Thermal energy storage and transport

The extraction of thermal energy from large LWR and coal fired plants for long distance transport to industrial and residential/commercial users is analyzed. Transport of thermal energy as high temperature water is shown to be considerably cheaper than transport as steam, hot oil, or molten salt over a wide temperature range. The delivered heat is competitive with user-generated heat from oil, coal, or electrode boilers at distances well over 50 km when the pipeline operates at high capacity factor. Results indicate that thermal energy storage makes meeting of even very low capacity factor heat demands economic and feasible and gives the utility flexibility to meet coincident electricity and heat demands effectively.

Hausz, W.↗

A Heated Tube Facility for Rocket Coolant Channel Research

The capabilities of a heated tube facility used for testing rocket engine coolant channels at the NASA Lewis Research Center are presented. The facility uses high current, low voltage power supplies to resistively heat a test section to outer wall temperatures as high as 730 C (1350 F). Liquid or gaseous nitrogen, gaseous helium, or combustible liquids can be used as the test section coolant. The test section is enclosed in a vacuum chamber to minimize heat loss to the surrounding system. Test section geometry, size, and material; coolant properties; and heating levels can be varied to generate heat transfer and coolant performance data bases.

Green, James M.↗

Electric Aircraft Thermal Management Using a Two-Phase Heat Transport System with Solid-State Thermal Switching Capability

Advanced Cooling Technologies, Inc. (ACT) is collaborating with NASA Glenn Research Center (GRC) to develop a heat pipe-based thermal delivery system to efficiently manage the waste heat generated onboard an electric aircraft. The heat pipe system will interface with NASA GRC’s thermoacoustic heat pump in order to recycle waste heat by transporting thermal energy to various end users onboard the aircraft. This paper discusses the layout of theoretical heat pipe networks for a MW-class commercial electric aircraft. This is followed by a discussion of progress made on the development of a novel two-phase heat transport system with solid-state thermal switching and control capabilities.

Exergy↗

Subcritical convective instability. II.

Subcritical convective instability, discussing effects of internal heat generation and spatial variation of gravity field on onset of thermal convection

SPATIAL DISTRIBUTION↗

Comparative Soot Diagnostics Experiment Looks at the Smoky World of Microgravity Combustion

From an economic standpoint, soot is one of the most important combustion intermediates and products. It is a major industrial product and is the dominant medium for radiant heat transport in most flames used to generate heat and power. The nonbuoyant structure of most flames of practical interest (turbulent flames) makes the understanding of soot processes in microgravity flames important to our ability to predict fire behavior on Earth. In addition, fires in spacecraft are considered a credible possibility. To respond to this risk, NASA has flown fire (or smoke) detectors on Skylab and the space shuttles and included them in the International Space Station design. The design of these detectors, however, was based entirely on normal gravity (1g) data. The detector used in the shuttle fleet is an ionization detector, whereas the system planned for the space station uses forward scattering of near-infrared light. The ionization detector, which is similar to smoke detectors used in homes, has a comparative advantage for submicron particulates. In fact, the space shuttle model uses a separation system that makes it blind to particles larger than a micron (believed to be dust). In the larger size range, the lightscattering detector is most sensitive. Without microgravity smoke data, the difference in the particle size sensitivities of the two detectors cannot be evaluated. As part of the Comparative Soot Diagnostics (CSD) experiment, these systems were tested to determine their response to particulates generated during long periods of low gravity. This experiment provided the first such measurements toward understanding soot processes on Earth and for designing and implementing improved spacecraft smoke detection systems. The objectives of CSD were to examine how particulates form from a variety of sources and to quantify the performance of several diagnostic techniques. The sources tested included four overheated materials (paper, silicone rubber, Teflon-coated (DuPont) wire, and Kapton-coated (DuPont) wires), each tested at three heating rates, and a candle tested at three air velocities. Paper, silicone rubber, and wire insulation, materials found in spacecraft crew cabins, were selected because of their different smoke properties. The candle yielded hydrocarbon soot typical of many 1g flames. Four diagnostic techniques were employed: thermophoretic sampling collected particulates for size analysis; laser light extinction measurements near the source tallied total particulate production; and laser light scattering and ionization detector measurements far from the particulate source provided data for evaluating the performance of smoke detection systems for these particulate sources.

