Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaGe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Strain Gage Loads Calibration Testing with Airbag Support for the Gulfstream III SubsoniC Research Aircraft Testbed (SCRAT)

This paper describes the design and conduct of the strain gage load calibration ground test of the SubsoniC Research Aircraft Testbed, Gulfstream III aircraft, and the subsequent data analysis and its results. The goal of this effort was to create and validate multi-gage load equations for shear force, bending moment, and torque for two wing measurement stations. For some of the testing the aircraft was supported by three air bags in order to isolate the wing structure from extraneous load inputs through the main landing gear. Thirty-two strain gage bridges were installed on the left wing. Hydraulic loads were applied to the wing lower surface through a total of 16 load zones. Some dead weight load cases were applied to the upper wing surface using shot bags. Maximum applied loads reached 54,000 pounds.

trailing edge flap↗

Influence of Strain-Gage Balance Characteristics on the Precision Error of the Drag Coefficient

Improvements and results of a new method are presented that computes a pre-test estimate of the precision error of the drag coefficient of a wind tunnel model. The error estimate is defined as the part of the drag coefficient's precision error that is primarily associated with the precision error of the angle of attack measurement and physical characteristics of the chosen strain-gage balance. The method indirectly describes the precision error of the angle of attack measurement by using an assumed balance gage output variation of one microV/V. The physical characteristics of the balance, on the other hand, are described by partial derivatives of the axial and normal forces with respect to the strain-gage outputs. These derivatives can directly be obtained from the data reduction matrix of the balance. The precision error estimate itself is calculated by applying a simple explicit equation that uses the model reference area, the dynamic pressure, the angle of attack, the coefficients of the linear terms of the data reduction matrix, and the electrical output variation of one microvolt per volt as input. Precision errors at constant angle of attack may be visualized as contour plots by plotting them, for example, versus the Mach number and the total pressure. Characteristics of NASA's MC60E balance are used in combination with the reference area of a generic wind tunnel model in order to demonstrate that error estimates are independent of both the balance load format and the units chosen for the description of balance loads, model reference area, and the dynamic pressure. Finally, experimental data from a wind tunnel test of the Ames Check Standard Model in the NASA Ames 11-foot Transonic Wind Tunnel illustrates the application of the method to real-world test data.

precision error↗

Application of the Concepts of Load State, Load Space, and Output Space to Strain-Gage Balances

The concepts of load state, load space, and output space are used to describe elements of the development of a load prediction process for a six–component strain–gage balance. The use of these terms adds clarity during the selection of the independent and dependent variables for the development of the load prediction process. First, the control volume model of a strain–gage balance is reviewed as it helps better understand the role of loads, outputs, and state variables during the load prediction. Then, the description of the absolute load datum in both the load space and the output space is discussed. It is concluded that the use of the difference between a raw output and the natural zero of a balance gage has a key advantage for the definition of the output space. In that case, the origin of the output space will also describe the absolute load datum of the balance. Finally, details of the application of the concepts of load state, load space, and output space to two commonly used balance load prediction methods are discussed.

strain-gage balance↗

Radiation used to temperature compensate semiconductor strain gages

Exposure to high energy electron radiation reduces the temperature coefficients of resistance and gage factor of a range of resistivities of n- and p-type semiconductor silicon strain gages. After irradiation, the gages are heated to a high temperature for a 24-hour period to stabilize their temperature coefficients.

Gross, C.↗

Coating permits use of strain gage in water and liquid hydrogen

Strain gage installation covered with a three-layer coating of commercial materials makes measurements in water and liquid hydrogen. It consists of a selected foil strain gage bonded with a modified commercial heat-curring epoxy cement. The outer protective layer of the gage installation may develop cracks when immersed in liquid hydrogen.

Berven, B. B.↗

Gage of 6.5 per cent Si-Fe sheet is chemically reduced

Chemical milling process aids the production of 6.5 percent silicon-iron soft magnetic-alloy sheets to very thin gages. Following conventional rolling to safe gage limits, the material is chemically reduced to the desired gage.

Goldman, A.↗

Vacuum gage system for radiation environment

Hot-cathode ionization gages used to measure high-vacuum pressures are subject to error when ionizing radiation is present. Because this radiation creates additional ions, a second ion gage is mounted near the pressure-measuring gage to detect and measure the radiation induced error.

