Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Afterbody Heat Flux Measurements in the NASA Ames HFFAF Ballistic Range

In order to measure afterbody heat fluxes over a model in the ballistic range, the required modifications to a proven technique for measuring forebody heat fluxes are described. This involves the use of an extended helium gas plume to remove the glowing wake and the use of special high conductivity, high temperature capable graphite-filled plastic for the afterbody. The models and test conditions are described. Data in the form of plots of the surface temperature of the models are presented. Finally, experimental and computational fluid dynamic (CFD) heat flux data for forebody and afterbody heat fluxes are presented and compared. Data are presented for a 45 degree sphere-cone (with a projecting rear stud) at 2.70 km/s and for a sphere at 4.76 km/s. Both models were launched into 76 Torr of CO2 gas. The experimental forebody heat fluxes were within 1.5% of the CFD values. The experimental afterbody heat fluxes were within 1% of the CFD values for the sphere, but only 51% of the CFD values for the sphere-cone.

Bogdanoff, David W.↗

Impact of error fields and error field correction on heat fluxes in SPARC

Using a single toroidal array of coils to reduce the m,n = 2,1 resonant error field (EF) produced by the misalignment of the axisymmetric coils in SPARC can result in the enhancement of the local divertor heat fluxes. Managing high divertor heat fluxes (q ∥ $\simeq$ 10 GW m -2 ) poses a challenge for compact tokamak devices such as SPARC. The presence of non-axisymmetric magnetic field perturbations adds complexity to the problem by generating intricate 3D edge magnetic topologies that alter the heat flux distributions on the target plates. The aim of this work is to investigate the impact of the EF correction (EFC) on the heat fluxes at the divertor plates in SPARC. The MHD code M3DC1 has been used to simulate the 3D magnetic perturbations generated by the shift and tilt of several axisymmetric coils within specified tolerances, as well as from the array of EFC coils located at the midplane. Using a heuristic model that extends the concept of an axisymmetric heat flux layer to 3D plasmas, the resultant heat flux distributions is derived from magnetic footprints calculated with the MAFOT code. The results show that the EFC could either decrease or further enhance the local heat flux when used to correct the m,n = 2,1 resonant EF to enhance the core plasma performance.

3D fields↗

Progress in the measurement of SSME turbine heat flux with plug-type sensors

Data reduction was completed for tests of plug-type heat flux sensors (gauges) in a turbine blade thermal cycling tester (TBT) that is located at NASA/Marshall Space Flight Center, and a typical gauge is illustrated. This is the first time that heat flux has been measured in a Space Shuttle Main Engine (SSME) Turbopump Turbine environment. The development of the concept for the gauge was performed in a heat flux measurement facility at Lewis. In this facility, transient and steady state absorbed surface heat flux information was obtained from transient temperature measurements taken at points within the gauge. A schematic of the TBT is presented, and plots of the absorbed surface heat flux measured on the three blades tested in the TBT are presented. High quality heat flux values were measured on all three blades. The experiments demonstrated that reliable and durable gauges can be repeatedly fabricated into the airfoils. The experiment heat flux data are being used for verification of SSME analytical stress, boundary layer, and heat transfer design models. Other experimental results and future plans are also presented.

Liebert, Curt H.↗

Experimental and Numerical Characterization of Transient Insertion of Heat Flux Gages in a Cylindrical Black Body Cavity at 1100 C

Initial transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels of interest to reciprocating and gas turbine engine industries as well as the aerospace industry. These transient models are based on existing, experimentally validated, steady state models of the cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system and time varying electrical current passing through the resistance heated blackbody. Heat fluxes computed using the initial transient models were compared to experimental measurements. The calculated and measured transient heat fluxes were within 5% indicating that the major physical phenomena in the transient calibration had been captured by the models. The predicted and measured transient heat fluxes were also compared at two different gage insertion depths. These results indicated that there is an optimum insertion position which maximizes heat flux and minimizes cavity disturbance.

Abdelmessih, A. N.↗

Estimation of Corn Latent Heat Flux from High Resolution Thermal Imagery

Crop evapotranspiration (ET), which is directly related to latent heat flux, is also a key indicator in determining the water status of crops. In order to estimate the latent heat flux, two-source energy balance (TSEB) models have been developed for thermal imagery from satellite platforms. However, because of the coarse resolution of thermal sensors on the satellite, distinguishing soil and vegetation is difficult which complicates the calculation process and introduces errors in latent heat estimates. In this research, high-resolution thermal datasets (0.05 m) and corresponding RGB datasets (0.03 m) were used for calculating crop latent heat flux using an adapted TSEB model. The RGB datasets were used for supervised classification of soil and vegetation, and the classification results were then used to filter the thermal mosaics to separate vegetation and soil temperatures. The vegetation temperature is used for calculating latent heat flux and the results are validated against the ground reference measurements of latent heat using a handheld porometer. The objective of this research is to introduce a workflow including an adapted TSEB model which is customized for high resolution thermal images from unmanned aircraft systems (UAS) to estimate the latent heat flux of row crops in agricultural fields. Nine dates of data collection in 2018 and 2020 have been evaluated and the root mean square error (RMSE) varies between 16 to 106 W/m2 depending on the days after planting (DAP) and the time of measurement for each day. The results indicate that the workflow introduced here is able to provide estimates of instantaneous latent heat flux (evapotranspiration) measurements for row crops in agricultural fields which will enable people to make reliable decisions related to irrigation scheduling.

