Heat-Flux-Measuring Facility

Apparatus simulates conditions in turbine engines. Automated facility generates and measures transient and steady-state heat fluxes at flux densities from 0.3 to 6 MW/m(Sup2) and temperatures from 100 to 1,200 K. Positioning arm holds heat-flux gauge at focal point of arc lamp. Arm previously chilled gauge in liquid nitrogen in Dewar flask. Cooling water flows through lamp to heat exchanger. Used to develop heat-flux gauges for turbine blades and to test materials for durability under rapidly changing temperatures.

Liebert, Curt H.↗

Drake Antarctic Agile Meteor Radar (DrAAMER) First Results: Configuration and Comparison of Mean and Tidal Wind and Gravity Wave Momentum Flux Measurements with SAAMER

A new-generation meteor radar was installed at the Brazilian Antarctic Comandante Ferraz Base (62.1degS) in March 2010. This paper describes the motivations for the radar location, its measurement capabilities, and comparisons of measured mean winds, tides, and gravity wave momentum fluxes from April to June of 2010 and 2011 with those by a similar radar on Tierra del Fuego (53.8degS). Motivations for the radars include the "hotspot" of small-scale gravity wave activity extending from the troposphere into the mesosphere and lower thermosphere (MLT) centered over the Drake Passage, the maximum of the semidiurnal tide at these latitudes, and the lack of other MLT wind measurements in this latitude band. Mean winds are seen to be strongly modulated at planetary wave and longer periods and to exhibit strong coherence over the two radars at shorter time scales as well as systematic seasonal variations. The semidiurnal tide contribute most to the large-scale winds over both radars, with maximum tidal amplitudes during May and maxima at the highest altitudes varying from approx.20 to >70 m/s. In contrast, the diurnal tide and various planetary waves achieve maximum winds of approx.10 to 20 m/s. Monthly-mean gravity wave momentum fluxes appear to reflect the occurrence of significant sources at lower altitudes, with relatively small zonal fluxes over both radars, but with significant, and opposite, meridional momentum fluxes below approx.85 km. These suggest gravity waves propagating away from the Drake Passage at both sites, and may indicate an important source region accounting in part for this "hotspot".

Fritts, D. C.↗

Heat-flux measurements for the rotor of a full-stage turbine. II - Description of analysis technique and typical time-resolved measurements

An analytical technique for obtaining the time-resolved heat flux of a turbine blade is applied to the case of a TFE 731-2 hp full-stage rotating turbine. In order to obtain the heat flux values from the thin film gage temperature histories, a finite difference procedure is used to solve the heat equation with variable thermal properties. After setting out the data acquisition and analysis procedures, their application is illustrated for three midspan locations on the blade and operation at the design flow function. Results demonstrate that the magnitude of the heat flux fluctuation due to vane-balde interaction is large by comparison to the time-averaged heat flux at all investigated locations; FFT of a portion of the heat flux record illustrates that the dominant frequencies occur at the wake-cutting frequency and its harmonics.

Dunn, M. G.↗

An Investigation of the Compatibility of Radiation and Convection Heat Flux Measurements

A method for determining time-resolved absorbed surface heat flux and surface temperature in radiation and convection environments is described. The method is useful for verification of aerodynamic, heat transfer and durability models. A practical heat flux gage fabrication procedure and a simple one-dimensional inverse heat conduction model and calculation procedure are incorporated in this method. The model provides an estimate of the temperature and heat flux gradient in the direction of heat transfer through the gage. This paper discusses several successful time-resolved tests of this method in hostile convective heating and cooling environments.

Liebert, Curt H.↗

Unsteady Heat-Flux Measurements of Second-Mode Instability Waves in a Hypersonic Boundary Layer

In this paper we report on the application of the atomic layer thermopile (ALTP) heat- flux sensor to the measurement of laminar-to-turbulent transition in a hypersonic flat plate boundary layer. The centerline of the flat-plate model was instrumented with a streamwise array of ALTP sensors and the flat-plate model was exposed to a Mach 6 freestream over a range of unit Reynolds numbers. Here, we observed an unstable band of frequencies that are associated with second-mode instability waves in the laminar boundary layer that forms on the flat-plate surface. The measured frequencies, group velocities, phase speeds, and wavelengths of these instability waves are in agreement with data previously reported in the literature. Heat flux time series, and the Morlet-wavelet transforms of them, revealed the wave-packet nature of the second-mode instability waves. In addition, a laser-based radiative heating system was developed to measure the frequency response functions (FRF) of the ALTP sensors used in the wind tunnel test. These measurements were used to assess the stability of the sensor FRFs over time and to correct spectral estimates for any attenuation caused by the finite sensor bandwidth.

Kergerise, Michael A.↗

Interplanetary magnetic flux - Measurement and balance

A new method for determining the approximate amount of magnetic flux in various solar wind structures in the ecliptic (and solar rotation) plane is developed using single-spacecraft measurements in interplanetary space and making certain simplifying assumptions. The method removes the effect of solar wind velocity variations and can be applied to specific, limited-extent solar wind structures as well as to long-term variations. Over the 18-month interval studied, the ecliptic plane flux of coronal mass ejections was determined to be about 4 times greater than that of HFDs.

