Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flowmeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Density and Cavitating Flow Results from a Full-Scale Optical Multiphase Cryogenic Flowmeter

Liquid propulsion systems are hampered by poor flow measurements. The measurement of flow directly impacts safe motor operations, performance parameters as well as providing feedback from ground testing and developmental work. NASA Marshall Space Flight Center, in an effort to improve propulsion sensor technology, has developed an all optical flow meter that directly measures the density of the fluid. The full-scale sensor was tested in a transient, multiphase liquid nitrogen fluid environment. Comparison with traditional density models shows excellent agreement with fluid density with an error of approximately 0.8%. Further evaluation shows the sensor is able to detect cavitation or bubbles in the flow stream and separate out their resulting effects in fluid density.

Korman, Valentin↗

Real-time exhaust gas modular flowmeter and emissions reporting system for mobile apparatus

A real-time emissions reporting system includes an instrument module adapted to be detachably connected to the exhaust pipe of a combustion engine to provide for flow of exhaust gas therethrough. The instrument module includes a differential pressure probe which allows for determination of flow rate of the exhaust gas and a gas sampling tube for continuously feeding a sample of the exhaust gas to a gas analyzer or a mounting location for a non-sampling gas analyzer. In addition to the module, the emissions reporting system also includes an elastomeric boot for detachably connecting the module to the exhaust pipe of the combustion engine, a gas analyzer for receiving and analyzing gases sampled within the module and a computer for calculating pollutant mass flow rates based on concentrations detected by the gas analyzer and the detected flowrate of the exhaust gas. The system may also include a particulate matter detector with a second gas sampling tube feeding same mounted within the instrument module.

Breton, Leo Alphonse Gerard↗

An Electrical-Type Indicating Fuel Flowmeter

An electrical-type meter has been developed for measuring mass rates of flow of gasoline or other nonconducting fluids. Its temperature dependence is small over a large range and it has no known vibrational or viscosity errors. The maximum temperature rise is less than 5 C. The rates of flow, measurable within 1% with the present instrument, are approximately 100 to 1,000 or more pounds of gasoline per hour when a potentiometer is used, or 100 to 300 pounds per hour when a deflection-type meter is used.

Tozier, Robert E.↗

On the Performance of Small-Sized Venturi Flowmeters in Cavitating and Non-Cavitating Flow Regimes

The performance of venturi in the cavitating and non-cavitating flow regimes has been discussed theoretically and experimentally. Pressure drop test data with water was obtained with a 0.0355 inch throat venturi with pressure drop measured between the inlet and the outlet of the venturi, typical of practical venturi measurements on spacecraft. The pressure drop data acquired in the non-cavitating regime at relatively low flow rates display low Reynolds number effects on the discharge coefficient. A theoretical discussion of the corresponding discharge coefficients in the two flow regimes along with comparisons with test data are presented. For non-cavitating flow regime of unique venturi geometries of relatively small throat size, test data required low Reynolds number correction factor for the discharge coefficient in terms of throat Reynolds number. The application of existing theory is not straightforward for the unique geometries under consideration.

Max Kandula↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methods for Determining Blood Flow Through Intact Vessels of Experimental Animals Under Conditions of Gravitational Stress and in Extraterrestrial Space Capsules

Work during the initial six months of this program has proceeded along three lines: (1) technical development of blood flowmeter instrumentation: (2) surgical considerations related to special problems of chronic implantation of flowmeter probes: (3) study of the relationship between levels of blood flow and organ activity. Principal engineering effort has been focused on the fundamental phenomena operative in the flowmeter probe and on probe design. Two probes have been constructed and a third is nearing completion. A previously unrecognized source of zero drift has been discovered and corrected. has been designed, assembled, tested and successfully employed in work on the several probes. A significant innovation which has been introduced is the use of a transformer coupled input for suppression of unwanted common mode signals. New low noise transistor amplifiers with characteristics suitable for space vehicle packaging are being developed. Linearity of the present apparatus has been found to extend at least into the near turbulent flow region. Attention has been directed to the two vascular beds of physiologic interest that present particular problems with regard to chronic implantation of flowmeter probes, the myocardium and the liver. Surgical techniques have been perfected that will permit myocardial and liver blood flow measurement. Two groups of animals have successfully undergone surgery and await the implantation of probes. Studies of the relationship between organ blood flow and levels of physiologic activity have been initiated. The first organ system studied was the heart, For the first time autoregulatory mechanisms have been demonstrated within the myocardial vascular bed which rapidly and precisely maintain coronary blood flow at a level i n keeping with the magnitude of cardiac work, Following a summary statement of the status of the program, the work performed is described, A financial review of expenditures incurred and a proposal for future funding are appended,

Shaw, R. F.↗

A urine volume measurement system

An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

Poppendiek, H. F.↗

Airflow calibration of a bellmouth inlet for measurement of compressor airflow in turbine-powered propulsion simulators

