Automotive fuel cell stack and system efficiency and fuel consumption based on vehicle testing on a chassis dynamometer at minus 18 °C to positive 35 °C temperatures

In this work we present an in-depth laboratory technology assessment of a 2016 Toyota Mirai Fuel Cell (FC) vehicle based on chassis dynamometer testing. The 114.6 kW FC stack has a high dynamic response, which makes this powertrain a FC-dominant hybrid electric vehicle. The measured peak efficiency is 66.0% FC stack and 63.7% FC system with an idle hydrogen flow rate of 4.39 g/hr. The high FC system efficiencies at low loads match typical vehicle power spectrums, resulting in a high average vehicle efficiency of 62% compared to 45% and 23% for a hybrid electric vehicle and a conventional vehicle, respectively. An energy breakdown accounts for the FC stack losses, FC system losses, air compressor loads, and heater loads for different drive cycles and different thermal conditions. The cold-start North American city drive cycle (UDDS) energy consumption values are, respectively, 758, 581, 226, and 321 Wh/km at ambient conditions of -18 degrees C, -7 degrees C, -25 degrees C and 35 degrees C with 850 W/m 2 of solar loading. The FC system shutdown and startup processes at temperatures below the freezing point contribute to the increased hydrogen consumption. Additionally, the raw test data files are available for download, thus providing the research community with a public reference data on a modern production automotive FC system.

08 HYDROGEN↗

Atomically dispersed Pt and Fe sites and Pt–Fe nanoparticles for durable proton exchange membrane fuel cells

Proton exchange membrane fuel cells convert hydrogen and oxygen into electricity without emissions. The high cost and low durability of Pt-based electrocatalysts for the oxygen reduction reaction hinder their wide application, and the development of non-precious metal electrocatalysts is limited by their low performance. Here we design a hybrid electrocatalyst that consists of atomically dispersed Pt and Fe single atoms and Pt–Fe alloy nanoparticles. Its Pt mass activity is 3.7 times higher than that of commercial Pt/C in a fuel cell. More importantly, the fuel cell with a low Pt loading in the cathode (0.015 mg Pt cm –2 ) shows an excellent durability, with a 97% activity retention after 100,000 cycles and no noticeable current drop at 0.6 V for over 200 hours. These results highlight the importance of the synergistic effects among active sites in hybrid electrocatalysts and provide an alternative way to design more active and durable low-Pt electrocatalysts for electrochemical devices.

25 ENERGY STORAGE↗

Hydrogen generation using a fuel cell system with an REP

A fuel cell system includes a fuel cell having an anode and a cathode configured to output cathode exhaust. The fuel cell is configured to generate waste heat. The fuel cell system further includes a reformer configured to partially reform a feed gas using the waste heat and output a hydrogen-containing stream. The fuel cell system further includes a reformer-electrolyzer-purifier (“REP”) having an REP anode configured to receive a first portion of the hydrogen-containing stream and an REP cathode.

Jahnke, Fred C.↗

Direct Methanol Fuel Cell for Portable Applications

A five cell direct methanol fuel cell stack has been developed at the Jet Propulsion Laboratory. Presently direct methanol fuel cell technology is being incorporated into a system for portable applications. Electrochemical performance and its dependence on flow rate and temperature for the five fuel cell are presented.

fuel↗

Maritime Fuel Cell Generator Project [FY2018]

Fuel costs and emissions in maritime ports are an opportunity for transportation energy efficiency improvement and emissions reduction efforts. Ocean-going vessels, harbor craft, and cargo handling equipment are still major contributors to air pollution in and around ports. Diesel engine costs continually increase as tighter criteria pollutant regulations come into effect and will continue to do so with expected introduction of carbon emission regulations. Diesel fuel costs will also continue to rise as requirements for cleaner fuels are imposed. Both aspects will increase the cost of diesel-based power generation on the vessel and on shore. Although fuel cells have been used in many successful applications, they have not been technically or commercially validated in the port environment. One opportunity to do so was identified in Honolulu Harbor at the Young Brothers Ltd. wharf. At this facility, barges sail regularly to and from neighboring islands and containerized diesel generators provide power for the reefers while on the dock and on the barge during transport, nearly always at part load. Due to inherent efficiency characteristics of fuel cells and diesel generators, switching to a hydrogen fuel cell power generator was found to have potential emissions and cost savings. Deployment in Hawaii showed the unit needed greater reliability in the start-up sequence, as well as an improved interface to the end-user, thereby presenting opportunities for repairing/upgrading the unit for deployment in another locale. In FY2018, the unit was repaired and upgraded based on the Hawaii experience, and another deployment site was identified for another 6-month deployment of the 100 kW MarFC.

