3D reconstruction of an inertial-confinement fusion implosion with neural networks using multiple heterogeneous data sources

3D asymmetries are major degradation mechanisms in inertial-confinement fusion implosions at the National Ignition Facility (NIF). These asymmetries can be diagnosed and reconstructed with the neutron imaging system (NIS) on three lines of sight around the NIF target chamber. Conventional tomographic reconstructions are used to reconstruct the 3D morphology of the implosion using NIS [Volegov et al., J. Appl. Phys. 127, 083301 (2020)], but the problem is ill-posed with only three imaging lines of sight. Asymmetries can also be diagnosed with the real-time neutron activation diagnostics (RTNAD) and the neutron time-of-flight (nToF) suite. Since the NIS, RTNAD, and nToF each sample a different part of the implosion using different physical principles, we propose that it is possible to overcome the limitations of too few imaging lines of sight by performing 3D reconstructions that combine information from all three heterogeneous data sources. This work presents a new machine learning-based reconstruction technique to do just this. By using a simple physics model and group of neural networks to map 3D morphologies to data, this technique can easily account for data of multiple different types. A simple proof-of-principle is presented, demonstrating that this technique can accurately reconstruct a hot-spot shape using synthetic primary neutron images and a hot-spot velocity vector. In particular, the hot-spot’s asymmetry, quantified as spherical harmonic coefficients, is reconstructed to within ±4% of the radius in 90% of test cases. In the future, this technique will be applied to actual NIS, RTNAD, and nToF data to better understand 3D asymmetries at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

Benchmark microgravity experiments and computations for 3D dendritic-array stability in directional solidification

In this study, we present a comprehensive quantitative analysis of stability bands for dendritic arrays during directional solidification of a transparent succinonitrile-0.46 wt % camphor alloy, spanning a broad range of pulling velocities. Taking advantage of the microgravity environment aboard the International Space Station where most convection effects are suppressed, we obtain unique measurements that quantify the stable primary spacing range of spatially extended three-dimensional dendritic array structures under purely diffusive growth conditions. Through carefully designed velocity jump experiments and detailed examination of sub-grain boundary dynamics, we characterize key instabilities, including elimination and tertiary branching, shedding new light on the mechanisms governing dynamic dendritic spacing selection in extended 3D arrays. Phase field simulations are performed to characterize the stability limits of dendritic array structures for quantitative comparison with the flight experiments. Although the simulations capture general trends, significant deviations are noted at the upper stability boundary, indicating the influence of additional, unexplored factors. These findings contribute to a deeper understanding of dendritic growth dynamics and offer valuable benchmark data that could aid in refining predictive models and improving control of dendritic microstructures in metallurgical applications.

36 MATERIALS SCIENCE↗

NDVI and Multispectral Images, UAS Flights, Council Road Site, Seward Peninsula, Alaska, June 2022

The dataset contains Normalized Difference Vegetation Index (NDVI) and multispectral images collected on June 18, 2022 using an UAS (Unmanned Aerial System) Yuneec H520, Mapir Survey 3, and Parrot Sequoia cameras. This data was created to accompany the following datasets:- NGEE Arctic CO2, CH4 and Energy Eddy-Covariance (EC) Flux Tower Auxiliary Measurements, Council Road Mile Marker 71, Seward Peninsula, Alaska (https://doi.org/10.5440/1526749)- Sun-induced chlorophyll fluorescence/eddy covariance measurements at NGEE Arctic Council site, Seward Peninsula, Alaska, 2022 (https://doi.org/10.15485/2466175)- NGEE Arctic Meteorological Data from Instrumented PCDC Stations, Council Site, Seward Peninsula, Alaska, 2018 - 2023 (https://doi.org/10.5440/1529604)Survey 3 is RGN (Red, Greeen, Near Infra Red) camera with 87° Horizontal Field of View (HFOV) (19mm) f/2.8 Aperture, 550nm/660nm/850nm (Red+Green+NIR) filter transmission and produced geo referenced jpg and raw format images. Parrot Sequoia is a camera with 16 megapixel RGB (Red, Green, Blue) sensor and 1.2 megapixel monochrome sensors in discrete spectral bands: Green (550nm - 40Nm Bandwidth), Red (660nm - 40nm Bandwidth), Red Edge (735nm - 10nm Bandwidth) and Near Infrared (790nm - 40nm Bandwidth).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

