Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of the 238U neutron-capture cross section and gamma-emission spectra from 10 eV to 100 keV using the DANCE detector at LANSCE

A careful new measurement of the {sup 238}U(n,{gamma}) cross section from 10 eV to 100 keV has been made using the DANCE detector at LANSCE. DANCE is a 4{pi} calorimetric scintillator array consisting of 160 BaF{sub 2} crystals. Measurements were made on a 48 mg/cm{sup 2} depleted uranium target. The cross sections are in general good agreement with previous measurements. The gamma-ray emission spectra, as a function of gamma multiplicity, were also measured and compared to model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of asymmetric concentration profile on thermal conductivity in Ge/SiGe superlattices

The effect of the chemical composition in Si/Ge-based superlattices on their thermal conductivity has been investigated using molecular dynamics simulations. Simulation cells of Ge/SiGe superlattices have been generated with different concentration profiles such that the Si concentration follows a step-like, a tooth-saw, a Gaussian, and a gamma-type function in direction of the heat flux. The step-like and tooth-saw profiles mimic ideally sharp interfaces, whereas Gaussian and gamma-type profiles are smooth functions imitating atomic diffusion at the interface as obtained experimentally. Symmetry effects have been investigated comparing the symmetric profiles of the step-like and the Gaussian function to the asymmetric profiles of the tooth-saw and the gamma-type function. At longer sample length and similar degree of interdiffusion, the thermal conductivity is found to be lower in asymmetric profiles. Furthermore, it is found that with smooth concentration profiles where atomic diffusion at the interface takes place the thermal conductivity is higher compared to systems with atomically sharp concentration profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inelastic partial {gamma}-ray cross sections of {sup 150}Sm+n reactions for E{sub n} = 1-15 MeV

The {sup 150}Sm(n,n'{gamma}) reaction was measured from E{sub n} = 1 to 15 MeV at the Los Alamos Neutron Science Cemter (LANSCE). The {gamma} rays were detected with the Compton-suppressed Germanium Array for Neutron Induced Excitations (GEANIE). Measured {gamma}-ray excitation functions were converted to partial {gamma}-ray cross sections, Twenty four individual {gamma}-rays up to E{sub x} = 1.8 MeV in {sup 150}Sm were measured. Results are compared with enhanced Hauser Feshbach model calculations: the spin distribution in the pre-equilibrium reaction is calculated with the quantum mechanical model of Feshbach, Kerman and Koonin. The particle transmission coefficients were calculated with two different global optical model potential parameter sets. We employed the coupled-channel optical model based on the soft rotor model and with spherical potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modelling the flux distribution function of the extragalactic gamma-ray background from dark matter annihilation

The one-point function (i.e., the isotropic flux distribution) is a complementary method to (anisotropic) two-point correlations in searches for a gamma-ray dark matter annihilation signature. Using analytical models of structure formation and dark matter halo properties, we compute the gamma-ray flux distribution due to annihilations in extragalactic dark matter halos, as it would be observed by the Fermi Large Area Telescope. Combining the central limit theorem and Monte Carlo sampling, we show that the flux distribution takes the form of a narrow Gaussian of 'diffuse' light, with an 'unresolved point source' power-law tail as a result of bright halos. We argue that this background due to dark matter constitutes an irreducible and significant background component for point-source annihilation searches with galaxy clusters and dwarf spheroidal galaxies, modifying the predicted signal-to-noise ratio. A study of astrophysical backgrounds to this signal reveals that the shape of the total gamma-ray flux distribution is very sensitive to the contribution of a dark matter component, allowing us to forecast promising one-point upper limits on the annihilation cross-section. We show that by using the flux distribution at only one energy bin, one can probe the canonical cross-section required for explaining the relic density, for dark matter of masses around tens of GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

AN EVOLVING STELLAR INITIAL MASS FUNCTION AND THE GAMMA-RAY BURST REDSHIFT DISTRIBUTION

Recent studies suggest that Swift gamma-ray bursts (GRBs) may not trace an ordinary star formation history (SFH). Here, we show that the GRB rate turns out to be consistent with the SFH with an evolving stellar initial mass function (IMF). We first show that the latest Swift sample of GRBs reveals an increasing evolution in the GRB rate relative to the ordinary star formation rate at high redshifts. We then assume only massive stars with masses greater than the critical value to produce GRBs and use an evolving stellar IMF suggested by Dave to fit the latest GRB redshift distribution. This evolving IMF would increase the relative number of massive stars, which could lead to more GRB explosions at high redshifts. We find that the evolving IMF can well reproduce the observed redshift distribution of Swift GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Detector Response Function and Directional Gamma-Ray Source Calculations for Polaris

