Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIBER STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Surface and interfacial properties of carbon fibers

The adhesion strength of AS4 fibers to thermoplastic polymers was determined. The specific polymers were polycarbonate, polyphenylene oxide, polyetherimide, polyphenylene oxide blends with polystyrene, and polycarbonate blends with a polycarbonate-polysiloxan copolymer. Data are also included for polysulfone. It was recognized at the outset that an absolute measure of the fiber matrix adhesion would be difficult. However, it is feasible to determine the fiber bond strengths to the thermoplastics relative to the bond strengths of the same fibers to epoxy polymers. It was anticipated, and in fact realized, that the adhesion of AS4 to the thermoplastic polymers was relatively low. Therefore, further objectives of the study were to identify means of increasing fiber/matrix adhesion and to try to determine why the adhesion of AS4 to thermoplastics is significantly less than to epoxy polymers.

Bascom, Willard D.↗

Compressive strength of fiber-reinforced composite materials

Results of an experimental and analytical investigation of the compressive strength of unidirectional boron-epoxy composite material are presented. Observation of fiber coordinates in a boron-epoxy composite indicates that the fibers contain initial curvature. Combined axial compression and torsion tests were conducted on boron-epoxy tubes and it was shown that the shear modulus is a function of axial compressive stress. An analytical model which includes initial curvature in the fibers and permits an estimate of the effect of curvature on compressive strength is proposed. Two modes of failure which may result from the application of axial compressive stress are analyzed - delamination and shear instability. Based on tests and analysis, failure of boron-epoxy under axial compressive load is due to shear instability.

Davis, J. G., Jr.↗

The Effect of Hole Quality on the Bearing Strength of Carbon Fiber Laminates

On programs involving flight hardware for launch vehicles that the author has been involved in over the years, the question always arises as to how to best machine and inspect holes drilled for fasteners. While common sense dictates that ‘well-drilled’ holes are desired over ‘poorly drilled’ holes for bolt bearing applications, the effect of hole quality on the bearing strength of carbon fiber laminates has not been extensively studied in the open literature. If this effect is not quantitatively known, the question of what hole quality needs to be required for the flight hardware cannot be answered. In addition, the function of the part with respect to the holes needs to be taken into account. There is no such thing as a defect-free hole since some chip-out of fibers within the hole will occur regardless of drill bit and backing plate pressure. For most holes machined in a carbon fiber laminate, some extent of delamination and fiber breakout on the entrance and exit of the hole is going to occur. Much time and money can be spent on trying to perfect the drilling technique and subsequent inspection of holes in carbon fiber laminates, including adding extra plies of cloth to the surfaces to help prevent fiber breakout; but is this effort really justified if little-to-no increase in bearing strength is realized by good-quality holes over those of lesser quality?

Nettles, A. T.↗

Effects of fiber, matrix, and interphase on carbon fiber composite compression strength

The major goal of this project was to obtain basic information on compression failure properties of carbon fiber composites. To do this, we investigated fiber effects, matrix effects, and fiber/matrix interface effects. Using each of nine fiber types, we prepared embedded single-fiber specimens, single-ply specimens, and full laminates. From the single-fiber specimens, in addition to the standard fragmentation test analysis, we were able to use the low crack density data to provide information about the distribution of fiber flaws. The single-ply specimens provided evidence of a correlation between the size of kink band zones and the quality of the interface. Results of the laminate compression experiments mostly agreed with the results from single-ply experiments, although the ultimate compression strengths of laminates were higher. Generally, these experiments showed a strong effect of interfacial properties. Matrix effects were examined using laminates subjected to precracking under mixed-mode loading conditions. A large effect of precracking conditions on the mode 1 toughness of the laminates was found. In order to control the properties of the fiber/matrix interface, we prepared composites of carbon fiber and polycarbonate and subjected these to annealing. The changes in interfacial properties directly correlated with changes in compression strength.

