Experiments on ion-cyclotron-wave generation using an electrostatically-shielded rf coil
Power absorption measurement by rf coil and resulting sinusoidal field distortion in hydrogen plasma
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Power absorption measurement by rf coil and resulting sinusoidal field distortion in hydrogen plasma
Measurement of change in plasma potential and magnetic field of hydrogen plasma impinging on magnetic dipole - simulation of solar wind-earth interaction
The magnetization of a high-beta (plasma energy density/magnetic-field energy density) hydrogen-plasma beam injected into a vacuum transverse magnetic field is studied experimentally. Nominal parameters were Ti = 1 eV, Te = 5 eV, n = 3 x 10 to the 13th/cu cm or less, v(i) = 7 x 10 to the 6th cm/sec or less, t(pulse) less than 70 microsec, and Bz = 300 G or less. Plasma characteristics were measured for a wide beam and a downstream distance, x = 300 rho(i) or less, where x is the downstream distance and rho(i) is the ion gyroradius. A brief initial state of diamagnetic propagation is observed, followed by magnetized propagation accompanied by beam compression transverse to B with as much as a factor of 4 increase in density and a slight drift of the beam in the ion Lorentz force direction.
This document describes a simple nonequilibrium energy exchange and chemical reaction model to be used in a computational fluid dynamics calculation for a hydrogen plasma excited by microwaves. The model takes into account the exchange between the electrons and excited states of molecular and atomic hydrogen. Specifically, electron-translation, electron-vibration, translation-vibration, ionization, and dissociation are included. The model assumes three temperatures, translational/rotational, vibrational, and electron, each describing a Boltzmann distribution for its respective energy mode. The energy from the microwave source is coupled to the energy equation via a source term that depends on an effective electric field which must be calculated outside the present model. This electric field must be found by coupling the results of the fluid dynamics and kinetics solution with a solution to Maxwell's equations that includes the effects of the plasma permittivity. The solution to Maxwell's equations is not within the scope of this present paper.
The mass of the hydrogen isotope in micrometer-sized aqueous droplets introduced into an ICP has been found to affect the degree of resulting plasma perturbation. Studied plasma perturbations include local plasma cooling, plasma shrinkage due to thermal pinching, and changes in plasma impedance. The local cooling effect caused by a vaporizing aerosol droplet was found to be similar between H 2 O and D 2 O. This finding is likely a result of the similar heat capacities and vaporization rates of H 2 O and D 2 O droplets and of the comparable thermal conductivities and dissociation kinetics of H 2 O and D 2 O vapor. In contrast, a clear isotope effect was observed for plasma shrinkage and impedance change, with H 2 O causing a considerably stronger effect. Plasma shrinkage, gauged by the reduction in Ar emission at the edge of the plasma, was detected at all observation heights within the load-coil region, with D 2 O droplets causing as much as 30% less of an effect than H 2 O. Likewise, D 2 O droplets induce significantly less change in plasma impedance than H 2 O droplets. Depending on experimental conditions and the probing method, changes in plasma impedance caused by monodisperse D 2 O droplets were only 52%–80% that of H 2 O. The lower influence on plasma shrinkage and impedance change for D 2 O droplets is believed to be related to the much lower thermal conductivity of atomic deuterium, around 70% that of atomic hydrogen (protium). The time required for the plasma impedance to return to its original steady-state value was comparatively long (~10 ms) and similar for H 2 O and D 2 O droplets.
