There’s no Stopping Geothermal Energy: Join the Movement to Re-Energize your Field
None
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
None
Abstract not provided
This dataset contains shapefiles and rasters that summarize the results of a stochastic analysis of temperatures at depth in the Appalachian Basin states of New York, Pennsylvania, and West Virginia. This analysis provides an update to the temperature-at-depth maps provided in the Geothermal Play Fairway Analysis of the Appalachian Basin (GPFA-AB) Thermal Quality Analysis (GDR repository 879: https://gdr.openei.org/submissions/879). This dataset improves upon the GPFA-AB dataset by considering several additional uncertainties in the temperature-at-depth calculations, including geologic properties and thermal properties. A Monte Carlo analysis of these uncertain properties and the GPFA-AB estimated surface heat flow was used to predict temperatures at depth using a 1-D heat conduction model. In this data submission, temperatures are provided for depths from 1-5 km in 0.5 km increments. The mean, standard deviation, and selected quantiles of temperatures at these depths are provided as shapefiles with attribute tables that contain the data. Rasters are provided for the mean and standard deviation data. Figures and maps that summarize the data are also provided. For the pixel corresponding to Cornell University, Ithaca, NY, a .csv file containing the 10,000 temperature-depth profiles estimated from the Monte Carlo analysis is provided. These data are summarized in a figure containing violin plots that illustrate the probability of obtaining certain temperatures at depths below Cornell.
Novel, direct-energy drilling technologies such as electro-pulse boring, have the potential to significantly increase the speed and depth of geothermal drilling but have not achieved widespread adoption due to several economic and technical barriers. One major challenge is that these drilling systems require electric power downhole. The current practice is to supply power to the drill string components by running electric cables down the geothermal well, but at the targeted well depths, this practice is cost-inhibitive, inefficient in terms of power consumption, and adds an additional failure point with the long cabling going through a highly corrosive, high-temperature environment. A solution to this problem is to develop high-temperature electric generator technology that can generate the required power downhole. Such a generator must also operate with high efficiency at the target downhole ambient temperature of 250 °C. In this paper, we investigate the various design considerations for this concept and subsequently design the downhole electric generator using a multi-objective design optimization approach. Through electromagnetic-, thermal- and short-circuit fault condition analysis, it is demonstrated that the optimized downhole electric generator concept presented in this paper can meet the performance requirements within this extreme drilling environment. Most remarkably, it is shown that a generator efficiency of 90% is achieved. In conclusion, to validate the results presented in this paper, a prototype generator is built and its performance is measured at 250 °C using a test bench uniquely developed for this application.
This purpose of this set of entries is to group together the materials and analytical methods used in the assessment of the natural rock properties within and surrounding two potential reservoirs.
Abstract not provided
Abstract not provided
Abstract not provided
Abstract not provided
The purpose of this project is to provide an energy efficient and environmentally friendly heating and air conditioning using a geothermal system.
This spreadsheet allows the user to calculate parameters relevant to techno-economic performance of a two-step absorption process to transport low temperature geothermal heat some distance (1-20 miles) for use in building air conditioning. The parameters included are (1) energy density of aqueous LiBr and LiCl solutions, (2) transportation cost of trucking solution, and (3) equipment cost for the required chillers and cooling towers in the two-step absorption approach. More information is available in the included public report: "A Technical and Economic Analysis of an Innovative Two-Step Absorption System for Utilizing Low-Temperature Geothermal Resources to Condition Commercial Buildings"
For the past quarter, we have placed our effort in implementing the first version of the Model-Based Iterative Reconstruction (MBIR) algorithm, assembling and testing the electronics, designing transducers mounts, and defining our laboratory test samples. We have successfully developed the first implementation of MBIR for ultrasound imaging. The current algorithm was tested with synthetic data and we are currently making new modifications for the reconstruction of real ultrasound data. Beside assembling and testing the electronics, we developed a LabView graphic user interface (GUI) to fully control the ultrasonic phased array, adjust the time-delays of the transducers, and store the measured reflections. As part of preparing for a laboratory-scale demonstration, the design and fabrication of the laboratory samples has begun. Three cement blocks with embedded objects will be fabricated, characterized, and used to demonstrate the capabilities of the system. During the next quarter, we will continue to improve the current MBIR forward model and integrate the reconstruction code with the LabView GUI. In addition, we will define focal laws for the ultrasonic phased array and perform the laboratory demonstration. We expect to perform laboratory demonstration by the end of October 2015.
Rapid expansion of U.S. geothermal capacity is opening new job opportunities across the nation. With more than 3,000 megawatts (MW) already installed, the United States leads the world in existing geothermal capacity.
Direct lithium extraction (DLE) of brines after geothermal power production offers opportunities to produce environmentally benign “green” lithium; however, some environmental impact is inevitable. We examined solid waste production at geothermal power plants in southern California that are also locations for planned DLE facilities. Currently, the geothermal plants in this region produce approximately 79,800 metric tons (wet weight) per year of solid waste, which represents about 28 metric tons per GWh of net electricity production or approximately 500 mg solids per kg geothermal brine. Approximately 15% of this waste requires management as hazardous waste. Solids produced during power production represent about 0.2% of the total dissolved solids in the brine. Lithium production will require the removal of silica, iron, and other metals as part of the DLE process. Using a mass balance approach, we calculate that precipitation of silica and metals could produce up to an additional 6800 mg solids per kg brine. Calcium occurs at very high concentrations, and the amount of solids disposed in landfills will be dependent on the amount of calcium removed during lithium recovery. Our analysis shows that evaluation of brine chemistry in the context of the DLE process is useful for evaluating the potential solid waste impacts of producing lithium from brines.
Several cost estimation and financial cash flow models have been applied to a series of geothermal case studies. In order to draw conclusions about relative performance and applicability of these models to geothermal projects, the consistency of results was assessed. The model outputs of principal interest in this study were net present value, internal rate of return, or levelized breakeven price. The models used were VENVAL, a venture analysis model; the Geothermal Probabilistic Cost Model (GPC Model); the Alternative Power Systems Economic Analysis Model (APSEAM); the Geothermal Loan Guarantee Cash Flow Model (GCFM); and the GEOCOST and GEOCITY geothermal models. The case studies to which the models were applied include a geothermal reservoir at Heber, CA; a geothermal eletric power plant to be located at the Heber site; an alcohol fuels production facility to be built at Raft River, ID; and a direct-use, district heating system in Susanville, CA.
GEOPHIRES is a software tool to investigate technical and economic performance of a geothermal system. Possible end-use options are electricity, direct-use heat and co-generation.