Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRAVIMETRIC ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Long term storage test of titanium material with liquid fluorine propellant

The compatibility of 6AL-4V Ti with propellant grade GF2 and LF2 at 77 K for up to 3 years was investigated. Titanium double coupons, annealed or heat treated, with 16 or 64 RMS finishes, were immersed in F2 in individual Pyrex capsules and stored under LN2 for 29 and 39 months. Pre and post immersion tests were performed on the propellant and coupons. Chemical analysis of the propellant did not reveal any significant changes due to titanium corrosion. Gravimetric, visual, microscopic, and metallurgical examination with pitting analysis did not reveal gross corrosion of the titanium although pitting appears to be greater after 39 months exposure. The increase in pit size and number raises the possibility of unpredictable crack propagation instability. Fracture toughness tests are necessary to define this possibility.

Denson, J. R.↗

Synergistic effects in trace gas-aerosol interactions

The reaction of SO2 and NO2 with soot has been studied experimentally by gravimetric determination of chemisorption with subsequent analysis of the chemisorbed species by various techniques. When samples of commercially available carbon black (used as soot surrogate) are exposed to SO2 or NO2 in dry air or N2 as carrier gas, no quantitative chemisorption (less than 5 micrograms per mg of substrate) is observed. However, exposure of the same grade of carbon to a combination of SO2 and NO2 in dry air of N2 results in significant chemisorption (180-200 micrograms/mg), a major fraction of which is analyzed as sulfate.

Schryer, D. R.↗

Microwave Regeneration and Thermal and Oxidative Stability of Imidazolium Cyanopyrrolide Ionic Liquid for Direct Air Capture of Carbon Dioxide

Abstract Understanding the oxidative and thermal degradation of CO 2 sorbents is essential for assessing long‐term sorbent stability in direct air capture (DAC). The potential degradation pathway of imidazolium cyanopyrrolide, an ionic liquid (IL) functionalized for superior CO 2 capacity and selectivity, is evaluated under accelerated degradation conditions to elucidate the secondary reactions that can occur during repetitive absorption‐desorption thermal‐swing cycles. The combined analysis from various spectroscopic, chromatographic, and thermal gravimetric measurements indicated that radical and S N 2 mechanisms in degradation are encouraged by the nucleophilicity of the anion. Thickening of the liquid and gas evolution are accompanied by 50 % reduction in CO 2 capacity after a 7‐day exposure to O 2 under 80 °C. To prevent long exposure to conventional thermal heating, microwave (MW) regeneration of the CO 2 ‐reactive IL is used, where dielectric heating at 80 and 100 °C rapidly desorbs CO 2 and regenerates the IL without any measurable degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An In Situ , multi-electrode electrochemical method to assess the open circuit potential corrosion of Cr in unpurified molten FLiNaK

An in situ electrochemical method to investigate the time-dependent spontaneous corrosion of pure Cr in an unpurified LiF-NaF-KF eutectic salt at 600 °C was developed. A multi-electrode electrochemical cell and a dual-electrode method were utilized to detect Cr(II) and Cr(III) ions on a platinum working electrode using cyclic voltammetry as a function of exposure time and compensating for the distance from the Cr electrode. XRD was performed to characterize the crystalline composition of the exposed FLiNaK and the salt films formed on the working electrodes. The fate of all electro-oxidized Cr must be accounted for to quantify corrosion rates. The concentrations of Cr(II) and Cr(III) species obtained were compared with the gravimetric mass change and ICP-OES analysis of the residual salt. Finally, outcomes, difficulties, and limitations are discussed.

ICP-OES↗

Global detailed geoid computation and model analysis

Comparisons and analyses were carried out through the use of detailed gravimetric geoids which we have computed by combining models with a set of 26,000 1 deg x 1 deg mean free air gravity anomalies. The accuracy of the detailed gravimetric geoid computed using the most recent Goddard earth model (GEM-6) in conjunction with the set of 1 deg x 1 deg mean free air gravity anomalies is assessed at + or - 2 meters on the continents of North America, Europe, and Australia, 2 to 5 meters in the Northeast Pacific and North Atlantic areas, and 5 to 10 meters in other areas where surface gravity data are sparse. The R.M.S. differences between this detailed geoid and the detailed geoids computed using the other satellite gravity fields in conjuction with same set of surface data range from 3 to 7 meters.

Marsh, J. G.↗

Structure, composition and thermal state of the crust in Brazil

Efforts in support of a geomagnetic survey of the Brazilian area are described. Software to convert MAGSAT data tapes to the Burroughs/B-6700 binary format was developed and tested. A preliminary analysis of the first total intensity anomaly map was performed and methodologies for more intensive analysis were defined. The sources for correlative geological, aeromagnetic, and gravimetric data are described.

Pacca, I. I. G.↗

Analysis and geological interpretation of gravity data from GEOS-3 altimeter

A number of detailed gravimetric geoids of portions of the world's oceans from marine gravity measurements were constructed. The geoids were constructed by computing 1 x 1 deg or 10 x 10 deg averages of free-air anomaly data and subtracting these values from currently used satellite derived Earth models. The resulting difference gravity anomalies are then integrated over a sphere using a simplified form of Stoke's equation to obtain a difference geoid. This difference geoid is added to the satellite derived model to obtain a 1 x 1 deg or 10 x 10 deg total gravimetric geoid. The geoid undulations are studied by comparison of the altimeter measurements with the morphology of the ocean floor. Utilizing a combination of altimetry data, gravity and seismic reflection data, geophysical models of the earth can be constructed.

