Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, a μ ≡ ( g μ - 2 ) / 2 , from the Fermilab Muon g - 2 Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, ω ˜ p ′ , and of the anomalous precession frequency corrected for beam dynamics effects, ω a . From the ratio ω a / ω ˜ p ′ , together with precisely determined external parameters, we determine a μ = 116 592 057 ( 25 ) × 10 - 11 (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain a μ ( FNAL ) = 116 592 055 ( 24 ) × 10 - 11 (0.20 ppm). The new experimental world average is a μ ( exp ) = 116 592 059 ( 22 ) × 10 - 11 (0.19 ppm), which represents a factor of 2 improvement in precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BigData Express: Toward Schedulable, Predictable, and High-Performance Data Transfer

Big Data has emerged as a driving force for scientific discoveries. Large scientific instruments (e.g., colliders, and telescopes) generate exponentially increasing volumes of data. To enable scientific discovery, science data must be collected, indexed, archived, shared, and analyzed, typically in a widely distributed, highly collaborative manner. Data transfer is now an essential function for science discoveries, particularly within big data environments. Although significant improvements have been made in the area of bulk data transfer, the currently available data transfer tools and services can not successfully address the high-performance and time-constraint challenges of data transfer required by extreme-scale science applications for the following reasons: disjoint end-to-end data transfer loops, cross-interference between data transfers, and existing data transfer tools and services are oblivious to user requirements (deadline and QoS requirements). Fermilab has been working on the BigData Express project to address these problems. BigData Express seeks to provide a schedulable, predictable, and high-performance data transfer service for big data science. The BigData Express software is being deployed and evaluated at multiple research institutions, which include UMD, StarLight, FNAL, KISTI, KSTAR, SURFnet, Ciena, and other sites. Meanwhile, the BigData Express research team is collaborating with the StarLight International/National Communications Exchange Facility to deploy BigData Express at various research platforms, including Pacific Research Platform, National Research Platform, and Global Research Platform. It is envisioned that we are working toward building a high-performance data transfer federation for big data science.

Lu, Qiming↗

Enhanced Machine-Learning Flow for Microwave-Sensing Systems for Contaminant Detection in Food

The presence of foreign bodies in packaged food is a serious concern for both fnal consumers (allergies, injuries, choking) and food manufacturers (reputation and economic losses). In particular, low-density plastics, glass and wood splinters are hard to detect even by the most advanced X-ray imagers. One solution is Machine-Learning-based Microwave Sensing (MLMWS): a non-invasive, contactless, and real-time method which uses a machine-learning (ML) classifer to analyze the scattered microwaves from the irradiated target object. In this paper, we want to extend our previous work about contaminant detection in cocoa-hazelnut spread jars by proposing an enhanced ML flow to increase the accuracy of the ML classifier. For the first time in this case study, we use a multi-class classifier, we train it with scattering parameters measured at multiple microwave frequencies, with a new pre-processing scaler, data augmentation, quantization-aware training and a pruning schedule. The results show a contaminant detection multi-class accuracy of 94.167% with a latency of 26 µs when targeting an AMD/Xilinx Kria K26 FPGA. Finally, we released our datasets publicly to OpenML.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The HL-LHC Low-β Quadrupole Magnet MQXF: From Short Models to Long Prototypes

Among the components to be upgraded in LHC interaction regions for the HiLumi-LHC projects are the inner triplet (or low-β) quadrupole magnets, denoted as Q1, Q2a, Q2b, and Q3. Here, the new quadrupole magnets, called MQXF, are based on Nb3Sn superconducting magnet technology and operate at a gradient of 132.6 T/m, with a conductor peak field of 11.4 T. Q1 and Q3 are composed of magnets (called MQXFA) fabricated by the U.S. Accelerator Upgrade Project (AUP), with a magnetic length of 4.2 m. Q2a and Q2b consist of magnets (called MQXFB) fabricated by CERN, with a magnetic length of 7.15 m. After a series of short models, constructed in close collaboration by the US and CERN, the development program is now entering in the prototyping phase, with CERN on one side and BNL, FNAL, and LBNL on the other side assembling and testing their first long magnets We provide in this paper a description of the status of the MQXF program, with a summary of the short model test results, including quench performance, and mechanics, and an update on the fabrication, assembly, and test of the long prototypes.

