Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Final Closeout Meeting Presentation [Slides]
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This paper summarizes the risk assessment and management workflow developed and applied to the Southwest Regional Partnership on Carbon Sequestration (SWP) Phase III Demonstration Project. The risk assessment and management workflow consists of six primary tasks, including management planning, identification, qualitative analysis, quantitative analysis, response planning, and monitoring. Within the workflow, the SWP assembled and iteratively updated a risk registry that identifies risks for all major activities of the project. Risk elements were ranked with respect to the potential impact to the project and the likelihood of occurrence. Both qualitative and quantitative risk analyses were performed. To graphically depict the interactions among risk elements and help building risk scenarios, process influence diagrams were used to represent the interactions. The SWP employed quantitative methods of risk analysis including Response Surface Method (RSM), Polynomial Chaos Expansion (PCE), and the National Risk Assessment Partnership (NRAP) toolset. The SWP also developed risk response planning and performed risk control and monitoring to prevent the risks from affecting the project and ensure the effectiveness of risk management. As part of risk control and monitoring, existing and new risks have been tracked and the response plan was subsequently evaluated. Findings and lessons learned from the SWP’s risk assessment and management efforts will provide valuable information for other commercial geological CO2 storage projects.
The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.
The objective of the project was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO 2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO 2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The industrial host site emits approximately 3 million tonnes CO 2 /year based on plant data from 2020-2022. The captured CO 2 will meet the requirements of transport (Pipeline Grade) and geological storage, and the geological storage facilities within 80 miles of the CO 2 source. The impact of the project on Environmental Justice and the regional economy was also analyzed.
Successful geologic CO 2 storage projects depend on numerical simulations to predict reservoir performance during site selection, injection verification, and post-injection monitoring phases of the project. These numerical simulations solve non-linear sets of coupled partial differential equations, while accounting for multi-phase fluid dynamics on the basis of constitutive equations that are embedded into the solution scheme. As a consequence, individual simulations often require tens to hundreds of hours to complete on high-performance computing clusters. Moreover, laboratory experiments reveal that parametric functions for capillary pressure and relative permeability exhibit substantial variability, even within the same rock type. This combination of computational expense and wide-ranging parametric variability means that there remains substantial uncertainty in the behavior of multi-phase CO 2 -water systems, particularly in the context of feedbacks between relative permeability and capillary pressure. To bridge this knowledge gap, here we develop a novel workflow that utilizes physics-based numerical simulation to train an artificial neural network (ANN) emulator for interrogating the multivariate parameter space that governs both capillary pressure and relative permeability. With this approach, the ANN is trained to emulate both fluid pressure distribution and CO 2 saturation, which are then interrogated quantitatively to generate parametric response surface mappings with high-fidelity resolution. Results from this study initially show that capillary entry pressure is the dominant control on both CO 2 plume geometry and fluid pressure propagation when considering the combined effects of capillary pressure and relative permeability, particularly when phase interference is low and residual CO 2 saturation is high. Moreover, the ANN emulator provides tremendous computational speed-up by computing 2691 individual simulations in several minutes; whereas, the same simulation ensemble would have required ~3 years of simulation time using only physics-based simulation methods (25,000 times speed up).