Nairn, John A.↗

Degradation in interfacial shear strength of carbon fiber/ vinyl ester composites due to long-term exposure to seawater using push-out tests

Here, in this study, single fiber (~7-μm diameter) push-out tests are conducted to evaluate hygrothermal effects on the interfacial shear strength (IFSS) of carbon fiber/vinyl ester (CF/VE) composites. Hygrothermal conditioning is achieved by saturating samples in simulated seawater at 40 °C for two years. An investigation has been conducted on the preparation, validity, and interpretation of the push-out test results. First, the authors present a polishing methodology that results in thin films of CF/VE composites in the thickness range of 15–120 μm and produces an average 41.2% drop in IFSS due to long-term hygrothermal exposure. Using scanning electron microscopy (SEM), we show that during the push-out tests, the failure initiates locally at the zone of minimum bond strength at the bottom (away from the indenter), then propagates along the length of the interface. The influence of radial tensile stresses originating due to bending is found to be negligible. Using the SEM imaging of the pushed-out fibers, we validate the failure of the interface to be the primary source of failure. The associated results are found to depend on the thickness of the interface. We then reevaluate the results using the Weibull distribution, knowing that the failure mechanism is analogous to the weakest link theory. The results show a 25.5% drop in the IFSS of the CFVE composite, measured at an infinitesimal scale due to long-term to hygrothermal conditioning at 40 °C. A significant drop in IFSS was observed after reheating above glass transition temperature (T g ) and cooling.

36 MATERIALS SCIENCE↗

Mechanical, Chemical and Microstructural Characterization of Monazite-Coated Silicon Carbide Fibers

Tensile strengths of as-received Hi-Nicalon and Sylramic fibers and those having monazite surface coatings, deposited by atmospheric pressure chemical vapor deposition, were measured at room temperature and the Weibull statistical parameters determined. The average tensile strengths of uncoated Hi-Nicalon and Sylramic fibers were 3.19 +/- 0.73 and 2.78 +/- 0.53 GPa with a Weibull modulus of 5.41 and 5.52, respectively. The monazite-coated Hi-Nicalon and Sylramic fibers showed strength loss of approx. 10 and 15 percent, respectively, compared with the as-received fibers. The elemental compositions of the fibers and the coatings were analyzed using scanning Auger microprobe and energy dispersive X-ray spectroscopy. The LaPO4 coating on Hi-Nicalon fibers was approximately stoichiometric and about 50 nm thick. The coating on the Sylramic fibers extended to a depth of about 100 to 150 nm. The coating may have been stoichiometric LaPO4 in the first 30 to 40 nm of the layer. However, the surface roughness of Sylramic fiber made this profile somewhat difficult to interpret. Microstructural analyses of the fibers and the coatings were done by scanning electron microscopy, transmission electron microscopy, and selected area electron diffraction. Hi-Nicalon fiber consists of fine beta-SiC nanocrystals ranging in size from 1 to 30 mn embedded in an amorphous matrix. Sylramic is a polycrystalline stoichiometric silicon carbide fiber consisting of submicron beta-SiC crystallites ranging from 100 to 300 nm. Small amount of TiB2 nanocrystallites (approx. 50 nm) are also present. The LaPO4 coating on Hi-Nicalon fibers consisted of a chain of peanut shape particles having monazite-(La) structure. The coating on Sylramic fibers consisted of two layers. The inner layer was a chain of peanut shape particles having monazite-(La) structure. The outer layer was comprised of much smaller particles with a microcrystalline structure.

Bansal, N. P.↗

Strength Scaling in Fiber Composites

A research program was initiated to study and isolate the factors responsible for scale effects in the tensile strength of graphite/epoxy composite laminates. Four layups were chosen with appropriate stacking sequences so as to highlight individual and interacting failure modes. Four scale sizes were selected for investigation including full scale size, 3/4, 2/4, and 1/4, with n = to 4, 3, 2, and 1, respectively. The full scale specimen sizes was 32 piles thick as compared to 24, 16, and 8 piles for the 3/4, 2/4, and 1/4 specimen sizes respectively. Results were obtained in the form of tensile strength, stress-strain curves and damage development. Problems associated with strength degradation with increasing specimen sizes are isolated and discussed. Inconsistencies associated with strain measurements were also identified. Enhanced x ray radiography was employed for damage evaluation, following step loading. It was shown that fiber dominated layups were less sensitive to scaling effects compared to the matrix dominated layups.