A Directional Unfolded Source Term (DUST) method was developed to compute directionally resolved gamma-ray source terms based on back-projection spectra synthesized by Compton Cameras. Spectral features in the unprocessed spectra are indistinct primarily because the rotational angles for the conical projections cannot be determined, so probability distributions are constructed from overlapping cones. The DUST method uses an angular response function to compute a covariance matrix, which is used to process count rates in back-projection spectra by linear regression to partition the gamma-rays among several spatial regions. This method was applied to analyze data collected by the Polaris detector during an evaluation that was conducted at Oak Ridge National Laboratory (ORNL). The evaluation includes measurements of calibration sources with angular separations ranging from 1° to more than 50°. Measurements were also performed for cylindrical depleted uranium castings and a 137 Cs source inside a large polyethylene sphere. The DUST algorithm was able to differentiate gamma-rays emitted by 137 Cs and 60 Co when the sources were separated by less than 2°, but separation greater than 10° was required to isolate the 133 Ba emission from gamma-rays emitted by the other sources. The computed source terms were consistent with emission profiles from the calibration sources and from models of the spatially-extended sources. Methods for viewing radiation profiles were also evaluated because user input is required to select spatial regions of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of the low-lying structure of {sup 94}Zr with the (n,n{sup '}{gamma}) reaction

The low-lying structure of {sub 40}{sup 94}Zr was studied with the (n,n{sup '}{gamma}) reaction, and a level scheme was established based on excitation function and {gamma}{gamma} coincidence measurements. Branching ratios, multipole mixing ratios, and spin assignments were determined from angular distribution measurements. Lifetimes of levels up to 3.4 MeV were measured by the Doppler-shift attenuation method, and for many transitions the reduced transition probabilities were determined. In addition to the anomalous 2{sub 2}{sup +} state, which has a larger B(E2;2{sub 2}{sup +}{yields}0{sub 1}{sup +}) value than the B(E2;2{sub 1}{sup +}{yields}0{sub 1}{sup +}), the experimental results revealed interesting and unusual properties of the low-lying states in {sup 94}Zr. In a simple interpretation, the excited states are classified in two distinct categories, i.e., those populating the 2{sub 2}{sup +} state and those decaying to the 2{sub 1}{sup +} state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Industrialization of Hydrogen Getter for Nuclear Waste Transportation Application - 18189

The hydrogen risk generated by radiolysis of organic compounds during a nuclear waste transport is a major issue. The use of irreversible getters is considered to limit this risk. We previously worked on MnO{sub 2}/Ag{sub 2}O getter, in order to better understand the trapping phenomenon and to ensure its reliability. We demonstrated that chemisorption of hydrogen, which is required for its application, has been shown by using several characterization techniques. Proton insertion mechanism in MnO{sub 2} has been elucidated by pair distribution function analysis. Gamma irradiation up to 4 MGy has been performed on MnO{sub 2}/Ag{sub 2}O hydrogen getter and shown that chemical and crystallographic properties are not influenced under gamma irradiation. After those fundamentals studies, industrialization of MnO{sub 2}/Ag{sub 2}O getter preparation has been studied in order to have available getter materials for industrial applications with large amounts of MnO{sub 2}/Ag{sub 2}O powder. The preparation of hydrogen getter at laboratory scale consists of mixing commercial powders with various chemical treatments (grounding, moistening, sonication and drying). The industrialization strategy consists of preparing firstly on a laboratory scale and then increasing the getter preparation up to several kilograms. At each preparation step, hydrogen trapping experiments are performed to confirm the expected performance of getter materials. Several characterizations techniques have been performed (X-Ray Diffraction, Specific Surface Area...) to analyse the properties of the getter and have shown that no impact of upscale preparation is evidenced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intrinsic frame inverse mass tensor as a function of {beta} and {gamma} in the Bohr Hamiltonian

Analytical expressions are derived for the components of the intrinsic frame inverse mass tensor of the Bohr Hamiltonian. These expressions contain parameters which are determined by the experimental data on the B(E2)'s and the excitation energies of the low-lying collective states. It is shown that the nondiagonal component of the intrinsic frame mass tensor has a small effect on the collective motion. It is shown also that the values of the B{sub {beta}{beta}}, B{sub {gamma}{gamma}} and the rotational mass coefficientB{sub 1} differ in the well-deformed nuclei by factor 3 or more.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of neutron and gamma-ray cross-correlation functions with 4 He detectors

