DUCTED ASSEMBLY STEADY STATE HEAT TRANSFER SOFTWARE

The Ducted Assembly Steady State Heat transfer software (DASSH) performs full core, steady state, subchannel temperature calculations for hexagonal, ducted assemblies. DASSH is targeted for use in the early stages of the reactor design process when assembly characteristics may not be defined or are undergoing considerable changes. DASSH provides a relatively rapid assessment of the temperature and flow distribution to inform reactor design updates and analysis.

ATZ, MILOSIVO↗

OTERR User Manual

OTERR (Optimization of TEst Reactor Reloading) is a software tool created to assist in the determination of optimal fuel reloading patterns for test reactors. The intended application is for the Versatile Test Reactor (VTR) program, but it provides functions that could be useful for analysis and optimization of many types of fast reactors. OTERR does not perform neutron/gamma transport, heat transfer, thermal hydraulics, or depletion calculations. Instead, it acts as a wrapper around codes that provide these capabilities, with a native genetic algorithm optimization capability. At this time, wrapping is only implemented for Argonne Reactor Computation (ARC) codes DIF3D, REBUS, and GAMSOR, and SE2-ANL. OTERR also has capabilities to facilitate input creation for DASSH, a thermal hydraulics code similar to SE2- ANL being developed for the VTR program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation of an Orificing Optimization Algorithm in the DASSH Subchannel Analysis Code

The Ducted Assembly Steady-State Heat transfer code (DASSH) performs full-core subchannel thermal hydraulics calculations in liquid metal fast reactors. One of the applications of subchannel codes is to optimize coolant flow orificing. As a design activity, the primary task is to determine the best way to divide assemblies into groups and distribute coolant flow rates among them. This report documents an algorithm implemented in DASSH to automatically optimize coolant orificing. Over the course of multiple iterations, DASSH determines the orifice grouping and flow distribution that minimizes peak coolant, clad, or fuel temperatures across all timesteps for a user-specified number of assembly groups. The total coolant flow rate in the reactor is constrained to achieve the specified core-average outlet temperature. The flow rate to each orifice group may also be constrained by the allowable pressure drop. The distribution of coolant flow among groups is accelerated using a predictor-corrector algorithm based on interpolated results from single-assembly parametric calculations. The assembly orificing grouping is initially predicted based on assembly power but can be refined if results demonstrate that an assembly would fit better in another group. The algorithm is demonstrated with two case studies. The first is a simple model for a reactor core consisting of just fuel assemblies; the pin power distributions are specified to create a situation where the initial assembly grouping prediction is suboptimal. This example is used to describe the initial grouping, demonstrate convergence over multiple iterations, and highlight the impact of regrouping. Then, the algorithm is applied to minimize peak clad and fuel temperatures in an example sodium-cooled fast reactor, the Versatile Test Reactor. The multicycle optimization confirms prior calculations for the reference core design. The example highlights how optimizing for different peak temperatures affects the results and demonstrates the use of the pressure drop constraint to limit the maximum flow rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of molar expansion ratio of fuels on engine efficiency

Fuel properties have a strong impact on the efficiency of internal combustion engines. Contrary to other physical and thermochemical fuel properties, the molar expansion ratio is normally ignored. Molar expansion ratio is the ratio of number of moles of the products to the reactants. In this work, the impact of the fuel’s molar expansion ratio on engine efficiency is investigated. Findings are based on simulations of a spark ignition engine using different fuels (standard fuels and user-defined fuels) and different dilution ratios. Simulations without heat transfer and friction were performed first. The combustion then takes place at top dead center with a very short combustion duration to approach the ideal Otto cycle. The heat transfer and friction were then added step by step. From this analysis, it could be concluded that the heat loss and friction work decrease as molar expansion ratio increases. The gross indicated and brake thermal efficiencies thus increase. User-defined fuels with different molar expansion ratio, but the same physical and thermochemical properties were then employed. The simulated results showed that the brake thermal efficiency increases by around 1.15% with an increase in molar expansion ratio of 0.02 compared to a fuel with a molar expansion ratio of unity. Lastly, the simulation was also done with air and exhaust gas recirculation dilution.

42 ENGINEERING↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

Investigating Performance of Geothermal Reservoirs With Bi-Directional Heat Transfer for Seasonal Thermal Storage Using Thermal-Hydraulic Reservoir Simulations

This paper presents initial simulation results of deep subsurface seasonal thermal storage of waste heat from a natural gas-fired power plant during the summer months for providing heating during winter months at the Cornell University main campus in Ithaca, New York. An injection temperature profile is calculated with the MEnU tool and numerical reservoir simulations are conducted with the simulator FALCON. Both a porous medium and large single fracture geothermal reservoir are considered at about 3 km depth with initial reservoir temperature of 75 degrees C. Simulations indicate that a much smaller reservoir - which is technically easier and less risky to develop - is sufficient when operating the reservoir for seasonal thermal storage instead of for continuous heat production. For example, storing 13 GWh of heat seasonally in a 100 m thick porous medium based on the Galway formation requires about 65 m of well spacing to limit the yearly variation in production temperature to 10 degrees C. Operating this reservoir for continuous heat production would require a well spacing of 365 m to limit the thermal decline to 10 degrees C after 10 years. Neglecting wellbore heat losses and assuming uniform and homogeneous properties, a round-trip thermal efficiency of 100% can be obtained if the yearly averaged injection temperature matches the initial reservoir temperature.

