Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Convectively Induced Secondary Circulations and Wind‐Driven Heat Fluxes in the Surface Energy Balance Over Land

Increased resolution has enabled kilometer-scale weather and climate models to partially resolve secondary circulations, including horizontal convective rolls (HCRs) and cold pool gust fronts. Although these circulations are ubiquitous in convective boundary layers over land, their impacts on the surface energy balance are largely unknown. Doppler lidar and surface observations were combined with DOE E3SM land model experiments, revealing increased surface winds (5 m/s) and heat fluxes (50 W/m 2 ) in convergent branches of HCRs. Larger wind-driven flux responses (up to 150 W/m 2 ) were found along gust fronts. Surface energy balance shifts to accommodate wind-driven fluxes, reducing ground heat conduction and longwave cooling. Our findings from the US Southern Great Plains are broadly relevant to modeling convective boundary layers. In particular, widely used subgrid wind gust parameterizations were found to be physically inconsistent with resolved secondary circulations and could worsen climate prediction biases at kilometer-scales.

54 ENVIRONMENTAL SCIENCES↗

Divertor heat flux challenge and mitigation in SPARC

Owing to its high magnetic field, high power, and compact size, the SPARC experiment will operate with divertor conditions at or above those expected in reactor-class tokamaks. Power exhaust at this scale remains one of the key challenges for practical fusion energy. Based on empirical scalings, the peak unmitigated divertor parallel heat flux is projected to be greater than 10 GW m -2 . This is nearly an order of magnitude higher than has been demonstrated to date. Furthermore, the divertor parallel Edge-Localized Mode (ELM) energy fluence projections (~11–34 MJ m -2 ) are comparable with those for ITER. However, the relatively short pulse length (~25 s pulse, with a ~10 s flat top) provides the opportunity to consider mitigation schemes unsuited to long-pulse devices including ITER and reactors. The baseline scenario for SPARC employs a ~1 Hz strike point sweep to spread the heat flux over a large divertor target surface area to keep tile surface temperatures within tolerable levels without the use of active divertor cooling systems. In addition, SPARC operation presents a unique opportunity to study divertor heat exhaust mitigation at reactor-level plasma densities and power fluxes. Not only will SPARC test the limits of current experimental scalings and serve for benchmarking theoretical models in reactor regimes, it is also being designed to enable the assessment of long-legged and X-point target advanced divertor magnetic configurations. Experimental results from SPARC will be crucial to reducing risk for a fusion pilot plant divertor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Real-time estimation and control of divertor surface heat flux on the DⅢ-D tokamak

We report Future tokamaks will require robust technologies for the mitigation of heat exhaust onto the plasma-facing components. As a first step towards this development, a system has been developed at DIII-D that estimates and controls in real-time the heat flux to the PFCs. Real-time estimation of the peak power flux from this model-based approach is validated with off-line infra-red measurements for various DIII-D plasma discharges. A nonlinear free-boundary simulation code (GSevolve) is used for simulating the closed loop response and for the off-line determination of the control parameters. The implementation and first experimental results of the application during the DIII-D plasma campaign are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hermeticity of SiC/SiC composite and monolithic SiC tubes irradiated under radial high-heat flux

Demonstration of hermetic SiC fiber–reinforced SiC matrix composite cladding under normal operating environments has been identified as one of the most critical feasibility issues for accident-tolerant fuel cladding in light-water reactors. This study provides critical experimental data needed for understanding the effects of irradiation on hermeticity. SiC composite and monolithic tubes were neutron-irradiated to 2 displacements per atom with and without a nominal radial heat flux of 0.6 MW/m2 to produce a simulated in-pile stress state for the normal operation of a light-water reactor. The through-thickness temperature gradient under irradiation results in a gradient in swelling, which causes a significant stress buildup. Such irradiation-induced stress was modeled using a commercial finite element analysis code. The radial heat flux–irradiation synergism was experimentally investigated by constructing a special irradiation capsule and evaluating the helium hermeticity of the specimens. The simulated stress state exhibited a near equi-biaxial tensile axial and hoop stress of ~150 MPa at the inner surface of the SiC composite tube. This stress level is potentially beyond the matrix cracking stress. Degradation of hermeticity of the SiC composite tubes was observed after irradiation, indicating irradiation-induced cracking, whereas the irradiated monolithic SiC tubes remained hermetic. In conclusion, the results indicate that loss of hermeticity caused by radiation-induced microcracking is a potential issue for SiC composite cladding, depending on the magnitude of the temperature gradients. Coating the outer surface of the cladding was identified as a mitigation strategy that might overcome the cracking issue.