Kellas, Sotiris↗

Strength scaling in fiber composites

A research program was initiated to study and isolate the factors responsible for scale effects in the tensile strength of graphite/epoxy composite laminates. Four layups were chosen with appropriate stacking sequences so as to highlight individual and interacting failure modes. Four scale sizes were selected for investigation including full scale size, 3/4, 2/4, and 1/4, with n = to 4, 3, 2, and 1, respectively. The full scale specimen sizes was 32 piles thick as compared to 24, 16, and 8 piles for the 3/4, 2/4, and 1/4 specimen sizes respectively. Results were obtained in the form of tensile strength, stress-strain curves and damage development. Problems associated with strength degradation with increasing specimen sizes are isolated and discussed. Inconsistencies associated with strain measurements were also identified. Enchanced X-ray radiography was employed for damage evaluation, following step loading. It was shown that fiber dominated layups were less sensitive to scaling effects compared to the matrix dominated layups.

Kellas, Sotiris↗

On the use of limestone calcined clay cement (LC3) in high-strength strain-hardening cement-based composites (HS-SHCC)

Highlights: • Use of LC{sup 3} slightly reduces flowability and shortens the setting time of fresh matrices. • Highly polymerized C-A-S-H gel and abundant ettringite benefit flexural strength of LC{sup 3}-matrices. • Use of LC{sup 3} enhances the bond strength between fiber and high-strength matrix. • LC{sup 3}-based HS-SHCC yields similar flexural performance as the composite with Portland cement. High-strength strain-hardening cement-based composites (HS-SHCC) demonstrate excellent mechanical and durability properties. However, high cement content typical to HS-SHCC results not only in high carbon footprint, but also in excessive hydration heat and severe autogenous shrinkage. In this investigation, Limestone Calcined Clay Cement (LC{sup 3}) was used to produce sustainable HS-SHCC. The LC{sup 3} substitution resulted in higher energy consumption during mixing and in shorter setting times of the fresh, plain matrices. Although the LC{sup 3} substitution slightly reduced the compressive strength, the formation of highly polymerized C-A-S-H gel and abundant ettringite benefited the flexural strength of the plain matrices. Additionally, single-fiber pullout experiments showed that the use of LC{sup 3} led to increased fiber-matrix bond strength and pullout energy. Finally, the replacement of Portland cement by LC{sup 3} resulted in HS-SHCC with similar mechanical performance to the reference composite, indicating a high potential for using LC{sup 3} in high-performance cement-based composites.

36 MATERIALS SCIENCE↗

Correlation of fiber composite tensile strength with the ultrasonic stress wave factor

An ultrasonic-acoustic technique was used to indicate the strength variations of tensile specimens of a graphite-epoxy composite. A 'stress wave factor' was determined and its value was found to depend on variations of the fiber-resin bonding as well as fiber orientation. The fiber orientations studied were 0 deg (longitudinal), 10 deg (off-axis), 90 deg (transverse), (0 deg/+ or - 45 deg/0) symmetrical, and (+ or - 45 deg) symmetrical. The stress wave factor can indicate variations of the tensile and shear strengths of composite materials. The stress wave factor was also found to be sensitive to strength variations associated with microporosity and differences in fiber-resin ratio.

Vary, A.↗

Correlation of Fiber Composite Tensile Strength with the Ultrasonic Stress Wave Factor

An ultrasonic-acoustic technique was used to indicate the strength variations of tensile specimens of a graphite-epoxy composite. A stress wave factor was determined and its value was found to depend on variations of the fiber-resin bonding as well as fiber orientation. The fiber orientations studied were 0 deg (longitudinal), 10 deg (off-axis), 90 deg (transverse), 0 deg + or - 45 deg/0 deg symmetrical, and + or - 45 deg] symmetrical. The stress wave factor can indicate variations of the tensile and shear strengths of composite materials. The stress wave factor was also found to be sensitive to strength variations associated with microporosity and differences in fiber-resin ratio.