The ongoing CCUS commercial projects are highly relied on the support of government incentives due to massive capital investment. Here, this study analyzes the economics of carbon capture utilization and sequestration (CCUS) projects, shows a state-wide CCUS deployment exercise, followed by simulation results of enhanced oil recovery (EOR) based CO 2 storage in unconventional reservoirs. The comprehensive economic analysis of capture, transportation, sequestration costs, enhanced 45Q tax credits, and EOR revenue implies the practicality of CO 2 -EOR to offset the high CCUS costs. With the economics understanding, we study the top CO 2 sources, existing CO 2 pipelines, and sequestration sinks in the state of Colorado, USA. This paper next presents results from EOR simulation in one section of the unconventional Denver-Julesburg (DJ) Basin Niobrara and Codell reservoirs. The simulation model is based on a geological static model, incorporated with hydraulic fracture stimulation, history matched to production, and calibrated to the microseismic and time-lapse surface seismic data. The CO 2 -EOR simulation results show that oil production can be increased and more CO 2 stored with: a longer primary production period; the presence of a shut-in period; higher injection rates; and multi-well injectors. The modeling results show that about 7–10 Mscf of CO 2 will be stored when recovering 1 stb of EOR oil. By adding the enhanced oil revenue and the carbon credits together, it is estimated that the most economic case can generate $\$13$ MM when oil price is assumed to be $\$80$/stb, and the EOR oil revenue is 3.4 times greater than that generated from 45Q incentives. It corresponds to the scenario that a five-year primary production is followed by CO 2 injection into four wells with the sequence of injection (4 MMscf/day for 6 months), shut-in (6 months) and production (12 months). The best practices in this study will provide valuable insights for similar CCUS projects in other unconventional fields. Furthermore, this study defines a term named “Carbon Neutrality Index (CNI)” by comparing the amount of CO 2 stored with that burned by EOR oil. The CNI value of 0 indicates the enhanced oil is carbon neutral; a negative CNI value implies there is a net reduction in carbon emission. The 4-year huff-n-puff (HnP) simulation leads to a positive CNI value, indicating that the EOR oil generated in this process is not carbon neutral yet.
This paper summarizes the results of the risk analysis and characterization of the CO 2 and brine leakage potential of Farnsworth Unit (FWU) site wells. The study is part of the U.S. DOE’s National Risk Assessment Partnership (NRAP) program, which aims to quantitatively evaluate long-term environmental risks under conditions of significant geologic uncertainty and variability. To achieve this, NRAP utilizes risk assessment and computational tools specifically designed to quantify uncertainties and calculate the risk associated with geologic carbon dioxide (CO 2 ) sequestration. For this study, we have developed a workflow that utilizes physics-based reservoir simulation results as input to perform leakage calculations using NRAP Tools, specifically NRAP-IAM-CS and RROM-Gen. These tools enable us to conduct leakage risk analysis based on ECLIPSE reservoir simulation results and to characterize wellbore leakage at the Farnsworth Unit Site. We analyze the risk of leakage from both individual wells and the entire field under various wellbore integrity distribution scenarios. The results of the risk analysis for the leakage potential of FWU wells indicate that, when compared to the total amount of CO 2 injected, the highest cemented well integrity distribution scenario (FutureGen high flow rate) exhibits approximately 0.01% cumulative CO 2 leakage for a 25-year CO 2 injection duration at the end of a 50-year post-injection monitoring period. In contrast, the highest possible leakage scenario (open well) shows approximately 0.1% cumulative CO 2 leakage over the same time frame.
This study was conducted as part of the Southwest Regional Partnership on Carbon Sequestration (SWP) project to evaluate how upscaling fine-scale simulation models to coarse-scale simulation models impacted the results. The focus was on the Farnsworth Unit (FWU) and its Morrow' B' Sandstone reservoir, specifically the west half of the field. Due to data limitations and the geologic characteristics of the surrounding area, the upscaling was limited to the west half of the FWU rather than a broader basinscale model. The primary aim was to explore how upscaling impacts numerical simulation models, particularly regarding CO 2 -enhanced oil recovery (EOR) and storage capacity predictions. Upscaling was necessary to reduce computational demands when transitioning from high-resolution geological models to coarser grids, as large-scale simulations with finer grids can be computationally prohibitive. This study expands on previous work by the SWP to understand how additional upscaling, applied to already fine-scale numerical simulation models, affects reservoir performance simulations (Ampomah, Balch, & Grigg, 2015). This is key to understanding how loss of resolution can affect coarsescale model results that may be used for large sensitivity analyses, uncertainty quantifications, and training data for machine learning applications.
