeoVision task force. In most cases, these were prepared as laboratory reports, and they are referenced accordingly. Consult these external reports for detailed discussions of the topics contained within, which form the basis of the GeoVision analysis.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Cost analysis of new and retrofit hot-air type solar assisted heating systems

A detailed cost analysis/cost improvement study was performed on two Department of Energy/National Aeronautics and Space Administration operational test sites to determine actual costs and potential cost improvements of new and retrofit hot air type, solar assisted heating and hot water systems for single family sized structures. This analysis concentrated on the first cost of a system which included procurement, installation, and integration of a solar assisted heating and hot water system on a new or retrofit basis; it also provided several cost projections which can be used as inputs to payback analyses, depending upon the degree of optimism or future improvements assumed. Cost definitions were developed for five categories of cost, and preliminary estimates were developed for each. The costing methodology, approach, and results together with several candidate low cost designs are described.

Stewart, R. D.↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Biomass District Heat System for Interior Rural Alaska Villages

Alaska Village Initiatives (AVI) from the outset of the project had a goal of developing an integrated village approach to biomass in Rural Alaskan villages. A successful biomass project had to be ecologically, socially/culturally and economically viable and sustainable. Although many agencies were supportive of biomass programs in villages none had the capacity to deal effectively with developing all of the tools necessary to build a complete integrated program. AVI had a sharp learning curve as well. By the end of the project with all the completed tasks, AVI developed the tools and understanding to connect all of the dots of an integrated village based program. These included initially developing a feasibility model that created the capacity to optimize a biomass system in a village. AVI intent was to develop all aspects or components of a fully integrated biomass program for a village. This meant understand the forest resource and developing a sustainable harvest system that included the “right sized” harvest equipment for the scale of the project. Developing a training program for harvesting and managing the forest for regeneration. Making sure the type, quality, and delivery system matched the needs of the type of boiler or boilers to be installed. AVI intended for each biomass program to be of the scale that would create jobs and a sustainable business.

09 BIOMASS FUELS↗

Plasma production and ion heating systems for the Material Plasma Exposure eXperiment

Plasma production and ion heating in the Material Plasma Exposure eXperiment (MPEX), whose design is nearing completion, is accomplished using continuous wave RF power with average power density up to 1.6 MW/m2 at the plasma interface. Plasma is produced using helicon waves coupled through a single helical antenna at 13.56 MHz with power supplied by three 100 kW fixed-frequency RF generators feeding a power combiner network followed by the matching network and launcher. The helicon source can utilize various gasses including hydrogen, deuterium, and helium, with a magnetic field strength in the source region up to 0.2 T, and maximum device |B| of 2.5 T. Power is coupled to ions via ion cyclotron heating at the fundamental resonance using a pair of phased helical antennas operating in the frequency range 4-9 MHz, that launch waves towards the resonance from the antenna region where ω > ωci. ICH power is supplied by a single 500 kW tunable RF transmitter through a 90° power splitter and matching/decoupling network. In the case of both the helicon and ICH systems the antennas are located external to the vacuum, with power transferred through novel water-cooled coaxial vacuum windows consisting of fused quartz outer cylinders and silicon nitride inner cylinders with forced convection water cooling between them. The antenna enclosures are pressurized with dry air to 3 bar absolute for voltage standoff.Several 3-D COMSOL models have been created to simulate the two systems. A model of the helicon region utilizing a cold plasma dielectric tensor with accurate magnetic field and realistic plasma density profiles has been used to calculate the plasma loading/complex antenna input impedance at the launcher feed for various ne and |B| values, for the purpose of estimating power handling. It also incorporates the geometry of all launcher structures relevant to this determination. A still more detailed model of the launcher together with a lossy dielectric plasma surrogate has been used to determine RF electric field values and power losses in the device components.Similar models have been produced to predict the performance and power handling of the ICH launcher. For this device the impedance matrix of the two-element antenna array is calculated using a warm plasma model, necessary to properly determine the wave propagation and absorption.

Goulding, Richard↗

Heating system of pellet samples integrated with terahertz spectrometer

This article describes automation of temperature-dependent terahertz spectroscopic experiments. The proposed dual-heater temperature controller based on a cascade proportional-integral-derivative algorithm provides smooth temperature changes in the polyethylene-based pharmaceutical pellet samples. The device has been integrated with a terahertz time-domain spectrometer. Thermodynamic experiments can now be performed without any probe inserted into the measured sample. Selected results of temperature-induced evolution in terahertz spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Differential pumping requirements for the light-ion helicon source and heating systems of Proto-MPEX

The physics of electron and ion heating of high-density deuterium helicon plasmas (>3 × 10 19 m –3 ) in the Proto-Material Plasma Exposure Experiment linear device are under investigation. Theoretical estimates indicate that for efficient heating, discharges with very low neutral gas content ( &laquo; 0.1 Pa) in the heating sections are required to minimize collisional losses and charge exchange interactions with neutrals. However, this requirement is typically not compatible with the neutral gas pressures (1–2 Pa) commonly used in high-density, light-ion helicon sources. To satisfy these competing requirements, differential pumping techniques are needed. Here, results are presented that demonstrate the production of high-density discharges (2–6 × 10 19 m –3 ) with very low neutral gas content (<0.01 Pa) and high degree of ionization (>75%) in the heating sections. Results indicate that the best fueling location is upstream of the plasma source. We elaborate on the key aspects that must be considered to produce these discharges: (1) fueling location, radio-frequency pulse length, and magnetic field configuration, (2) flow rate and timing of the gas injection, and (3) use of conductance-limiting elements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