Vary, A.↗

Factors affecting miniature Izod impact strength of tungsten-fiber-metal-matrix

The miniature Izod and Charpy impact strengths of copper, copper-nickel, and nickel-base superalloy uniaxially reinforced with continuous tungsten fibers were studied. In most cases, impact strength was increased by increasing fiber or matrix toughness, decreasing fibermatrix reaction, increasing test temperature, hot working, or heat treating. Notch sensitivity was reduced by increasing fiber content or matrix toughness. An equation relating impact strength to fiber and matrix properties and fiber content was developed. Program results imply that tungsten alloy-fiber/superalloy matrix composites can be made with adequate impact resistance for turbine blade or vane applications.

Winsa, E. A.↗

Hydrogen bonds, interfacial stiffness moduli, and the interlaminar shear strength of carbon fiber-epoxy matrix composites

The chemical treatment of carbon fibers used in carbon fiber-epoxy matrix composites greatly affects the fraction of hydrogen bonds (H-bonds) formed at the fiber-matrix interface. The H-bonds are major contributors to the fiber-matrix interfacial shear strength and play a direct role in the interlaminar shear strength (ILSS) of the composite. The H-bond contributions τ to the ILSS and magnitudes K{sub N} of the fiber-matrix interfacial stiffness moduli of seven carbon fiber-epoxy matrix composites, subjected to different fiber surface treatments, are calculated from the Morse potential for the interactions of hydroxyl and carboxyl acid groups formed on the carbon fiber surfaces with epoxy receptors. The τ calculations range from 7.7 MPa to 18.4 MPa in magnitude, depending on fiber treatment. The K{sub N} calculations fall in the range (2.01 – 4.67) ×10{sup 17} N m{sup −3}. The average ratio K{sub N}/|τ| is calculated to be (2.59 ± 0.043) × 10{sup 10} m{sup −1} for the seven composites, suggesting a nearly linear connection between ILSS and H-bonding at the fiber-matrix interfaces. The linear connection indicates that τ may be assessable nondestructively from measurements of K{sub N} via a technique such as angle beam ultrasonic spectroscopy.

36 MATERIALS SCIENCE↗

Pyrolysis Rate and Yield Strength Reduction Incarbon Fiber and Glass Fiber Composites Underreentry Heating Conditions

The behavior of composite materials, specifically carbon fiber reinforced plastic (CFRP) and glass fiber reinforced plastic (GFRP), under reentry conditions poses a problem for space debris reentry risk modeling. Since these materials pyrolyze rather than melt and their different components demise at different rates, modeling their destruction to determine ground impact risk is complex. Modern spacecraft are using these materials in ever-greater quantities owing to their superior strength-to-weight characteristics, and this has required that the orbital debris community improve its understanding of how these materials demise on reentry. The NASA Orbital Debris Program Office undertook an extensive test campaign to better understand the rate at which several types of GFRP and CFRP materials pyrolyze under reentry heating conditions and how that pyrolysis affects the ultimate strength of the material. GFRP with a polyester resin (G10/FR-4) and CFRP with epoxy, cyanate ester, vinyl ester, and phenolic resins were tested. The test campaign was carried out at the Inductively Coupled Plasma (ICP) Torch Facility at the University of Texas at Austin. Because the ICP facility operates in a shirt-sleeve environment, test samples can be changed within seconds or minutes, allowing many samples to be tested in a short period. Two heat flux rates, 20 W/m2 and 30W/m2, and two oxygen concentration conditions, 0% and 2% of atmospheric, were applied to all five types of material. To measure both the char rate and the effect of pyrolysis on the ultimate material strength, two types of test were carried out for each material: a char rate test on a ~10 mm thick sample of material and an in-situ bending stress test of a ~2 mm thick sample of material. Measurements of the char rate showed very similar average pyrolysis front velocity in epoxy resin CFRP as in G10 at 3.6 mm/min and 3.4 mm/min, respectively. However, the total mass loss rate in theG10 was nearly double that of the CFRP at 3.8 g/min and 2.2 g/min, respectively. This result represented a slow ablation rate of carbon fibers in the CFRP at the temperatures encountered in low Earth orbit reentry and a comparatively rapid removal of the glass fibers in G10 due to melting and spallation. Pyrolysis front velocity was more significantly affected by the type of plastic than the type of fiber, with the cyanate ester CFRP samples displaying an average pyrolysis front velocity of only 1.9 mm/min. Similarly, the effect of thermal exposure on the ultimate strength of the material depended heavily on the type of plastic and very little on the type of fiber in the material. Epoxy, vinyl ester, and polyester resins all behaved very similarly, with complete structural failure at between 400 J/g and 600 J/g of specific absorbed heat. Phenolic and cyanate ester resins, on the other hand, displayed a change in structural properties that was only barely measurable with the current apparatus even after the maximum exposure time tested. These data are being incorporated into a numerical model of the ablation and demise of composite materials that will be used to more accurately calculate the ground casualty risk of future spacecraft.