High Yield nTOF Spec A and NP Filter Holders Static and Seismic Analysis

The Neutron Time-of-Flight (nTOF) detectors located in the Alcove and at the North Pole (Spec A and Spec NP respectively) need filtering in the beam path to enable them to take data at NIF yields above 5MJ. The filtering consists of 12cm of filter material divided into four, 3cm thick “pucks.” The pucks are 7cm in diameter. Each puck is mounted into a rotatable stage, also called a Filter Flipper, that can bring it into and out of the beam path, see Figure 1-1. These stages are bolted onto a plate that connects the filter stages to the mounting hardware used to position them in the NIF Target Bay. The top-level filter mount assemblies will be permanently mounted in the facility; removal is possible if needed for NIF maintenance, but the design intent is for the assemblies to remain in their locations after alignment is completed.

42 ENGINEERING↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Notes on Real-Beam Ground Mapping with Monopulse Radar

The spatial awareness required of modern flight systems is facilitated by images generated by ground-mapping radar. In the forward and aft directions, synthetic aperture techniques are not viable, leaving us with enhancing real aperture radar data. Enhancing real aperture radar data with monopulse information can be achieved with any of several monopulse beam sharpening techniques. Two such algorithms are discussed.

47 OTHER INSTRUMENTATION↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Ultrafast Laser Welding and Terahertz Time-domain Spectroscopy of Soda Lime Silicate Glass

Joining and welding techniques of similar and dissimilar materials have reached their limits due to the inflexibility of adapting dielectric materials, e.g., glasses and ceramics, reproducibility for transparent materials, and cycle process time. The ability to join pieces of glasses using laser irradiation allows rapid processing of vacuum insulating glass (VIG) for a widening range of commercial energy-efficient applications. We have used a 1064-nm laser wavelength with 15 picoseconds pulse width and a 155-kHz repetition rate to weld commercial plate glass pieces. The welded samples were characterized via x-ray fluorescence (XRF), time-of-flight secondary ion mass spectrometry (TOF–SIMS), polarimetry, and terahertz time-domain spectroscopy (THz-TDS) to determine the integrity of the weld and chemical changes in the welded areas. Our data shows no significant changes in glass chemistry and structure on average over nano- to micro-scales occurred from the welding process within the limits of the characterization tools. Our results demonstrate successful welding of glass plates without significant changes in the glass chemistry, structure, or properties in the laser-modified region or strains in the bulk glass.

Matthies, Kathleen [ORNL] (ORCID:0009000213135441)↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

Constraining hydrodynamic models of inertial confinement fusion implosions using capsule surrogate experiments

We conduct capsule surrogate experiments at the National Ignition Facility to calibrate radiation hydrodynamic simulations to infer hydrodynamic conditions that are not observable in indirect drive ignition implosions. We tune the simulations by applying laser power and cross beam energy transfer (CBET) saturation multipliers to match the observables from capsule surrogate experiments. Shock timing, velocity, and symmetry are measured in liquid D 2 filled Keyhole capsule surrogate experiments and implosion trajectory, stagnation time, and shape time history are measured in in-flight 2D backlit x-ray radiography experiments (“2DConA”) of D 2 gas filled capsule implosions. Calibrated simulations suggest that the N210808 ignition implosion (fusion target gain = 0.7) had a shell mass remaining at stagnation of less than the nominal %5 (3.8%) and resulted in less confinement. For N221204, the shell was made 5.75 μm thicker to trade implosion velocity for increased confinement and resulted in a target gain = 1.5 with a shell mass remaining of 5.7%. Furthermore, a single adjusted model can reproduce all shock timing data as changes are made to shell thickness (79–85 μm) and laser wavelength separation (1.8–4.0 Å). However, for the 2DConA implosions, a 5% variation in the peak power laser multipliers and a 30% variation in late-time CBET between experiments are needed to match the observed stagnation times, in-flight $P_2$ shape, and hot-spot $P_2$ shape. While progress is being made to improve the models in simulations using focused experiments, capsule surrogate experiments will continue to be needed to optimize future ignition designs.