For the first time, the neutron and gamma-ray time-dependent cross-correlation distributions from spontaneous fission and (α, n) neutron sources are measured with the 4 He fast neutron detectors. The pulse shape discrimination technique based on charge comparison is utilized to discriminate between neutrons and gamma-rays in the identification of the four possible correlated pairs: (γ, γ), (n, n), (γ, n), and (n, n). Both total and individual cross-correlation functions are obtained, and their shapes can be easily distinguished among different neutron sources. The (n, n) and (γ, n) correlations are selectively analyzed and the peak position of the (n, n) and (γ, n) pairs shows a linear correlation with source-detector distance. Here, the measurements illustrate the feasibility of using 4 He detectors to identify nuclear materials and their geometrical configurations, as well as other applications in nuclear nonproliferation and safeguards. In particular, the (n, n) correlated data can be very clearly assayed even in the presence of significant gamma fields without the use of shielding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Maximum Likelihood Estimation: Some Basics

The maximum likelihood estimation is a general estimation procedure. It is often compared to estimation procedures like the ordinary least squares regression or generalized method of moments, to name a few. We discuss some basics about the maximum likelihood estimation, its advantages and disadvantages, and provide an example application to a gamma distribution function.

97 MATHEMATICS AND COMPUTING↗

Examination of the low-energy enhancement of the γ -ray strength function of Fe 56

A model-independent technique was used to determine the gamma-ray strength function (gamma SF) of Fe-56 down to gamma-ray energies less than 1 MeV for the first time with GRETINA using the (p, p') reaction at 16MeV. No difference was observed in the energy dependence of the gamma SF built on 2(+) and 4(+) final states, supporting the Brink hypothesis. In addition, angular distribution and polarization measurements were performed. The angular distributions are consistent with dipole radiation. The polarization results show a small bias towards magnetic character in the region of the enhancement.

Jones, M. D.↗

SU-E-QI-13: Predictable Models for Radio-Sensitizing Agent Kinetics: Application to Stereotactic Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The radiation dose enhancement depends on the time course of iodine in the tumors. A prolonged CT scanning (∼30 min) is required to follow-up iodine kinetics for recruited patients. This protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce the acquisition time. Methods: 12 patients received an intravenous bolus of iodinated contrast agent, followed by a steady-state infusion to ensure stable intra-tumoral amounts of iodine during the treatment. Absolute iodine concentrations (IC) were derived from 40 multi-slice dynamic conventional CT images of the brain. The impulse response function (IRF) to the bolus was estimated using the adiabatic approximation of the Johnson and Wilson's model. The arterial input function (AIF) of the steady-state infusion was fitted with several models: Gamma, Gamma with recirculation and hybrid. Estimated IC were calculated by convolving the IRF with the modeled AIF and were compared to the measured data. Results: The gamma variate function was not relevant to model the AIF due to high differences with the measured AIF. The hybrid and the gamma with recirculation models provided differences below 8% during the whole acquisition time. The absolute difference between the measured and the estimated IC was lower than 0.5 mg/ml, which corresponds to 5% of dose enhancement error. Conclusion: The proposed method allows a good estimation of the iodine time course with reduced scanning delays (3 instead of 30 min) and dose to the patient. The results suggest that the dose errors may stay within the radiotherapy standards.

60 APPLIED LIFE SCIENCES↗

Incorporation of New Convective Ice Microphysics into the NASA GISS GCM and Impacts on Cloud Ice Water Path (IWP) Simulation

The CMIP5 configurations of the GISS Model-E2 GCM simulated a mid- and high latitude ice IWP that decreased by 50 relative to that simulated for CMIP3 (Jiang et al. 2012; JGR). Tropical IWP increased by 15 in CMIP5. While the tropical IWP was still within the published upper-bounds of IWP uncertainty derived using NASA A-Train satellite observations, it was found that the upper troposphere (200 mb) ice water content (IWC) exceeded the published upper-bound by a factor of 2. This was largely driven by IWC in deep-convecting regions of the tropics.Recent advances in the model-E2 convective parameterization have been found to have a substantial impact on tropical IWC. These advances include the development of both a cold pool parameterization (Del Genio et al. 2015) and new convective ice parameterization. In this presentation, we focus on the new parameterization of convective cloud ice that was developed using data from the NASA TC4 Mission. Ice particle terminal velocity formulations now include information from a number of NASA field campaigns. The new parameterization predicts both an ice water mass weighted-average particle diameter and a particle cross sectional area weighted-average size diameter as a function of temperature and ice water content. By assuming a gamma-distribution functional form for the particle size distribution, these two diameter estimates are all that are needed to explicitly predict the distribution of ice particles as a function of particle diameter.GCM simulations with the improved convective parameterization yield a 50 decrease in upper tropospheric IWC, bringing the tropical and global mean IWP climatologies into even closer agreement with the A-Train satellite observation best estimates.

