Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOULING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The foul side of 'clean coal'

As power plants face new air pollution control, ash piles and their environmental threats are poised to grow. Recent studies have shown that carcinogens and other contaminants in piles of waste ash from coal-fired power plants can leach into water supplies at concentrations exceeding drinking water standards. Last year an ash dam broke at the 55-year old power plant in Kingston, TN, destroying homes and rising doubts about clean coal. Despite the huge amounts of ash generated in the USA (131 mtons per year) no federal regulations control the fate of ash from coal-fired plants. 56% of this is not used in products such as concrete. The EPA has found proof of water contamination from many operating ash sites which are wet impoundments, ponds or reservoirs of some sort. Several member of Congress have show support for new ash-handling requirements and an inventory of waste sites. Meanwhile, the Kingston disaster may well drive utilities to consider dry handling. 3 photos.

01 COAL, LIGNITE, AND PEAT↗

Fouling-resistant, chlorine-tolerant zwitterionic membranes for treatment of produced water in the Permian Basin

ZwitterCo, Inc. performed a two-year study on the use of its superfiltration membrane products for the treatment of produced water from the Permian Basin, including pilot testing using actual produced water samples. The results showed a highly competitive techno-economic analysis compared to existing produced water treatment options and show a path towards beneficial reuse of produced water.

04 OIL SHALES AND TAR SANDS↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Investigation of potential causes of production limiting fouling within SWPF due to mercury solids formation during pH swings within the SWPF process

The Salt Waste Processing Facility (SWPF) goal to investigate the use a high sodium Salt Batch 5 Qualification sample as the radioactive salt solution for mixing tests meant to evaluate the propensity for solids formation between the 5.6 M sodium clarified salt solution (CSS) and scrub solutions (0.05 M HNO 3 and 0.025 M NaOH solutions) during pH changes has been completed at SRNL. The key results and conclusions from this investigation to evaluate the propensity for solids formation between CSS and scrub solutions because of pH fluctuations include the following: None of the 8 test matrices, involving the mixing/titrating of scrub solution with CSS and vice versa, showed any visible evidence for the formation of solids with pH changes. The average turbidity measurements for these 8 tests, excluding test 7, was 21.6 ± 0.4 NTU. This average turbidity value is within 2 sigma of the baseline turbidity value of 20.5 NTU for the CSS only without added scrub solutions. However, only in test 7, which involved the titrating of CSS into dilute nitric acid scrub solution (0.05 M HNO 3 solution), was a small measurable change in the turbidity of the mixture observed at 31.9 ºC. On the other hand, the equivalent test (instantaneous addition of CSS into 0.05 M HNO 3 ) gave an average turbidity measurement value of 21.6 ± 0.6 NTU at a temperature of 24.0 ºC. This difference in turbidity measurement has been attributed to either instrument performance errors or the effect of temperature. It is recommended that these CSS and scrub solution mixing tests be performed with corresponding simulant solutions in a non-radioactive environment. A simulant environment will aid in the full integration of a pH and turbidity meter equipment with the experimental set up. A new detection method, preferable a laser-based method, may be needed in detecting and confirming the precipitation of fine particulates at the right blending times and pH fluctuations in the solution mixtures. On the other hand, the differing free OH concentrations (~2 M in CSS), H + concentrations (0.05 M HNO 3 ) for the titrants and the bulk solutions, may make it almost impossible to observe a neutral pH or a pH in the range of 7-9, where the potential for solids formation is maximized and leads to possible precipitation of minerals like aluminum hydroxides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