Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry

Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.

36 MATERIALS SCIENCE↗

The use of gas chromatography – high resolution mass spectrometry for suspect screening and non-targeted analysis of per- and polyfluoroalkyl substances

This study is a workflow development for the analysis, identification, and categorization of per- and polyfluoroalkyl substances (PFAS) using gas chromatography-high resolution mass spectrometry (GC-HRMS) with non-targeted analysis (NTA) and suspect screening techniques. The behavior of various PFAS in a GC-HRMS was studied with regards to retention indices, ionization susceptibility, fragmentation patterns, etc. A custom PFAS database was constructed from 141 diverse PFAS. The database contains mass spectra from electron ionization (EI) mode, as well as MS and MS/MS spectra from positive and negative chemical ionization (PCI and NCI, respectively) modes. Common fragments of PFAS were identified across a diverse set of 141 PFAS analyzed. A workflow for suspect screening of PFAS and partially fluorinated products of incomplete combustion/destruction (PICs/PIDs) was developed which utilized both the custom PFAS database and external databases. PFAS and other fluorinated compounds were identified in both a challenge sample (designed to test the identification workflow) and incineration samples suspected to contain PFAS and fluorinated PICs/PIDs. The challenge sample resulted in a 100% true positive rate (TPR) for PFAS which were present in the custom PFAS database. In conclusion, several fluorinated species were tentatively identified in the incineration samples using the developed workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A statistical analysis of the effects of urease pre-treatment on the measurement of the urinary metabolome by gas chromatography–mass spectrometry

Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Peak Generator for Gas Chromatography

Photoelectric peak generator for repeated reproduction of gas chromatogram peaks while data recording and integration variables are systematically studied

Johnson, R. D.↗

Pioneer Venus gas chromatography of the lower atmosphere of Venus

A gas chromatograph mounted in the Pioneer Venus sounder probe measured the chemical composition of the atmosphere of Venus at three altitudes. Ne, N2, O2, Ar, CO, H2O, SO2, and CO2 were measured, and upper limits set for H2, COS, H2S, CH4, Kr, N2O, C2H4, C2H6, and C3H8. Simulation studies have provided indirect evidence for sulfuric acid-like droplets and support the possibility of water vapor at altitudes of 42 and 24 km. The paper discusses the implications of these results for the origin, evolution, and present state of Venus' atmosphere.

Oyama, V. I.↗

Integration of Gas Chromatography Mass Spectrometry Methods for Differentiating Ricin Preparation Methods

The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of the castor plant Ricinus communis. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatographic - mass spectrometric (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method and independent of the seed source. In particular the abundance of mannose, arabinose, fucose, ricinoleic acid and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation.

59 BASIC BIOLOGICAL SCIENCES↗

Composition dependent effects in gas chromatography

Fundamantal concepts are developed which are required to optimize a gas chromatograph-mass spectrometer chemical analysis system suitable for use on an unmanned roving vehicle for Mars exploration. Prior efforts have developed simulation models for the chromatograph which were compared with data obtained from a test facility. Representation of binary systems by superposition was shown to be a first-order approximation and in certain cases large discrepencies were noted. This subtask has as its objective generation of additional binary data and analysis of the observed nonlinear effects.

Lavoie, R. C.↗

Characterization of Diesel Fuel by Chemical Separation Combined with Capillary Gas Chromatography (GC) Isotope Ratio Mass Spectrometry (IRMS)

The purpose of this study was to perform a preliminary investigation of compound-specific isotope analysis (CSIA) of diesel fuels to evaluate whether the technique could distinguish between the diesel samples from different sources/locations. The ability to differentiate or correlate diesel samples could be valuable for detecting fuel tax evasion schemes. Two fractionation techniques were used to isolate the n-alkanes from the fuel. Both δ13C and δD values for the n-alkanes were then determined by CSIA in each sample. Plots of δD versus δ13C with sample n-alkane points connected in order of increasing carbon number gave well separated clusters with characteristic shapes for each sample. Principal components analysis (PCA) with δ13C, δD, or combined δ13C and δD data on the yielded scores plots that could clearly differentiate the samples, thereby demonstrating the potential of this approach for fingerprinting fuel samples using the δ13C and δD values.

compound specific isotope ratio mass spectrometry↗

Signatures of Biologically Driven Hemicellulose Modification Quantified by Analytical Pyrolysis Coupled with Multidimensional Gas Chromatography Mass Spectrometry

