Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Scaling and universality in heart rate variability distributions

We find that a universal homogeneous scaling form describes the distribution of cardiac variations for a group of healthy subjects, which is stable over a wide range of time scales. However, a similar scaling function does not exist for a group with a common cardiopulmonary instability associated with sleep apnea. Subtle differences in the distributions for the day- and night-phase dynamics for healthy subjects are detected.

NASA Discipline Cardiopulmonary↗

The effect of restraining on the heart rate in guinea pigs

The emotional effect of different applications of electrodes and the fixation for cariographic examination was investigated using guinea pigs. The effect of the stress is discussed in terms of heart rhythm and behavior.

Mikiskova, H.↗

Short-term effects of particulate matter in metro cabin on heart rate variability in young healthy adults: Impacts of particle size and source

Highlights: • Exposure to metro PM was associated with decreased HRV in young healthy adults. • The strength and lag time for effects of PM on HRV varied by particle size. • Greater decreases in HRV suggested that females were more susceptible to the effects of PM exposure. • Ambient PM from combustion source (indicated by black carbon) has adverse health effects on passengers in cabin. Metro system has become popular in urban areas. However, short-term effects of size-fractionated particulate matter (PM) on cardiac autonomic function in metro system remain unexplored.

54 ENVIRONMENTAL SCIENCES↗

Interaction of semicircular canal stimulation with carotid baroreceptor reflex control of heart rate

The carotid-cardiac baroreflex contributes to the prediction of orthostatic tolerance; experimental attenuation of the reflex response leads to orthostatic hypotension in humans and animals. Anecdotal observations indicate that rotational head movements about the vertical axis of the body can also induce orthostatic bradycardia and hypotension through increased parasympathetic activity. We therefore measured the chronotropic response to carotid baroreceptor stimulation in 12 men during varying conditions of vestibulo-oculomotor stimulation to test the hypothesis that stimulation of the semicircular canals associated with head movements in the yaw plane inhibits cardioacceleration through a vagally mediated baroreflex. Carotid-cardiac baroreflex response was assessed by plotting R-R intervals (ms) at each of 8 neck pressure steps with their respective carotid distending pressures (mmHg). Calculated baroreflex gain (maximal slope of the stimulus-response relationship) was measured under 4 experimental conditions: 1) sinusoidal whole-body yaw rotation of the subject in the dark without visual fixation (combined vestibular-oculomotor stimulation); 2) yaw oscillation of the subject while tracking a small head-fixed light moving with the subject (vestibular stimulation without eye movements); 3) subject stationary while fixating on a small light oscillating in yaw at the same frequency, peak acceleration, and velocity as the chair (eye movements without vestibular stimulation); and 4) subject stationary in the dark (no eye or head motion). Head motion alone and with eye movement reduced baseline baroreflex responsiveness to the same stimulus by 30%. Inhibition of cardioacceleration during rotational head movements may have significant impact on functional performance in aerospace environments, particularly in high-performance aircraft pilots during high angular acceleration in aerial combat maneuvers or in astronauts upon return from spaceflight who already have attenuated baroreflex functions.

Review, Tutorial↗

Cardiotachometer displays heart rate on a beat-to-beat basis

Electronics for this system may be chosen so that complete calculation and display may be accomplished in a few milliseconds, far less than even the fastest heartbeat interval. Accuracy may be increased, if desired, by using higher-frequency timing oscillator, although this will require large capacity registers at increased cost.

Rasquin, J. R.↗

Stress, temperature, heart rate, and hibernating factors in hamsters

Pathophysiological conditions resulting from prolonged exposure to zero gravity, cabin constraint, altered ambient environment, whether it be noise, vibrations, high temperatures, or combinations of such factors, are studied in laboratory animals and applied to manned space flight. Results and plans for further study are presented. Specific topics covered include: thermoregulation and its role in reflecting stress and adaptation to the gravity free environment and cabin confinement with its altered circadian forcings; renal function and its measurement in electrolyte distribution and blood flow dynamics; gastronintestinal function and an assessment of altered absorptive capacity in the intestinal mucosa; and catecholamine metabolism in terms of distribution and turnover rates in specific tissues.

Musacchia, X. J.↗

Recovery from exercise at varying work loads - Time course of responses of heart rate and systolic intervals

The time course of the recovery period was characterized by noninvasive measurements after 4 minute bicycle exercise at 3 separate work loads in volunteers with normal peak responses. Most responses started immediately to return toward resting control values. Left ventricular ejection time and stroke volume change are discussed. Changes in pre-ejection period were determined by changes in isovolume contraction time, and factors affecting the degree and rate of return are considered. The rates of change in the ejection time index and in the ratio pre-ejection period/left ventricular ejection time were virtually independent of load throughout most of recovery.

Nandi, P. S.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗

Evaluating the Ability of Heart Rate and EEG to Control Alertness during Performance

The major focus of the present proposal was to examine psychophysiological indices that show promise for invoking different modes of automation in an adaptive automation system. With the increased use of automation in today's work environment, people's roles in the work place are being redefined from that of active participant to one of passive monitor. Although the introduction of automated systems has a number of benefits, there are also a number of disadvantages regarding worker performance. Byrne and Parasuraman have argued for the use of psychophysiological measures in the development and the implementation of adaptive automation. While performance based, model based, and psychophysiologically based adaptive automation systems have been studied, the combined use of several psychophysiological measures has never been investigated. Such a combination provides the advantage of real time evaluation of the state of the subject in two relevant dimensions and offers a more realistic approach to the implementation of adaptive automation compared to the use of either dimension by itself.

Freeman, Fred↗

WISE-2005 Protective Effect of Exercise within LBNP Countermeasure Detected by Heart Rate Response to Low Levels of LBNP

Sixteen women were studied before, during and after a 60 day, continu ous 6" head-down bed-rest (HDBR). Subjects were randomly assigned to two groups: Control (no countermeasures) and Exercise+LBNP (supine ru nning within an LBNP chamber for 40-min followed by 10-min passive L BNP for 3-4 days/week, plus flywheel resistive training of the legs e very third day). Cardiovascular responses were observed before bed re st, on day 50 of HDBR and R+8 after bed rest. Subjects were supine in the LBNP device with suction applied at 0, -10, -20 and -30 mmHg LBN P for 2-min per stage. In the pre-bed rest testing, there was no diff erence in HR between the groups at rest or at -30 mmHg. On HDBR day 50, HR was elevated at supine rest for the Con not the Ex group, whil e at -30 mmHg HR was elevated above pre-HDBR for both groups, but the magnitude of increase from Pre- to HDBR day 50 was less for the Ex g roup than for the Con group. The change in HR on HDBR day 50 is an im portant indicator as it was less than 24-hours after the Exercise+LBN P countermeasure on day 49. After bed rest, no specific countermeasu res were provided in the first week, so HR responses on day R+8 refle cted the effects of bed rest with or without countermeasure plus any recovery from simply returning to the upright posture. Relative to th e Pre-bed rest responses, HR on day R+8 had recovered in the Ex group but was still elevated in the Con group. These results indicate that the cardiovascular response to LBNP is preserved to a greater degre e during bed rest by the countermeasures, and further that the cardio vascular response returned to pre-bed rest much more rapidly in the E xercise+LBNP group than hi the group that received no cardiovascular countermeasures.

Hughson, R. L.↗