36 MATERIALS SCIENCE↗

Deciphering the sensitivity of urban canopy air temperature to anthropogenic heat flux with a forcing-feedback framework

Abstract The sensitivity of urban canopy air temperature ( T a ) to anthropogenic heat flux ( Q A H ) is known to vary with space and time, but the key factors controlling such spatiotemporal variabilities remain elusive. To quantify the contributions of different physical processes to the magnitude and variability of Δ T a / Δ Q A H (where Δ represents a change), we develop a forcing-feedback framework based on the energy budget of air within the urban canopy layer and apply it to diagnosing Δ T a / Δ Q A H simulated by the Community Land Model Urban over the contiguous United States (CONUS). In summer, the median Δ T a / Δ Q A H is around 0.01 K W m − 2 − 1 over the CONUS. Besides the direct effect of Q A H on T a , there are important feedbacks through changes in the surface temperature, the atmosphere–canopy air heat conductance ( c a ), and the surface–canopy air heat conductance. The positive and negative feedbacks nearly cancel each other out and Δ T a / Δ Q A H is mostly controlled by the direct effect in summer. In winter, Δ T a / Δ Q A H becomes stronger, with the median value increased by about 20% due to weakened negative feedback associated with c a . The spatial and temporal (both seasonal and diurnal) variability of Δ T a / Δ Q A H as well as the nonlinear response of Δ T a to Δ Q A H are strongly related to the variability of c a , highlighting the importance of correctly parameterizing convective heat transfer in urban canopy models.

54 ENVIRONMENTAL SCIENCES↗

Anisotropic Heating and Parallel Heat Flux in Electron-only Magnetic Reconnection with Intense Guide Fields

Electron-only reconnection (E-REC) is a process recently observed in the Earth’s magnetosheath, where magnetic reconnection occurs at electron kinetic scales, and ions do not couple to the reconnection process. Electron-only reconnection is likely to have a significant impact on the energy conversion and dissipation of turbulence cascades at kinetic scales in some settings. This paper investigates E-REC under different intensities of strong guide fields (the ratio between the guide field and the in-plane asymptotic field strength is 5, 10 and 20, respectively) via two-dimensional fully kinetic particle-in-cell simulations, focusing on electron heating. The simulations are initialized with a force-free current sheet equilibrium under various intensities of strong guide fields. Similarly to previous experimental studies, electron temperature anisotropy along separatrices is observed, which is found to be mainly caused by the variations of parallel temperature. Both regions of anisotropy and parallel temperature increase/decrease along separatrices become thinner with increasing guide fields. Besides, we find a transition from a quadrupolar to a hexapolar (six-polar) to an octopolar (eight-polar) structure in temperature anisotropy and parallel temperature as the guide field intensifies. Non-Maxwellian electron velocity distribution functions (EVDFs) at different locations in the three simulations are observed. Our results show that parallel electron velocity varies notably with different guide field intensities and finite parallel electron heat flux density is observed. The three simulations exhibit features of the Chew–Goldberger–Low theory, with the level of consistency increasing as the guide field strength increases. This explains the electron parallel temperature variations and the shape of the EVDFs observed along the separatrices. This work may provide insights into the understanding of electron heating and parallel heat flux density in E-REC observed in the turbulent magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

On the Importance of Precipitation‐Induced Surface Sensible Heat Flux for Diurnal Cycle of Precipitation in the Maritime Continent

Abstract The Maritime Continent (MC) exhibits a pronounced diurnal cycle in precipitation, with many high‐resolution models overestimating the diurnal peak and predicting earlier precipitation over the islands than observed. We hypothesize that part of this model bias comes from ignoring precipitation‐induced surface sensible heat flux ( Q P ). To test this conjecture, we performed simulations with and without Q P for April 2009 and June 2006. The inclusion of Q P reduced the bias in diurnal peak precipitation amplitude by 83% in April 2009 and 23% in June 2006. Similarly, the bias in precipitation peak timing decreased by 26% and 15%, respectively. This bias reduction was even more prominent during periods of heavier rainfall. This improvement in both the amplitude and phase of diurnal precipitation also led to a reduction in bias for total precipitation by ∼10%. These findings suggest that Q P cannot be neglected over the MC, particularly during heavy precipitation.

