Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Hollow lattice thermal energy storage heat exchanger

Example heat exchangers and methods of use are described herein. An example heat exchanger includes a lattice structure including a plurality of conduits defining a plurality of interstitial voids between the plurality of conduits. Each of the plurality of conduits includes an inlet and an outlet, and the plurality of conduits are arranged such that, between the inlet and the outlet, each of the conduits intersects at least one other conduit to enable flow between the intersecting conduits. The example heat exchanger also includes a first manifold formed unitarily with the lattice structure, the first manifold comprising a first plurality of openings in fluid communication with each inlet of the plurality of conduits. The example heat exchanger further includes a phase change material (PCM) disposed within and substantially filling the plurality of interstitial voids.

Stoia, Michael F.↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

Solar-assisted gas-energy water-heating feasibility for apartments

Studies of residential energy use, solar-energy technology for buildings, and the requirements for implementing technology in the housing industry led to a project to develop a solar water heater for apartments. A design study for a specific apartment was used to establish a solar water-heater cost model which is based on plumbing contractor bids and manufacturer estimates. The cost model was used to size the system to minimize the annualized cost of hot water. The annualized cost of solar-assisted gas-energy water heating is found to be less expensive than electric water heating but more expensive than gas water heating. The feasibility of a natural gas utility supplying the auxiliary fuel is evaluated. It is estimated that gas-utilizing companies will find it profitable to offer solar water heating as part of a total energy service option or on a lease basis when the price of new base-load supplies of natural gas reaches $2.50-$3.00 per million Btu.

Davis, E. S.↗

The updated algorithm of the Energy Consumption Program (ECP): A computer model simulating heating and cooling energy loads in buildings

The energy Comsumption Computer Program was developed to simulate building heating and cooling loads and compute thermal and electric energy consumption and cost. This article reports on the new additional algorithms and modifications made in an effort to widen the areas of application. The program structure was rewritten accordingly to refine and advance the building model and to further reduce the processing time and cost. The program is noted for its very low cost and ease of use compared to other available codes. The accuracy of computations is not sacrificed however, since the results are expected to lie within + or - 10% of actual energy meter readings.

Lansing, F. L.↗

An Alternative Inter-Satellite Calibration of the UMD HIRS OLR Retrievals

Outgoing Longwave Radiation (OLR) at the top-of-atmosphere (TOA) is a fundamental component of Earth's energy balance and represents the heat energy in the thermal bands rejected to space by the planet. Determination of OLR from satellites has a long and storied history, but the observational record remains largely fragmented with gaps in satellite measurements over the past three decades. Perhaps the most semi-continuous set of retrievals comes from the University of Maryland (UMD) algorithm that uses four HIRS (High Resolution Infrared Sounder) channels on the NOAA polar orbiting satellites to estimate OLR. This data set shows great promise in helping to bridge the discontinuous ERBS (Earth Radiation Budget Satellite) and CERES (Clouds and the Earth s Radiant Energy System) measurements. However, significant satellite inter-calibration biases persist with the present UMD data, principally outside the tropics. Difficulties relate to the combination of drift of the satellite equator crossing time through the diurnal cycle and changes in HIRS channel response function design. Here we show how an ad hoc recalibration of the UMD retrievals among the different satellites removes much of the remaining uncertainty due to diurnal drift of the satellite orbit. The adjusted HIRS data (using no other external information) show much better agreement with OLR from the European Center Interim Reanalysis (EC-Int), longer-term signals in the Global Energy and Water Cycle Experiment / Surface Radiation Budget (GEWEX/SRB) retrievals, and also agree well with ERBS and CERES OLR measurements. These results augur well for narrowing the uncertainties in multi-decadal estimates of this important climate variable.

Robertson, Franklin R.↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy for solar heating and cooling in buildings

The types of solar energy heating and cooling equipment for use with buildings are discussed. The steps from manufacturing to equipment installation are identified. A feasibility study for the use of solar energy was conducted. The study determined the technical, environmental, economic, sociological, political, and strategic aspects of solar heating and cooling.

Source record↗

KCl-UCl 3 molten salts investigated by Ab Initio Molecular Dynamics (AIMD) simulations

Ab Initio Molecular Dynamics (AIMD) simulations are performed on molten KCl-UCl3 salt mixtures to determine energies, heat capacities, and densities. The density-dependent energy correction (DFT-dDsC), Grimme et al.'s DFT-D3, and Langreth & Lundqvist (vdW-cx) models are used for dispersion forces and combined with the Perdew-Burke-Ernzerhof (PBE) exchange-correlation potential with a Hubbard U parameter for the 5f electrons of uranium. After validating predictions for the end-member systems to literature data, KCl-UCl 3 mixtures are studied at select temperatures. Densities and energies both deviate from ideal solution behavior, with the maximum deviation occurring around 36% UCl 3 for mixing energies and slightly lower (29% UCl3) for densities. Compared to the NaCl-UCl 3 system, which was previously investigated using the same simulation methodologies, the KCl-UCl 3 density and mixing energy deviations from ideal solution behavior are larger by almost a factor of two. No deviation from ideal solution behavior for heat capacity was observed. The AIMD predictions for mixing energies and densities agree qualitatively with experimental data, though the spread in data obtained from the various dispersion force models utilized, measurements, and empirical estimates makes strong conclusions difficult. The dependence of thermodynamic and thermophysical properties on composition is correlated with the local chemistry of the solution phase, in particular, the tendency of UCl 3 to form network structures.