Mccomas, D. J.↗

A Convolutional Neural Network for Removing GOES-17 Image Anomalies to Improve CERES Broadband Flux Measurement

Background - CERES provides satellite-based global climate data record of Earth's radiation budget and clouds - CERES = Clouds and the Earth's Radiant Energy System - Measurement anomalies impact cloud retrieval - Incorrect Cloud Phase = Incorrect Flux - Unmitigated bad scanlines will impact climate data records - GOES-17 ABI cooling system anomaly = many bad scanlines at night (~10:30 - 16:30 UTC) - Cleaning imagery of bad scanlines is laborious but necessary - A convolution neural network (CNN) can identify and clean bad scanlines as effectively as a human

Benjamin Scarino↗

Thermal net flux measurements on the Pioneer Venus entry probes

Corrected thermal net (upward minus downward flux) radiation data from four Pioneer Venus probes at latitudes of 4 deg and 60 deg N, and 27 deg and 31 deg S, are presented. Comparisons of these fluxes with radiative transfer calculations were interpreted in terms of cloud properties and the global distribution of water vapor in the lower atmosphere of Venus. The presence of an as yet undetected source of IR opacity is implied by the fluxes in the upper cloud range. It was also shown that beneath the clouds the fluxes at a given altitude increase with latitude, suggesting greater IR cooling below the clouds at high latitudes and a decrease of the water vapor mixing ratios toward the equator.

Revercomb, H. E.↗

Measuring Fluxes Of Heat To A Plasma-Arc Anode

Three probes constructed to provide measurements indicative of conductive, convective, and radiative transfer of heat from free-burning plasma arc to water-cooled copper anode used in generating arc. Each probe consists mainly of copper body with two thermocouples embedded at locations 4 mm apart along length. Thermocouples provide measure of rate of conduction of heat along probe and transfers of heat from plasma to sensing surface at tip of probe. Probes identical except sensing surface of one uncoated and other two coated with different materials to make them sensitive to different components of overall flux of heat.

Sankovic, John M.↗

Corrections of Heat Flux Measurements on Launch Vehicles

Knowledge of aerothermally induced convective heat transfer is important in the design of thermal protection systems for launch vehicles. Aerothermal models are typically calibrated via the data from circular, in-flight, flush-mounted surface heat flux gauges exposed to the thermal and velocity boundary layers of the external flow. Typically, copper or aluminum Schmidt- Boelter gauges, which take advantage of the one-dimensional Fourier's law of heat conduction, are used to measure the incident heat flux. This instrumentation, when surrounded by low-conductivity insulation, has a wall temperature significantly lower than the insulation. As a result of this substantial disturbance to the thermal boundary layer, the heat flux incident on the gauge tends to be considerably higher than it would have been on the insulation had the calorimeter not been there. In addition, radial conductive heat transfer from the hotter insulation can cause the calorimeter to indicate heat fluxes higher than actual. An overview of an effort to develop and calibrate gauge correction techniques for both of these effects will be presented.

Reinarts, Thomas R.↗

Airborne flux measurements and budget estimates of trace species over the Amazon Basin during the GTE/ABLE 2B expedition

In situ airborne measurements of turbulent heat, moisture, momentum, ozone, and carbon monoxide fluxes in a convective boundary layer were obtained over a tropical rain forest between 1100 and 1630 LT on May 4, 1987. The aircraft flight path was chosen so as to fly over the tower site at the Ducke Forest Reserve near Manaus, Amazonas, Brazil. Both turbulence statistics and mean quantities were used to study the budgets of heat, water vapor, ozone, and carbon monoxide. The ozone budget study shows an accumulation rate in the boundary layer of 0.3 + or - 0.2 ppbv/h. The surface resistance to ozone during this flight was determined to be 0.06 + or - 0.03 s/cm, while the aerodynamic resistance was 0.14-0.17 s/cm. Results from the CO budget analysis show a midday accumulation rate of 0.6 + or - 0.3 ppbv/h in the Amazonian boundary layer. The evidence suggests production of CO in the PBL. A source of CO may exist below the lowest flight level (about 150 m), although it was not possible to determine what part of the flux at flight level was due to chemical production and what part may be due to surface emission.

Ritter, John A.↗

Detailed Velocity, Temperature, and Heat Flux Measurements on a Large Scale Film Cooling Model

To investigate the flow physics of turbine film cooling, detailed mean and fluctuating velocity and temperature surveys were made in the turbulent jet flow field behind a row of large scale film cooling holes. Additionally, surface heat transfer, film effectiveness, and turbulent heat flux values were determined. Measurements were made in the NASA Engine Research Building (ERB) SW-6 test facility, which consists of an 8.15-in2 open-inlet wind tunnel with a temperature-controlled secondary flow system. The film-cooling test plate fit into the wind tunnel such that the heat transfer surface formed the wind tunnel floor. This plate consisted of a three-hole array of film cooling holes that were fed from a plenum of different temperature.