Saline formations are attractive geologic reservoirs for permanent carbon dioxide (CO 2 ) storage. Here, the U.S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) has worked to develop and refine methods and tools for the calculation of CO 2 storage potential in subsurface reservoirs. DOE-NETL's CO 2 -SCREEN provides an online tool for executing these storage methods. CO 2 storage efficiency terms are input parameters in DOE-NETL's methods and equations embedded in the CO 2 -SCREEN, which assesses pore space available for CO 2 storage. In this work, a modeling workflow was initiated to refine two CO 2 storage efficiency terms - volumetric displacement (E V ) and microscopic displacement (E d ). The models are based on new experimental relative permeability data that are specific to homogenous lithology and depositional environments of key subsurface saline formations targeted for CO 2 storage. In future work, heterogenous features will be added to this initial modeling effort to update efficiency factors as described in DOE-NETL's methods and CO 2 -SCREEN tool. E V accounts for the volume utilized in the reservoir under the areal plume, while E d accounts for saturation values in the plume to assess efficiency of CO 2 storage at the pore scale. The results of this work are significant in that prior values were based on a limited geologically non-specific relative permeability data set that were collected prior to 2009. Specifically, we applied numerical simulations using TOUGH3 models to update CO 2 storage efficiency values for supercritical CO 2 injection into brine-saturated reservoirs for three lithologies (clastics, limestone, dolomite) and six depositional environments (Marginal Marine, Strand Plain, Deltaic Complex Fluvial, Aeolian, Shallow Marine, and Reef) that have a high potential for geologic CO 2 storage. Experimental relative permeability data in cores from these environments were utilized in the models with corresponding rock type/sedimentary environment. Results of this study showed that dolomite followed by limestone generated higher ranges of storage efficiency compared to clastics. The updated values provided a tighter efficiency range for clastics, lower P 10 but higher P 90 range for limestone, and higher P 10 and P 90 for dolomite. In general, tighter reservoirs with relatively low permeability and porosity were associated with higher E V and E d , showing efficient reservoir and pore utilization in these scenarios. High reservoir pressure and temperature associated with increasing depth increased the E V , and high CO 2 injection rates resulted in increases in E V and E d , while the impact of permeability anisotropy was minimal after the 30-year injection period.
Geologic carbon sequestration (GCS) is a promising technology for mitigating net carbon emissions and growing climate concern by storing CO 2 in reservoirs. Oil and gas brownfields are an attractive option for CO 2 storage, but these sites have many historical wellbores from petroleum production and can be a potential leakage pathway for CO 2 or formation brine. Therefore, risk management of GCS operations requires an assessment of potential well leakage. Due to the high uncertainty of the system, stochastic approaches are ideal for quantifying the range of risk behaviors, but they must be computationally efficient in the face of complex physics. Here, we develop a new physics-centric deep learning wellbore model to predict the leakage of CO 2 and brine through leaky wellbores. Multi-physics numerical simulations were used to generate data sets, and physics-informed features were introduced. Neural networks were optimized with an automated searching algorithm. Feature analysis quantifies the impact of each feature on model prediction and confirms the role of physics-inspired parameters. The model shows high predictive performance across a wide range of geologic and injection conditions and well attributes. In conclusion, a case study illustrates how the model is applied to assess well leakage in GCS operations.
In geophysical inversions, lower and upper model parameter bounds are a means of solution stabilization. Further, constraints that intend to let only geologically plausible inverse solutions pass are amenable to lower and upper bounds. Reliable prior information is paramount to construct such bound constraints. It is common practice to narrow and widen bound intervals for regions of, respectively, more and less certain prior information. Contrary to this practice, we experiment with widened bound intervals in zones that are poorly resolved by a given survey configuration but where prior information would suggest structural anomalies of interest. The purpose of enlarged parameter bounds that correlate spatially with predefined targets is to let the inversion explore a larger solution space, thus increasing the potential to resolve otherwise hidden anomalies. Application of the method is based on a carbon-sequestration baseline (pre-injection) crosswell electromagnetic (EM) field survey at the Containment and Monitoring Institute Field Research Station (Alberta, Canada), where impeded measurements led to generally reduced sensitivities for the interwell region. Synthetic-data proofs of concept use augmented bounds designed to boost the resolution of artificial plume targets, indicating an enhanced illumination compared to constant bounds. Comparative field data inversions with spatially variable bounds constructed from prior resistivity and velocity information highlight non-horizontal baseline structures.
