Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of ethanol formation in single living cells of Chlamydomonas reinhardtii using synchrotron Fourier Transform Infrared spectromicroscopy

We demonstrate the capability of Fourier-Transform Infra-Red (FITR) spectroscopy to detect metabolite formation by the unicellular algae Chlamydomonas reinhardtii in solution. We show that using a synchrotron source in the microscopy configuration provides a sufficient s/n ratio to detect small molecular species accumulating at a single cell, allowing an increased sensitivity relative to measurements of bulk cultures. The formation of small molecular species, including ethanol and at least one carbonyl containing compound, can be detected with a time resolution of the order of one minute.

60 APPLIED LIFE SCIENCES↗

Detection and measurement of electroreflectance on quantum cascade laser device using Fourier transform infrared microscope

We demonstrate the use of a Fourier Transform Infrared microscope system to detect and measure electroreflectance (ER) from mid-infrared quantum cascade laser (QCL) device. To characterize intersubband transition (ISBT) energies in a functioning QCL device, a microscope is used to focus the probe on the QCL cleaved mirror. The measured ER spectra exhibit resonance features associated to ISBTs under applied electric field in agreement with the numerical calculations and comparable to observed photocurrent, and emission peaks. The method demonstrates the potential as a characterization tool for QCL devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Universal calculation formula and calibration method in Fourier transform profilometry

We propose a universal calculation formula of Fourier transform profilometry and give a strict theoretical analysis about the phase-height mapping relation. As the request on the experimental setup of the universal calculation formula is unconfined, the projector and the camera can be located arbitrarily to get better fringe information, which makes the operation flexible. The phase-height calibration method under the universal condition is proposed, which can avoid measuring the system parameters directly. It makes the system easy to manipulate and improves the measurement velocity. A computer simulation and experiment are conducted to verify its validity. The calculation formula and calibration method have been applied to measure an object of 22.00 mm maximal height. The relative error of the measurement result is only 0.59%. The experimental results prove that the three-dimensional shape of tested objects can be reconstructed exactly by using the calculation formula and calibration method, and the system has better universality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A laboratory demonstration of high-resolution hard X-ray and gamma-ray imaging using Fourier-transform techniques

A laboratory imaging system has been developed to study the use of Fourier-transform techniques in high-resolution hard X-ray and gamma-ray imaging, with particular emphasis on possible applications to high-energy astronomy. Considerations for the design of a Fourier-transform imager and the instrumentation used in the laboratory studies is described. Several analysis methods for image reconstruction are discussed including the CLEAN algorithm and maximum entropy methods. Images obtained using these methods are presented.

Palmer, David↗

Continuous Fourier transform method and apparatus

An input analog signal to be frequency analyzed is separated into N number of simultaneous analog signal components each identical to the original but delayed relative to the original by a successively larger time delay. The separated and delayed analog components are combined together in a suitable number of adders and attenuators in accordance with at least one component product of the continuous Fourier transform and analog signal matrices to separate the analog input signal into at least one of its continuous analog frequency components of bandwidth 1/N times the bandwidth of the original input signal. The original analog input signal can be reconstituted by combining the separate analog frequency components in accordance with the component products of the continuous Fourier transform and analog frequency component matrices. The continuous Fourier transformation is useful for spectrum analysis, filtering, transfer function synthesis, and communications.

Munoz, R. M.↗

Application and sensitivity investigation of Fourier transforms for microwave radiometric inversions

Existing microwave radiometer technology now provides a suitable method for remote determination of the ocean surface's absolute brightness temperature. To extract the brightness temperature of the water from the antenna temperature equation, an unstable Fredholm integral equation of the first kind was solved. Fast Fourier Transform techniques were used to invert the integral after it is placed into a cross-correlation form. Application and verification of the methods to a two-dimensional modeling of a laboratory wave tank system were included. The instability of the Fredholm equation was then demonstrated and a restoration procedure was included which smooths the resulting oscillations. With the recent availability and advances of Fast Fourier Transform techniques, the method presented becomes very attractive in the evaluation of large quantities of data. Actual radiometric measurements of sea water are inverted using the restoration method, incorporating the advantages of the Fast Fourier Transform algorithm for computations.

Holmes, J. J.↗

Electro-optic imaging Fourier transform spectrometer

An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.

Chao, Tien-Hsin↗

Fourier Transform and Reflective Imaging Pyrometry

A stationary Fourier transform pyrometer was used to record mid-wavelength IR spectra in dynamic shock experiments. The gated-IR camera used with this system was also used to record images of light produced and light reflected from shocked metals in order to constrain the dynamic emissivity and provide temperature estimates. This technique will be referred to as reflective imaging pyrometry.