Benton R. Greene↗

Out-of-Pile Testing of Radiation Hard Optical Fibers

The work detailed in this report was supported under the In-Pile Instrumentation program for FY19. The work was conducted by researchers at Boise State University (BSU) and Idaho National Laboratory (INL). This report describes the out-of-pile testing that has been conducted to help guide sensor design and data interpretation by providing a robust understanding of out-of-pile fiber optic performance under different environmental factors. Highlighted in this report are two test configurations, transmission testing of optical fibers over a range of temperatures, and tensile testing of optical fibers identified through prior research as having potential for in-core use. The transmission temperature testing is conducted with high spectral resolution to study the influence of elevated temperatures on transmission. This testing has been conducted from room temperature up to 800ºC. The transmission testing was conducted by BSU at the Fiber Laser and Integrated photonics Research (FLaIR) laboratory. This testing will allow separation of radiation and temperature effects during in-core testing and allow for a more thorough understanding of radiation effects on fiber sensors. The tensile testing of optical fibers was conducted to provide a baseline for the strength of fiber optics. The fragile nature of glass fibers is a limitation in the deployment of fiber optics. Furthermore, intrinsic fiber optic sensors such as Fiber Bragg Gratings (FBG) add defects or damaged areas to the fiber which reduce its strength and can lead to broken sensors if not handled with care. The thermo-mechanical test facility enables the ability to quantitatively measure the strength of fibers with and without FBG’s over a temperature range. This information will be used to determine which types of FBG’s, and other sensors, are likely to survive the installation process. These tests will also be used to characterize the potential measurement range of fiber based strain sensors. The tensile testing was completed at INL in the HTTL Fiber Optics and Ultrasonic Technologies (FOUT) laboratory. Pure silica core (PSC) optical fibers have been shown to perform well in harsh environments. Transmission testing and tensile testing showed little change in fiber dynamic strength and transmission with elevated temperatures. There was no significant weakening of the fiber for temperatures up to 200ºC. Transmission at 1550 nm (a common wavelength used for optical sensors) showed minimal changes up to 800ºC with some improvement after 12 hours of annealing at 800ºC. This indicates that PSC optical fiber is a good candidate for in-pile testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Engineered Interface Chemistry to Improve the Strength of Carbon Fiber Composites Cured by Electron Beam

A reactive sizing was designed to achieve high levels of interfacial adhesion and mechanical properties with a carbon fiber-acrylate system cured by electron beam (EB). The sizing was made of a partially cured epoxy sizing with a high density of pendant functional groups (acrylate functionality) able to generate a covalent bonding with the matrix. The interlaminar shear strength was clearly improved from 61 MPa to 81 MPa (+ 33 %) without any post-processing, reaching a similar value to the one obtained with the same system cured by a thermal treatment. Observation of the fracture profiles clearly highlighted a change in the fracture mechanism from a purely adhesive failure to a cohesive failure. Such improvements of the mechanical properties of carbon fiber composites cured by EB, without any post-cure, have not been reported previously to the best of our knowledge. This constitutes a breakthrough for the industrial development of composites EB curing.

acrylate↗