Summers, R. L.↗

Estimating sensitivity of vacuum gages

Gage sensitivity for a particular gas is estimated using the known performance of the gage with a reference gas /nitrogen/ and employing several empirical rules which have usable accuracy. Relative gage sensitivities have been estimated for over 100 gases and vapors.

Summers, R. L.↗

Bileaf mechanical strain gage

Bileaf lever detects small deformations by highly magnifying linear displacements. Device is applicable to force measuring instruments, pressure cells, temperature gages, existing strain gages, dial gages, or extensometers. Additional magnification is obtained by cementing a small mirror to mobile end of bileaf.

Guist, L. R.↗

Static and dynamic load measurements in aerospace decelerator canopy fabrics with metal foil strain gages.

A test program was conducted to determine the feasibility of using conventional metal foil strain gages to measure load-time relationships on thin fabric membranes while these membranes were loaded under simulated aerodynamic decelerator conditions. Uniaxial and biaxial tests were made at fabric strain levels up to about 10%. Loadings were made both statically and dynamically, with the fastest load time being 0.015 second for zero to full load on uniaxial test specimens. For the biaxial tests, plane strain conditions were assumed, and by using experimentally determined strain-load relationships, principal loads were determined from the perpendicularly oriented strain-gage pairs. Although the complex stress-strain behavior of decelerator fabrics prevents the attainment of normally expected strain-gage accuracy, utilization of the techniques described can lead to meaningful measurements for the decelerator stress analyst.

Hoffman, I. S.↗

Commonality Study of the Pressure-Volume-Temperature Based Propellant Gaging Software Modules for the Auxiliary Power Unit, Reaction Control System, and Orbital Maneuvering System

Computer storage requirements can be reduced if areas of commonality exist in two or more programs placed in the same computer and identical code can be used by more than one program. The pressure-volume-temperature (P-V-T) relationship for the propellant tank pressurant agent is utilized as the basis for either a primary of a backup propellant gaging program for the auxiliary power unit (APU), the reaction control system (RCS), and the orbital maneuvering system (OMS). These three propellant gaging programs were investigated. It was revealed that a very limited degree of software commonality exits among them. An examination of this common software indicated that only the computation of the helium compressibility factor in an external function subprogram accessible to both the RCS and OMS propellant gaging programs appears to offer a savings in computer storage requirements.

Duhon, D. D.↗

The use of a simplified structural model as an aid in the strain gage calibration of a complex wing

The use of a relatively simple structural model to characterize the load responses of strain gages located on various spars of a delta wing is examined. Strains measured during a laboratory load calibration of a wing structure are compared with calculations obtained from a simplified structural analysis model. Calculated and measured influence coefficient plots that show the shear, bending, and torsion characteristics of typical strain gage bridges are presented. Typical influence coefficient plots are shown for several load equations to illustrate the derivation of the equations from the component strain gage bridges. A relatively simple structural model was found to be effective in predicting the general nature of strain distributions and influence coefficient plots. The analytical processes are shown to be an aid in obtaining a good load calibration. The analytical processes cannot, however, be used in lieu of an actual load calibration of an aircraft wing.

Jenkins, J. M.↗

High temperature strain gage evaluation

The structural thermal test of an advanced ramjet missile section required strain measurements as high as 922 K (1200 F). Since there is relatively little experience in the use of strain gages above the 700-755 K (800-900 F) level, a program was initiated to select and evaluate the best available gage. Candidate gages suitable for measurements up to 922 K (1200 F) were selected. This involved the determination of their operating characteristics, availability, cost, installation aspects, etc. The evaluation involved the following tests: strain as a function of load at room temperature and apparent strain as a function of temperature.

Gonzalez, J. I.↗

Modified displacement gage for cryogenic testing

Modification of double-cantilever-beam resistance strain gage makes boiling of hydrogen on gage arms less of problem. Modified gages are encapsulated nickel/chromium alloy, and bridge-excitation voltage is reduced from 10 to 1.5 volts. Sensitivity is 1.0 millivolt per inch with 1.5 volt excitation.

Pierce, W. S.↗

An experimental investigation into the feasibility of a thermoelectric heat flux gage

An experiment was conducted to determine the feasibility of using a commerically available thermoelectric device as a heat flux gage. In certain research applications, the thermoelectric heat flux gage can provide a relatively simple means to model a warm fluid--cold wall. The experiment showed that heat flux through the gage could be correlated within two percent to the applied thermoelectric current through the device and the hot and cold side temperature with a simple algebraic equation.

Jones, J. C.↗