Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

Opportunities to Enable Electrolytic H2 Projects for Ammonia in the United States

Integration of large-scale electrolysis with the grid provides value to hydrogen and ammonia markets as well as the electricity system. Electrolysis has the potential to provide an alternative source of low-cost hydrogen by utilizing low-price electricity that may have limited availability, resulting in possible economic benefits for ammonia production. The use of that low-price electricity can simultaneously benefit the grid by reducing the price suppression that may occur with increased penetration of variable renewable generation. In addition, the rapid-response characteristics of electrolyzers enables them to provide ancillary services to the grid, such as operating reserves and frequency control. However, electrolyzer capital cost reductions, favorable electricity pricing structures, or other technology or market advancements are likely needed to achieve hydrogen prices competitive with incumbent production technologies. We discuss near-term, niche prospects where low-cost electrolytic hydrogen and ammonia could be produced, possible applications for those products, and further opportunities and drivers that might enable them.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become "standard" components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

43 PARTICLE ACCELERATORS↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-frequency based cyber security defense of wide-area control system for fast frequency reserve

Global power systems are transiting from conventional fossil fuel energy to renewable energies due to their environmental benefits. The increasing penetration of renewable energies presents challenges for power system operation. The efficiency and sufficiency of responsive reserves have become increasingly important for power systems with a high proportion of renewable energies. The Fast Frequency Reserve (FFR), especially the Wide-area Monitoring System (WAMS)-based FFR, is a promising and effective solution to secure and enhance the stability of power systems. However, cyber security has become a new challenge for the WAMS-based FFR system. Cyber attacks on the FFR control system may threaten the safety of power system operation due to the rapid power controllability requirement of FFR. Therefore, to address this problem, a time-frequency based cyber security defense framework is proposed to detect the cyber spoofing of synchrophasor data in WAMS-based FFR control systems. This paper first introduces the Continuous Wavelet Transforms (CWTs) to decompose spoofing signals. Then, the Dual-frequency Scale Convolutional Neural Networks (DSCNN) is proposed to identify the time-frequency domains matrix from two frequency scales. Integrating CWTs and DSCNN, an identification framework called CWTs-DSCNN is further proposed to detect the spoofing attacks in the WAMS-based FFR system. Multiple experiments using the actual data from FNET/GridEye are performed to verify the effectiveness of the framework in securing WAMS-based FFR systems.

25 ENERGY STORAGE↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Controlling the status of frequency-managed electric devices

Apparatus comprise control circuitry configured to control a line frequency of a microgrid by directing a first set of one or more electrical devices coupled to the microgrid to produce a change in the line frequency through a change in operation of the first set, such that a second set of one or more electrical devices coupled to the microgrid adjusts operation in response to a detected line frequency changeably produced by the first set. Related methods and additional apparatus and methods are disclosed. Apparatus and methods are disclosed that use line frequency and/or line voltage. Apparatus and methods are also disclosed that use control history.

Hammerstrom, Donald J.↗

Extracting maximal frequency response potential in controllable loads

Methods and apparatus are disclosed for extracting maximal frequency response potential in controllable loads. In one example, a method includes assigning a fitness metric to at least one electrical device coupled to a power grid, assigning a frequency threshold based on the fitness metric, and transmitting the assigned frequency threshold to the at least one electrical device. The fitness metric can be based at least in part on an availability component and a quality component associated with the at least one device and the frequency threshold can cause the at least one electrical device to activate autonomously based on a frequency of the power grid.

Lian, Jianming↗

Controls on the frequency content of near-source infrasound at open-vent volcanoes: a case study from Volcán Villarrica, Chile

Infrasound signals from open-vent volcanoes can contain information related to that volcano’s eruption dynamics and future activity. Studying a specific volcano’s acoustic signature during periods of relative quiescence is thus important for understanding potential warning signs of impending eruptions. Volcán Villarrica, located in southern Chile, has a long-lived active lava lake that produces continuous infrasound with spectral peaks centered around 1 Hz that vary by + / - ~ 0.2 Hz over day-to-week-long time scales. The infrasound frequency content has been shown to illuminate key volcanic properties such as eruption style and crater shape. Leading up to Villarrica’s most recent paroxysm in 2015, for instance, infrasound spectral changes coincided with a rise in Villarrica’s lava lake level. Quantifying and understanding the regular fluctuation in recorded infrasonic frequencies from Villarrica and other open-vent volcanoes is thus imperative during periods of relative calm. Our experiment entailed a week-long period of crater rim infrasound observations associated with stable, open-vent activity and revealed two independent source processes: spatter bursting events (relatively broadband infrasound) and lava lake-induced tremor (sustained signals peaked at 1 Hz). A comparison of these acoustic signals with results from 3-D finite-difference time-domain wave propagation models shows that while sound speed variability can influence Villarrica’s spectrum, it cannot explain the full extent of the observed frequency excursions. We conclude that source spectrum variability is primarily responsible for the frequency excursions. In conclusion, our work highlights the utility of data collected from a dense distribution of twenty infrasound sensors operating at the summit coupled with numerical modeling of sound radiation.

58 GEOSCIENCES↗

Optimized allocation method of the VSC-MTDC system for frequency regulation reserves considering the cost

In recent years, the interconnection of asynchronous power grids through the VSC-MTDC system has been proposed and extensively studied in light of the potential benefits of economical bulk power exchanges and frequency regulation reserves sharing. This paper proposed an optimized allocation method for sharing frequency regulation reserves among the interconnected power systems and the corresponding frequency regulation control of the VSC-MTDC system under emergency frequency deviation events. Firstly, the frequency regulation reserve classification is proposed. In the classification, the available frequency response capacity reserves of each interconnection are divided into commercial reserves and regular reserves. While the commercial reserves are procured through long-term contracts, the regular reserves are purchased based on market prices of frequency regulation services. Secondly, based on the proposed frequency regulation reserve classification, a novel frequency regulation control is then introduced for the VSC-MTDC system. This control method could minimize the costs of the disturbed power grid for the needed frequency response supports from the other power grids. Simulation verifications are performed on a modified IEEE 39 bus system and a highly reduced power system model representing the North American grids. The simulation verification indicates that the developed frequency regulation control significantly reduced ancillary service costs of the disturbed power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