Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Response to graded Lower Body Negative Pressure (LBNP) after space flight

The effects of space flight on orthostatic function were studied. LBNP tests (0 to -60 mmHg) were administered to 7 crew members preflight and 2 to 6 hrs after 6 to 9 day shuttle missions. Cardiac stroke volumes were obtained each minute by echo Doppler. Orthostatic responses are given. The data suggest a decline in postflight orthostatic function, as assessed by LBNP, due to reduced cardiac filling despite potentiated heart rate and vasoconstrictor reflex responses in most crew members.

Fortney, S.↗

Differential baroreflex control of heart rate in sedentary and aerobically fit individuals

PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.

NASA Discipline Cardiopulmonary↗

MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

Bautz, Mark↗

Drifting Recovery Base Concept for GEO Derelict Object Capture

Over 250 objects hover within 6 m/sec of perfect geostationary orbit. Over half of these objects lie within 0.1 m/sec of the GEO velocity. Such items have 62% of the total velocity required to achieve Earth gravitational escape. A conceptual architecture is proposed to clean this orbit area of derelict objects while providing a demonstration mission for many facets of future asteroid mining operations. These near-GEO objects average nearly 2000kg each, consisting of (typically functioning) power systems, batteries, and large quantities of components and raw aerospace-grade refined materials. Such a demonstration collection system could capture, collect and remove all GEO derelict objects in an international effort to create a depot of components and of aerospace-grade raw materials--with a total mass greater than that of the International Space Station--as a space scrap depot ready for transfer to lunar or Mars orbit, using only two heavy-lift launches and 2-3 years of on-orbit operations.

Bacon, John B.↗

Cationic influences upon synaptic transmission at the hair cell-afferent fiber synapse of the frog

The concentrations of inorganic cations (K+, Na+, and Ca2+) bathing the isolated frog labyrinth were varied in order to assess their role in influencing and mediating synaptic transmission at the hair cell-afferent fiber synapse. Experiments employed intracellular recordings of synaptic activity from VIIIth nerve afferents. Recordings were digitized continuously at 50 kHz, and excitatory postsynaptic potentials were detected and parameters quantified by computer algorithms. Particular attention was focused on cationic effects upon excitatory postsynaptic potential frequency of occurrence and excitatory postsynaptic potential amplitude, in order to discriminate between pre- and postsynaptic actions. Because the small size of afferents preclude long term stable recordings, alterations in cationic concentrations were applied transiently and their peak effects on synaptic activity were assessed. Increases in extracellular K+ concentration of a few millimolar produced a large increase in the frequency of occurrence of excitatory postsynaptic potentials with little change in amplitude, indicating that release of transmitter from the hair cell is tightly coupled to its membrane potential. Increasing extracellular Na+ concentration resulted in an increase in excitatory postsynaptic potential amplitude with no significant change in excitatory postsynaptic potential frequency of occurrence, suggesting that the transmitter-gated subsynaptic channel conducts Na+ ions. Decreases in extracellular Ca2+ concentration had little effect upon excitatory postsynaptic potential frequency, but increased excitatory postsynaptic potential frequency and amplitude. These findings suggest that at higher concentrations Ca2+ act presynaptically to prevent transmitter release and postsynaptically to prevent Na+ influx during the generation of the excitatory postsynaptic potential. The influences of these ions on synaptic activity at this synapse are remarkably similar to those reported at the vertebrate neuromuscular junction. The major differences between these two synapses are the neurotransmitters and the higher resting release rate and higher sensitivity of release to increased K+ concentrations of the hair cells over that of motor nerve terminals. These differences reflect the functional roles of the two synapses: the motor nerve terminal response in an all-or-nothing signal consequent from action potential invasion, while the hair cell releases transmitter in a graded fashion, proportionate to the extent of stereocilial deflection. Despite these differences between the two junctions, the similar actions of these elemental cations upon synaptic function at each implies that these ions may participate similarly in the operations of other synapses, independent of the neurotransmitter type.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

The frequency dependence of the viscous component of the magnetic susceptibility of lunar rock and soil samples

The susceptibility of two lunar samples (a soil and a low metamorphic grade breccia) has been measured in a weak field - 0.001 Oe - and as a function of frequency from 0.032 to 1.0 Hz. The measurements were made using a superconducting magnetometer. The results show that the susceptibility decreases linearly with the log of frequency. This observation is in agreement with a theoretical model for viscous decay based on the Neel theory of single-domain and superparamagnetic grains. The relation derived agrees with a model in which there is a uniform distribution of relaxation times.