54 ENVIRONMENTAL SCIENCES↗

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS↗

Vertical eddy heat fluxes from model simulations

Vertical eddy fluxes of heat are calculated from simulations with a variety of climate models, ranging from three-dimensional GCMs to a one-dimensional radiative-convective model. The models' total eddy flux in the lower troposphere is found to agree well with Hantel's analysis from observations, but in the mid and upper troposphere the models' values are systematically 30 percent to 50 percent smaller than Hantel's. The models nevertheless give very good results for the global temperature profile, and the reason for the discrepancy is unclear. The model results show that the manner in which the vertical eddy flux is carried is very sensitive to the parameterization of moist convection. When a moist adiabatic adjustment scheme with a critical value for the relative humidity of 100 percent is used, the vertical transports by large-scale eddies and small-scale convection on a global basis are equal: but when a penetrative convection scheme is used, the large-scale flux on a global basis is only about one-fifth to one-fourth the small-scale flux. Comparison of the model results with observations indicates that the results with the latter scheme are more realistic. However, even in this case, in mid and high latitudes the large and small-scale vertical eddy fluxes of heat are comparable in magnitude above the planetary boundary layer.

Stone, Peter H.↗

Monitoring Delamination of Thermal Barrier Coatings During Interrupted High-Heat-Flux Laser Testing using Luminescence Imaging

This presentation showed progress made in extending luminescence-base delamination monitoring to TBCs exposed to high heat fluxes, which is an environment that much better simulates actual turbine engine conditions. This was done by performing upconversion luminescence imaging during interruptions in laser testing, where a high-power CO2 laser was employed to create the desired heat flux. Upconverison luminescence refers to luminescence where the emission is at a higher energy (shorter wavelength) than the excitation. Since there will be negligible background emission at higher energies than the excitation, this methods produces superb contrast. Delamination contrast is produced because both the excitation and emission wavelengths are reflected at delamination cracks so that substantially higher luminescence intensity is observed in regions containing delamination cracks. Erbium was selected as the dopant for luminescence specifically because it exhibits upconversion luminescence. The high power CO2 10.6 micron wavelength laser facility at NASA GRC was used to produce the heat flux in combination with forced air backside cooling. Testing was performed at a lower (95 W/sq cm) and higher (125 W/sq cm) heat flux as well as furnace cycling at 1163C for comparison. The lower heat flux showed the same general behavior as furnace cycling, a gradual, "spotty" increase in luminescence associated with debond progression; however, a significant difference was a pronounced incubation period followed by acceleration delamination progression. These results indicate that extrapolating behavior from furnace cycling measurements will grossly overestimate remaining life under high heat flux conditions. The higher heat flux results were not only accelerated, but much different in character. Extreme bond coat rumpling occurred, and delamination propagation extended over much larger areas before precipitating macroscopic TBC failure. This indicates that under the higher heat flux (and surface & interface temperatures), the TBC was more tolerant of damage. The main conclusions were that high heat flux conditions can not only accelerate TBC debond progression but can also grossly alter the pathway of delamination.

Eldridge, Jeffrey I.↗

On the Relationship Between CYGNSS Surface Heat Fluxes and the Life Cycle of Low-Latitude Ocean Extratropical Cyclones

Surface latent and sensible heat fluxes are important for extratropical cyclone evolution and intensification. Because extratropical cyclone genesis often occurs at low-latitude, CYGNSS surface latent and sensible heat flux retrievals are composited to provide a mean picture of their spatial distribution in low-latitude oceanic extratropical cyclones. CYGNSSn heat fluxes are not affected by heavy precipitation and offer observations of storms with frequent revisit times. Consistent with prior results obtained for cyclones in the Gulf Stream region, the fluxes are strongest in the wake of the cold fronts, and weakest to negative in the warm sector in advance of the cold fronts. As cyclone strength increases, or mean precipitable water decreases, the maximum in surface heat fluxes increases while the minimum decreases. This impacts the changes in fluxes during cyclone intensification: the post-cold frontal surface heat flux maximum increases due to the increase in near surface winds. During cyclone dissipation, the fluxes in this sector decrease, due to the decrease in winds and in temperature and humidity contrast. The warm sector minimum decreases throughout the entire cyclone lifetime and is mostly driven by sea-air temperature and humidity contrast changes. However, during cyclone dissipation, the surface heat fluxes increase along the cold front in a narrow band to the east, independently from changes in the cyclone characteristics. This suggests that, during cyclone dissipation, energy transfers from the ocean to the atmosphere are linked to frontal in addition to synoptic-scale processes.