08 HYDROGEN↗

Space Shuttle Upgrades: Long Life Alkaline Fuel Cell

NASA has utilized the alkaline fuel cell technology to provide electrical power for manned launch vehicles such as Gemini, Apollo, and the Space Shuttle. The current Shuttle alkaline fuel cells are procured from UTC Fuel Cells, a United Technologies Company. The alkaline fuel cells are very reliable but the operating life is limited to 2600 hours due to voltage degradation of the individual cells. The main limiting factor in the life of the cells is corrosion of the cell's fiberglass/epoxy frame by the aqueous potassium hydroxide electrolyte. To reduce operating costs, the orbiter program office approved the Long Life Alkaline Fuel Cell (LLAFC) program as a shuttle upgrade in 1999 to increase the operating life of the fuel cell powerplant to 5000 hours. The LLAFC program incorporates improving the cell by extending the length of the corrosion path, which reduces the cell frame corrosion. UTCFC performed analysis to understand the fundamental mechanisms that drive the cell frame corrosion. The analysis indicated that the corrosion path started along the bond line between the cathode and the cell frame. Analysis also showed that the oxygen available at the cathode, the catalyst on the electrode, and the electrode substrate all supported or intensified the corrosion. The new cell design essentially doubled the corrosion path to mitigate the problem. A 10-cell stack was tested for 5000 hours during the development phase of this program to verify improved cell performance. A complete 96-cell stack was then tested for 5000 hours during the full manned-space qualification phase of this program. Additional upgrades to the powerplant under this program are: replacing the aluminum body in the pressure regulator with stainless steel to reduce corrosion, improving stack insulator plate with improved resistance to stress failure and improved temperature capability, and replacing separator plate elastomer seals with a more durable material and improved seal retention.

Kerri McCurdy↗

Development of a fuel cell for the EMU

The fuel cell technology for the advanced portable life support system is reviewed, using the breadboard test data, and the design concepts are presented for the development of the improved preprototype fuel cell. Subscale test results confirm the suitability of the solid polymer electrolyte fuel cell fueled by hydride stored hydrogen and oxygen for extravehicular mobility unit (EMU) power generation. Issues verified include passive, zero-G product water removal, nonventing operation in the EMU duty cycle, and complete recovery of product water in potable form. The long cycle life and quick rechargeability are confirmed in 600 h of testing including 150 deep discharge cycles.

Beckstrom, Paula↗

Self-regulating control of parasitic loads in a fuel cell power system

A fuel cell power system comprises an internal or self-regulating control of a system or device requiring a parasitic load. The internal or self-regulating control utilizes certain components and an interconnection scheme to produce a desirable, variable voltage potential (i.e., power) to a system or device requiring parasitic load in response to varying operating conditions or requirements of an external load that is connected to a primary fuel cell stack of the system. Other embodiments comprise a method of designing such a self-regulated control scheme and a method of operating such a fuel cell power system.

Vasquez, Arturo↗

In Situ Nanoscale Dynamics Imaging in a Proton‐Conducting Solid Oxide for Protonic Ceramic Fuel Cells

Abstract Hydrogen fuel cells and electrolyzers operating below 600 °C, ideally below 400 °C, are essential components in the clean energy transition. Yttrium‐doped barium zirconate BaZr 0.8 Y 0.2 O 3‐d (BZY) has attracted a lot of attention as a proton‐conducting solid oxide for electrochemical devices due to its high chemical stability and proton conductivity in the desired temperature range. Grain interfaces and topological defects modulate bulk proton conductivity and hydration, especially at low temperatures. Therefore, understanding the nanoscale crystal structure dynamics in situ is crucial to achieving high proton transport, material stability, and extending the operating range of proton‐conducting solid oxides. Here, Bragg coherent X‐ray diffractive imaging is applied to investigate in situ and in 3D nanoscale dynamics in BZY during hydration over 40 h at 200 °C, in the low‐temperature range. An unexpected activity of topological defects and subsequent cracking is found on a nanoscale covered by the macroscale stability. The rearrangements in structure correlate with emergent regions of different lattice constants, suggesting heterogeneous hydration. The results highlight the extent and impact of nanoscale processes in proton‐conducting solid oxides, informing future development of low‐temperature protonic ceramic electrochemical cells.