36 MATERIALS SCIENCE↗

KCl-UCl 3 molten salts investigated by Ab Initio Molecular Dynamics (AIMD) simulations: A comparative study with three dispersion models

Ab Initio Molecular Dynamics (AIMD) simulations are performed on molten KCl-UCl 3 salt mixtures to determine energies, heat capacities, and densities. The density-dependent energy correction (DFT-dDsC), Grimme et al.’s DFT-D3, and Langreth & Lundqvist (vdW-cx) models are used for dispersion forces and combined with the Perdew-Burke-Ernzerhof (PBE) exchange-correlation potential with a Hubbard U param eter for the 5$f$ electrons of uranium. After validating predictions for the end-member systems to literature data, KCl-UCl 3 mixtures are studied at select temperatures. Densities and energies both deviate from ideal solution behavior, with the maximum deviation occurring around 36% UCl 3 for mixing energies and slightly lower (29% UCl 3 ) for densities. Compared to the NaCl-UCl 3 system, which was previously investigated using the same simulation methodologies, the KCl-UCl 3 density and mixing energy deviations from ideal solution behavior are larger by almost a factor of two. No deviation from ideal solution behavior for heat capacity was observed. The AIMD predictions for mixing energies and densities agree qualitatively with experimental data, though the spread in data obtained from the various dispersion force models utilized, measurements, and empirical estimates makes strong conclusions difficult. The dependence of thermodynamic and thermophysical properties on composition is correlated with the local chemistry of the solution phase, in particular, the tendency of UCl 3 to form network structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Evolution of thermo-mechanical properties of concrete with calcium aluminate cement and special aggregates for energy storage

Highlights: • CAC Concrete with stable aggregates is suitable for high temperatures with cycles. • Concrete suffered performance changes after the first thermal cycle (dehydration). • Subsequent thermal cycles showed stabilization and slight performance decreases. With the ever-expanding presence of solar energy, the design of cost-efficient heat energy storage systems is becoming increasingly relevant. Concrete is a potential solid material for these systems but raises questions of its response at high temperatures in operating conditions. This work studies concrete designed with calcium aluminate cement and three types of aggregates that are stable at high temperatures. The designed concrete mixes were exposed to thermal cycles (290–550 °C), and their thermal fatigue response was evaluated with mechanical, cracking, thermal, and microstructural analyses at room temperature after heat cycles. The obtained results show that the main changes are mostly produced after the first thermal cycle and are stabilized during successive thermal cycles, with only a slight decrease in the thermo-mechanical properties. The results showed stabilization of cracking, crack widths between 10 and 80 μm, reduction of compressive strength, around 50–65%, and reduction of the thermal conductivity by 30%.

36 MATERIALS SCIENCE↗

Analysis of Thermoradiative Thermal Energy Conversion

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is a p-n junction semiconductor device, similar to a photovoltaic cell but thermodynamically operating in the reverse direction, converting the thermal dark current into electrical power while radiating waste heat to space. The power and efficiency can be calculated as a function of bandgap in the Shockley-Queisser detailed-balance limit, in which the thermal emissivity of the cell is due to the recombination of electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation. The fundamental loss mechanism for the thermoradiative cell is the energy carried by the infrared radiation into space from band-to-band recombination of carriers injected across the junction. In an ideal cell, to maximize the efficiency, the emission energy of these photons would precisely equal the bandgap. This can be achieved, for example, using dielectric filters or meta-material filters to recycle emission at other wavelengths back into the cell. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Unlike in photovoltaic cells, non-radiative recombination (e.g., Auger losses) will reduce the output current, but will not reduce the conversion efficiency, since the recombination energy is retained in the cell in the form of heat. Since a thermoradiative cell operates by radiating directly to space, the current produced by themoradiative cells will increase as Stefan-Boltzmann radiation; roughly the fourth power of the temperature. Thus, the power produced is highest at high operating temperatures, and, unlike conventional thermal conversion, increasing radiator temperature increases, the efficiency. Thus, the choice of technology will be toward semiconductors resistant to degradation at high temperature.