54 ENVIRONMENTAL SCIENCES↗

The Role of Non-Local Effects on Surface Sensible Heat Flux Under Different Types of Thermal Structures Over the Arctic Sea-Ice Surface

The effects of atmospheric thermal structure on the surface energy flux are poorly understood over the Arctic sea-ice surface. Here, we explore the mechanism of sensible heat exchange under different types of thermal structures over the Arctic sea-ice surface by using data collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate expedition. The quadrant analysis indicates that strong surface temperature inversions below 100 m enhance non-local effects on the positive (upward) sensible heat flux ($\overline{w'θ'}$) through entrainment of large eddies from the convective boundary layer aloft. However, strong surface inversions restrict the contributions of large eddies to the negative (downward) $\overline{w'θ'}$ due to intensified surface stability. By inspecting the existing parameterization schemes, we found that the European Center for Medium-Range Weather Forecasts Integrated Forecasting System scheme fails to predict the impacts of non-local processes on the positive $\overline{w'θ'}$, and an adjustment term to correct the bias of parameterized $\overline{w'θ'}$ is proposed.

54 ENVIRONMENTAL SCIENCES↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental investigations of Critical Heat Flux re-occurrence on post-CHF surfaces

Under the extreme environments of light water reactors, the cladding materials demonstrate evolutionary transformations in terms of material compositions, surface morphologies, and thermal-physical properties. This study investigates how the temperature overshooting of Critical Heat Flux (CHF) affects the re-occurrence of CHF on the post-CHF surfaces. Experimental results reveal that the CHF difference between as-received and post-CHF surfaces can be significant, which depends on materials. CHF is enhanced on post-CHF Stainless Steel (SS 316) specimens while it deteriorates on post-CHF Inconel-600 specimens. In comparison with the as-received surfaces, the post-CHF surface of SS 316 is more hydrophobic, while Inconel 600 is more hydrophilic. The scanning electron microscope micrographs of post-CHF surfaces show that surface morphologies that are structured by oxide crystals are formed on SS 316 samples but not on Inconel 600 samples. The physical rationale behind the CHF difference could be boiling heat transfer conjugated with thermal-physical proprieties of investigated surface materials and surface morphologies features. In conclusion, the results imply that it is indispensable to bookkeep the evolutionary changes of cladding surface materials, especially for cladding candidates of Accident Tolerant Fuel since operation histories can leave footprints on cladding surfaces, thus resulting in CHF re-occurrence differences.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predicting critical heat flux with uncertainty quantification and domain generalization using conditional variational autoencoders and deep neural networks

Deep generative models (DGMs) can generate synthetic data samples that closely resemble the original dataset, addressing data scarcity. In this work, we developed a conditional variational autoencoder (CVAE) to augment critical heat flux (CHF) data used for the 2006 Groeneveld lookup table. To compare with traditional methods, a fine-tuned deep neural network (DNN) regression model was evaluated on the same dataset. Both models achieved small mean absolute relative errors, with the CVAE showing more favorable results. Uncertainty quantification (UQ) was performed using repeated CVAE sampling and DNN ensembling. The DNN ensemble improved performance over the baseline, while the CVAE maintained consistent results with less variability and higher confidence. Both models achieved small errors inside and outside the training domain, with slightly larger errors outside. Altogether, the CVAE performed better than the DNN in predicting CHF and exhibited better uncertainty behavior.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

Characteristics of grassy ELMs and their impact on the divertor heat flux width

We report BOUT++ turbulence simulations are conducted for a 60 s steady-state long pulse high β p EAST grassy ELM discharge. BOUT++ linear simulations show that the unstable mode spectrum covers a range of toroidal mode numbers from low-n (n = 10–15) peeling–ballooning modes (P–B) to high-n (n = 40–80) drift-Alfvén instabilities. Nonlinear simulations show that the ELM crash is triggered by low-n peeling modes and fluctuation is generated at the peak pressure gradient position and radially spread outward into the scrape-off-layer, even though the drift-Alfvén instabilities dominate the linear growth phase. However, drift-Alfvén turbulence delays the onset of the grassy ELM and enhances the energy loss with the fluctuation extending to pedestal top region. Simulations further show that if the peeling drive is removed, the fluctuation amplitude drops by an order of magnitude and the ELM crashes disappear. The divertor heat flux width is ~2 times larger than the estimates based on the HD model and the Eich's ITPA multi-tokamak scaling (or empirical Eich scaling) due to the strong radial turbulence transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