43 PARTICLE ACCELERATORS↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

Test of Superconducting Wires and Rutherford Cables With High Specific Heat

High-field accelerator magnets made of state-of-the-art Nb 3 Sn Rutherford cables demonstrate relatively long trainings due to sudden heat depositions originated by thermo-mechanical perturbations in the magnet coils. Coil sensitivity to these perturbations can be reduced by increasing the specific heat, Cp, of major coil components - strands, or whole cable, or epoxy. The R&D on all these three approaches is in progress. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using a thin composite Cu/Gd 2 O 3 tape. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. In this work, Cu/Gd 2 O 3 ribbons with ~30% of Gd 2 O 3 powder and two different thicknesses were produced by Hyper Tech Research, Inc. Wire and cable samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for the Minimum Quench Energy (MQE). At 80%Ic, the MQE gain average over the tested magnetic field range of the NbTi cable with high-Cp tape on both sides was ~1.3. The MQE gain average of the NbTi wire wrapped with the high-Cp ribbon was 3.1.

43 PARTICLE ACCELERATORS↗

Assembly and Pre-Loading Specifications for the Series Production of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC

We report the High Luminosity LHC (HL-LHC) Project is planning to install 16 cold-masses made with Nb 3 Sn quadrupole magnets in the LHC Interaction Regions to significantly increase its luminosity. Half of these cold masses are fabricated at BNL, FNAL, and LBNL under the US Accelerator Research Program (AUP). Each cold mass includes two identical Nb 3 Sn quadrupole magnets, called MQXFA with a magnetic length of 4.2 m. Currently, the AUP project has completed the fabrication and test of the first 5 pre-series magnets, and is working on the following 16 magnets for the series production. The brittleness and strain sensitivity of the Nb 3 Sn superconducting material requires a careful definition of the allowable maximum stress in the windings during magnet assembly and pre-load, and a tight control of their variation within the whole coil length. Therefore, a series of assembly and pre-load specifications have been defined with the goals of minimizing the risk of conductor degradation and providing the mechanical support required to reach the nominal current during powering. In this paper we present the specifications defined for the MQXFA magnets and applied during the different assembly phases and during the pre-load process of the first 5 pre-series magnets.

43 PARTICLE ACCELERATORS↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. The background magnetic field of 15 T in the HFVMTF will be produced by a magnet provided by LBNL. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES), and will serve as a superconducting cable test facility in high magnetic fields and a wide range of temperatures for HEP and FES communities. This facility will also be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program (MDP). The paper describes the status of the facility, including construction, cryostat designs, top and lambda plates, and systems for powering, and quench protection and monitoring.

43 PARTICLE ACCELERATORS↗

Commissioning, Performance, and Effect of the Quench Current-Boosting Device on a Dedicated Superconducting Magnet

Superconducting magnet training is one of the accelerator related issues attracting attention due to significant operational costs and time budget associated to it. It is especially worrisome that magnets based on the “next-generation” Nb 3 Sn technology are affected by long training. While various efforts are underway to better understand and resolve the problem a parallel path could also be investigated, a path bypassing the issue. Following the concept of fast induced over-current during magnet powering, FNAL has developed an upgradable capacitor-based device to discharge through a superconducting magnet at quench detection or operator chosen time. The 0.4 F/1 kV device has been tested on a 1-m-long dipole-coil in a “mirror” magnet configuration and conclusive results on magnet training elimination have been observed. Here in this paper we discuss the main characteristics of the device, compare simulated response and actual performance, elaborate on test drivers and outcomes. Next steps and perspectives for future use are debated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

43 PARTICLE ACCELERATORS↗

Fermilab proton accelerator complex status and improvement plans

Fermilab carries out an extensive program of accelerator-based high energy particle physics research at the Intensity Frontier that relies on the operation of 8 GeV and 120 GeV proton beamlines for a n umber of fixed target experiments. Routine operation with a world-record 700kW of average 120 GeV beam power on the neutrino target was achieved in 2017 as the result of the Proton Improvement Plan (PIP) upgrade. There are plans to further increase the power to 900 – 1000 kW. The next major upgrade of the FNAL accelerator complex, called PIP-II, is under development. It aims at 1.2MW beam power on target at the start of the LBNF/DUNE experiment in the middle of the next decade and assumes replacement of the existing 40-years old 400 MeV normal-conducting Linac with a modern 800 MeV superconducting RF linear accelerator. There are several concepts to further double the beam power to >2.4MW after replacement of the existing 8 GeV Booster synchrotron. In this article we discuss current performance of the Fermilab proton accelerator complex, the upgrade plans for the next two decades and the accelerator R&D program to address cost and performance risks for these upgrades.