Biomass storage operation is one major source of feedstock quality variability that impacts on downstream preprocessing, feeding, handling and conversion into biofuels, chemicals and products. In field Ccorn stover biomass bales undergoes degradation and cell wall components modification resulting from microbial biological heating occurring during storage. A molecular characterization of the modification was achieved to unveil and understand the changes of structural cell wall modification in corn stover samples by conducting low temperature (400°C) pyrolysis, comparing samples that were mildly biologicallyun heated to those that had been subjected to microbial severe biological heating (~60°C). Pyrolysis of the samples originating from biomass that had been heated during storage generated small oxygenates such as furfural, 5-methylfurfural and 2-(5H)-furanone with efficiencies that were as much as ten times greater than those measured for the mildly unheated samples. Most of the compounds having enhanced efficiencies were C5 oxygenates, suggesting that the pyrolysis products may be formed from hemicellulosic precursor polymers in the corn stover. The findings suggest that microbial heating may be disrupting the cell wall structure, fragmenting the hemicellulose or cellulose chains, generating more polymer termini that have higher efficiency for generating the oxygenates at lower temperatures. Pyrolysis variability with temperature may be a beneficial strategy for improved biomass cell wall characterization, and for guiding control strategies for enhanced control over product distributions , providing insights to understand and manage the feedstock variability as well as to inform harvest and storage best management practices.

09 BIOMASS FUELS↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

High-voltage spark atomic emission detector for gas chromatography

A dc-powered, double-gap, miniature nanosecond spark source for emission spectrochemical analysis of gas chromatographic effluents is described. The spark is formed between two thoriated tungsten electrodes by the discharge of a coaxial capacitor. The spark detector is coupled to the gas chromatograph by a heated transfer line. The gas chromatographic effluent is introduced into the heated spark chamber where atomization and excitation of the effluent occurs upon breakdown of the analytical gap. A microcomputer-controlled data acquisition system allows the implementation of time-resolution techniques to distinguish between the analyte emission and the background continuum produced by the spark discharge. Multiple sparks are computer averaged to improve the signal-to-noise ratio. The application of the spark detector for element-selective detection of metals and nonmetals is reported.

Calkin, C. L.↗

Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE): Lunar Advanced Volatile Analysis (LAVA) Capillary Fluid Dynamic Restriction Effects on Gas Chromatography

The Resource Prospector (RP) mission with the Regolith and Environment Science and Oxygen Lunar Volatile Extraction (RESOLVE) payload aims to show the presence of water in lunar regolith, and establish a proving ground for NASAs mission to Mars. One of the analysis is performed by the Lunar Advanced Volatiles Analysis (LAVA) subsystem, which consists of a fluid network that facilitates the transport of volatile samples to a gas chromatograph and mass spectrometer (GC-MS) instrument. The understanding of fluid dynamics directed from the GC to the MS is important due to the influence of flow rates and pressures that affect the accuracy of and prevent the damage to the overall GC-MS instrument. The micro-scale capillary fluid network within the GC alone has various lengths and inner-diameters; therefore, determination of pressure differentials and flow rates are difficult to model computationally, with additional complexity from the vacuum conditions in space and lack of a lunar atmosphere. A series of tests were performed on an experimental set-up of the system where the inner diameters of the GC transfer line connecting to the MS were varied. The effect on chromatography readings were also studied by applying these lines onto a GC instrument. It was found that a smaller inner diameter transfer line resulted in a lower flow rate, as well as a lower pressure differential across the thermal conductivity detector (TCD) unit of the GC and a negligible pressure drop across the mock-up capillary column. The chromatography was affected with longer retention times and broader peak integrations. It was concluded that a 0.050 mm inner diameter line still proved most suitable for the systems flow rate preferences. In addition, it was evident that this small transfer line portrayed some expense to GC signal characteristics and the wait time for steady-state operation.

RESOLVE↗

Analysis of benzo(a)pyrene in airborne particulates by gas chromatography

A routine method was developed to measure benzo(a)pyrene in airborne particulates. Samples were collected on a filter and the organic portion was extracted with cyclohexane. The polynuclear hydrocarbon (PNHC) fraction was separated from the aliphatics by column chromatography. An internal standard was added to the extract and a portion of it was injected into a gas chromatograph. Although the gas chromatographic method has often been reported in the literature, satisfactory separation of benzo(a)pyrene and benzo(e)pyrene has not been achieved. With the introduction of a nematic liquid crystal as the stationary phase good separation is now possible.

Luedecke, E.↗

Cyclopentadiene evolution during pyrolysis-gas chromatography of PMR polyimides

The effect of formulated molecular weight (FMW), extent of cure, and cumulative aging on the amount of cyclopentadiene (CPD) evolved from Polymerization of Monomeric Reactants (PMR) polyimides were investigated by pyrolysis-gas chromotography (PY-GC). The PMR polyimides are additional crosslinked resins formed from an aromatic diamine, a diester of an aromatic tetracarboxylic acid and a monoester of 5-norbornene-2, 3-dicarboxylic acid. The PY-GC results were related to the degree of crosslinking and to the thermo-oxidative stability (weight loss) of PMR polyimides. Thus, PY-GC has shown to be a valid technique for the characterization of PMR polyimide resins and composites via correlation of the CPD evolved versus the thermal history of the PMR sample.

Alston, William B.↗