Talwani, M.↗

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational investigation of the impact of metal–organic framework topology on hydrogen storage capacity

Metal–organic frameworks (MOFs) are promising, tunable materials for hydrogen storage. For application under cryogenic operating conditions, past work has run into a ceiling on performance due to a trade-off in the volumetric deliverable capacity (VDC) versus the gravimetric deliverable capacity (GDC). In this study, we computationally constructed and screened 105 230 MOF structures based on 529 nets to explore the effect of underlying topology on the hydrogen storage performance of the resulting materials. A machine learning model was developed based on simulated hydrogen uptake to facilitate screening of the entire dataset, and it successfully identified the top 10% of materials with a root-mean-square error of approximately 1 g L −1 as validated by subsequent grand canonical Monte Carlo simulations. We identified a promising structure based on the tsx topology that exhibits both VDC and GDC higher than the current benchmark material, MOF-5. Our data-driven analysis indicates that nets with higher net density yield MOFs with enhanced volumetric and gravimetric surface areas, thereby improving maximum VDC while shifting the capacity trade-off toward higher GDC.

36 MATERIALS SCIENCE↗

An analysis of ridge axis gravity roughness and spreading rate

Fast and slow spreading ridges have radically different morphologic and gravimetric characteristics. In this study, altimeter measurements from the Geosat Exact Repeat Mission are used to investigate spreading rate dependence of the ridge axis gravity field. Gravity roughness provides an estimate of the amplitude of the gravity anomaly and is robust to small errors in the location of the ridge axis. Gravity roughness as a weighted root mean square of the vertical deflection at 438 ridge crossings on the mid-ocean ridge system is computed. Ridge axis gravity anomalies show a decrease in amplitude with increasing spreading rate up to an intermediate rate of about 60-80 mm/yr and almost no change at higher rates; overall the roughness decreases by a factor of 10 between the lowest and highest rates. In addition to the amplitude decrease, the range of roughness values observed at a given spreading rate shows a similar order of magnitude decrease with transition between 60 and 80 mm/yr. The transition of ridge axis gravity is most apparent at three relatively unexplored locations on the Southeast Indian Ridge and the Pacific-Antarctic Rise; on these intermediate rate ridges the transition occurs abruptly across transform faults.

Small, Christopher↗

Cyclic oxidation evaluation - Approaching application conditions.

Review of 1000 to 1200 C cyclic oxidation testing conducted on potential aircraft gas turbine Ni-, Co-, and Fe-base alloys. Furnace and burner rig testing are discussed, and the results are compared for selected alloys. The alloys fall into two groups, depending on their Cr and Al contents. One group forms mainly Cr2O3/chromite spinel scale(s), while the other forms alpha Al2O3/aluminate spinel scale(s). Spalling on thermal cycling leading to increased metal consumption is associated with the appearance of a chromite spinel. In the case of high-velocity burner rig tests this chromite forming tendency is reinforced by Cr2O3 vaporization depleting Cr in the alloy. In both types of tests, specific weight change is used as an indirect indicator of metal attack, since direct metal loss measurements require destructive analysis. An alternative nondestructive metal loss estimating parameter, based on a tentative mass balance gravimetric approach, shows some potential.

Barrett, C. A.↗

Results from the direct combination of satellite and gravimetric data

Results have been obtained for the solution of 184 15-deg equal-area blocks directly from the analysis of satellite orbits, and from a combination of the satellite results with terrestrial gravity material. This test computation, made to verify the method, used 17,632 optical observations from ten satellites in 29 arcs averaging in length seven days. Analysis of the satellite results were made by comparing the solved for anomalies with the terrestrial anomaly set, and by developing the solved for anomalies into potential coefficients which were compared to the GEM 3 set of potential coefficients to degree 12. These comparisons indicated improvement in each solution as more arcs were added. The programs used in this solution can easily be used to solve for smaller size blocks and handle additional data types. The only limitation will be computer core availability and computer time.

Rapp, R. H.↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The gravimetric geodesy investigation

The Gravimetric Geodesy Investigation which will utilize altimeter and satellite-to-satellite tracking data from GEOS-C, ATS-F, and other spacecraft as appropriate to improve our knowledge of the earth's gravitational field is discussed. This investigation is interrelated with the study of oceanographic phenomena such as those associated with tides and currents, hence the latter are considered together with gravitational effects in the analysis of the data. The oceanographic effects, each of the order of a meter or two in amplitude and with still smaller uncertainties does not seriously hamper the altimeter gravimetric studies at the five meter level. Laser and satellite-to-satellite tracking data, when combined with the altimeter results, should provide the basis for such studies over wide areas of the ocean surface. Laser and conventional geodetic tracking data from ISAGEX and succeeding campaigns will provide a valuable framework for these analyses.

Siry, J. W.↗