Fluid Mechanics↗

Design and operation - Surface flux measurements in FIFE

A general overview of the structure, technology, and methodology of the investigation of surface flux is presented for the First International Satellite Land-Surface Climatology Project Field Experiment. The paper examines the placement of stations, choice of constants, instruments, and micrometeorological techniques, the information system, and comparisons between the data from the sensors and data from different sites. The differences between sites are generally small, and a similarity is noted in the magnitude of fluxes across all sites.

Kanemasu, E. T.↗

Temperature and Radiative Heat Flux Measurements in Microgravity Jet Diffusion Flames

The objective of this project is to provide detailed measurements and modeling analyses of local soot concentration, temperature and radiation heat flux distributions in laminar and turbulent jet diffusion flames under normal (1-g) and reduced gravity (0-g) conditions. Results published to date by these co-PI's and their co-workers include: 1. thermophoretic sampling and size and morphological analyses of soot aggregates in laminar flames under normal and reduced gravity conditions; 2. full-field absorption imaging for soot volume fraction maps in laminar and turbulent flames under normal and reduced gravity conditions; 3. an accurate solver module for detailed radiation heat transfer in nongray nonhomogeneous media; 4. a complete model to include flame structure, soot formation and an energy equation to couple with radiation solver.

Ku, Jerry C.↗

Turbulent heat flux measurements in a transitional boundary layer

During an experimental investigation of the transitional boundary layer over a heated flat plate, an unexpected result was encountered for the turbulent heat flux (bar-v't'). This quantity, representing the correlation between the fluctuating normal velocity and the temperature, was measured to be negative near the wall under certain conditions. The result was unexpected as it implied a counter-gradient heat transfer by the turbulent fluctuations. Possible reasons for this anomalous result were further investigated. The possible causes considered for this negative bar-v't' were: (1) plausible measurement error and peculiarity of the flow facility, (2) large probe size effect, (3) 'streaky structure' in the near wall boundary layer, and (4) contributions from other terms usually assumed negligible in the energy equation including the Reynolds heat flux in the streamwise direction (bar-u't'). Even though the energy balance has remained inconclusive, none of the items (1) to (3) appear to be contributing directly to the anomaly.

Sohn, K. H.↗

Size-resolved Eddy-Covariance Particle Flux Measurement during the TRACER Campaign (Final Report)

The main goal of the TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign was to study aerosol–cloud interactions during deep convection over the Houston area. This project deployed a suite of instrumentation with the aim to (1) quantify turbulent vertical particle fluxes during at DOE-ARM sites, including TRACER, (2) assess hygroscopic growth factors and hygroscopicity parameters of the material driving modal aerosol growth during new particle formation and growth events, (3) derive turbulent aerosol mass fluxes using co-located Doppler LIDAR measurements, and (4) create quality-controlled PI data products to support future research utilizing data collected during the TRACER campaign. This report summarized the main findings from the deployments at two DOE-ARM sites. Briefly, we found that new particle formation may occur aloft, in a residual layer, near the top of the boundary layer. Small grown particles appear later due to downward mixing with daytime turbulence. The species that are responsible for aerosol modal growth had hygroscopicity parameters varying between 0.05 and 0.34. These values systematically depended on the wind sector, suggesting that the chemical composition of the precursors differed. This work demonstrated that lidar retrievals of the elastic backscatter and Doppler velocity can be used to obtain surface number emissions of particles with a diameter greater than 0.53 µm. During TRACER, emission particle number fluxes peaked near ∼ 100 cm−2 s−1. Multiple quality-controlled PI data products that will support future TRACER related science were generated and made publically available.

54 ENVIRONMENTAL SCIENCES↗

Momentum and Heat Flux Measurements in the Exhaust of VASIMR Using Helium Propellant

Electromagnetic thrusters typically use electric and magnetic fields to accelerate and exhaust plasma through interactions with the charged particles in the plasma. The energy required to create the plasma, i.e. ionization energy, is potential energy between the electron and ion. This potential energy is typically lost since it is not recovered as the plasma is exhausted and is known as frozen flow loss. If the frozen flow energy is a small fraction of the total plasma energy, this frozen flow loss may be negligible. However, if the frozen flow energy is a major fraction of the total plasma energy, this loss can severely reduce the energy efficiency of the thruster. Recovery and utilization of this frozen flow energy can improve the energy efficiency of a thruster during low specific impulse operating regimes when the ionization energy is a large fraction of the total plasma energy. This paper quantifies the recovery of the frozen flow energy, i.e. recombination energy, via the process of surface recombination for helium. To accomplish this task the momentum flux and heat flux of the plasma flow were measured and compared to calculated values from electrostatic probe data. This information was used to deduce the contribution of recombination energy to the total heat flux on a flat plate as well as to characterize the plasma conditions. Helium propellant was investigated initially due to its high ionization potential and hence available recombination energy.

Chavers, D. Gregory↗