Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Studying Near-Surface Layers of Germanium Implanted with Cobalt Ions

Results of an investigation of the surface of germanium nanostructured by means of ion implantation are presented. Single-crystalline germanium (c-Ge) plates were irradiated by 40-keV cobalt Co{sup +} ions in a dose range of (2–8) × 10{sup 16} ion/cm{sup 2}. Evolution of the germanium surface morphology with increasing ion dose was studied by method of scanning electron microscopy. It is established that an increase in the ion implantation dose is accompanied by gradual formation of a surface layer consisting of spherical particles with diameters of ~150 nm. Analysis of the X-ray diffraction patterns of samples was indicative of the appearance of nanosized cobalt germanide (CoGe) particles in the ion-implanted surface layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural Design Parameters for Germanium

The fracture toughness and slow crack growth parameters of germanium supplied as single crystal beams and coarse grain disks were measured. Although germanium is anisotropic (A* 1.7), it is not as anisotropic as SiC, NiAl, or Cu. Thus the fracture toughness was similar on the 100, 110, and 111 planes, however, measurements associated with randomly oriented grinding cracks were 6 to 30 higher. Crack extension in ring loaded disks occurred on the 111 planes due to both the lower fracture energy and the higher stresses on stiff 111 planes. Germanium exhibits a Weibull scale effect, but does not exhibit significant slow crack growth in distilled water. (n 100), implying that design for quasi static loading can be performed with scaled strength statistics. Practical values for engineering design are a fracture toughness of 0.69 0.02 MPam (megapascals per square root meter) and a Weibull modulus of m 6 2. For well ground and reasonable handled coupons, average fracture strength should be greater than 40 megapascals. Aggregate, polycrystalline elastic constants are Epoly 131 gigapascals, vpoly 0.22.

fracture toughness↗

Synthesis and characterization of a cadmium germanium phosphate CdGe(OH){sub 3}PO{sub 4} with an open framework

A new three-dimensional (3D) framework cadmium germanium phosphate, CdGe(OH){sub 3}PO{sub 4} was synthesized by solvothermal methods. The crystal structure of CdGe(OH){sub 3}PO{sub 4} was established by single-crystal X-ray diffraction: CdGeH{sub 3}O{sub 7}P, Orthorhombic, Cmca, a=7.1415(7) A, b=10.9034(1) A, c=13.1098(1) A, Z=8, R{sub 1}=0.0365 (F{sup 2}>2{sigma}(F{sup 2}) and wR{sub 2}=0.0985 (all data). The framework of CdGe(OH){sub 3}PO{sub 4} is built by a mixed network of GeO{sub 6}, CdO{sub 6} octahedra and PO{sub 4} tetrahedra, which are linked to form a 3-membered ring (3-MR). The GeO{sub 6} and CdO{sub 6} octahedra share common vertexes and edges, respectively, to form one-dimensional (1D) Ge-O-Ge and Cd-O-Cd chains, which are further connected forming corrugated Ge-O-Cd layers. The layers are linked by PO{sub 4} tetrahedra, leading to a 3D open-framework structure with 3- and 6-MR channels. - Graphical abstract: A new three-dimensional framework cadmium germanium phosphate, CdGe(OH){sub 3}PO{sub 4} was synthesized by solvothermal methods. The framework of CdGe(OH){sub 3}PO{sub 4} is built by a mixed network of GeO{sub 6} octahedra, CdO{sub 6} octahedra and PO{sub 4} tetrahedra and contains a network of one-dimensional 3 and 6-membered ring channels. It belongs to a class of metal germanium phosphates with an open framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation into Methods to Improve Ion Source Life for Germanium Implantation

Germanium tetrafluoride has long been the standard dopant gas of choice for germanium implantation processes. While this material maintains several positive attributes (e.g., it is a nonflammable gas that is easily delivered to an ion source), its use can result in extremely short ion source lifetimes. This is especially the case for the situation when an ion implanter runs solely or predominantly GeF{sub 4}. Presented here is an examination of various potential solutions to the short source life problem, some of which enable significant improvement.

36 MATERIALS SCIENCE↗

The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

The observation of neutrinoless double-beta decay would determine whether the neutrino is a Majorana particle and provide information on the absolute scale of neutrino mass. The MAJORANA Collaboration is constructing the DEMONSTRATOR, an array of germanium detectors, to search for neutrinoless double-beta decay of 76Ge. The DEMONSTRATOR will contain 40 kg of germanium; up to 30 kg will be enriched to 86% in 76Ge. The DEMONSTRATOR will be deployed deep underground in an ultra-low-background shielded environment. Operation of the DEMONSTRATOR aims to determine whether a future tonne-scale germanium experiment can achieve a background goal of one count per tonne-year in a 4-keV region of interest around the 76Ge neutrinoless double-beta decay Q-value of 2039 keV.