Hanneken, J. W.↗

Altitude Operational Characteristics of Prototype J40-WE-8 Turbojet Engine

The altitude operational characteristics of the prototype J40-WE-8 turbojet engine were determined in the NACA Lewis altitude wind tunnel. The operational characteristics that were obtained include (1) compressor surge characteristics, (2) acceleration and deceleration rates, (3) steady-state windmilling-engine characteristics, (4) altitude ignition characteristics, and (5) the effect of two grades of fuel on steady-state engine performance at an altitude of 45,000 feet and a flight Mach number of 0.20. The altitude ignition characteristics determined include the effects of (1) ignition fuel flow, (2) two ignition procedures, (3) fuel temperatures, and (4) two grades of fuel on ignition characteristics. The compressor surge line, when presented as a function of compressor pressure ratio and corrected engine speed, was not affected by changes in flight condition and was independent of engine-inlet installation and of the manner in which surge was approached, rapidly or slowly. Also there was no effect of altitude or engine-inlet installation on the compressor surge recovery line when presented as a function of compressor pressure ratio and corrected engine speed.

FUELS - RELATION TO ENGINE PERFORMANCE↗

A Versatile Lifting Device for Lunar Surface Payload Handling, Inspection and Regolith Transport Operations

Devices for lifting and transporting payloads and material are critical for efficient Earth-based construction operations. Devices with similar functionality will be needed to support lunar-outpost construction, servicing, inspection, regolith excavation, grading and payload placement. Past studies have proposed that only a few carefully selected devices are required for a lunar outpost. One particular set of operations involves lifting and manipulating payloads in the 100 kg to 3,000 kg range, which are too large or massive to be handled by unassisted astronauts. This paper will review historical devices used for payload handling in space and on earth to derive a set of desirable features for a device that can be used on planetary surfaces. Next, an innovative concept for a lifting device is introduced, which includes many of the desirable features. The versatility of the device is discussed, including its application to lander unloading, servicing, inspection, regolith excavation and site preparation. Approximate rules, which can be used to size the device for specific payload mass and reach requirements, are provided. Finally, details of a test-bed implementation of the innovative concept, which will be used to validate the structural design and develop operational procedures, is provided.

Doggett, William R.↗

Evaluation of Fast Switching Diode 1N4448 Over a Wide Temperature Range

Electronic parts used in the design of power systems geared for space applications are often exposed to extreme temperatures and thermal cycling. Limited data exist on the performance and reliability of commercial-off-the-shelf (COTS) electronic parts at temperatures beyond the manufacturers specified operating temperature range. This report summarizes preliminary results obtained on the evaluation of automotive-grade, fast switching diodes over a wide temperature range and thermal cycling. The investigations were carried out to establish a baseline on functionality of these diodes and to determine suitability for use outside their recommended temperature limits.

Thermal Cycling↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick was extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: maximum heat pipe performance as a function of fluid inventory, maximum performance as a function of operating temperature, maximum performance as a function of evaporator elevation, and influence of slab wick orientation on performance. The experimental data were compared with theoretical predictions obtained with the GRADE computer program.

Groll, M.↗

Extreme Temperature Performance of Automotive-Grade Small Signal Bipolar Junction Transistors

Electronics designed for space exploration missions must display efficient and reliable operation under extreme temperature conditions. For example, lunar outposts, Mars rovers and landers, James Webb Space Telescope, Europa orbiter, and deep space probes represent examples of missions where extreme temperatures and thermal cycling are encountered. Switching transistors, small signal as well as power level devices, are widely used in electronic controllers, data instrumentation, and power management and distribution systems. Little is known, however, about their performance in extreme temperature environments beyond their specified operating range; in particular under cryogenic conditions. This report summarizes preliminary results obtained on the evaluation of commercial-off-the-shelf (COTS) automotive-grade NPN small signal transistors over a wide temperature range and thermal cycling. The investigations were carried out to establish a baseline on functionality of these transistors and to determine suitability for use outside their recommended temperature limits.