Energy system planning tools suggest that the cost and feasibility of climate-stabilizing energy transitions are sensitive to the cost of CO 2 capture and storage processes (CCS), but the representation of CO 2 transportation and geologic storage in these tools is often simple or non-existent. We develop the capability of producing dynamic-reservoir-simulation-based geologic CO 2 storage supply curves with the Sequestration of CO 2 Tool (SCO 2 T) and use it with the ReEDS electric sector planning model to investigate the effects of CO 2 transportation and geologic storage representation on energy system planning tool results. We use a locational case study of the Electric Reliability Council of Texas (ERCOT) region. Our results suggest that the cost of geologic CO 2 storage may be as low as $3/tCO 2 and that site-level assumptions may affect this cost by several dollars per tonne. At the grid level, the cost of geologic CO 2 storage has generally smaller effects compared to other assumptions (e.g., natural gas price), but small variations in this cost can change results (e.g., capacity deployment decisions) when policy renders CCS marginally competitive. The cost of CO 2 transportation generally affects the location of geologic CO 2 storage investment more than the quantity of CO 2 captured or the location of electricity generation investment. We conclude with a few recommendations for future energy system researchers when modeling CCS. For example, assuming a cost for geologic CO 2 storage (e.g., $5/tCO 2 ) may be less consequential compared to assuming free storage by excluding it from the model.
Carbon dioxide (CO 2 ) sequestration has garnered widespread attention as a key strategy for mitigating CO 2 emissions and combating the greenhouse effect. However, the mechanisms underlying the interactions between CO 2 , widespread siliceous minerals and biological processes remain unclear. The present study explored the potential impacts of different CO 2 concentrations on microbial activity, environmental conditions and their feedback on the fate of CO 2 . A total of 20 experimental conditions was created, with the variables including different natural and synthetic siliceous minerals (e.g., quartz sand and a type of commercial glass beads), the presence or absence of the iron-reducing microorganism Orenia metallireducens (strain Z6) and varying CO 2 concentrations (0%, 20%, 50%, 100%) in the presence of ferrihydrite and pyruvate. Geochemical, microbial and mineralogical analyses revealed that elevated CO 2 concentrations significantly inhibited microbial Fe(III) reduction and pyruvate metabolism. Interestingly, compared to cultures without mineral amendments or those with glass beads alone, the addition of quartz sand enabled strain Z6 to better withstand the environmental stress caused by elevated CO 2 , promoting pyruvate fermentation and iron reduction. In addition to an increased pH, the formation of siderite, hematite and vivianite was also observed in the bioactive systems. Although both glass beads and quartz sand were primarily composed of silica, differences in the mineral structure, elemental composition and acid neutralization capacity rendered quartz sand more chemically active and unexpectedly led to greater CO 2 sequestration.
In 2013, the Pacific Northwest National Laboratory led a geologic carbon sequestration field demonstration where ~1000 tonnes of CO 2 was injected into several deep Columbia River Basalt zones near Wallula, Washington. Rock core samples extracted from the injection zone two years after CO 2 injection revealed nascent carbonate mineralization that was qualitatively consistent with expectations from laboratory experiments and reactive transport modeling. In this study, we report on a new detailed analysis of the 2012 pre-injection and 2015 post-injection hydrologic tests that capitalizes on the difference in fluid properties between scCO 2 and water to assess changes in near-field, wellbore, and reservoir conditions that are apparent approximately two years following the end of injection. This comparative hydrologic test analysis method provides a new way to quantify the amount of injected CO 2 that was mineralized in the field test. Modeling results indicate that approximately 60% of the injected CO 2 was sequestered via mineralization within two years, with the resulting carbonates occupying ~4% of the available reservoir pore space. The method presented here provides a new monitoring tool to assess the fate of CO 2 injected into chemically reactive basalt formations but could also be adapted for long-term monitoring and verification within more traditional subsurface carbon storage reservoirs.