Schubert, Alexis G.↗

Atomic layer deposition of energy band tunable tin germanium oxide electron transport layer for the SnS-based solar cells with 400 mV open-circuit voltage

Tin germanium oxide, (Sn,Ge)O 2 , films were prepared using atomic layer deposition and tailored to a SnS absorber layer by incorporating various amounts of germanium into tin oxide to adjust band alignments at the interfaces of SnS/(Sn,Ge)O 2 photovoltaic devices. Carrier concentrations of (Sn,Ge)O 2 were suppressed from 10 20 to 10 18 cm -3 with germanium incorporation, with nitrogen doping further reducing carrier concentrations by another order of magnitude. Excellent tunability of both band energy levels and carrier concentrations of (Sn,Ge)O 2 allowed optimizing SnS-based solar cells. SnS/(Sn,Ge)O 2 :N devices were demonstrated, with an open-circuit voltage as high as 400 mV, due to the effective mitigation of interfacial recombination of photogenerated carriers at the SnS/(Sn,Ge)O 2 :N absorber-buffer heterojunction interface.

Sulfur compounds↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Simulations for Tracking Cosmogenic Activation in Germanium and Copper

High-purity germanium (HPGe) detectors housed in copper cryostats and shielding materials are used in measurements of the extraordinarily rare nuclear decay process, neutrinoless double-beta decay (0νββ), and for dark matter searches. Cosmogenic production of 68Ge and 60Co in the germanium and copper represent an irreducible background to these experiments as the subsequent decays of these isotopes can mimic the signals of interest. These radioactive isotopes can be removed by chemical and/or isotopic separation, but begin to grow-in to the material after separation until the material is moved deep underground. This work is motivated by the need to have a reliable, experimentally benchmarked simulation tool for evaluating shielding materials used during transportation and near-surface manufacturing of experiment components. The resulting simulations tool has been used to enhance the effectiveness of an existing transport shield used to ship enriched germanium from the separations facility to the detector manufacturing facility.

Aguayo, Estanislao↗

Electrolytic Etching of Germanium Substrates with Hydrogen Peroxide

Anodic electrolytic etching of germanium has been performed in hydrogen peroxide etchants with controlled external conditions. In-situ current and ex-situ etch-depths were measured and tracked with respect to etchant composition and stir rates. Gas bubbles formed during the etching process were found to cause non-uniformity in etch-current and surface quality. The effects were minimized in specific composition spaces. Quantitative analysis revealed a linear correlation of the number of electrons transferred during germanium oxidation with the number of surface atoms removed. Experimental results of 2.77 electrons/atom deviate significantly from 4 electrons/atom previously reported for silicon. The conclusion is that etching mechanisms for germanium are sufficiently different from those for silicon which invalidates the direct transfer of processing techniques between the two materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the Cycling Life of Aluminum and Germanium Thin Films for use as Anodic Materials in Li-Ion Batteries.

The cycling of high-capacity electrode materials for lithium-ion batteries results in significant volumetric expansion and contraction, and this leads to mechanical failure of the electrodes. To increase battery performance and reliability, there is a drive towards the use of nanostructured electrode materials and nanoscale surface coatings. As a part of the Visiting Faculty Program (VFP) last summer, we examined the ability of aluminum oxide and gold film surface coatings to improve the mechanical and cycling properties of vapor-deposited aluminum films in lithium-ion batteries. Nanoscale gold coatings resulted in significantly improved cycling behavior for the thinnest aluminum films whereas aluminum oxide coatings did not improve the cycling behavior of the aluminum films. This summer we performed a similar investigation on vapor-deposited germanium, which has an even higher theoretical capacity per unit mass than aluminum. Because the mechanism of lithium-alloying is different for each electrode material, we expected the effects of coating the germanium surface with aluminum oxide or gold to differ significantly from previous observations. Indeed, we found that gold coatings gave only small or negligible improvements in cycling behavior of germanium films, but aluminum oxide (Al 2 O 3 ) coatings gave significant improvements in cycling over the range of film thicknesses tested.