47 OTHER INSTRUMENTATION↗

Hardware schemes for fast Fourier transform, part 7.4A

Real-time fast fourier transformer (FFT) processing of a MST radar data and cost-effective approaches to hardware FFT generation were studied. Previously devised hardware FFT configurations are described including the estimated number of chips used and the time required to perform a 1024-point FFT. The remaining entries in the table correspond to original designs, which presuppose the availability of a microcomputer and a modestly complicated hardware peripheral. These original designs, all of which implement a radix-4 FFT with twiddle factors, are assigned model numbers to make them easier to refer to.

Stitt, G. R.↗

A note on the angular Fourier transformation

It is demonstrated that an angular Fourier transformation is obtained by making a rotation around the non-compact axis of So(2,1), the Lorentz group in three dimensions.

Santhanam, Balu↗

Modeling the viscoplastic micromechanical response of two-phase materials using fast Fourier transforms

A viscoplastic approach using the Fast Fourier Transform (FFT) method for obtaining local mechanical response is utilized to study microstructure-property relationships in composite materials. Specifically, three-dimensional, two-phase digital materials containing isotropically coarsened particles surrounded by a matrix phase, generated through a Kinetic Monte Carlo Potts model for Ostwald ripening, are used as instantiations in order to calculate the stress and strain rate fields under uniaxial tension. The effects of the morphology of the matrix phase, the volume fraction and the contiguity of particles, and the polycrystallinity of matrix phase, on the stress and strain rate fields under uniaxial tension are examined. It is found that the first moments of the stress and strain rate fields have a different dependence on the particle volume fraction and the particle contiguity from their second moments. The average stresses and average strain rates of both phases and of the overall composite have rather simple relationships with the particle volume fraction whereas their standard deviations vary strongly, especially when the particle volume fraction is high, and the contiguity of particles has a noticeable effect on the mechanical response. It is also found that the shape of stress distribution in the BCC hard particle phase evolves as the volume fraction of particles in the composite varies, such that it agrees with the stress field in the BCC polycrystal as the volume of particles approaches unity. Finally, it is observed that the stress and strain rate fields in the microstructures with a polycrystalline matrix are less sensitive to changes in volume fraction and contiguity of particles.

36 MATERIALS SCIENCE↗

Physics-constrained machine learning for electrodynamics without gauge ambiguity based on Fourier transformed Maxwell’s equations

We utilize a Fourier transformation-based representation of Maxwell’s equations to develop physics-constrained neural networks for electrodynamics without gauge ambiguity, which we label the Fourier–Helmholtz–Maxwell neural operator method. In this approach, both of Gauss’s laws and Faraday’s law are built in as hard constraints, as well as the longitudinal component of Ampère–Maxwell in Fourier space, assuming the continuity equation. An encoder–decoder network acts as a solution operator for the transverse components of the Fourier transformed vector potential, $\hat{A}_⟂(k,t)$, whose two degrees of freedom are used to predict the electromagnetic fields. This method was tested on two electron beam simulations. Among the models investigated, it was found that a U-Net architecture exhibited the best performance as it trained quicker, was more accurate and generalized better than the other architectures examined. We demonstrate that our approach is useful for solving Maxwell’s equations for the electromagnetic fields generated by intense relativistic charged particle beams and that it generalizes well to unseen test data, while being orders of magnitude quicker than conventional simulations. We show that the model can be re-trained to make highly accurate predictions in as few as 20 epochs on a previously unseen data set.

97 MATHEMATICS AND COMPUTING↗

High-performance and scalable on-chip digital Fourier transform spectroscopy

Abstract On-chip spectrometers have the potential to offer dramatic size, weight, and power advantages over conventional benchtop instruments for many applications such as spectroscopic sensing, optical network performance monitoring, hyperspectral imaging, and radio-frequency spectrum analysis. Existing on-chip spectrometer designs, however, are limited in spectral channel count and signal-to-noise ratio. Here we demonstrate a transformative on-chip digital Fourier transform spectrometer that acquires high-resolution spectra via time-domain modulation of a reconfigurable Mach-Zehnder interferometer. The device, fabricated and packaged using industry-standard silicon photonics technology, claims the multiplex advantage to dramatically boost the signal-to-noise ratio and unprecedented scalability capable of addressing exponentially increasing numbers of spectral channels. We further explore and implement machine learning regularization techniques to spectrum reconstruction. Using an ‘elastic-D 1 ’ regularized regression method that we develop, we achieved significant noise suppression for both broad (>600 GHz) and narrow (<25 GHz) spectral features, as well as spectral resolution enhancement beyond the classical Rayleigh criterion.