The development of turbine-powered propulsion simulators for high-speed wind tunnel models requires a bellmouth inlet which can accurately measure compressor-inlet airflow. A bellmouth inlet was instrumented with total pressure probes, static pressure probes, and thermocouples for airflow measurement. The bellmouth flowmeter against a critical venturi flowmeter was calibrated. The calibration was done at four inlet pressures ranging from 58 to 114 kPa. The bellmouth discharge coefficient varied as a function of bellmouth-throat Mach number. Over the range of Reynolds number and Mach number tested the Reynolds number was not a significant influence on the discharge coefficient. The overall accuracy of the bellmouth inlet as a flowmeter was estimated to be + or - 0.5% of the flowmeter reading.

Smith, S. C.↗

Sodium Hydrogen Sensor and Acoustic Flow Sensor Development

This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a high-resolution automatic digital (urine/electrolytes) flow volume and rate measurement system of miniature size

To aid in the quantitative analysis of man's physiological rhythms, a flowmeter to measure circadian patterns of electrolyte excretion during various environmental stresses was developed. One initial flowmeter was designed and fabricated, the sensor of which is the approximate size of a wristwatch. The detector section includes a special type of dielectric integrating type sensor which automatically controls, activates, and deactivates the flow sensor data output by determining the presence or absence of fluid flow in the system, including operation under zero-G conditions. The detector also provides qualitative data on the composition of the fluid. A compact electronic system was developed to indicate flow rate as well as total volume per release or the cumulative volume of several releases in digital/analog forms suitable for readout or telemetry. A suitable data readout instrument is also provided. Calibration and statistical analyses of the performance functions required of the flowmeter were also conducted.

Liu, F. F.↗

Technique for measuring gas conversion factors

A method for determining hydrocarbon conversion factors for a flowmeter. A mixture of air, O2 and C sub x H sub y is burned and the partial paressure of O2 in the resulting gas is forced to equal the partial pressure of O2 in air. The flowrate of O2 flowing into the mixture is measured by flowmeter and the flowrate of C sub x H sub y flowing into the mixture is measured by the flowmeter conversion factor is to be determined. These measured values are used to calculate the conversion factor.

Singh, J. J.↗

Vortex-Shedding Meters For Liquid And Liquid/Gas Flows

Flowmeters without moving parts developed as replacements for conventional turbine flowmeters. No maintenance required so meters installed permanently. In vortex-shedding flowmeter, piezoelectric or other suitable transducer probe senses changes of pressure caused by passage of vortices. Electronic circuitry processes pressure-change signals to extract vortex-passage frequency representing rate of flow.

Howard, Robert H.↗

Estimating irrigation water use from remotely sensed evapotranspiration data: Accuracy and uncertainties at field, water right, and regional scales

Irrigated agriculture is the dominant user of water globally, but most water withdrawals are not monitored or reported. As a result, it is largely unknown when, where, and how much water is used for irrigation. Here, we evaluated the ability of remotely sensed evapotranspiration (ET) data, integrated with other datasets, to calculate irrigation water withdrawals and applications in an intensively irrigated portion of the United States. We compared irrigation calculations based on an ensemble of satellite-driven ET models from OpenET with reported groundwater withdrawals from hundreds of farmer irrigation application records and a statewide flowmeter database at three spatial scales (field, water right group, and management area). At the field scale, we found that ET-based calculations of irrigation agreed best with reported irrigation when the OpenET ensemble mean was aggregated to the growing season timescale (bias = 1.6–4.9%, R 2 = 0.53–0.74), and agreement between calculated and reported irrigation was better for multi-year averages than for individual years. At the water right group scale, linking pumping wells to specific irrigated fields was the primary source of uncertainty. At the management area scale, calculated irrigation exhibited similar temporal patterns as flowmeter data but tended to be positively biased with more interannual variability. Disagreement between calculated and reported irrigation was strongly correlated with annual precipitation, and calculated and reported irrigation agreed more closely after statistically adjusting for annual precipitation. The selection of an ET model was also an important consideration, as variability across ET models was larger than the potential impacts of conservation measures employed in the region. From these results, we suggest key practices for working with ET-based irrigation data that include accurately accounting for changes in soil moisture, deep percolation, and runoff; careful verification of irrigated area and well-field linkages; and conducting application-specific evaluations of uncertainty.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Segmented ball valve is easy to open and close

Segmented ball valve and flowmeter in the same spherical housing provide a valve that will handle large fluid volume without bulkiness and weight of blade valves or conventional ball valves. The valve is easily opened or closed and the flowmeter remains stationary, so errors are eliminated.

Prono, E.↗

Economic method for measuring ultra-low flow rates of fluids

Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate.

Bogdanovic, J. A.↗