Urban, David L.↗

Tribological evaluation of PS300: A new chrome oxide based solid lubricant coating sliding against Al2O3 From 25 to 650 C

This paper presents the tribological characteristics of Al203 sliding against PS300; a chrome oxide based self lubricating coating. Al203 pins were slid against PS300 coated superalloy disks in air, under a 4.9 N load at velocities of 1 to 8 m/s. At a sliding velocity of 1 m/s, friction ranged from 0.6 at 25 C to 0.2 at 650 C. Wear factors for the Al203 pins were in the 10(exp -7) mm(exp 3)/N-m range and for the PS300 coating was in the 10(exp -5) mm(exp 3)/N-m range. The test results suggest that increased surface temperature resulting from either frictional heating, generated by increased sliding velocity, or ambient heating caused a reduction in friction and wear of the sliding couple. Based upon these results, the tested material combination is a promising candidate for high temperature wear applications.

DellaCorte, C.↗

Analysis of Turbulent Flow and Heat Transfer in Noncircular Passages

Previous work on turbulent heat transfer and flow in tubes was generalized and applied to flow in non-circular passages of equilateral triangular and square cross section. Expressions for eddy diffusivity that had been verified for flow and heat transfer in tubes were assumed to apply in general along lines normal to a wall. Velocity distributions, wall shear-stress distributions, and friction factors, as well as wall heat-transfer distributions, wall temperature distributions, and average heat-transfer coefficients were calculated. In addition, results from a previous analysis for axial flow between rods were compared with new experimental data. For calculating wall temperature distributions, uniform heat generation in the passage wall and uniform heat transfer at the outer surface were assumed. The application of the results is restricted to moderately small peripheral wall temperature variations. Calculations were made for Reynolds numbers from 20,000 to 900,000 and Prandtl numbers from 0.73 to 300. Results show that velocities, shear stresses, and heat transfer in the region near the corner were lower than average values and were zero at the corner. Friction factors and average Nusselt numbers were lower than in a tube.

Taylor, Maynard F.↗

Computational Evaluation of an OML-based Heat Exchanger Concept for HEATheR

Feasibility of outer mold line (OML) heat exchangers for electrified aircraft is computationally explored for three different aircraft concepts within The High-efficiency Electrified Aircraft Thermal Research (HEATheR) project. OML surface temperature limits were selected based on aluminum-alloy and carbon-fiber composite materials commonly used in transport aircraft. Heat flux distribution over the aircraft OML at the surface temperature limit was evaluated with computational fluid dynamics (CFD) analysis. The candidate OML locations and the size for the implementation of the OML-based heat exchanger is down-selected using this initial analysis and other considerations including the concern for structural integrity and proximity to heat-generating electrical components. The sensitivity of the heat transfer analysis to the computational grid, aircraft angle of attack, surface temperature, and the interaction of individual OML heat exchanger patches were investigated.

CAS↗

Thermal Performance of ATLAS Laser Thermal Control System Demonstration Unit

The second Ice, Cloud, and Land Elevation Satellite mission currently planned by National Aeronautics and Space Administration will measure global ice topography and canopy height using the Advanced Topographic Laser Altimeter System {ATLAS). The ATLAS comprises two lasers; but only one will be used at a time. Each laser will generate between 125 watts and 250 watts of heat, and each laser has its own optimal operating temperature that must be maintained within plus or minus 1 degree Centigrade accuracy by the Laser Thermal Control System (LTCS) consisting of a constant conductance heat pipe (CCHP), a loop heat pipe (LHP) and a radiator. The heat generated by the laser is acquired by the CCHP and transferred to the LHP, which delivers the heat to the radiator for ultimate rejection. The radiator can be exposed to temperatures between minus 71 degrees Centigrade and minus 93 degrees Centigrade. The two lasers can have different operating temperatures varying between plus 15 degrees Centigrade and plus 30 degrees Centigrade, and their operating temperatures are not known while the LTCS is being designed and built. Major challenges of the LTCS include: 1) A single thermal control system must maintain the ATLAS at 15 degrees Centigrade with 250 watts heat load and minus 71 degrees Centigrade radiator sink temperature, and maintain the ATLAS at plus 30 degrees Centigrade with 125 watts heat load and minus 93 degrees Centigrade radiator sink temperature. Furthermore, the LTCS must be qualification tested to maintain the ATLAS between plus 10 degrees Centigrade and plus 35 degrees Centigrade. 2) The LTCS must be shut down to ensure that the ATLAS can be maintained above its lowest desirable temperature of minus 2 degrees Centigrade during the survival mode. No software control algorithm for LTCS can be activated during survival and only thermostats can be used. 3) The radiator must be kept above minus 65 degrees Centigrade to prevent ammonia from freezing using no more than 135 watts of heater power. 4) The LHP reservoir control heater power is limited to 15 watts with a 70 percent duty cycle. 5) The voltage of the power supply can vary between 26 volts direct current and 34 volts direct current during the spacecraft lifetime. A design analysis shows that a single LTCS can satisfy these requirements. However, shutdown of· the LHP is particularly challenging and the shutdown heater must be wired in series with two reservoir thermostats and two CCHP thermostats at different set points. An LTCS demonstration unit has been tested to verify these performance characteristics experimentally prior to proceeding to the final LTCS design and fabrication. Test results showed that the LHP shutdown scheme would be able to shut down the LHP as designed and the reservoir control heater can maintain the ATLAS mass simulator within the plus or minus 1 degrees Centigrade accuracy under various combinations of the heat load, sink temperature, and power supply voltage.