Tin deposition mitigation employs hydrogen radicals and ions, formed in a hydrogen plasma, to interact with tin to form tin hydride (SnH 4 ) in the gaseous state, which is then pumped away. Surface wave plasma (SWP) technology developed at Illinois generates hydrogen radicals and ions, resulting in tin etch rates that are high enough to keep extreme ultraviolet (EUV) lithographic tools clean. An advantage of an SWP antenna is the ability to generate a high density of hydrogen radicals and hydrogen ions directly at the desired etching location. In situ etching of tin enables high availability EUV tools by maintaining high reflectivity of the multilayer mirror of the collector. Additionally, the SWP is characterized with low ion energies and low electron temperature, such that the multilayer mirror does not suffer any damage from sputtering or implantation of hydrogen ions during operation. Here, experiments elucidating the fundamental processes of tin removal are conducted by varying pressure, power, surface temperature, and gas flow rate in order to observe the etch rate behavior. Our results have shown that the presence of hydrogen ions increases etch rates because ion bombardment weakens Sn–Sn bonds, which, in turn, allows for a higher rate of chemical etching by the radicals. The ion bombardment reduces the number of radicals needed to etch a single tin atom to the range of 10 2 –10 3 . The linear SWP antenna yields plasma densities on the order of 10 17 to 10 18 m -3 and radical densities on the order of 10 18 to 10 19 m -3 , allowing for greater utilization of ion etch enhancement. Etch rates of up to 200 nm/min have been achieved. The surface temperature of the samples is an important factor in the etching process such that the decrease in the surface temperature increases the etch rates and decreases the hydrogen desorption rates. In addition, a kinetic etch model is developed to explain the behavior of etch rates as a function of surface temperature. Furthermore, results from experiments performed in an Illinois NXE:3100 chamber will be discussed.
Transverse and longitudinal plasma wave instabilities for two counterstreaming neutral hydrogen plasmas without external fields
The feasibility of using a non-equilibrium hydrogen plasma jet as a chemical synthesis tool was investigated. Four possible processes were identified for further study: (1) production of polycrystalline silicon photovoltaic surfaces, (2) production of SiHCl3 from SiCl4, (3) production of SiH4 from SiHCl3, and (4) purification of SiCl4 by metal impurity nucleation. The most striking result was the recognition that the strongly adhering silicon films, amorphous or polycrystalline, produced in our studies could be the basis for preparing a photovoltaic surface directly; this process has potential advantages over other vapor deposition processes.
Currently, the iron and steel industry is responsible for 7% of global CO 2 emissions. In this review, we summarize the operational principles of current emissions-intensive steelmaking technologies and review emerging low- and zero-carbon technologies that could substantially reduce emissions. Current technologies that are discussed include blast furnaces, electric arc furnaces, and smelting. Promising low-carbon routes include use of alternative reductants for ore processing (hydrogen direct reduction, hydrogen plasma-smelting, hydrogen smelting, and ammonia-based reduction), electrolytic iron production (with aqueous and molten oxide electrolytes) and biocarbon-based electric arc furnace operation. Advantages of each approach are presented, and remaining research hurdles are identified.
The utilization of a cold plasma in chlorination processing is described. Essential equipment and instruments were received, the experimental apparatus assembled and tested, and preliminary experiments conducted. The results of the latter lend support to the original hypothesis: a cold plasma can both significantly enhance and bias chemical reactions. In two separate experiments, a cold plasma was used to reduce TiCl4 vapor and chlorinate ilmenite. The latter, reacted in an argon-chlorine plasma, yielded oxygen. The former experiment reveals that chlorine can be recovered as HCl vapor from metal chlorides in a hydrogen plasma. Furthermore, the success of the hydrogen experiments has lead to an analysis of the feasibility of direct hydrogen reduction of metal oxides in a cold plasma. That process would produce water vapor and numerous metal by-products.
A flow microwave plasma reaction system is used to study the conversion of hydrogen to hydrogen atoms as a function of pressure, power density, cavity tuning, cavity mode, and time in the plasma zone. Hydrogen atom concentration is measured down-stream from the plasma by NOCl titration. Extensive modeling of the plasma and recombination zones is performed with the plasma zone treated as a backmix reaction system and the recombination zone treated as a plug flow. The thermodynamics and kinetics of the recombination process are examined in detail to provide an understanding of the conversion of recombination energy to gas kinetic energy. It is found that cavity tuning, discharge stability, and optimum power coupling are critically dependent on the system pressure, but nearly independent of the flow rate.
The heating of He(+) ions observed by the GEOS satellite at L of about seven starting from an initial anisotropic proton distribution is studied. A simulation of electromagnetic ion cyclotron waves in a plasma consisting of hot anisotropic protons, a dominant thermal hydrogen plasma, and a minority species of helium ions is utilized. It is shown that the thermal ions are heated to 100 times their initial temperature due to the growth of large-amplitude ion cyclotron waves. He(+) ions are heated mainly in the perpendicular direction, and they are heated more than cold H(+) ions. The He(+) ions are heated in a two-step process. First, they are set into oscillations by the growing wave until some of the ions reach a parallel velocity on the order of the resonant velocity; then, strong heating occurs.