Offshore geological sequestration of CO 2 offers a viable approach for reducing greenhouse gas emissions into the atmosphere. Strategies include injection of CO 2 into the deep-ocean or ocean-floor sediments, whereby depending on pressure–temperature conditions, CO 2 can be trapped physically, gravitationally, or converted to CO 2 hydrate. Energy-driven research continues to also advance CO 2 -for-CH 4 replacement strategies in the gas hydrate stability zone (GHSZ), producing methane for natural gas needs while sequestering CO 2 . In all cases, safe storage of CO 2 requires reliable monitoring of the targeted CO 2 injection sites and the integrity of the repository over time, including possible leakage. Electromagnetic technologies used for oil and gas exploration, sensitive to electrical conductivity, have long been considered an optimal monitoring method, as CO 2 , similar to hydrocarbons, typically exhibits lower conductivity than the surrounding medium. We apply 3D controlled-source electromagnetic (CSEM) forward modeling code to simulate an evolving CO 2 reservoir in deep-ocean sediments, demonstrating sufficient sensitivity and resolution of CSEM data to detect reservoir changes even before sophisticated inversion of data. Laboratory measurements place further constraints on evaluating certain systems within the GHSZ; notably, CO 2 hydrate is measurably weaker than methane hydrate, and >1 order of magnitude more conductive, properties that may affect site selection, stability, and modeling considerations.
Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.
Sedimentary basins are naturally porous and permeable subsurface formations that underlie approximately half of the United States. In addition to being targets for geologic CO 2 storage, these resources could supply geothermal power: sedimentary basin geothermal heat can be extracted with water or CO 2 and used to generate electricity. The geothermal power potential of these basins and the accompanying implication for geologic CO 2 storage are, however, understudied. Here, we use the Sequestration of CO 2 Tool (SCO2T PRO ) and the generalizable GEOthermal techno-economic simulator (genGEO) to address this gap by a) estimating the cost and capacity of sedimentary basin geothermal power plants across the United States and b) comparing those results to nationwide CO 2 sequestration cost and storage potential estimates. We find that across the United States, using CO 2 as a geothermal heat extraction fluid reduces the cost of sedimentary basin power compared to using water, and some of the lowest cost capacity occurs in locations not typically considered for their geothermal resources (e.g., Louisiana, South Dakota). Additionally, using CO 2 effectively doubles the sedimentary basin geothermal resource base, equating to hundreds of gigawatts of new capacity, by enabling electricity generation in geologies that are otherwise (with water) too impermeable, too thin, too cold, or not deep enough. We find there is competition for the best sedimentary basin resources between water- and CO 2 -based power, but no overlap between the lowest-cost resources for CO 2 storage and CO 2 -based power. In this way, our results suggest that deploying CO 2 -based power may increase the cost of water based systems (by using the best resources) and the cost of CO 2 storage (by storing CO 2 in locations that otherwise may not be targeted). As such, our findings demonstrate that determining the best role for sedimentary basins within the energy transition may require balancing tradeoffs between competing priorities.
Assuring secure containment of stored CO 2 is of paramount importance—for climate change mitigation, for permitting, and for reassuring the public. Regional seals, such as those sealing petroleum accumulations, have proven to be effective for securing CO 2 . However, the goal of permanent sequestration can also be satisfied with “composite confining systems” consisting of multiple, possibly discontinuous flow barriers that, in aggregate, create a system with very high permeability anisotropy and effectively retard the vertical migration of CO 2 . This study focuses on investigating the barrier characteristics necessary for effective containment of CO 2 , using both physical flow experiments and modified invasion percolation simulations. The simulations are calibrated to the physical experiments and are used to further extend the analysis. Results show that for a composite confining system, a) even barriers with low capillary entry pressure contrast to the underlying flow unit can divert rising CO 2 ; b) curved or anticlinal barrier topography can enhance CO 2 trapping; c) fining-upward gradations make little difference to barrier effectiveness or CO 2 retention; d) longer barriers retain more CO 2 regardless of barrier topography. Finally, field-scale simulations have demonstrated the importance of barrier length for increasing CO 2 storage capacity. Furthermore, the results presented can be used to inform the development of new screening criteria for characterization and effectiveness of composite confining systems.