district heating↗

Experimental and Numerical Analysis of Additively Manufactured Inconel 718 Coupons With Lattice Structure

Abstract In the present paper, two lattice geometries suitable for near surface and double wall cooling were developed and tested. The first type of unit cell consisted of six ligaments of 0.5 mm diameter joined at a common vertex near the middle. The second type of unit cell was derived from the first type by adding four mutually perpendicular ligaments in the middle plane. Two lattice configurations, referred to as L1 and L2, respectively, were obtained by repeating the corresponding unit cell in streamwise and spanwise directions in an inline fashion. Test coupons consisting of these lattice geometries embedded inside rectangular cooling channel with dimensions of 2.54 mm height, 38.07 mm width, and 38.1 mm in length were fabricated using Inconel 718 powder and selective laser sintering (SLS) process. The heat transfer and pressure drop performance was then evaluated using steady-state tests with constant wall temperature boundary condition and for channel Reynolds number ranging from 2800 to 15,000. The lattices depicted a higher heat transfer compared with a smooth channel and both the heat transfer and pressure drop increased with a decrease in the porosity from L1 to L2. Steady-state conjugate numerical results revealed formation of prominent vortical structures in the inter-unit cell spaces, which diverted the flow toward the top end wall and created an asymmetric heat transfer between the two end walls. In conclusion, these lattice structures provided an augmented heat transfer while favorably redistributing the coolant within channel.

Engineering↗

Enhanced flow boiling heat transfer on chromium coated zircaloy-4 using cold spray technique for accident tolerant fuel (ATF) materials

Flow boiling heat transfer tests were conducted to evaluate the Critical Heat Flux (CHF) and Heat Transfer Coefficient (HTC) of conventional and accident tolerant fuel (ATF) cladding materials, i.e., bare Zircaloy-4 (Zr4), and Zircaloy-4 coated with Chromium using physical vapor deposition (PVD) (Zr4-Cr-PVD) and cold spray process (Zr4-Cr-CS), respectively. The tests were performed on a single heater rod with a uniform heat flux profile, at the atmospheric pressure, inlet temperature (24 °C) and mass flow rate (750 kg/m 2 s). HTC’s were increased by 5.2% and 3.3% on Zr4-Cr-CS compared to bare Zr4 and Zr4-Cr-PVD. Improved HTCwas attributed to the increased void fraction and high roughness (Ra = 532 nm) of the Zr4-Cr-CS. In detail, the micro-cavities, which act as bubble seeds, were entirely distributed on the Zr4-Cr-CS, and these micro-cavities generated smaller and faster bubbles, thus the void fraction increased by 10.9% compared to bare Zr4. HTC is improved by these smaller and faster bubbles which can remove heat from the heater rod surface more efficiently. To identify the exact location of CHF, the surface temperature profile was measured using advanced fiber-optic sensors which have high temporal/spatial resolution (distance between point to point: ~2.5 mm, frequency ~100 Hz). CHF occurred at 80–95% along the heated length and showed an 11.6% reduction on Zr4-Cr-CS compared to bare Zr4. We hypothesize the CHF reduction was caused by the lower wettability of the Zr4-Cr-CS which reduces the liquid supply to the surface, and vigorous bubble accumulation owing to high void fraction near the outlet, which results in early formation of the vapor film. During the post-CHF quenching phase, the rougher Zr4-Cr-CS showed larger cooling rates compared to the bare Zr4 and Zr4-Cr-PVD, preventing of oxidation by chromium layer. In conclusion, we demonstrate that the high roughness on the Zr4-Cr-CS increased the number of micro-cavities on the surface, resulting in 5.2% increase in HTC and improvement in the quenching heat transfer performance whereas CHF was 11.6% reduced compared to bare Zr4. Overall statistically there is little effect in the coating with regards to CHF and slight improvement in HTC.

42 ENGINEERING↗

Design of an Additively Manufactured Recuperator With 800 °C Inlet Temperature for sCO2 Power Cycle Application

Abstract Recuperators with design temperatures at and above 800 °C can further increase the thermal efficiency of supercritical CO2 power cycles by enabling higher turbine exhaust temperatures. Mar-M247 is a well-suited nickel-based superalloy for high temperature service due to its high creep strength that prevents excessive material thickness being required for pressure containment. Additive manufacturing using a high-speed laser-directed energy deposition (L-DED) process presents a promising solution, with build trials demonstrating the ability to produce nonconventional flow channels for enhanced heat transfer. A design process is presented that includes aerothermal and mechanical evaluation to maximize performance within the constraints of the manufacturing process. A 2-D heat transfer network and pressure drop code allows prediction of flow distribution and its effect on overall thermal performance. Established literature correlations, along with CFD simulation, inform the prediction of heat transfer coefficients and friction factors for the flowpaths and enhancement features in the heat exchanger core. Mechanical evaluation using finite element analysis (FEA) modeling with the intent of the ASME Boiler & Pressure Vessel Code (BPVC) Section VIII, Div. 2 assesses the operational safety of the design. The detailed design features annular finned passages that take advantage of helical flow paths to distribute the flow from separated headers to shared heat transfer surfaces. Performance predictions for the recuperator at a 50 kW scale provide insights into the feasibility of the additively manufactured (AM) process to produce recuperators on a commercial scale that extend existing operating envelopes.