Lasers↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

Search for the production of Higgs-portal scalar bosons in the NuMI beam using the MicroBooNE detector

We present the strongest experimental limits to date on the mixing angle, 𝜃, with which a new scalar particle, 𝑆, mixes with the Higgs field in the mass range 110 MeV < 𝑚 𝑆 <155 MeV. This result uses the MicroBooNE liquid argon time projection chamber to search for decays of these Higgs-portal scalar particles through the 𝑆 → 𝑒 + ⁢𝑒 − channel with the decays of kaons in the NuMI neutrino beam acting as the source of the scalar particles. The analysis uses an exposure of 2.01 × 10 21 protons on target of NuMI beam data including periods when the beam focusing system was configured to focus positively charged hadrons and separate periods when negatively charged hadrons were focused. The analysis searches for scalar particles produced from kaons decaying in flight in the beam’s decay volume and at rest in the target and absorber. At 𝑚 𝑆 =125 MeV (𝑚 𝑆 =150 MeV) we set a limit of 𝜃 < 3.19 ×10 −4 (𝜃 < 2.79 ×10 −4 ) at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stereo-vision thermal imaging system for tracking flying animals in wind farm areas (CRADA #763) Abstract

CRADA 763: abstract ThermalTracker-3D (TT3D) is a stereo vision thermal imaging system that provides 3D flight information on detected birds, bats, and other flying targets. The system was initially developed for use in the siting and monitoring of offshore wind projects to establish pre-construction and operation collision risk data but can be applied to terrestrial wind energy projects as well as national security monitoring. This technology will reduce monitoring cost, decrease processing time, and provide more accurate data for wind energy developers/operators and regulatory agencies. While the current technology is at a high level of readiness, Technology Readiness Level (TRL) 7, there remain several barriers to commercialization, particularly around ease-of-use, that result in a low Adoption Readiness Level (ARL). The proposed work will advance commercialization readiness by streamlining calibration methods for built systems. This work will:1. 1. develop a software package for factory and dynamic calibration processes 2. test that package with existing prototype TT3D systems, and 3. conduct outreach with industry end-users.

ThermalTracker↗

Machine Learning Correlation of Electron Micrographs and ToF-SIMS for the Analysis of Organic Biomarkers in Mudstone

The spatial distribution of organics in geological samples can be used to determine when and how these organics were incorporated into the host rock. Mass spectrometry (MS) imaging can rapidly collect a large amount of data, but ions produced are mixed without discrimination, resulting in complex mass spectra that can be difficult to interpret. Here, we apply unsupervised and supervised machine learning (ML) to help interpret spectra from time-of-flight-secondary ion mass spectrometry (ToF-SIMS) of an organic-carbon-rich mudstone of the Middle Jurassic of England (UK). It was previously shown that the presence of sterane molecular biomarkers in this sample can be detected via ToF-SIMS (Pasterski, M. J. et al., Astrobiology 2023, 23, 936). We use unsupervised ML on scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) measurements to define compositional categories based on differences in elemental abundances. We then test the ability of four ML algorithms─k-nearest neighbors (KNN), recursive partitioning and regressive trees (RPART), eXtreme gradient boost (XGBoost), and random forest (RF)─to classify the ToF-SIM spectra using (1) the categories assigned via SEM-EDS, (2) organic and inorganic labels assigned via SEM-EDS, and (3) the presence or absence of detectable steranes in ToF-SIMS spectra. In terms of predictive accuracy and balanced accuracy, KNN was the best performing model and RPART the worst. The feature importance, or the specific features of the ToF-SIM spectra used by the models to make classifications, cannot be determined for KNN, preventing posthoc model interpretation. Nevertheless, the feature importance extracted from the other models was useful for interpreting spectra. In conclusion, we determined that some of the organic ions used to classify biomarker containing spectra may be fragment ions derived from kerogen which is abundant in this mudstone sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.