Results of aeroheating DFI and ET design-data test on a 0.0175-scale model 60-OTS conducted in the Von Karman Gas Dynamics Facility (VKF) 40" supersonic and the 50" hypersonic wind tunnels A and C
The 0.0175-scale thin-skin thermocouple Model 60-OTS was tested in the von Karman Gas Facility 40-inch continuous flow supersonic tunnel A and the VKF Tunnel C. Testing was conducted at Mach numbers 2.25 to 4.0, and Reynolds numbers from 0.4 x 10 to the 6th power/ft to 6.6 x 10 to the 6th power/ft. Angle of attack range was from -5.0 to +5.0 degrees, and angle of sideslip range was from -6 to +6 degrees. The primary objective of this test was to provide a valid base for the external tank (ET) and solid rocket booster (SRB) heating prediction methodology for ascent flight by taking heating data at Development Flight Instrumentation (DFI) locations for flight conditions simulating STS-1 through -4. A second objective was to obtain additional aeroheating data to support potential reduction of the thermal protection system (TPS) on the ET. The third phase of the test was funded and conducted by NASA/MSFC for the purpose of establishing confidence in the data base from the lower temperature tunnel A.