Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multifunctional intensified reactor device with integrated heat and mass transfer

A packing device for mass and heat transfer with a subject fluid includes a housing having opposing ends, and subject fluid openings at each opposing end defining a subject fluid flow path for at least one subject fluid flowing through the packing device. A plurality of mass and heat transfer plates each include an interior heat exchange fluid channel disposed between interior heat transfer surfaces of the mass and heat transfer plates. A heat exchange fluid inlet and fluid outlet can supply and remove heat exchange fluid to the heat exchange fluid channels of the mass and heat transfer plates. The mass and heat transfer plates can be oriented to define there between fluid flow channels for the subject fluid. A method and system for mass and heat transfer with a subject fluid, and a method and system for the removal of CO2 from a gas stream are disclosed.

Lai, Canhai↗

Integrating Waste Heat from CO 2 Removal and Coal-Fired Flue Gas to Increase Plant Efficiency

In project DE-FE0007525, Southern Company Services demonstrated heat integration methods for the capture and sequestration of carbon dioxide produced from pulverized coal combustion. A waste heat recovery technology (termed High Efficiency System) from Mitsubishi Heavy Industries America was integrated into an existing 25-MW amine-based CO 2 capture process (Kansai Mitsubishi Carbon Dioxide Recovery Process®1) at Southern Company’s Plant Barry to evaluate improvements in the energy performance of the pulverized coal plant and CO 2 capture process. The heat integration system consists of two primary pieces of equipment: (1) the CO 2 Cooler which uses product CO 2 gas from the capture process to heat boiler condensate, and (2) the Flue Gas Cooler which uses air heater outlet flue gas to further heat boiler condensate. Both pieces of equipment were included in the pilot system. The pilot CO 2 Cooler used waste heat from the 25-MW CO 2 capture plant (but not always from product CO 2 gas, as intended). The pilot Flue Gas Cooler used heat from a slipstream of flue gas taken from downstream of Plant Barry’s air heater. The pilot also included a 0.25-MW electrostatic precipitator. The 25-MW High Efficiency System operated for approximately six weeks over a four month time period in conjunction with the 25-MW CO 2 capture facility at Plant Barry. Results from the program were used to evaluate the technical and economic feasibility of full-scale implementation of this technology. The test program quantified energy efficiency improvements to a host power plant that could be realized due to the High Efficiency System. Through the execution of this project, the team verified the integrated operation of the High Efficiency System and Kansai Mitsubishi Carbon Dioxide Recovery Process®. The ancillary benefits of the High Efficiency System were also quantified, including reduced water consumption, a decrease in toxic air emissions, and better overall air quality control systems performance.

20 FOSSIL-FUELED POWER PLANTS↗

Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

dehumidification↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗

Integrated process of distillation with side reactors for synthesis of organic acid esters

An integrated process and system for synthesis of organic-acid esters is provided. The method of synthesizing combines reaction and distillation where an organic acid and alcohol composition are passed through a distillation chamber having a plurality of zones. Side reactors are used for drawing off portions of the composition and then recycling them to the distillation column for further purification. Water is removed from a pre-reactor prior to insertion into the distillation column. An integrated heat integration system is contained within the distillation column for further purification and optimizing efficiency in the obtaining of the final product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Carbon Capture Retrofits for Cement Plants

The objective of this study is to provide an estimate of the cost to capture CO 2 in retrofit applications at cement plants. The cement plant configurations considered in this study include natural gas and solid fuel (coal and coke) cases, and both wet- and dry kiln-fed plant designs, however the base cement plants in this study were not evaluated other than characterization of their kiln off-gas stream and high-level quantification of heat integration potential at the existing plant. In each case, the base cement plant produces 1.5 M tonnes per year of finished cement, assuming 91.4 percent clinker content. This analysis includes a 10 percent retrofit cost increase for process integration and low grade heat recovery, when compared to the analogous non-heat integration case. Heat integration is considered as a potential offset to capture system heating demands (i.e., as a percentage reduction). Recovery and reuse of excess heat from the base cement plant can provide economic benefits—primarily by reducing the need to purchase supplemental natural gas for CO 2 solvent regeneration—but any process improvement must be great enough to overcome the cost increases (i.e., capital and O&M) necessary to realize those benefits. With heat integration potential of 10 percent and 30 percent, that benefit wasn’t significant enough to offset the increase in capital and operating costs, and a cost of capture increase was observed based on the assumptions in this report. Benefits of heat integration potential may be realized when natural gas prices are higher, as demonstrated in the sensitivity to natural gas price where crossover points exist between heat integration cases and their respective non-heat integration cases. Four of the base cases were further evaluated to explore the cost implications of deeper levels of gas pre-treatment to remove oxides of nitrogen (NOx) and oxides of sulfur (SOx) from the kiln off-gas stream prior to CO 2 capture, purification, and compression. The results of these additional case analyses showed a 7.4–18.8 percent increase in cost of capture over the respective base case (i.e., analogous cases without SOx/NOx removal).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Modeling of a Solar-To-Hydrogen Flexible High Temperature Steam Electrolysis Plant