tropical regions↗

Maximum Likelihood Estimation: Some Basics

The maximum likelihood estimation is a general estimation procedure. It is often compared to estimation procedures like the ordinary least squares regression or generalized method of moments, to name a few. We discuss some basics about the maximum likelihood estimation, its advantages and disadvantages, and provide an example application to a gamma distribution function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parity-violating inelastic electron-proton scattering at low Q 2 above the resonance region

We report the measurement of the parity-violating asymmetry for the inelastic scattering of electrons from the proton, at $Q^2 = 0.082$ GeV$^2$ and $ W = 2.23$ GeV, above the resonance region. The result $A_{\rm Inel} = - 13.5 \pm 2.0 ({\rm stat}) \pm 3.9 ({\rm syst})$ ppm agrees with theoretical calculations, and helps to validate the modeling of the $\gamma Z$ interference structure functions $F_1^{\gamma Z}$ and $F_2^{\gamma Z}$ used in those calculations, which are also used for determination of the two-boson exchange box diagram ($\Box_{\gamma Z}$) contribution to parity-violating elastic scattering measurements. A positive parity-violating asymmetry for inclusive $\pi^-$ production was observed, as well as positive beam-normal single-spin asymmetry for scattered electrons and a negative beam-normal single-spin asymmetry for inclusive $\pi^-$ production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Functional Bounding Content Envelope for Gamma and Neutron Emitting Isotopes in the Model 9977 Packaging

The contents approved for shipment in a Type B radioactive material transportation package have historically been descriptions of discrete items, or groupings of well-defined similar items, in the package safety basis documentation. The need for a comprehensive functional content envelope of both gamma and neutron emitting nuclides compliant with regulatory limits has become necessary as the DOE complex requires shipments of unique mixtures of radionuclides and impurities. Recent publications have presented a calculational model and a corresponding content envelope intended to be compliant with federal regulatory external radiation limits as well as design decay heat limits based on the Model 9977 Packaging. The methodology used to develop this content envelope consisted of determining the external radiation dose rates based on one gram of a given isotope combined, in the case of actinides, with various levels of light element impurities and determining the allowable mass to the regulatory limits based on these dose rates. The method of ratioing from these calculations to the masses that meet the regulatory limits fails in the case of some combinations of actinides and light element impurities because of the effect of subcritical multiplication, resulting in non-conservative and non-compliant dose rates in some cases. This is particularly true for many actinides combined with beryllium, boron, fluorine, lithium, and sodium. In this study, the source was modeled as a sphere with the appropriate dimensions based on the actinide or gamma source density and placed at the bottom of the containment vessel for maximum conservatism. The results presented in this report rectify the above-noted deficiencies by adjusting the previously determined mass limits so that the resulting dose rates are compliant with regulatory limits. Some amount of iteration was required in some instances to adjust the masses for dose compliance. In some instances the masses were increased since they were too conservative. In addition, the method of ratioing the masses when applied to several gamma emitting isotopes also resulted in either non-conservative or overly conservative data. The mass imits presented here are for bare sources and are complaint with the design decay heat limit of 19W. The masses are based on package surface dose rates (the limiting dose rate) that fall in the range 185-195 mrem/h, thus giving an additional margin of between 7.5% and 2.5% to the regulatory limit of 200 mrem/h. This report presents a revised set of mass limits (i.e., content envelope) for several neutron emitting actinides with varying levels of light element impurities compliant with both external radiation and design decay heat limits. In addition, revised limits for gamma sources are also presented. The neutron emitter mass limits are in Tables 1 through 9 and the gamma emitter mass limits are in Table 10. The revised content envelope covering a wide range of materials present in the DOE complex, was developed for the Model 9977 Packaging, providing conservative limits for other commonly-used Type B Packagings such as the Models 9975 and 9978. It should be noted that for the Model 9977 package, shipment is also possible with three shielded containers – lead or tungsten for gamma sources and polyethylene for neutron emitters. The design decay heat limits for these are as follows: 19W for tungsten, 6W for lead and 3W for polyethylene. The limits presented in this report would need to be checked against the lower decay heat limits for the lead and polyethylene and adjusted as required for compliance. Criticality safety is not factored into these limits and should be evaluated on a case by case basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