Thermoradiative↗

Heating and acceleration of ions with Kappa distribution functions by low‐frequency Alfvén wave

Abstract Heating and acceleration of ions with Kappa distribution functions (with parameter ) in low‐beta plasmas, by a low‐frequency Alfvén wave, is investigated using test‐particle simulations, yielding interesting new results. As long as the Alfvén wave amplitude is sufficiently large, the computed net heating energy of ions becomes independent of the wave frequency and amplitude, always approaching the same value of . The eventual energy of ions is dictated only by the initial ion energy and the ratio of the magnetic field energy density to the plasma density. The heating effect of the Kappa ions increases with . During the heating process, the ions are picked up by the Alfvén wave and pitch angle scattered, forming a quasi‐isotropic spherical shell velocity distribution. The Kappa ions are accelerated in the parallel direction, reaching a bulk flow speed roughly equal to the local Alfvén speed. Higher ‐value in the initial Kappa distribution leads to faster saturation. The above results may explain certain features of the ion heating and acceleration in the solar wind and corona.

Li, Kehua↗

Thermal insulation versus capacitance: A simulation experiment comparing effects of shade and hyporheic exchange on daily and seasonal stream temperature cycles

In streams where water temperatures stress native biota, management of riparian shade or hyporheic exchange are both considered viable management strategies for reducing the peaks of daily and seasonal stream channel temperature cycles. Although shade and hyporheic exchange may have similar effects on stream temperatures, their mechanisms differ. Improved understanding of the heat-exchange mechanisms influenced by shade and hyporheic exchange will aid in the appropriate application of either stream temperature management strategy. To illustrate a conceptual model highlighting shade as ‘thermal insulation’ and hyporheic exchange imparting ‘thermal capacitance’ to a stream reach, we conducted an in-silico simulation modelling experiment increasing shade or hyporheic exchange parameters on an idealized, hypothetical stream. We assessed the potential effects of increasing shade or hyporheic exchange on a stream reach using an established process-based heat-energy budget model of stream-atmosphere heat exchange and incorporated an advection-driven hyporheic heat exchange routine. The model tracked heat transport through the hyporheic zone and exchange with the stream channel, while including the effects of hyporheic water age distribution on upwelling hyporheic temperatures. Results showed that shade and hyporheic exchange similarly damped diurnal temperature cycles and differentially altered seasonal cycles of our theoretical stream. In winter, hyporheic exchange warmed simulated channel temperatures whereas shade had little effect. In summer, both shade and hyporheic exchange cooled channel temperatures, though the effects of shade were more pronounced. Our simple-to-grasp analogies of ‘thermal insulation’ for shade effects and ‘thermal capacitance’ for hyporheic exchange effects on stream temperature encourage more accurate conceptualization of complex, dynamic heat exchange processes among the atmosphere, stream channel, and alluvial aquifer.

54 ENVIRONMENTAL SCIENCES↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Parametric Analysis of Cyclic Phase Change and Energy Storage in Solar Heat Receivers

A parametric study on cyclic melting and freezing of an encapsulated phase change material (PCM), integrated into a solar heat receiver, has been performed. The cyclic nature of the present melt/freeze problem is relevant to latent heat thermal energy storage (LHTES) systems used to power solar Brayton engines in microgravity environments. Specifically, a physical and numerical model of the solar heat receiver component of NASA Lewis Research Center's Ground Test Demonstration (GTD) project was developed. Multi-conjugate effects such as the convective fluid flow of a low-Prandtl-number fluid, coupled with thermal conduction in the phase change material, containment tube and working fluid conduit were accounted for in the model. A single-band thermal radiation model was also included to quantify reradiative energy exchange inside the receiver and losses through the aperture. The eutectic LiF-CaF2 was used as the phase change material (PCM) and a mixture of He/Xe was used as the working fluid coolant. A modified version of the computer code HOTTube was used to generate results in the two-phase regime. Results indicate that parametric changes in receiver gas inlet temperature and receiver heat input effects higher sensitivity to changes in receiver gas exit temperatures.

Hall, Carsie A., III↗

Modeling Cyclic Phase Change and Energy Storage in Solar Heat Receivers

Numerical results pertaining to cyclic melting and freezing of an encapsulated phase change material (PCM), integrated into a solar heat receiver, have been reported. The cyclic nature of the present melt/freeze problem is relevant to latent heat thermal energy storage (LHTES) systems used to power solar Brayton engines in microgravity environments. Specifically, a physical and numerical model of the solar heat receiver component of NASA Lewis Research Center's Ground Test Demonstration (GTD) project was developed and results compared with available experimental data. Multi-conjugate effects such as the convective fluid flow of a low-Prandtl-number fluid, coupled with thermal conduction in the phase change material, containment tube and working fluid conduit were accounted for in the model. A single-band thermal radiation model was also included to quantify reradiative energy exchange inside the receiver and losses through the aperture. The eutectic LiF-CaF2 was used as the phase change material (PCM) and a mixture of He/Xe was used as the working fluid coolant. A modified version of the computer code HOTTube was used to generate results for comparisons with GTD data for both the subcooled and two-phase regimes. While qualitative trends were in close agreement for the balanced orbit modes, excellent quantitative agreement was observed for steady-state modes.

Hall, Carsie A., III↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