Coaxial gun with covergent barrel for focusing high speed blobs of hydrogen plasma
Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.
Experiments have been made on the production and heating of plasmas by the absorption of laser radiation. These experiments were performed to ascertain the feasibility of using laser-produced or laser-heated plasmas as the input for a magnetohydrodynamic (MHD) generator. Such a system would have a broad application as a laser-to-electricity energy converter for space power transmission. Experiments with a 100-J-pulsed CO2 laser were conducted to investigate the breakdown of argon gas by a high-intensity laser beam, the parameters (electron density and temperature) of the plasma produced, and the formation and propagation of laser-supported detonation (LSD) waves. Experiments were also carried out using a 1-J-pulsed CO2 laser to heat the plasma produced in a shock tube. The shock-tube hydrogen plasma reached electron densities of approximately 10 to the 17th/cu cm and electron temperatures of approximately 1 eV. Absorption of the CO2 laser beam by the plasma was measured, and up to approximately 100 percent absorption was observed. Measurements with a small MHD generator showed that the energy extraction efficiency could be very large with values up to 56 percent being measured.
At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius $ρ$ ~ 0.3–0.4) in the hydrogen plasma generated by electron cyclotron resonance heating; it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient ($D$~ 0.02 m 2 s -1 ) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (|$V$| ~ 0.1 m s -1 ) and inward convection in the outer region (|$V$| ~ 0.3 m s -1 ). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low edge plasma density (<1.0 × 10 19 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfil the condition for the suppression of ITG turbulence.
The aim of the present study is to perform a theoretical analysis of different strategies to stabilize energetic-ion-driven resistive interchange mode (EIC) in Large Helical Device (LHD) plasma. In this work, we use a reduced MHD for the thermal plasma coupled with a gyrofluid model for the energetic particles (EP) species. The hellically trapped EP component is introduced through a modification of the drift frequency to include their precessional drift. The stabilization trends of the 1/1 EIC observed experimentally with respect to the thermal plasma density and temperature are reproduced by the simulations, showing a reasonable agreement with the data. The LHD operation scenarios with stable 1/1 EIC are identified, leading to the stabilization of the 1/1 EIC if the thermal plasma density and temperature are above a given threshold. Additionally, the 1/1 EIC are also stabilized if the rotational transform is modified in a way that the 1/1 rational surface is located further away than 0.9 times the normalized radius, or the magnetic shear in the plasma periphery is enhanced. Also, LHD discharges with large magnetic fields show a higher EIC destabilization threshold with respect to the thermal plasma density. If the perpendicular NBI deposition region is moved further inward than 0.875 times the normalized radius the 1/1 EIC are also stabilized. Furthermore, increasing the perpendicular NBI voltage such that the EP energy is higher than 30 keV stabilizes the 1/1 EIC. Moreover, deuterium plasmas show a higher stability threshold for the 1/1 EIC than hydrogen plasmas. The experimental data shows a larger time interval between EIC events as the power of the tangential NBI is increased providing that the perpendicular NBI power is at least 13 MW. This implies a stabilizing effect of the tangential NBI.
At the National Ignition Facility, inertial confinement fusion experiments aim to burn and ignite a hydrogen plasma to generate a net source of energy through the fusion of deuterium and tritium ions. The energy deposited by α-particles released from the deuterium–tritium fusion reaction plays the central role in heating the fuel to achieve a sustained thermonuclear burn. In the hydrodynamic picture, α-heating increases the temperature of the plasma, leading to increased reactivity because the mean ion kinetic energy increases. Therefore, the ion temperature is related to the mean ion kinetic energy. In this report we use the moments of the neutron spectrum to study the relationship between the ion temperature (measured by the variance in the neutron kinetic energy spectrum) and the ion mean kinetic energy (measured by the shift in the mean neutron energy). We observe a departure from the relationship expected for plasmas where the ion relative kinetic energy distribution is Maxwell–Boltzmann, when the plasma begins to burn. Understanding the cause of this departure from hydrodynamic behaviour could be important for achieving robust and reproducible ignition.