Sustainble hydrogen production for use as a renewable combustible fuel and clean chemical feedstock is an important objective as the world moves towards a renewable energy future. High temperature steam electrolysis is a promising hydrogen production technology due to its reduced electric input that is offset by heat input into steam generation and steam superheating. An option to provide this heat is to use concentrating solar thermal technology that can sustainably provide heat input while renewable electricity is used for the electrolysis reaction. In this work, a solar-to-hydrogen high temperature steam electrolysis plant is designed and dynamically modeled, showing continuous hydrogen production by utilizing supplemental heating and efficient recuperative heating from the electrolysis product streams. Through this design, over 90% of the required heat input for the process can by met by a combination of solar and recuperative heat. Additionally, the plant can flexibility operate by ramping down hydrogen production and through flexible heat integration, which intelligently integrates solar heat based on solar conditions. Smooth operation with flexible hydrogen production is demonstrated which decreases electrical input during on-peak grid times and also decreases the total supplemental heat load over the course of a day from 26.1% to 24.5%. In addition, by using flexible heat integration, the plant can increase its solar heat usage by 4.1% relative to a base case. Both options for flexibility show efficient use of solar thermal energy to sustainably and continuously produce hydrogen.

Immonen, Jake (ORCID:0000000341231625)↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Minimum Energy of Multicomponent Distillation Systems Using Minimum Additional Heat and Mass Integration Sections

Heat and mass integration to consolidate distillation columns in a multicomponent distillation configuration can lead to a number of new energy efficient and cost effective configurations. In this paper, we identify a powerful and simple-to-use fact about heat and mass integration. The newly developed heat and mass integrated configurations, which we call as HMP configurations, involve first introducing thermal couplings to all intermediate transfer streams, followed by consolidating columns associated with a lighter pure product reboiler and a heavier pure product condenser. A systematic method of enumerating all HMP configurations is introduced. We compare the energy savings of HMP configurations with the well-known fully thermally coupled (FTC) configurations. We demonstrate that HMP configurations can have very similar and sometimes even the same minimum total vapor duty requirement as the FTC configuration, while using far less number of column sections, intermediate transfer streams, and thermal couplings than the FTC configurations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Earth return aerocapture for manned Mars missions

Lift to drag ratio (L/D) requirements and stagnation point heating have been examined for a variety of probable entry conditions and vehicle configurations. It is found that vehicles with an L/D of 0.5 or more provide a corridor width of at least 0.7 degrees while keeping the peak deceleration load below 5 g for approach velocities up to 14.5 km/s. It is shown that stagnation point peak heating rates and integrated heat load critically depend on both entry velocity and ballistic coefficient. For the most severe cases under consideration, peak heating and integrated heat load are five times greater than those encountered by Apollo but within the range of experience for unmanned vehicles.

Tauber, M. E.↗

A Preliminary Study of a Novel Heat Pump Integrated Underground Thermal Energy Storage for Shaping Electric Demand of Buildings

A Dual-Purpose Underground Thermal Battery (DPUTB) innovatively integrates a ground heat exchanger with underground thermal energy storage. The DPUTB can be integrated with an Electric-Driven Heat Pump (EDHP) to enable more flexible electric load for meeting the thermal demands of a building (e.g., space cooling and space heating). A one-dimensional numerical model of the DPUTB is developed and validated against measured performance data of a small-scale DPUTB prototype. The validated DPUTB model is integrated with a heat pump model and a building energy simulation model to predict the load shifting performance and energy consumption of an integrated EDHP and DPUTB system. Preliminary simulation results indicate that the integrated system can flatten the electric load profile of a typical residential building and reduce the electric demand during peak hours by 37% on a typical summer day. In addition, the integrated EDHP and DPUTB system also reduces the daily power consumption of the building by 11% compared with a conventional residential space heating and cooling system.

Liu, Xiaobing↗