36 MATERIALS SCIENCE↗

Two-Dimensional Spatial Imaging of Charge Transport in Germanium Crystals at Cryogenic Temperatures

In this dissertation, I describe a novel apparatus for studying the transport of charge in semiconductors at cryogenic temperatures. The motivation to conduct this experiment originated from an asymmetry observed between the behavior of electrons and holes in the germanium detector crystals used by the Cryogenic Dark Matter Search (CDMS). This asymmetry is a consequence of the anisotropic propagation of electrons in germanium at cryogenic temperatures. To better model our detectors, we incorporated this effect into our Monte Carlo simulations of charge transport. The purpose of the experiment described in this dissertation is to test those models in detail. Our measurements have allowed us to discover a shortcoming in our most recent Monte Carlo simulations of electrons in germanium. This discovery would not have been possible without the measurement of the full, two-dimensional charge distribution, which our experimental apparatus has allowed for the first time at cryogenic temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the low-energy germanium quenching factor with a small-mass detector

We report on work performed to measure the quenching factor of low kinetic energy germanium recoils, as a collaboration between Sandia National Laboratories (SNL) and Duke University. A small-mass low-noise high purity germanium detector was irradiated by a mono-energetic pulsed neutron beam produced by the Triangle Universities Nuclear Laboratory (TUNL) Van-de-Graaff accelerator. Data was collected to determine the germanium quenching factor as a function of 10 discrete recoil energy values in the range ~ [0.8, 5.0] keVnr. We describe the experiment, present the simulation and data processing for the 10 datasets, and discussed the quenching factor analysis result for one of them. This one result seems to indicate a somewhat large deviation from literature values, though it is still preliminary to claim the presence of a systematic bias in our data or analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel Array Germanium Detectors for Nuclear Physics (Final Technical Report)

The Department of Energy (DOE) Office of Nuclear Physics supports the development and maintenance of germanium gamma-ray detector arrays at national laboratories and universities. Germanium gamma-ray detectors provide state-of-the-art gamma-ray energy resolution, making them critical for gamma-ray and x-ray spectroscopy in Nuclear Physics. Furthermore, detector segmentation and charge-signal waveform processing enables 3-dimensional (3D) measurement of gamma-ray interaction locations needed for the highest-fidelity Nuclear Physics experiments. Attaining and maintaining excellent gamma-ray energy resolution depends largely on the naturally excellent charge-collection properties of germanium crystals. However, the optimal method for achieving the best practical 3D spatial resolution within the detector volume at high counting rates is less clear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

Segmented Monolithic Germanium Detector Arrays for X-ray Absorption Spectroscopy

The experimental results from the Phase I effort were extremely encouraging. During Phase I PHDs Co. made the first strides toward a new detector technology that could have great impact on synchrotron x-ray absorption (XAS) measurements, and x-ray detector technology in general. Detector hardware that allowed critical demonstration measurements of our technology was designed and fabricated. This new technology allows good charge collection from many pixels on a single side of a multi-element monolithic germanium planar detector. The detector technology provides “dot-like” collection electrodes having very low capacitance. The detector technology appears to perform as anticipated in the Phase I proposal. In particular, the 7-pixel detector studied showed remarkable properties; making it an interesting example of detector physics. The technology is enabled by the use of amorphous germanium contact technology on germanium planar detectors. Because of the scalability associated with the fabrication of these technologies at PHDs Co., we anticipate being able to supply larger detector systems at significantly lower cost than systems made in the conventional manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon-germanium technology program of the Jet Propulsion Laboratory.

The outer planetary exploration missions studied by the Jet Propulsion Laboratory require silicon-germanium radioisotope thermoelectric generators (RTGs) in which the factors of safety are as low as is compatible with the reliable satisfaction of the power needs. Work on silicon germanium sublimation performed at the Jet Propulsion Laboratory is presented. Analytical modeling work on the solid-diffusion process involved in the steady-state (free) sublimation of silicon germanium is described. Analytical predictions are made of the sublimation suppression which can be achieved by using a cover gas. A series of accelerated (high-temperature) tests which were performed on simulated hardware (using four SiGe couples) to study long-term sublimation and reaction mechanisms are also discussed.

De Winter, F.↗

The solar abundance of germanium

Spectral scans of the wavelength regions around 3039 A and 3269 A were used as a basis for the determination of the solar abundance of germanium. A solar model similar to the one given by Elste (1968) was used in the analysis of the data. The germanium abundance values obtained are presented in a table. Taking into account an abundance compilation for the solar system conducted by Cameron (1973), it is concluded that the 'solar system' and solar atmospheric abundances of germanium are in accord.

Ross, J. E.↗

Capabilities of germanium detectors

The gamma ray detection efficiency and energy resolution of germanium detectors is reviewed. A general sensitivity equation for gamma-ray detectors is presented and calculated sensitvity curves are shown for a large volume balloon-borne spectrometer using germanium detectors. Improvement anticipated from a planned satellite experiment using germanium detectors is discussed.

Willett, J. B.↗