Ku, Jentung↗

Electrostatically controlled heat shutter

Electrically controlled chamber filled with inert gas efficiently removes heat from heat-generating components. System can be reversed to bring heat from external source to component.

Derr, L. J.↗

Experimental determination of stator endwall heat transfer

Local Stanton numbers were experimentally determined for the endwall surface of a turbine vane passage. A six vane linear cascade having vanes with an axial chord of 13.81 cm was used. Results were obtained for Reynolds numbers based on inlet velocity and axial chord between 73,000 and 495,000. The test section was connected to a low pressure exhaust system. Ambient air was drawn into the test section, inlet velocity was controlled up to a maximum of 59.4 m/sec. The effect of the inlet boundary layer thickness on the endwall heat transfer was determined for a range of test section flow rates. The liquid crystal measurement technique was used to measure heat transfer. Endwall heat transfer was determined by applying electrical power to a foil heater attached to the cascade endwall. The temperature at which the liquid crystal exhibited a specific color was known from a calibration test. Lines showing this specific color were isotherms, and because of uniform heat generation they were also lines of nearly constant heat transfer. Endwall static pressures were measured, along with surveys of total pressure and flow angles at the inlet and exit of the cascade.

Boyle, Robert J.↗

Experimental determination of stator endwall heat transfer

Local Stanton numbers were experimentally determined for the endwall surface of a turbine vane possage. A six vane linear cascade having vanes with an axial chord of 13.81 cm was used. Resutls were obtained for Reynolds numbers based on inlet velocity and axial chord between 75,000 and 495,000. The test section was connected to a low pressure exhaust system. Ambient air was drawn into the test section, inlet velocity was controlled up to a maximum of 59.4 m/sec. The effect of the inlet boundary layer thickness on the endwall heat transfer was determined for a range of test section flow rates. The liquid crystal measurement technique was used to measure heat transfer. Endwall heat transfer was determined by applying electrical power to a foil heater attached to the cascade endwall. The temperature at which the liquid crystal exhibited a specific color was known from a calibration test. Lines showing this specific color were isotherms, and because of uniform heat generation they were also lines of nearly constant heat transfer. Endwall static pressures were measured, along with surveys of total pressure and flow angles at the inlet and exit of the cascade.

Boyle, Robert J.↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

Validating cell/battery safety

Using the accelerating rate calorimeter, the hazards associated with exothermic reactions occurring in Li/SO2 cells under the conditions of discharge, forced overdischarge, resistive overdischarge, and forced overdischarge at low tempratures are quantitatively defined in terms of: rate of pressure generation, overall pressure rise, rate of temperature, and overall heat generation. Consistent with the findings of other investigators, it is believed that the major reactions contributing to Li/SO2 cell exothermicity are: the lithium/acetonitrile reaction, the thermal decomposition of lithium dithionite, and the lithium/sulfur reaction.

Chua, D.↗

Thermal properties and effects for Li/BCX (thionyl chloride) cells

New NASA requirements for the screening of lithium cells for space applications involve thermal soaks at elevated temperatures (149 C). The currently qualified Li/BCX cells and three design modifications have been evaluated showing that a design incorporating a shortened electrode stack met this test condition while continuing to satisfy the performance and safety requirements for cells used on NASA manned space vehicles. Information was also developed to show that measured heat capacities for the BCX D size cells correlated well with the heat generated from cells discharged in an insulated environment. Calculated heat capacities based on the amounts and types of materials in a cell were low compared to these values. This information provides the basis for the design of battery packs in the highly insulating environment of outer space.

Takeuchi, E. S.↗

Isothermal Calorimeter

Pressure-feedback signal indicates rate of heating. Improved isothermal calorimeter measures rate of heating in object under test. Called "isothermal" because chamber holding object and its environment maintained at or near constant temperature to minimize spurious tranfers of heat introducing errors into measurements. When item under test generates heat, rate of boiling and pressure in inner chamber increase. Servo-valve opens wider to maintain preset differential pressure. Valve-control voltage used as measure of rate of heating.

Rowlette, John J.↗