Engineering↗

Toward Verification of RANS Simulations of the T-Tube Modular Divertor Using Large Eddy Simulations of Impinging Turbulent Plane Jets

Turbulent impinging jets have been proposed to cool high heat flux plasma-facing components such as the solid tungsten target plates of the divertor in long-pulse magnetic fusion energy reactors. In particular, the T-tube modular divertor, originally developed by the ARIES Team, consists of two concentric cylindrical tubes where helium flows through a slot in the inner tube, forming an approximately planar jet that impinges upon and cools the inner surface of the pressure boundary (namely, the outer tube) and the ~15-cm 2 plasma-facing W target. The objective of this work is to demonstrate that large eddy simulations (LESs) accurately simulate the thermal transport in canonical flows that comprise the cooling flow in the T-tube, as well as validate temperatures from LES with experimental measurements in a simplified T-tube geometry. Wall‑resolved LESs, validated by experimental data and verified by direct numerical simulations (DNSs), provide benchmark data for two canonical flows in the T‑tube, namely, planar impinging and wall jets, for Reynolds numbers Re B = 4 × 10 3 to 2 × 10 4 . Our LES results are within 4% to 12% root-mean-square error (RMSE) of surface Nusselt number distributions (Nu) from experiments and DNSs. The validated LES results are then used as the ground truth to evaluate four Reynolds‑averaged Navier-Stokes (RANS) turbulence closures, namely, the k‑ω SST, realizable k‑ε, GEKO, and γ‑SST models. The k‑ω SST model has the best overall performance in terms of heat transfer, giving surface Nu within 12% RMSE of the LES results for high‑ReB impinging jets and reduced overprediction in the wall‑jet region. The GEKO model with default constants has the next best performance, providing slightly better Nu predictions for low ReB impinging jets (versus k-ω SST) but worse overall performance over the full range of ReB studied here. The realizable k‑ε turbulence model significantly overestimates turbulence near the stagnation point, while the γ‑SST model suppresses near‑wall production, biasing the simulations toward simulating laminar surface heat transfer. Simulations of the simplified T‑tube show that LES and RANS simulations with the k‑ω SST model give nearly identical average heat transfer coefficients (HTCs) over the impingement surface. The realizable k‑ε model predicts significantly lower wall temperatures due to overestimation of HTC in the outlet flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

A Comparative Radiative Property Evaluation of Sintered Bauxite and AMS4003 Ceramic Particles

The radiative properties of sintered bauxite (ACCUCAST ID80) and AMS4003 particles were measured and compared to assess their performances as direct absorption and heat transfer media for particle-based concentrated solar power (CSP) plants. Reflectance measurements were performed over the spectral range 0.2–20 µm and used to calculate solar and thermal emission properties of the particles. In addition, reflectance was measured as a function of temperature up to 1000 °C for the spectral range 1–20 µm. The solar absorptance of AMS4003 was greater than that of ACCUCAST both before and after thermal cycling of the materials at 1000 °C, although thermal cycling was found to substantially decrease the solar absorptance of both materials. The thermal emittance of AMS4003 was also greater than that of ACCUCAST at all temperatures tested. Finally, the radiaitve properties measured in this study were used to estimate absorber efficiencies as a way to compare the particles in terms of their performance in a solar receiver. AMS4003 yielded greater efficiencies than ACCUCAST, suggesting its potential as a material for CSP.

14 SOLAR ENERGY↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

An economics-by-design approach to a radiant integrated thermophotovoltaic microreactor system

This paper presents an application of the economics-by-design approach to the Radiant Integrated Thermo-photovoltaic Microreactor System (RITMS). The RITMS design is unique in that it directly couples a critical fission reactor with thermo-photovoltaic (TPV) panels for high efficiency energy conversion. This significant shift from electric conversion using traditional dynamic heat pumps leads to a simpler and more reliable system without turbomachinery and high pressurization. In working towards wrapping up the early design work, the economics-by-design approach, which centers economic competitiveness as the optimization parameter, is well suited in making a final determination on viability. This paper describes the computational sequence that was developed to couple the radiative and conductive heat transfer and feed operational performance to cost estimation. The framework was applied to maximize the power of the system, while minimizing the fuel enrichment. This method is applied to a reference RITMS design as part of a parametric sensitivity study, which revealed that the system is under moderated and that single unit plants could produce power as low as 300 dollar/MWh. This price point supports the notion that early in the RITMS design implementation, adoption into niche markets as a first-of-a-kind technology is possible. (authors)