Thermal Cycling↗

Characterization of graded interface In(x)Ga(1-x)As/In(0.52)Al(0.48)As (x between 0.53 and 0.70) structures grown by molecular-beam epitaxy

Modulation-doped In(x)Ga(1-x)As/In(0.52)Al(0.48)As/InP structures were grown by molecular-beam epitaxy with x values between 53 and 70 percent. For pseudomorphic cases, graded instead of abrupt interfaces were used. Hall mobility and persistent photoconductivity measurements as a function of temperature were used to characterize samples with different structural parameters. Consistent trends in the variation of mobilities and two-dimensional carrier concentration, n(2D), under light and dark conditions have been observed and discussed in terms of applicable scattering mechanisms. The Hall mobilities are comparable to the best results obtained to date but with significantly higher n(2D) concentration.

Peng, C. K.↗

Aspects of Synthetic Vision Display Systems and the Best Practices of the NASA's SVS Project

NASA s Synthetic Vision Systems (SVS) Project conducted research aimed at eliminating visibility-induced errors and low visibility conditions as causal factors in civil aircraft accidents while enabling the operational benefits of clear day flight operations regardless of actual outside visibility. SVS takes advantage of many enabling technologies to achieve this capability including, for example, the Global Positioning System (GPS), data links, radar, imaging sensors, geospatial databases, advanced display media and three dimensional video graphics processors. Integration of these technologies to achieve the SVS concept provides pilots with high-integrity information that improves situational awareness with respect to terrain, obstacles, traffic, and flight path. This paper attempts to emphasize the system aspects of SVS - true systems, rather than just terrain on a flight display - and to document from an historical viewpoint many of the best practices that evolved during the SVS Project from the perspective of some of the NASA researchers most heavily involved in its execution. The Integrated SVS Concepts are envisagements of what production-grade Synthetic Vision systems might, or perhaps should, be in order to provide the desired functional capabilities that eliminate low visibility as a causal factor to accidents and enable clear-day operational benefits regardless of visibility conditions.

Bailey, Randall E.↗

Burning of CP Titanium (Grade 2) in Oxygen-Enriched Atmospheres

The flammability in oxygen-enriched atmospheres of commercially pure (CP) titanium rods as a function of diameter and test gas pressure was determined. Test samples of varying diameters were ignited at the bottom and burned upward in 70% O2/balance N2 and in 99.5+% O2 at various pressures. The burning rate of each ignited sample was determined by observing the apparent regression rate of the melting interface (RRMI) of the burning samples. The burning rate or RRMI increased with decreasing test sample diameter and with increasing test gas pressure and oxygen concentration

Stoltzfus, Joel M.↗

Functional and anatomical characteristics of the nerve-brown adipose interaction in the rat

Experiments were conducted on 12 male rats to study the coupling of signals from the sympathetic nervous system to the brown adipose tissue. Analysis of electron photomicrographs revealed considerable morphological heterogeneity among the nerves entering and leaving the interscapular fat pad. In response to electrical simulation of the nerves, the temperature of the brown fat increased following a rapid but transient temperature drop. Such changes were observed only on the ipsilateral side, indicating that the innervation to the interscapular brown fat of the rat is functionally bilateral rather than diffuse. The finding that brown fat is capable of responding in a graded fashion correlates well with observations suggesting that clusters of brown adipocytes may be electrically coupled.

Flaim, K. E.↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

Groll, M.↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Optimization of Coherent Lidar Performance Using Graded- Reflectance Transmitter Resonator Optics in the Low Equivalent Fresnel Number Region

Using a diffractive eigenmode treatment to model the laser output, we show that graded-reflectance resonator optics offer significant efficiency benefits over conventional hard-edge coupled unstable resonators in the context of coherent detection lidar applications. Extending previous work pertinent to the high equivalent Fresnel number regime, we have modelled the optimum performance of a notional super-Gaussian coupled cavity as a function of the key resonator parameters in the low equivalent Fresnel number regime.

lidar graded-reflectance transmitter resonator↗