CYGNSS↗

Heat flux measurements

This paper discusses a new automated, computer-controlled heat flux measurement facility. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gages for continuous fast transient surface heat flux measurement on turbine blades operating in Space Shuttle main engine turbopumps. The facility is also useful for durability testing at fast temperature transients.

Liebert, Curt H.↗

Turbine blade and vane heat flux sensor development, phase 2

The development of heat flux sensors for gas turbine blades and vanes and the demonstration of heat transfer measurement methods are reported. The performance of the heat flux sensors was evaluated in a cylinder in cross flow experiment and compared with two other heat flux measurement methods, the slug calorimeter and a dynamic method based on fluctuating gas and surface temperature. Two cylinders, each instrumented with an embedded thermocouple sensor, a Gardon gauge, and a slug calorimeter, were fabricated. Each sensor type was calibrated using a quartz lamp bank facility. The instrumented cylinders were then tested in an atmospheric pressure combustor rig at conditions up to gas stream temperatures of 1700K and velocities to Mach 0.74. The test data are compared to other measurements and analytical prediction.

Atkinson, W. H.↗

Simulation of divertor heat flux width on EAST by BOUT++ transport code

The BOUT++ edge plasma transport code is applied to study the effects of neutral recycling, drifts and heating scheme on edge plasma profiles and the divertor heat flux width of two discharges of the experimental advanced superconducting tokamak (EAST) steady-state H-mode plasmas heated by low hybrid wave (LHW) and neutral beam (NB), respectively. Neutral recycling seems to have played an important role in the plasma density profile. The edge plasma density drops dramatically for the case w/o neutral recycling, while it can be sustained for the case w/ neutral recycling. Drifts are found to have significant influences on edge plasma profiles. Both the amplitude and width of the divertor heat flux are found to have increased a lot due to drifts. The simulated heat flux width w/ drifts for the two discharges shows reasonable agreement with the experiments. However, the width from the simulation and experiment for the LHW heated discharge is much larger than that of the NB heated discharge. Comparison with Goldston's drift-based model and more detailed analysis on the heat flux contributions from drifts versus turbulence show that drifts are the dominant factor in edge plasma transport for both LHW and NB heated discharges, while turbulence may have played a more important role in determining the heat flux width in LHW heated discharges than that in NB heated discharges. This may account for the larger heat flux width in the LHW heated discharge. The magnetic topology and the equilibrium change by the LHW power may also be a potential reason for the larger heat flux width in the LHW heated discharges, which still needs more evidence and studies to support it. Finally, additional SOLPS simulation w/o drifts for the two discharges show reasonable agreement with the counterpart from the BOUT++ simulation, suggesting the two are both suitable codes for EAST edge plasma simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-contact heat flux measurement using a transparent sensor

A working non-contact heat flux sensor was demonstrated using a transparent material (sapphire) and a multiwavelength pyrometer. The pyrometer is used to measure the temperatures of the two surfaces of the sensor from the spectrum of radiation originating from them. The heat conducted through the material is determined from the temperature difference of the two surfaces and the thermal conductivity of the material. The measured heat flux is equal to the incident heat flux within experimental error indicating that no calibration would be necessary. A steady state heat flux of 100 kW/sq m was easily achieved.

Ng, Daniel↗

Advanced high temperature heat flux sensors

To fully characterize advanced high temperature heat flux sensors, calibration and testing is required at full engine temperature. This required the development of unique high temperature heat flux test facilities. These facilities were developed, are in place, and are being used for advanced heat flux sensor development.

Atkinson, W.↗

Heat flux microsensor measurements and calibrations

A new thin-film heat flux gage has been fabricated specifically for severe high temperature operation using platinum and platinum-10 percent rhodium for the thermocouple elements. Radiation calibrations of this gage were performed at the AEDC facility over the available heat flux range (approx. 1.0 - 1,000 W/cu cm). The gage output was linear with heat flux with a slight increase in sensitivity with increasing surface temperature. Survivability of gages was demonstrated in quench tests from 500 C into liquid nitrogen. Successful operation of gages to surface temperatures of 750 C has been achieved. No additional cooling of the gages is required because the gages are always at the same temperature as the substrate material. A video of oxyacetylene flame tests with real-time heat flux and temperature output is available.

Terrell, James P.↗

Geometrical correction factors for heat flux meters

General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. The local averaging error e(x) is defined as the difference between the measured value of the heat flux and the local value which occurs at the center of the gage. In terms of e(x), a correction procedure is presented which allows a better estimate for the true value of the local heat flux. For many practical problems, it is possible to use relatively large gages to obtain acceptable heat flux measurements.

Baumeister, K. J.↗