25 ENERGY STORAGE↗

Editors’ Choice—Diffusion Media for Cation Contaminant Transport Suppression into Fuel Cell Electrodes

Polymer electrolyte membrane fuel cells provide an alternative option to fossil fuel-based energy conversion devices. However, the corrosion of fuel cell components, specifically the bipolar plates, introduces contaminants (e.g., Fe, Ni) into the membrane electrode assembly (MEA). These contaminants accelerate the ionomer degradation by acting as a Fenton’s reagent, decreasing the fuel cell’s durability. This study presents the mechanism and the diffusion media properties affecting the transport of cation contaminants into the MEA. Cation contaminant transport was studied after altering the gas diffusion layers (GDLs) wettability, emulating the GDL properties after prolonged operation, by ex situ hydrogen peroxide treatment or in situ electrochemical potential cycling. A GDL with crack-free microporous layer (MPL) showed a lower cation transport rate to the catalyst layer than MPL with cracks after both ex situ and in situ treatment. A novel GDL was developed from modification of the conventional GDL via the addition of a hydrophobic layer to the GDL substrate, which suppressed the contaminant cation transport significantly. This novel GDL also showed improved fuel cell performance.

25 ENERGY STORAGE↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Analysis of a 100-W Regenerative Fuel Cell Demonstration

A 100-W regenerative fuel cell (RFC) demonstration was successfully completed at the NASA Glenn Research Center on December 11, 2014. This effort was funded by Advanced Space Power Systems milestone and represented the first demonstration of passive laboratory-scale stacks arranged as an RFC, consisting of a non-flow-through fuel cell and a static-feed electrolyzer. Once developed, these stacks present the potential to minimize system mass, volume, and parasitic power in comparison to existing terrestrial electrochemical systems and nonnuclear power generation options. Testing involved the fuel cell powering a simulated load then recycling fuel cell product water by subsequently electrolyzing it to regenerate hydrogen and oxygen gases for fuel cell operations. A total of five cycles were completed over a 2-week period, yielding cell voltage data for stack performance and quality measures for regenerated reactants. Overall, round-trip efficiency was calculated to be 47.4 percent. Gas crossover was observed in electrolyzer gas products, as residual gas analysis showed 1.1 percent hydrogen in oxygen and 0.4 percent oxygen in hydrogen. Fuel cell product water was determined to be more acidic and conductive and have a higher fluoride content when compared to deionized water.

fuel cell↗

Multi-functional anodes boost the transient power and durability of proton exchange membrane fuel cells

Abstract Proton exchange membrane fuel cells have been regarded as the most promising candidate for fuel cell vehicles and tools. Their broader adaption, however, has been impeded by cost and lifetime. By integrating a thin layer of tungsten oxide within the anode, which serves as a rapid-response hydrogen reservoir, oxygen scavenger, sensor for power demand, and regulator for hydrogen-disassociation reaction, we herein report proton exchange membrane fuel cells with significantly enhanced power performance for transient operation and low humidified conditions, as well as improved durability against adverse operating conditions. Meanwhile, the enhanced power performance minimizes the use of auxiliary energy-storage systems and reduces costs. Scale fabrication of such devices can be readily achieved based on the current fabrication techniques with negligible extra expense. This work provides proton exchange membrane fuel cells with enhanced power performance, improved durability, prolonged lifetime, and reduced cost for automotive and other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Polymer Electrolytes with High Ionic Concentration for Fuel Cells and Electrolyzers

As fuel cells and electrolyzers require higher performance and durability, the design aspects of polymer electrolytes continue to evolve. One distinctive trend in achieving a remarkably improved performance of electrochemical devices is to equip polymer electrolytes with high ionic concentration. This Review presents recent implementations of polymer electrolytes with a high ionic concentration in electrochemical devices. The synthetic approaches, benefits in device performance, challenges, and prospects of polymer electrolytes are summarized. The goal of this article is to explain the working principles of polymer electrolytes with a high acid concentration in high-performing fuel cells and electrolyzers, to survey recent achievements, and to address remaining technical issues. As well as informing polymer scientists, this Review may generate interest in the broader community of emerging fields to make use of these promising materials in tackling tough scientific challenges.

30 DIRECT ENERGY CONVERSION↗

Solid Polymer Electrolyte (SPE) fuel cell technology program

Many previously demonstrated improved fuel cell features were consolidated to (1) obtain a better understanding of the observed characteristics of the operating laboratory-sized cells; (2) evaluate appropriate improved fuel cell features in 0.7 sq ft cell hardware; and (3) study the resultant fuel cell capability and determine its impact on various potential fuel cell space missions. The observed performance characteristics of the fuel cell at high temperatures and high current densities were matched with a theoretical model based on the change in Gibbs free energy voltage with respect to temperature and internal resistance change with current density. Excellent agreement between the observed and model performance was obtained. The observed performance decay with operational time on cells with very low noble metal loadings (0.05 mg/sq cm) were shown to be related to loss in surface area. Cells with the baseline amount of noble catalyst electrode loading demonstrated over 40,000 hours of stable performance.

Source record↗