43 PARTICLE ACCELERATORS↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon g - 2 experiment at Fermilab

The muon magnetic anomaly aµ = (gµ - 2)/2 is a low-energy observable,which can be both measured and computed to high precision, making ita sensitive test of the Standard Model (SM). In April 2021, the E989 Collaborationat Fermilab National Accelerator Laboratory (FNAL) published the first resultbased on the first year of data taking (Run-1), and in August 2023 a new resultwas published based on two more years of data taking (Run-2 and Run-3). Thenew result was in agreement with the first one and with the previous experimentat Brookhaven National Laboratory (BNL), and the combination of these resultsbrought the uncertainty on the experimental measurement of aµ to the unprecedentedvalue of 0.19 parts per million (ppm). This paper will present details aboutthe improvements and upgrades since the 2021 result, and it will describe the finalstatistical and systematic sources of uncertainty on .a in the 2023 result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Muon Neutrino Charged-Current Interactions in the MicroBooNE Detector

The MicroBooNE experiment is a short-baseline neutrino experiment at the Fermi National Accelerator Laboratory (FNAL) in the US, receiving a highly pure muon neutrino beam from the Booster Neutrino Beam (BNB) and taking data since October 2015. The main physics goal of MicroBooNE is to clarify the nature of the low-energy excess of electron-like events observed by the MiniBooNE Cherenkov detector, which due to its detector technology is unable to resolve whether the observed excess shower-like events are due to electrons or photons. Instead, MicrooBooNE employs cutting-edge liquid argon time projection chamber (LArTPC) technology, which offers excellent spatial and calorimetric resolution, which makes it possible to reconstruct complex neutrino interactions and to efficiently distinguish different final state particle types. This thesis presents a fully-automated event selection of interactions of the types ν μ +Ar → μ - + X and ν μ + Ar → μ - + p + X developed using the Pandora multi-algorithm approach to pattern recognition for LArTPC experiments. The analysis in this work is performed on a subset of the MicroBooNE Run 1 dataset corresponding to 4.52 × 10 19 protons on target acquired by the MicroBooNE detector between February and October 2016. The analysis quantifies the main signal and background interaction channels that produce a reconstructed neutrino interaction with one and two particles in the final state, and quantifies the extent to which different aspects of the Pandora reconstruction affect the selection performance. MicroBooNE is a surface detector, and therefore cosmic-ray tracks are the main observed background. A direction fitting procedure has been implemented in this analysis to formulate directional probabilities, using the Bethe equation and the high-resolution calorimetric information of MicroBooNE, to reduce this cosmic-ray background. This functionality is used to enhance the efficiency of the Pandora cosmic ray tagging logic, and the impact of this procedure on the reconstruction and event selection performance is analysed. The result of this study is two fully-automated selections of ν μ +Ar → μ - + X (57.91% pure) and ν μ + Ar → μ - + p + X (78.30% pure) with efficiencies of 64.35% and 62.65%, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rework Recipe Development, Analysis and Results of Select 9-Cell Cavities for LCLS-II

The SLAC National Accelerator Laboratory is currently constructing a major upgrade to its accelerator, the Linac Coherent Light Source II (LCLS-II). Several Department of Energy laboratories, including the Thomas Jefferson National Accelerator Facility (JLab) and Fermi National Accelerator Laboratory (FNAL), are collaborating in this project. The cryomodules for this project each consist of eight 1.3-GHz cavities produced by two vendors, Research Instruments GmbH in Germany (RI*) and Ettore Zanon S.p.a. in Italy (EZ*), using niobium cell material from Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (OTIC/NX)). During the initial production run, cavity performance from one of the vendors (Vendor A) was far below expectation. All the cavities had low Q0, later attributed to minimal EP as well as high-flux-trapping NX material, early quench behaviour below 18 MV/m, with many having Q0 roll-off at 12-16 MV/m. Production was stopped multiple times over the following 6 months, with test batches of cavities being made to ascertain the root cause of the problem. The final root cause of the problem was found to be inappropriate grinding of the RF surface prior to welding which left normal conducting inclusions in the surface. In addition, most cavities showed internal and external weld spatter which required post weld grinding and a very rough surface from operating the electropolishing machine in an etching rather than polishing regime. All issues have been corrected on new cavities and rework is underway on the originally effected cavities.

Macha, Kurt M.↗