47 OTHER INSTRUMENTATION↗

Two-dimensional Fourier-transform spectroscopy of potassium vapor

Optical two-dimensional Fourier-transform (2DFT) spectroscopy is used to study the coherent optical response of potassium vapor in a thin transmission cell. Rephasing and nonrephasing spectra of the D{sub 1} and D{sub 2} transitions are obtained and compared to numerical simulations. Non-perturbative calculations using the optical Bloch equations give very good agreement with the experimental peak strengths and line shapes. Nonradiative Raman-like coherences are isolated using a different 2DFT projection. Comparison between the optical and Raman linewidths shows that dephasing is due to partially correlated energy fluctuations. Density-dependent measurements show distortion of 2DFT spectra due to pulse propagation effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Gas-phase photodissociation of CH{sub 3}COCN at 308 nm by time-resolved Fourier-transform infrared emission spectroscopy

By using time-resolved Fourier-transform infrared emission spectroscopy, the fragments of HCN(v= 1, 2) and CO(v= 1-3) are detected in one-photon dissociation of acetyl cyanide (CH{sub 3}COCN) at 308 nm. The S{sub 1}(A'), {sup 1}(n{sub O}, {pi}*{sub CO}) state at 308 nm has a radiative lifetime of 0.46 {+-} 0.01 {mu}s, long enough to allow for Ar collisions that induce internal conversion and enhance the fragment yields. The rate constant of Ar collision-induced internal conversion is estimated to be (1-7) x 10{sup -12} cm{sup 3} molecule{sup -1} s{sup -1}. The measurements of O{sub 2} dependence exclude the production possibility of these fragments via intersystem crossing. The high-resolution spectra of HCN and CO are analyzed to determine the ro-vibrational energy deposition of 81 {+-} 7 and 32 {+-} 3 kJ/mol, respectively. With the aid of ab initio calculations, a two-body dissociation on the energetic ground state is favored leading to HCN + CH{sub 2}CO, in which the CH{sub 2}CO moiety may further undergo secondary dissociation to release CO. The production of CO{sub 2} in the reaction with O{sub 2} confirms existence of CH{sub 2} and a secondary reaction product of CO. The HNC fragment is identified but cannot be assigned, as restricted to a poor signal-to-noise ratio. Because of insufficient excitation energy at 308 nm, the CN and CH{sub 3} fragments that dominate the dissociation products at 193 nm are not detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Fourier transform telescope for sub-arcsecond imaging of X-rays and gamma rays

This paper describes a Fourier transform telescope designed to image solar flare X-rays and gamma rays at energies up to 1 MeV with arcsec resolution. The imaging technique makes use of a bigrid collimator divided into a number of smaller areas called subcollimators. The grids in each subcollimator consist of a set of linear apertures so configured that each subcollimator provides a measurement of a single Fourier component of the angular distribution of the source. The imaging concept is therefore a mathematical analog to aperture synthesis in radio astronomy. For X-ray and gamma-ray astronomy, this approach has significant advantages in terms of relaxed requirements for astronomy, this approach has significant advantages in terms of relaxed requirements for position sensitivity in the detector and for control of grid alignment in the large scale telescope structure. The concept of the Fourier transform telescope will be illustrated with numerical parameters of a version now under study for the Pinhole/Occulter Facility.

Crannell, C. J.↗

Slit Function Measurement of An Imaging Spectrograph Using Fourier Transform Techniques

Knowledge of a spectrograph slit function is necessary to interpret the unresolved lines in an observed spectrum. A theoretical slit function can be calculated from the sizes of the entrance slit, the detector aperture when it functions as an exit slit, the dispersion characteristic of the disperser, and the point spread function of the spectrograph. A measured slit function is preferred to the theoretical one for the correct interpretation of the spectral data. In a scanning spectrometer with a single exit slit, the slit function is easily measured. In a fixed grating/or disperser spectrograph, illuminating the entrance slit with a near monochromatic light from a pre-monochrmator or a tunable laser and varying the wavelength of the incident light can measure the slit function. Even though the latter technique had been used successfully for the slit function measurements, it had been very laborious and it would be prohibitive to an imaging spectrograph or a multi-object spectrograph that has a large field of view. We explore an alternative technique that is manageable for the measurements. In the proposed technique, the imaging spectrograph is used as a detector of a Fourier transform spectrometer. This method can be applied not only to an IR spectrograph but also has a potential to a visible/UV spectrograph including a wedge filter spectrograph. This technique will require a blackbody source of known temperature and a bolometer to characterize the interferometer part of the Fourier Transform spectrometer. This pa?er will describe the alternative slit function measurement technique using a Fourier transform spectrometer.

Park, Hongwoo↗